Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sheaths”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Low drift type N thermocouples in out-of-pile advanced gas reactor mock-up test: metallurgical analysis

Thermocouples are the most commonly used sensors for temperature measurement in nuclear reactors. They are crucial for the control of current nuclear reactors and for the development of GEN IV reactors. In nuclear applications thermocouples are strongly affected by intense neutron fluxes. As a result of the interaction with neutrons, the thermoelements of the thermocouples undergo transmutation, which produces a time dependent change in composition and, as a consequence, a time dependent drift of the thermocouple signal. Thermocouple drift can be very significant for in-pile temperature measurements and may render the temperature sensors unreliable after exposure to nuclear radiation for relatively short times compared to the life required for temperature sensors in nuclear applications. Previous experiences with type K thermocouples in nuclear reactors have shown that they are affected by neutron irradiation only to a limited extent. Similarly type N thermocouples are expected to be only slightly affected by neutron fluxes. Currently the use of Nickel based thermocouples is limited to temperatures lower than 1000 deg. C due to drift related to phenomena other than nuclear irradiation. As part of a collaboration between Idaho National Laboratory (INL) and the University of Cambridge a variety of Type N thermocouples have been exposed at INL in an Advanced Gas Reactor mock-up test at 1150 deg. C for 2000 h, 1200 deg. C for 2000 h, 125 deg. C for 200 h and 1300 deg. C for 200 h, and later analysed metallurgically at the University of Cambridge. The use of electron microscopy allows to identify the metallurgical changes occurring in the thermocouples during high temperature exposure and correlate the time dependent thermocouple drift with the microscopic changes experienced by the thermoelements of different thermocouple designs. In this paper conventional Inconel 600 sheathed type N thermocouples and a type N using a customized sheath developed at the University of Cambridge have been investigated. The rationale for the superior performance of the type N using a customized sheath developed at the University of Cambridge is explained in comparison with the behavior of conventional type N Inconel 600 sheathed thermocouples. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Summary of thermocouple performance during advanced gas reactor fuel irradiation experiments in the advanced test reactor and out-of-pile thermocouple testing in support of such experiments

High temperature gas reactor experiments create unique challenges for thermocouple-based temperature measurements. As a result of the interaction with neutrons, the thermoelements of the thermocouples undergo transmutation, which produces a time-dependent change in composition and, as a consequence, a time-dependent drift of the thermocouple signal. This drift is particularly severe for high temperature platinum-rhodium thermocouples (Types S, R, and B) and tungsten-rhenium thermocouples (Type C). For lower temperature applications, previous experiences with Type K thermocouples in nuclear reactors have shown that they are affected by neutron irradiation only to a limited extent. Similarly, Type N thermocouples are expected to be only slightly affected by neutron fluence. Currently, the use of these nickel-based thermocouples is limited when the temperature exceeds 1000 deg. C due to drift related to phenomena other than nuclear irradiation. High rates of open-circuit failure are also typical. Over the past 10 years, three long-term Advanced Gas Reactor experiments have been conducted with measured temperatures ranging from 700 deg. C - 1200 deg. C. A variety of standard Type N and specialty thermocouple designs have been used in these experiments with mixed results. A brief summary of thermocouple performance in these experiments is provided. Most recently, out-of-pile testing has been conducted on a variety of Type N thermocouple designs at the following (nominal) temperatures and durations: 1150 deg. C and 1200 deg. C for 2,000 hours at each temperature, followed by 200 hours at 1250 deg. C and 200 hours at 1300 deg. C. The standard Type N design utilizes high purity, crushed MgO insulation and an Inconel 600 sheath. Several variations on the standard Type N design were tested, including a Haynes 214 alloy sheath, spinel (MgAl{sub 2}O{sub 4}) insulation instead of MgO, a customized sheath developed at the University of Cambridge, and finally a loose assembly thermocouple with hard-fired alumina insulation and a molybdenum sheath. The most current version of the High Temperature Irradiation Resistant Thermocouple, based on molybdenum/niobium alloys and developed at Idaho National Laboratory, was also tested. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Investigation of Materials for Radio Frequency Antenna Plasma Facing Components

