Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “radiometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Very high resolution radiometer

A very high resolution radiometer is reported that produces visible and infrared images onboard meteorological satellites. The device has a visible and an infrared channel, a resolution in both spectral bands of 0.9260 kilometers from a 1460 kilometer polar orbit, and scans from horizon to horizon. A two stage radiant cooler with cooled outer housing permits operation in the 100 degrees kelvin range.

Schulman, J. R.↗

Meteorological interpretations of the images from Nimbus 5 electrically scanned microwave radiometer

The Electrically Scanned Microwave Radiometer on the Nimbus 5 satellite measures microwave radiation in a band centered at 1.55 cm. It scans perpendicular to the satellite motion from 50 deg to the left to 50 deg to the right in the 78 steps every 4 seconds producing an image with a best resolution of 25 km. It is shown that these images can be used to delineate areas of rain over the oceans. This data can be used to approximate the location of fronts, the rain/snow boundary and secondary cyclogenesis.

Wilheit, T.↗

Active cavity radiometer.

The active cavity radiometer (ACR) is a pyrheliometer that accurately defines the absolute radiation scale. The physics of the pyrheliometric method and the ACR approach to this method are presented in detail. A mathematical abstraction of the method is generated through a quasi-equilibrium analysis of the power balance of the ACR's cavity detector. An error analysis is carried out on the quasi-equilibrium equation to determine the uncertainties of ACR measurements relative to the absolute radiation scale. The uncertainty of ACR measurements as a function of irradiance level is presented in graphical form.

Willson, R. C.↗

A multispectral study of an extratropical cyclone with Nimbus 3 medium resolution infrared radiometer data

Four registered channels (0.2 to 4, 6.5 to 7, 10 to 11, and 20 to 23 microns) of the Nimbus 3 Medium Resolution Infrared Radiometer (MRIR) were used to study 24-hr changes in the structure of an extratropical cyclone during a 6-day period in May 1969. Use of a stereographic-horizon map projection insured that the storm was mapped with a single perspective throughout the series and allowed the convenient preparation of 24-hr difference maps of the infrared radiation fields. Single-channel and multispectral analysis techniques were employed to establish the positions and vertical slopes of jetstreams, large cloud systems, and major features of middle and upper tropospheric circulation. Use of these techniques plus the difference maps and continuity of observation allowed the early detection of secondary cyclones developing within the circulation of the primary cyclone. An automated, multispectral cloud-type identification technique was developed, and comparisons that were made with conventional ship reports and with high-resolution visual data from the image dissector camera system showed good agreement.

Holub, R.↗

Monitoring atmospheric pollutants with a heterodyne radiometer transmitter-receiver

The presence of selected atmospheric pollutants can be determined by transmitting an infrared beam of proper wavelength through the atmosphere, and detecting the reflections of the transmitted beam with a heterodyne radiometer transmitter-receiver using part of the laser beam as a local oscillator. The particular pollutant and its absorption line strength to be measured are selected by the laser beam wave length. When the round-trip path for the light is known or measured, concentration can be determined. Since pressure (altitude) will affect the shape of the molecular absorption line of a pollutant, tuning the laser through a range of frequencies, which includes a part of the absorption line of the pollutant of interest, yields pollutant altitude data from which the altitude and altitude profile is determined.

Menzies, R. T.↗

Infrared scanning radiometer

The Apollo 17 infrared scanning radiometer (ISR) experiment for mapping lunar surface thermal emission is reported. The instrument, lunar surface coverage, and the data obtained are discussed.

Low, F. J.↗

Steady state thermal radiometers

A radiometer is described operating in a vacuum under steady state conditions. The front element is an aluminum sheet painted on the outer side with black or other absorptive material of selected characteristics. A thermocouple is bonded to the inner side of the aluminum sheet. That is backed by highly insulative layers of glass fiber and crinkled, aluminized Mylar polyester. Those layers are backed with a sturdy, polyester sheet, and the entire lamination is laced together by nylon cords. The device is highly reliable in that it does not drift out of calibration, and is significantly inexpensive.

Loose, J. D.↗

Surface composition mapping radiometer instrument

The design, development, and fabrication of a three-channel scanning radiometer are discussed. The instrument was flown on Nimbus 5 satellite and measured infrared energy in the 8.3 to 9.3, 10.2 to 11.2, and 0.8 to 1.1 micron spectral regions. The instrument parameters are presented. Theoretical discussions of the instrument subassemblies are provided. Operational details of the mechanical and electrical portions of the instrument are included.

Source record↗

A filter-wheel solar radiometer for atmospheric transmission studies

A filter-wheel solar radiometer has been developed for monitoring the atmospheric optical depth at multiple narrow-wavelength intervals in the visible and near IR regions of the spectrum. Measurements of the direct solar radiations are converted to a digital format and stored in punched tape for eventual analysis by a computer. During stable clear weather condition, the instrument is capable of providing monochromatic optical depths to an estimated rms accuracy of 0.005.

