Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “renewable energy deployment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Characterization of a selective, zero power sensor for distributed sensing of hydrogen in energy applications

The use of hydrogen as a clean and renewable energy source is increasing rapidly for both vehicle and stationary applications. There are safety concerns for the locations in which hydrogen is made, used, and transported (i.e., pipelines and tanker trucks). Sensors are needed to comply with safety regulations and to enable a smooth and safe rollout of hydrogen as an alternative energy. However, hydrogen sensors do not yet exist that have the combined features of small size and low power for easy deployment coupled with high-volume manufacturability and low cost. This is necessary to accommodate the emerging fixed and mobile markets while retaining critical metrological metrics, including measurement range, detection limits, selectivity, fast response, stability, and long lifetime. An amperometric gas sensor for hydrogen (AGS) has been developed using an innovative manufacturing method. The sensor was designed using scalable fabrication strategies based on “Printed Electronics” (PE) methodology which are compatible with large-scale production. Prototype sensors were batch fabricated with multiple individual elements on a substrate compatible in size with a standard 8-inch wafer to enable high-volume, low-cost manufacturing, thereby leveraging PE and semiconductor fabrication infrastructure. This novel AGS was instrumented with control circuitry and evaluated for hydrogen detection in the range of 0–5000 ppmv H2 in air. Specific performance evaluations included assessment of the sensor measurement range, repeatability, and selectivity.

08 HYDROGEN↗

Regime-specific Cloud Vertical Overlap Characteristics from Radar and Lidar Observations at the ARM sites

Climate and numerical weather prediction models require assumptions to represent the vertical distribution of subgrid-scale clouds, which have radiative transfer implications. In this study, nearly 25 years of ground-based radar and lidar observations of vertical cloud profiles at the Atmospheric Radiation Measurement Program (ARM) Southern Great Plains (SGP) site are utilized to derive cloud vertical overlap characteristics from the Cloud Type (CLDTYPE) data product. Here, the cloud vertical overlap characteristics are further separated by cloud regime by considering seven cloud types (i.e., low cloud, congestus, deep convection, altocumulus, altostratus, cirrostratus, and cirrus) as well as periods of shallow cumulus. The decorrelation length scale (i.e., exponential transition from maximum to random overlap with layer separation) is found to vary by cloud regime, ranging between 0.04 km for cirrostratus paired with cirrus to 4.58 km for low cloud paired with cirrus at SGP. Cloud vertical overlap characteristics are also considered for other ARM sites including the Tropical Western Pacific (TWP), North Slope of Alaska (NSA), and Eastern North Atlantic (ENA) sites amongst other shorter term ARM deployments globally. The decorrelation length scale ranged globally from 1.03 km in the Arctic Ocean to 3.06 km in Manacapuru, Brazil. Globally, the decorrelation length scale by cloud regime exhibited similarities (e.g., for cirrus paired with cirrus) and differences (e.g., congestus paired with cirrus). The results could help inform development of cloud vertical overlap assumptions within operational numerical weather prediction models and potentially improve prediction of radiative fluxes for weather, climate, and renewable energy forecasting.

54 ENVIRONMENTAL SCIENCES↗

Using an Absolute Cavity Pyrgeometer to Validate the Calibration of a Secondary Standard Pyrgeometer Outdoors, Independent from the Reference Value of the Atmospheric Longwave Irradiance

Accurate measurements of broadband outdoor longwave irradiance are important for renewable energy applications and the study of the atmosphere and climate change. A unique method of pyrgeometer calibration has been developed to improve the measurement uncertainty [1]. The results of this method yielded irradiance values within ±3 W/m 2 of those traceable to the World InfraRed Standard Group (WISG). This article describes a technique for validating this pyrgeometer calibration method using two Absolute Cavity Pyrgeometers (ACPs). The ACPs and pyrgeometer model PIR were deployed outdoors and the irradiance measured by the PIR was compared against the average irradiance measured by the two ACPs. The irradiance measured by the PIR was calculated using two equations, NREL equation and the Physikalisch Meteorologisches Observatorium Davos (PMOD) equation. The uncertainty with 95% confidence level ( U 95 ) of the irradiance measured by the PIR using NREL equation equaled ±3.51 W/m 2 with respect to SI and using PMOD equation U 95 equaled ±2.99 W/m 2 with respect to SI. These results suggest that the PIR calibration method might be useful in addressing the international need for a secondary standard pyrgeometer traceable to SI.