Here, the interaction of radio frequency (RF) sheaths with fusion reactor relevant materials (e.g., tungsten and titanium diboride) is being studied on the RF Plasma Interaction Experiment (RF PIE). The RF PIE consists of an electron cyclotron resonance (ECR) plasma source (2.45 GHz, 5 kW) with a biased and heated RF electrode that is used to simulate antenna surfaces in contact with the edge plasma. Helium plasmas (density of ~1e18/m 3 , electron temperature of 4–5 eV) are being used to explore sheath formation on material surfaces with biases up to 500 V. The erosion of a tungsten surface is being studied spectroscopically using a mirror-linked 1 m Czerny-Turner UV imaging spectrometer with a spectral resolution of 0.012 nm for measuring plasma emission in and near the sheath. Tungsten line emission intensity is higher for RF versus dc biasing for similar plasma conditions and average ion energy. RF biasing causes a broadening of the ion energy distribution function (IEDF) due to the RF sheath, as determined from the hPIC2 code, and results in enhanced sputtering. Calculations of the expected sputtering yield for dc and RF biasing are consistent with experimental observations of changes in the 400.9 nm tungsten line emission intensity as a function of ion energy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Radio-frequency discharge in a molecular gas flow at a frequency of 1.76 MHz

Results are presented from experiments on the initiation of a homogeneous stable capacitive RF discharge at a frequency of 1.76 MHz in a high-speed molecular gas flow between metal electrodes at a pressure of 5 Torr or dielectric-coated electrodes at a pressure of up to 50 Torr. A mechanism of the current closure in the electrode sheaths related to the primary photoelectric current generated alternately from different electrodes is proposed. The average electron energy increases via second-kind (superelastic) collisions, and fast electrons with energies corresponding to the amplitude value of the RF voltage appear in the electron energy spectrum. As a result, primary emission arises due to the excitation of emitting states from metastable molecular levels. The primary photoelectric current initiates electron avalanches in the electrode sheaths due to secondary photoelectron emission. According to calculations, the current−voltage characteristic of the sheath in this type of discharge is ascending and the field strengths in the electrode sheath and positive column are lower than those in a self-sustained dc discharge. The calculated results are compared with the experimental data.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Genes for the Major Structural Components of Thermotogales Species' Togas Revealed by Proteomic and Evolutionary Analyses of OmpA and OmpB Homologs

The unifying structural characteristic of members of the bacterial order Thermotogales is an unusual cell envelope that includes a loose-fitting sheath around each cell, often called a toga. Only two toga-associated structural proteins have been identified in Thermotoga maritima: the anchor protein OmpA1 (previously termed Ompα) and the porin OmpB (previously termed Ompβ). The gene encoding OmpA (ompA1) was assigned in the genome sequence to TM0477, but because no peptide sequence was available for OmpB, its gene (ompB) was not annotated. Here we identify the ompB gene as TM0476, determined by LC/MS/MS analysis of the native OmpB protein purified from T. maritima cells. The purified OmpB had β-sheet secondary structure as determined by circular dichroism. Analysis of the sequence of ompB product shows it has porin characteristics including a carboxy terminus anchoring motif and a porin-specific amino acid composition. Orthologs of ompB were found in the genomes of some, but not all, Thermotogales. Those without orthologs have putative analogs. Phylogenetic analyses of OmpA1 revealed that each species of the Thermotogales has one to three OmpA homologs. T. maritima has two OmpA homologs, encoded by ompA1(TM0477) and ompA2 (TM1729), both of which were found in the toga protein-enriched cell extracts. These annotations of the genes encoding toga structural proteins will guide future examinations of the structure and function of this unusual lineage-defining cell sheath.

59 BASIC BIOLOGICAL SCIENCES↗

Selective evaporation of focusing fluid in two-fluid hydrodynamic print head.