Shaw, G. E.↗

Design and performance characteristics of the vertical temperature profile radiometer /VTPR/ for atmospheric temperature soundings

Various design characteristics and performance achievements of the vertical temperature profile radiometer (VTPR) are discussed. It is shown that the VTPR provides a relative calibration accuracy of better than 0.1% rms of the full dynamic range and has been operating successfully in space on the ITOS spacecraft for more than eleven months. The absolute accuracy achievable between in-flight calibrations of 6 minutes, or between 2-hour calibrations using optical temperature correction factors, is better than an rms value of 0.15% of full scale. The radiometric correlation between the VTPR in-flight calibration source and a reference standard blackbody is better than an rms value of 0.5% of full scale.

Falbel, G.↗

Air pollution - Remote detection of several pollutant gases with a laser heterodyne radiometer

An infrared heterodyne radiometer with a spectral resolution of 0.04 reciprocal centimeters has been used to remotely detect samples of ozone, sulfur dioxide, ammonia, and ethylene at room temperature, and samples of nitric oxide at 390 K. Each gas was observed in a background of nitrogen or oxygen at atmospheric pressure. Sensitivities to some of these gases are adequate for detection of ambient concentrations as low as a few parts per billion.

Menzies, R. T.↗

Microwave radiometer measurements of the Cape Cod Canal

Microwave radiometer measurements were conducted from a railroad bridge which spans the Cape Cod Canal in Massachusetts. Data were collected as a function of viewing angle and polarization at frequencies of 1.4, 4.0, and 7.5 GHz. The results compare differences in the microwave emmissivity of a smooth vs rough water surface. Results are also given which show the effects of roughness on the bistatic scattering of sunlight.

Swift, C. T.↗

Remote sensing of soil moisture by Skylab radiometer and scatterometer sensors

A Skylab experiment was designed to evaluate the feasibility of monitoring the moisture content of the soil from space. Data from various Skylab sensors were collected across two test sites while direct measurements of soil moisture were being made at the surface depths of soil. Correlations were obtained between the moisture content of the soil and radiometer sensors (S193 and S194) and the scatterometer instrument (S193). The high correlations obtained indicate that microwave sensors may be quite useful for such measurements in the future.-

Eagleman, J. R.↗

Development and testing of the infrared radiometer for the Mariner Venus/Mercury 1973 spacecraft

The science objectives, development history, functional description, and testing of the Mariner Venus/Mercury 1973 infrared radiometer are discussed. Included in the functional description section is a thorough discussion of the IRR optical system, electronic operation, and thermal control. Signal development and its conversion to engineering units is traced, starting with the radiant space object, passing through the IRR optics and electronics, and culminating with data number development and interpretation. The test program section includes discussion of IRR calibration and alignment verification. Finally, the problems and failures encountered by the IRR during the period of its development and testing are reviewed.

Clarke, T. C.↗

Skylab program: Earth resources experiment package. Sensor performance evaluation. Volume 6: (S194) L-band radiometer

Analysis of the Skylab S194 L-band radiometer experiment data provided significant results pertaining to the actual realized performance during flight. Analysis of preflight test data provided a baseline from which to compare the experiment flight performance, although many radiometric data performance capabilities could only be demonstrated in the flight environment. The final results establish the overall hardware performance of the S194 system from which prospective users of the flight data can refer for various scientific applications. Instrument performance is presented in the areas of housekeeping and internal calibration parameters, antenna system integrity, dynamic range, linearity, precision, resolution, and absolute accuracy. Supplementary evaluations were included for an error analysis of system calibration stability. Results of the evaluation show that the instrument performance was generally as expected. Conclusions are drawn from the final evaluation results, and recommendations for improving the effectiveness of a future program are offered.

Kenney, G. P.↗

The polarimeter and the multispectral radiometer as remote probes of aerosols

Attempts made to establish the viability of the polarimeter as a ground based remote probe of atmospheric aerosols under varying meteorological conditions are reported. Extension radiometer data are also given and a comparison was made with polarimeter data to determine if one could complement/supplement the other. The analyses show that the two instruments are complementary devices and any information obtained from one will greatly facilitate the analysis of the other. Detailed results are given in graphical form.

Kuriyan, J. G.↗

A survey of ATL-compatible radiometer antennas

A survey was made of antennas suitable for remote sensing of the earth's surface, in particular the world ocean, by means of microwave radiometers operating in the 1 to 26 GHz frequency region and carried on board the shuttle-launched advanced technology laboratory. Array antennas are found to be unattractive and unsuited to the task. Reflectors, including Cassegrain and offset types, as well as horn-reflectors are possible candidates but all have shortcomings which impair the accuracy of measurement. Horns of the corrugated type have excellent electrical characteristics. Although they are physically very large and will require development of suitable deployment mechanisms, they appear to be valid candidates for the task. The evolution of the periscope antenna is outlined, and it is shown to possess nearly ideal electrical characteristics for the intended application. Its only shortcoming is that the feed horn creates aperture blocking; there is no blocking due to struts or any other source. The periscope antenna is recommended for ATL radiometry.

Love, A. W.↗