54 ENVIRONMENTAL SCIENCES↗

What Is the Best Use of Biomass? A Harmonized LCA-TEA Framework Quantifying Economic and Environmental Metrics for Bioenergy Pathways

Bioresource utilization is expected to play a pivotal role in complementing existing energy pathways and enhancing energy resilience. This study develops a harmonized life cycle assessment (LCA) and techno-economic analysis (TEA) framework to evaluate the greenhouse gas (GHG) reduction potential, minimum fuel selling price (MFSP), and marginal abatement cost (MAC) of bioenergy pathways. We analyze 19 pathways, including liquid biofuels (via catalytic fast pyrolysis, Fischer–Tropsch synthesis, and gasification), bioelectricity, and biomass-to-hydrogen, with and without carbon capture and storage (CCS). The GHG impacts are assessed using the GREET 2022 model, while U.S. Billion-Ton 2016 biomass availability projections are used to estimate scale-up potential. Additionally, we evaluate the influence of a low-carbon electricity grid on pathway performance. Our results show that CCS implementation reduces carbon intensities (CI) to net-negative values for several pathways, with MAC ranging from $\$$32 to $\$$600 per metric ton (MT) CO2e avoided. Bioelectricity pathways with CCS achieve the lowest MAC ($\$$32–$\$$68/tCO2e), while liquid biofuels and hydrogen pathways remain critical for hard-to-abate sectors like aviation and heavy industry. Pathways with net-positive electricity demand benefit from a low-carbon grid, whereas those co-producing electricity experience increased MAC under lower electricity grid CI scenarios. This open-source framework provides a robust tool for harmonized evaluation of bioenergy pathways, enabling policymakers and stakeholders to identify cost-effective strategies for biomass utilization and carbon abatement at scale. The findings underscore the importance of CCS, co-product credits, and feedstock availability in optimizing bioenergy deployment for a low-carbon economy.

09 BIOMASS FUELS↗

Scaling Up CSP: How Long Will it Take?

Concentrating solar power (CSP) is one of the few scalable technologies capable of delivering dispatchable renewable power. Therefore, many expect it to shoulder a significant share of system balancing in a renewable electricity future powered by cheap, intermittent PV and wind power: the IEA, for example, projects 73 GW CSP by 2030 and several hundred GW by 2050 in its Net-Zero by 2050 pathway. In this paper, we assess how fast CSP can be expected to scale up and how long time it would take to get new, high-efficiency CSP technologies to market, based on observed trends and historical patterns. We find that to meaningfully contribute to net-zero pathways the CSP sector needs to reach and exceed the maximum historical annual growth rate of 30%/year last seen between 2010-2014 and maintain it for at least two decades. Any CSP deployment in the 2020s will rely mostly on mature existing technologies, namely parabolic trough and molten-salt towers, but likely with adapted business models such as hybrid CSP-PV stations, combining the advantages of higher-cost dispatchable and low-cost intermittent power. New third-generation CSP designs are unlikely to play a role in markets during the 2020s, as they are still at or before the pilot stage and, judging from past pilot-to-market cycles for CSP, they will likely not be ready for market deployment before 2030. CSP can contribute to low-cost zero-emission energy systems by 2050, but to make that happen, at the scale foreseen in current energy models, ambitious technology-specific policy support is necessary, as soon as possible and in several countries.

concentrated solar power↗

Highly Resolved Reference Projections of Building Energy Use for the Contiguous United States: Building Sector Energy Baselines, Projection Methods, and Results