The work performed in this project has demonstrated the feasibility to use hydrodynamic focusing of two fluid steams to create a novel micro printing technology for electronics and other high performance applications. Initial efforts focused solely on selective evaporation of the sheath fluid from print stream provided insight in developing a unique print head geometry allowing excess sheath fluid to be separated from the print flow stream for recycling/reuse. Fluid flow models suggest that more than 81 percent of the sheath fluid can be removed without affecting the print stream. Further development and optimization is required to demonstrate this capability in operation. Print results using two-fluid hydrodynamic focusing yielded a 30 micrometers wide by 0.5 micrometers tall line that suggests that the cross-section of the printed feature from the print head was approximately 2 micrometers in diameter. Printing results also demonstrated that complete removal of the sheath fluid is not necessary for all material systems. The two-fluid printing technology could enable printing of insulated conductors and clad optical interconnects. Further development of this concept should be pursued.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Thermocouple Testing in Support of the AGR-5/6/7 Experiment

This report documents thermocouple testing performed in IRC Lab C-15 over a period of seven years. This testing supported selection and characterization of the thermocouple set used in the AGR-5/6/7 experiment. The following summary was taken directly from the report. Temperature measurement is a challenging aspect of very high temperature irradiation experiments because commonly used high-temperature commercial thermocouples such as platinum-rhodium (Types S, R, and B) and tungsten-rhenium (Type C), suffer dramatic drift because of neutron-induced transmutation. As a result, these types of thermocouples, which are used routinely for industrial temperature measurements outside of reactors, are used only in very special circumstances for reactor experiments. Conversely, because of their low neutron cross-sections, Type N thermocouples are affected to only a limited extent by neutron irradiation. However, the use of these nickel-based thermocouples is limited when the temperature exceeds 1050°C due to drift arising from minor alloying elements migrating from the thermocouple's metal sheath to the thermoelements. This change in the composition of the thermo-elements results in significant decalibration of the signal. The issues described above were recognized during the early planning stages of the final AGR experiment (designated AGR-5/6/7), and a thermocouple furnace testing program was performed over a seven-year period (2014-2019, 2021) to first select and then characterize the best thermocouple set for the high temperature regions of the AGR-5/6/7 irradiation experiment. The calculated temperature range of the AGR-5/6/7 experiment was 600–1500°C. For temperatures below 1000°C standard Type N thermocouples were deemed adequate. The furnace testing campaign identified two thermocouple types suitable for measuring temperatures above 1000°C, a Mo/Nb thermocouple developed at INL called HTIR-TC, and a Type N thermocouple developed by Cambridge University (called herein Cambridge Type N), which featured a custom high nickel alloy sheath. One of the original goals of the furnace testing program was to identify a thermocouple capable of low drift operation near the peak temperature expected in AGR-5/6/7, i.e., about 1400°C. The HTIR-TC design appeared promising in this regard, however a manufacturing difficulty proved to be a barrier and instead the furnace testing focused on drift performance at 1250°C. The manufacturing difficulty was that the Nb sheaths of the HTIR-TCs experienced extreme embrittlement when heat treated at 1600°C or greater. Heat treatment is needed to stabilize the emf output of this TC type, and the higher the heat treatment temperature the higher the peak temperature of stable operation. Because of the sheath embrittlement the heat treatment temperature had to be lowered to 1450°C resulting in a stable operating temperature of about 1250°C. One of the successes of the furnace testing program was identification of a shortcoming in the heat treatment procedure that had been traditionally used in the production of HTIR-TCs. The shortcoming was that the entire heated length of the HTIR-TC sensor was not being heat treated, but rather only the part of the sensor expected to experience temperatures above 1000°C. The problem manifested itself when the thermocouples were removed from the heat treat furnace and placed in another furnace with a different geometry, their indicated temperatures would be widely scattered, but mostly in the negative direction. The solution was to heat treat the entire heated length of the sensor. Since the deepest immersion depth in the AGR-5/6/7 experiment was about 40 inches, a heat treatment length of 48 inches was used. After this change was implemented, thermocouples which were moved into a new environment with a different temperature profile (i.e., a different furnace), produced accurate temperature measurements. Although assembly of the AGR-5/6/7 experiment was completed in September of 2017 (and irradiation begun in 2018), furnace testing of thermocouples continued in 2018 and 2019. The main purpose of this testing was to establish very long-term drift characteristics of the HTIR and Cambridge Type N thermocouples installed in the experiment. Representative thermocouples from the same lots as those installed in the AGR-5/6/7 experiment were used. Additionally, thermocouples of different designs, (particularly variations on the HTIR-TC design) were "piggy-backed" on this testing program to provide insights for instrumenting future very high temperature irradiation experiments. This two-year testing program demonstrated that HTIR-TCs and Cambridge Type N TCs could operate at 1250°C for up to 10,000 hrs (and in some cases longer) while experiencing negative drifts on the order of 2-4°C/1000 hrs. This performance was considered acceptable given the extreme operating environment the sensors faced.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DOE Final Report on Virginia Tech’s contribution to “Tokamak Disruption Simulation”