This report describes one methodology of projecting energy consumption of the US residential and commercial building sectors using NREL's ResStock™ and ComStock™ as well as growth rates derived from EIA's Annual Energy Outlook (AEO). The impetus for this work is to provide an intermediate method for compiling demand-side sectoral energy projections that is suitable for grid-scale analysis, such as NREL's Standard Scenarios. ResStock and ComStock are physics-based and statistically representative building stock models of the US residential and commercial sector, respectively. Using the 2012 actual meteorological year (AMY) weather data, the sectoral energy baselines are simulated and then segmented along key dimensions (e.g., geography, dwelling/building type). The segmented results are then scaled using the corresponding annual growth rates derived from the 2021 AEO reference case to produce energy projections out to 2050. The compiled result is a demand-side grid model (dsgrid) data set suitable for use in NREL's large-scale grid models, such as the Regional Energy Deployment System (ReEDS). This simple projection method does not endogenously represent how the building stock could evolve through time. Most notably, it does not reflect large-scale electrification, for example, the conversion of space heating, water heating, clothes drying, and cooking from primary fossil fuels to electricity, as this is not part of AEO's reference case assumptions. Nonetheless this approach is more resolved and potentially extensible compared to the current method used by Standard Scenarios's reference case, which augments a sector's total load based on a single growth rate from AEO.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

AGGREGATE: dAta-driven modelinG preservinG contRollable dEr for outaGe mAnagemenT and rEsiliency (Final Report)

The AGGREGATE project team successfully developed and validated various modules for outage management. Brief summaries of each module are provided to showcase their strength for outage management and restoration for a distribution system with a high penetration of connected distribution energy resources (DERs). In recent years, inverter-based DERs have been widely deployed in distribution system. A most of behind-the-meter (BTM) solar power generation is not visible to the utility. The data-driven DER and load estimation modules are using machine learning (ML) and artificial intelligence (AI) to manage this issue, which provides an opportunity for distribution system operators (DSOs) to operate systems and make decisions in real-time for a distribution system with a high penetration of DERs deployed. Also, the estimated DER and true load can be further leveraged in network aggregation and cold-load pick up estimation for reducing the computing complexity and providing for fast restoration. After load demand and DER power generations have been estimated, the information will support topology and state estimation (SE). The topology estimation module demonstrated the viability of mixed integer linear programming (MILP) formulation to estimate the most likely operational radial topology and outage sections using power flow measurements, historical/estimated load and DERs data and smart meter ping measurements. Formulation includes continuous (power flow, load and DERs data) and binary measurements (smart meter ping measurements) in a single formulation. Errors in continuous data and binary data are modeled as normal distribution and Bernoulli distribution, respectively. In the future distribution grid, the power injection from controllable DERs will be essential for efficient and resilient grid operation. However, determining the optimal DER injections and restoration actions is dependent on knowledge of the system states. State estimation (SE), already the cornerstone of transmission energy management systems, will become commonplace in distribution management systems as more measurements become available from deployment of automated metering infrastructure (AMI). Observability analysis is the first step in SE, as it determines the sufficiency of the available measurements for accurately estimating the current system states. A new type of pseudo-measurement called a Correlational Measurement (CM) is introduced in this module, to enhance the observability of the system to enable more accurate SE. CMs encapsulate knowledge of correlation between demand patterns for similar classes of loads as well as injection patterns for same-technology renewable DERs. During grid contingency scenarios, DERs have been traditionally disconnected, without any fault ride-through capabilities. However, with new regulations and better technology, it is feasible for these resources to contribute to the grid’s restoration after an adverse event and hence enhance resilience. The controllability module proposes a two-step restoration scheme for the power system restoration process by leveraging additional degrees of freedom in power electronics interfaced DERs for mitigating voltage problems. In a resilience mode without the utility system, the distribution grid relies on DERs to serve critical load. In such a severe event with multiple faults on the distribution feeders, actuation of various protective devices (PDs) divides the distribution system into electrical islands. The undetected actuated PDs due to fault current contributions from DERs can delay the restoration process, thereby reducing the system resilience. The Advanced Outage Management (AOM) and the Advanced Feeder Restoration (AFR) modules developed in this project provide improved system resilience with multiple DERs. AOM identifies the faulted sections and actuated PDs in a distribution system with DERs by incorporating smart meter data. The most credible outage scenario including fault locations, PD actuations, and fault indicator (FI) failures is identified by a set of binary integer linear programming incorporating hypotheses. The AFR module serves to restore a distribution system with available energy resources taking into consideration the availability of utility sources and DERs. By partitioning the system into islands, critical load will be served with the available generation resources within islands based on the solution of a MILP. When the utility systems become available, the optimal path will be determined by a spanning tree search algorithm that reconnects these islands back to substations and restores the remaining load. The transmission and distribution (T&D) co-simulation module was used to validate the effect of a control action performed on the distribution side assets as it propagates to the transmission side. This ensures that the control action performed results in a feasible operating point on both the transmission and the distribution system. In addition to validation, the team used the T&D co-simulation module to demonstrate how distribution system assets can be used to mitigate issues on the transmission system. Specifically, the team demonstrated that appropriate switching operations on the distribution side can alleviate the line overload condition on the transmission side without causing new operational constraint violations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Predictive modeling of a subcritical pulverized-coal power plant for optimization: Parameter estimation, validation, and application

As renewable power generation deployment increases, fossil fuel plants are increasingly required to operate more flexibly. Many coal-fired power plants were originally designed to operate at base load and do not operate optimally at partial load. Predictive first-principles plant-wide models can be employed to identify opportunities for flexibility improvements and diagnose low-load operating issues. This paper describes the application of the Institute for the Design of Advanced Energy Systems Integrated Platform (IDAES) to model and optimize flexible power plant operations. The key benefits of using IDAES are that it provides an open-source, fully equation-oriented modeling framework for efficient modular model construction, reuse, and customization, together with a mathematical optimization framework leveraging powerful, state-of-the-art solvers. The process systems engineering workflow from predictive process simulation to parameter estimation, model validation, and plant optimization is applicable to a variety of existing and next-generation energy systems as well as other chemical and environmental processes. Here, to demonstrate this capability, a physics-based, steady-state model was developed to improve full- and part-load performance of the Escalante Generating Station, a 245 MWe (net) subcritical pulverized coal-fired power plant owned and operated by Tri-State Generation and Transmission Association. Specifically, sixty-nine model parameters were simultaneously estimated from several months of operating data enabling prediction of flow rates, temperatures, pressures, and steam quality throughout the plant. The validated model was leveraged by Escalante to reduce the minimum operating load from 90 MW to 50 MW by diagnosing a low-load water-hammer issue, enabling coal usage and emissions reductions during periods of low power demand. Additionally, opportunities for heat rate reduction (i.e., efficiency improvement) through a steeper sliding-pressure approach to load-following and optimization of other boiler operating variables were also identified and quantified. For example, a potential efficiency improvement of 0.7 percentage points was observed at half-load operation.