This work was performed by Virginia Tech in collaboration with multiple institutions led by Los Alamos National Laboratory as a part of the Tokamak Disruption Simulation SciDAC (Scientific Discovery through Advanced Computing) project supported jointly by the Department of Energy Office of Science and Ad- vanced Scientific Computing Research. This report summarizes Virginia Tech’s contributions to the Sci- DAC project. Virginia Tech researchers (presently University of Washington researchers) focused on the fundamental role of plasma-material interaction on transport, which could then have macroscopic effects on simulations of tokamak disruptions. The plasma sheath, which regulates plasma particle and energy fluxes to the wall, is an essential component in the study of plasma-material interaction (PMI). Understanding sheath theory by accounting for finite sheath thickness and transport in the vicinity of the sheath entrance can sig- nificantly modify typical assumptions that are made in the Bohm speed analysis, where the Bohm speed provides the lower bound of the plasma exit flow speed. Our work provides a modified Bohm speed formu- lation that accounts for the critical role of transport and for applications that are away from the asymptotic limits that are typically assumed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

AVERAGE SPATIAL DISTRIBUTION OF COSMIC RAYS BEHIND THE INTERPLANETARY SHOCK—GLOBAL MUON DETECTOR NETWORK OBSERVATIONS

We analyze the galactic cosmic ray (GCR) density and its spatial gradient in Forbush Decreases (FDs) observed with the Global Muon Detector Network (GMDN) and neutron monitors (NMs). By superposing the GCR density and density gradient observed in FDs following 45 interplanetary shocks (IP-shocks), each associated with an identified eruption on the Sun, we infer the average spatial distribution of GCRs behind IP-shocks. We find two distinct modulations of GCR density in FDs, one in the magnetic sheath and the other in the coronal mass ejection (CME) behind the sheath. The density modulation in the sheath is dominant in the western flank of the shock, while the modulation in the CME ejecta stands out in the eastern flank. This east–west asymmetry is more prominent in GMDN data responding to ∼60 GV GCRs than in NM data responding to ∼10 GV GCRs, because of the softer rigidity spectrum of the modulation in the CME ejecta than in the sheath. The geocentric solar ecliptic- y component of the density gradient, G {sub y}, shows a negative (positive) enhancement in FDs caused by the eastern (western) eruptions, while G {sub z} shows a negative (positive) enhancement in FDs caused by the northern (southern) eruptions. This implies that the GCR density minimum is located behind the central flank of IP-shocks and propagating radially outward from the location of the solar eruption. We also confirmed that the average G {sub z} changes its sign above and below the heliospheric current sheet, in accord with the prediction of the drift model for the large-scale GCR transport in the heliosphere.