01 COAL, LIGNITE, AND PEAT↗

Developing Fluorescence-Based Sensors to Support Rare Earth Element Separation

Rare earth elements (REEs) are essential to most renewable energy technologies. Unfortunately, as we transition to sustainable energy production, the demand for REEs is rapidly growing well beyond current rates of production. As a result, novel means of efficient, scalable, and easily adaptable methods for processing primary and recycle feedstocks are needed. Development and integration of sensors for highly selective in-line monitoring can support more efficient design and testing of such novel separation processes, as well as more cost-effective deployment of those separation flowsheets. Work here will explore the application of fluorescence spectroscopy, a highly sensitive and selective technique, to quantify multiple lanthanides in complex mixtures including known interferents or quenching agents. Results include identification of the optimal excitation wavelength and the limit of detection of various rare earth elements as well as the performance of data-science-based quantification approaches in streams where “unknowns” are present. Overall, the data science tools in conjunction with optical sensor data were able to quantify analytes in the presence of other lanthanides which can be anticipated in the actual industrial stream. Here we include characterization of lanthanides in a microfluidic device similar to those used in new process development. This study demonstrates the capability of utilizing fluorescence spectroscopy to quantify analytes in a complicated solution matrix, suggesting this is a successful approach for in-line monitoring to optimize the separation efficiency in an industrial stream.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Grid Forming Control of PMSG-based Wind Turbines under Fault Conditions

Grid-forming control is widely envisioned as core technology ensuring stable operation of future power systems with increasing deployment of converter-interfaced renewable generation. However, research on grid forming control of wind turbines, especially under faults, is still in its early stages. In this context, this paper augments dual-port grid-forming control for type IV wind turbines with auxiliary controls to enable reliable fault ride through capabilities. In particular, the proposed control does not require a dc chopper or mode switching to grid-following control. Instead, energy-balancing dual-port GFM control is augmented with active rotor speed damping control and threshold virtual impedance for current limiting during faults. Different operating conditions of wind turbines are considered in a detailed electromagnetic transient simulation study to validate the effectiveness of the proposed control.

Lyu, Xue↗

Design, Development and Testing Plan for Energy Efficiency Algorithms Related to Building-Integrated Cooling, Heating, and Power Systems

Building-integrated cooling, heating and power (CHP) systems are more efficient than conventional systems at providing local power and thermal energy, and favorable fuel prices are bound to spur their increased adoption. It is estimated that the total CHP technical potential in the commercial building sector is approximately 76 GW, but only a small fraction of it is actually deployed. Advanced control and monitoring systems that realize the full potential of these CHP systems can transform this capacity into an asset for both the owner and the grid and also accelerate the adoption of these systems in the building sector. However, to realize the full benefit of the CHP systems, we must ensure persistence of energy efficient operations. It has been demonstrated by several studies that as much as 30% of building energy use is wasted. Much of the waste results from the inability to anticipate load variations (design day vs. non-design day operations; diurnal variation of loads), identify improper operation, and efficiently operate, control and maintain building systems. Moreover, many buildings, even those with adequate control infrastructure, lack knowledgeable staff to operate and maintain energy systems. Operators of buildings with CHP systems will constantly need to make tradeoffs (economic dispatch) between onsite power generation and purchasing power, between onsite heat production from distributed generation versus heating/cooling from conventional systems, and different passive and active load management measures. Much of the inefficiency in the current building operations can be eliminated by use of automated performance monitoring (PM), real-time commissioning verification (CxV) and automated fault detection and diagnostic (AFDD) tools. Automation can help system operators make intelligent decisions. Remote and continuous monitoring of system conditions and performance will enable better management and integration of CHP with existing building systems. Continuous PM, real-time CxV and AFDD could alleviate burdens for operations staff, enhance operations and maintenance (O&M), and improve reliability of building and CHP systems. To address the O&M challenges and to provide a means to maximize the rate-of-return of building-integrated CHP systems, the Building Technologies Office (BTO) within the U.S. Department of Energy’s (DOE’s) Office of Energy Efficiency and Renewable Energy (EERE) initiated a project to design, develop, and field test a VOLTTRON™-based supervisory controller and associated open-source algorithms. These algorithms will ensure real-time optimal operation of a building-integrated CHP system, support electric grid reliability, and lead to achieving the goal of a clean, efficient, reliable and affordable next-generation integrated energy systems. This report lists the components for which PM, real-time CxV and AFDD algorithms will be developed, how the algorithms will be tested, and metrics that will be used to validate the algorithms and easy of deployment. Deployment of these algorithms in the field will result in savings reduction in energy consumption of between 10% and 20%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Quantitative risk assessment examples for underground hydrogen storage facilities

Hydrogen energy storage can be used to achieve goals of national energy security, renewable energy integration, and grid resilience. Adapting underground natural gas storage facility (UNGSF) infrastructure for underground hydrogen storage (UHS) is one method of storing large quantities of hydrogen that has already largely been proven to work for natural gas. There are currently some underground salt caverns in the United States that are being used for hydrogen storage by commercial entities, but it is still a fairly new concept in that it has not been widely deployed nor has it been done with other geologic formations like depleted hydrocarbon reservoirs. Assessments of UHS systems can help identify and evaluate risks to people both working within the facility and residing nearby. This report provides example risk assessment methodologies and analyses for generic wellhead and processing facility configurations, specifically in the context of the risks of unintentional hydrogen releases into the air. Assessment of the hydrogen containment in the subsurface is also critically important for a safety assessment for a UHS facility, but those geomechanical assessments are not included in this report.

08 HYDROGEN↗

Space station architectural concepts and functional capability

Space program goals that NASA can best achieve by the construction of a space station in keeping with the 1958 directive to maintain U.S. pre-eminence in space technology are discussed. Science goals that can be satisfied by a suitable equipped space station include a deeper understanding of the earth/sun system and the earth as a planet, the acquisition of new data on the evolution of the solar system, of life, and of the universe, and the extended study of the laws governing the state of matter and energy. Application goals that can be pursued with a space station include assaying all renewable and nonrenewable earth resources, predicting environment, weather, and climatic changes, studying ocean dynamics, using space to develop new processes and materials, and using space for information transmission on a global basis. The space station can serve as a waypoint for voyages by manned or unmanned spacecraft, as a laboratory, observation platform, and technology proving station, and as a base for deployment and repair of other spacecraft.

Herman, D. H.↗

Development of an Interactive Valuation Model for Distributed Energy Resource Value: Cooperative Research and Development (Final Report)

The Oklahoma Office of the Secretary of Energy and Environment (OSEE) seeks to address perceived challenges and barriers to the deployment of distributed energy generation resources (DERs), including solar and other technologies, in the state of Oklahoma. The Scope of Work (SOW) associated with CRD-18-762 covers two tasks: (1) Interactive Valuation Model Requirements Document and (2) Consumer Protection Assessment. Follow-on work was completed under a separate CRADA (CRD-19-00788).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Global horizontal spectral irradiance and module spectral response measurements: an open dataset for PV research

This report describes the creation process and final content of a spectral irradiance dataset for Albuquerque, New Mexico accompanied by a set of spectral response measurements for modules deployed at the same location. The spectral irradiance measurements were made using horizontally mounted spectroradiometers; therefore, they represent global horizontal irradiance. The dataset combines non-continuous spectroradiometer and weather measurements from a two-year period into a single calendar year. The data files are accompanied by extensive metadata as well as example calculations and graphs to demonstrate the potential uses of this database. The spectral response measurements were carried out by the National Renewable Energy Laboratory using 12 commercial silicon modules types that are undergoing long-term evaluation at Sandia National Laboratories in Albuquerque.

14 SOLAR ENERGY↗

Re-evaluating the Thermal-Spectrum Molten-Salt Breeder Reactor Fuel Cycle in a Modern Context

The current need to rapidly and substantially expand clean power production combined with limited capability for domestic uranium enrichment results in a U.S. nuclear power production planning environment similar to that of the first nuclear era. The U.S. thermal-spectrum molten-salt breeder reactor (TS-MSBR) program emerged during the first nuclear era as means to support rapid nuclear power expansion while minimizing demand on fissile resources. The primary reasons that the TS-MSBR program was discontinued in the 1970s were the comparatively large amount of required effort to mature its technology sufficiently for commercial deployment and the access to separated fissile material provided by the design of its integrated fuel cycle. The slowdown in U.S. electrical load growth after 1980 and the abundance of inexpensive fossil fuels inhibited reconsideration of TS-MSBR development for decades. The purpose of this discussion is to re-examine the value and technical challenges of TS-MSBRs with integrated fuel salt chemical processing considering the renewed need for rapid expansion of clean energy production worldwide, the current state of technology, the challenge of actinide wastes, and the continuing need to maintain a high degree of proliferation resistance and to integrate safeguards into the design.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