79 ASTRONOMY AND ASTROPHYSICS↗

An effective and practical fire-protection system

A high-performance sandwich-type fire protection system comprising a steel outer sheath and insulation combined in various configurations is described. An inherent advantage of the sheath system over coatings is that it eliminates problems of weatherability, materials strength, adhesion, and chemical attack. An experimental comparison between the protection performance of state-of-the-art coatings and the sheath system is presented, with emphasis on the protection of certain types of steel tanks for fuel storage and transport. Sheath systems are thought to be more expensive than coatings in initial implementation, although they are less expensive per year for sufficiently long applications.

Mansfield, J. A.↗

Interplanetary magnetic holes: Theory

Magnetic holes in the interplanetary medium are explained as stationary, non-propagating, equilibrium structures in which there are field-aligned enhancements of the plasma density and/or temperature. Magnetic anti-holes are considered to be associated with depressions in the plasma pressure. In this model, the observed changes in the magnetic field intensity and direction are due to diamagnetic currents that are carried by ions which drift in a sheath as the result of gradients in the magnetic field and in the plasma pressure within the sheath. The thickness of the sheaths considered is approximately a few ion Larmor radii. An electric field is normal to the magnetic field in the sheath. Solutions of Vlasov's equation and Maxwell's equations are presented which account for several types of magnetic holes, including null-sheets, that were observed.

Burlaga, L. F.↗

Interplanetary magnetic holes - Theory

Magnetic holes in the interplanetary medium are explained as stationary nonpropagating equilibrium structures in which there are field-aligned enhancements of the plasma density and/or temperature. Magnetic antiholes are considered to be associated with depressions in the plasma pressure. In this model the observed changes in the magnetic field intensity and direction are due to diamagnetic currents that are carried by ions which drift in a sheath as the result of gradients in the magnetic field and in the plasma pressure within the sheath. The thickness of the sheaths that we consider is approximately a few ion Larmor radii. An electric field is normal to the magnetic field in the sheath. Solutions of Vlasov's equation and Maxwell's equations are presented which account for several types of magnetic holes, including 'null sheets,' that have been observed.

Burlaga, L. F.↗

Three dimensional space charge model for large high voltage satellites

High power solar arrays for satellite power systems with dimensions of kilometers, and with tens of kilovolts distributed over their surface face many plasma interaction problems that must be properly anticipated. In most cases, the effects cannot be adequately modeled without detailed knowledge of the plasma sheath structure and space charge effects. Two computer programs were developed to provide fully self consistent plasma sheath models in three dimensions as a result of efforts to model the experimental plasma sheath studies at NASA/JSC. Preliminary results indicate that for the conditions considered, the Child-Langmuir diode theory can provide a useful estimate of the plasma sheath thickness. The limitations of this conclusion are discussed. Some of the models presented exhibit the strong ion focusing observed in the JSC experiments.

Cooks, D.↗

Ground-based plasma contractor characterization

Presented are recent NASA Lewis Research Center (LeRC) plasma contractor experimental results, as well as a description of the plasma contractor test facility. The operation of a 24 cm diameter plasma source with hollow cathode was investigated in the lighted-mode regime of electron current collection from 0.1 to 7.0 A. These results are compared to those obtained with a 12 cm plasma source. Full two-dimensional plasma potential profiles were constructed from emissive probe traces of the contractor plume. The experimentally measured dimensions of the plume sheaths were then compared to those theoretically predicted using a model of a spherical double sheath. Results are consistent for currents up to approximately 1.0 A. For currents above 1.0 A, substantial deviations from theory occur. These deviations are due to sheath asphericity, and possibly volume ionization in the double-sheath region.

Patterson, Michael J.↗

Ground-based plasma contactor characterization

This paper presents recent NASA Lewis Research Center plasma contactor experimental results, as well as a description of the plasma contactor test facility. The operation of a 24-cm-diameter plasma source with hollow cathode was investigated in the 'ignited-mode' regime of electron current collection from 0.1 to 7.0 A. These results are compared to those obtained with a 12-cm plasma source. Full two-dimensional plasma potential profiles were constructed from emissive probe traces of the contactor plume. The experimentally measured dimensions of the plume sheaths were then compared to those theoretically predicted, using a model of a spherical double sheath. Results are consistent for currents up to approximately 1.0 A. For currents above 1.0 A, substantial deviations from theory occur. These deviations are due to sheath asphericity, and, possibly, volume ionization in the double-sheath region.