EV Charging Infrastructure Energization An Overview of Approaches for Simplifying and Accelerating Timelines to Processing EV Charging Load Service Requests

The United States has seen significant growth in electric vehicle (EV) adoption, leading to increased demand for EV charging infrastructure. Over the past decade, EV charging infrastructure site developers, site hosts, and electric distribution utilities have navigated the process to integrate chargers onto the electric grid. Site developers and site hosts have raised the alarm that the integration process for high-powered EV charging projects does not meet the needs of the EV market for timeliness or cost. High-powered charging stations typically require a load service request or an agreement with the local utility to connect to the grid. The process of energizing a new high-powered charging site can be complex and time-consuming, often taking up to 2 years. This timeline is the result of current utility energization processes having been designed for construction projects that take longer to build (i.e., buildings). The specific challenges stem from various factors, including compartmentalization in application processes, the integration of EV charging process approvals with other distributed energy resources (DERs), and the need to ensure grid reliability. The energization process needs to evolve to meet the growing demand for high-powered EV charging. This white paper compiles information gathered through various conversations with key stakeholders, including utilities, utility regulators, EV charging operators, site developers, and authorities having jurisdiction (AHJ) as well as through an extensive literature review. This document identifies the challenges and provides potential solutions to streamline the process of connecting EV charging infrastructure to the power grid in the United States, serving as a starting point for future conversations around these solutions. The solutions noted in this white paper require collaborative efforts among utilities, regulators, and EV charging infrastructure developers to streamline the grid connection process for EV charging infrastructure. They are broadly organized into four areas: 1. Increase data access and transparency: Develop automated load service request tools, integrate hosting capacity and load service request analyses, incorporate EV adoption forecasts, and provide transparency on the processing queue. 2. Improve energization processes and timing: Create fast-track options based on prescreening criteria, provide flexibility or phased approvals in the load service request/interconnection process, build internal knowledge within utilities about EV charging technologies, and provide standardized workforce training. 3. Promote economic efficiency: Right size distribution components to accurately reflect the load requirements of EV charging infrastructure, make proactive investments in grid infrastructure based on EV adoption forecasts and growth projections, and consider energy equity and environmental justice factors such as equitable access to EV charging when planning infrastructure. 4. Improve grid reliability and resilience: Use load management/power control systems (PCS) at EV charging stations, adopt and implement harmonized standards for communication protocols and information models between the EV charging and grid control infrastructure, and address cybersecurity considerations by implementing robust security measures and standards for EV charging infrastructure—with particular emphasis on clarifying the security requirements for the interface to the grid. The objective of the solutions proposed in this white paper is to accelerate the timeline and decrease costs associated with connecting EV charging infrastructure to the grid. Electric utilities, utility regulators, EV charging infrastructure developers, and site hosts will first need to understand which solutions are available in their service territory, and if warranted, which combination of solutions would support their specific needs. Through the successful implementations of solutions at scale detailed here, industry will demonstrate a new and innovative ecosystem where timely deployment and energization of EV charging infrastructure with greater grid resiliency and reliability is a reality.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Senior Housing Complex Energy Efficiency and Solar Energy Project

As part of a longer-term energy efficiency and solar development program on the Coeur d'Alene reservation, the Coeur d'Alene Tribe completed energy efficiency measures and deployed a solar photovoltaic system at its Senior Housing Complex. The project generated nearly 68,000 kWh of solar energy in its first year, and reduced energy used at the senior housing complex by 95,192 kWh, saving $7,144.56 in energy costs, and saving 48.1 metric tons of carbon dioxide.

14 SOLAR ENERGY↗