Patterson, Michael J.↗

U. radio emission from quiescent filaments

Full-disk Very Large Array (VLA) synthesis maps of the quiet Sun indicate that filaments can be seen in emission at 91.6 cm wavelength; they are detected in absorption at shorter microwave wavelengths. The 91.6 cm emission has a brightness temperature of T sub B = 3 x 10(exp 5) K. It is hotter, wider and longer than the underlying filament detected at H alpha wavelengths, but the similarity between the shape, position, elongation and orientation of the radio and optical features suggests their close association. The 91.6 cm emission is attributed to the thermal-bremsstrahlung of a hot transition sheath that envelopes the H alpha filament and acts as an interface between the cool, dense H alpha filament and the hotter, rarefied corona. The transition sheath is seen in emission because of the lower optical depth of the corona at 90 cm wavelength, and the width of this sheet is 10(exp 9) cm. A power law gradient in pressure provides a better match to the observations than a constant pressure model; definitive tests of theoretical models await simultaneous multi-wavelength studies of filaments at different observing angles. When the thermal bremsstrahlung is optically thin, the magnetic field strength in the transition sheath can be inferred from the observed circular polarization. Variable physical parameters of the sheath, such as width, electron density, and electron temperature, can explain controversial reports of the detection of, or the failure to detect, the meter-wavelength counterpart of H alpha filaments.

Lang, Kenneth R.↗

The formation and structure of plasma wakes behind large high-voltage space platforms in ionosphere

Theory and particle simulation results are presented for ionospheric plasma flow over space platforms in the large-dimension and high-voltage range. Both the transient formation of the space-charge wake and its steady state structure are studied. The wake-side ion impact and current collection are obtained. It is found that the wake behind a high-voltage plate is characterized by two ion-rich sheaths embedded in a quasi-neutral background wake. The embedded sheath is formed by the ions passing through the sheath around the plate edge and serves as their trajectory path. Depending on the surface potential, the plate dimension, and the angle of attack, the embedded sheath may either extend downstream or curve back to the plate causing a high, localized ion flux density at the location it strikes.

Wang, J.↗

Identification of low-frequency fluctuations in the terrestrial magnetosheath

On the basis of magnetohydrodynamic (MHD) theory we develop a scheme for distinguishing among the four low-frequency modes which may propagate in a high-beta anisotropic plasma such as the magnetosheath: the fast and slow magnetosonic, the Alfven, and mirror modes. We use four parameters: the ratio of transverse to compressional powers in the magnetic field, the ratio of the wave powers in the thermal pressure and in the magnetic field, the ratio of the perturbations in the thermal and magnetic pressures, and the ratio of the wave powers in the velocity and in the magnetic field. In the test case of an Active Magnetospheric Particle Tracer Explorers/Ion Release Module (AMPTE/IRM) magnetosheath pass near the Sun-Earth line downstream of a quasi-perpendicular shock, the four modes can be clearly distinguished both spatially and spectrally. Near the bow shock, the waves are Alfvenic in a large frequency range, 1 to 100 mHz. In the middle and inner magnetosheath, the waves below 10 mHz are Alfvenic. The fast mode waves occur in the higher-frequency end of the enhanced spectrum, 80 mHz for the middle magnetosheath and 55 mHz for the inner sheath. The wave enhancement in the intermediate frequencies is slow modes in the inner sheath and mirror modes in the middle sheath. This confirms the earlier report of the existence of the slow mode waves near the magnetopause. These slow waves provide evidence that the magnetopause is an active source of the waves in the sheath. We also show that the measured frequency of a wave is close to an invariant if the magnetosheath flow is in a steady state. Therefore changes in the frequencies of enhanced waves indicate emergence, or damping, or mode conversion of the waves.

Song, P.↗