Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “quantitative”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Quantitative Pointwise Estimate of the Solution of the Linearized Boltzmann Equation

We study the quantitative pointwise behavior of the solutions of the linearized Boltzmann equation for hard potentials, Maxwellian molecules and soft potentials, with Grad’s angular cutoff assumption. More precisely, for solutions inside the finite Mach number region (time like region), we obtain the pointwise fluid structure for hard potentials and Maxwellian molecules, and optimal time decay in the fluid part and sub-exponential time decay in the non-fluid part for soft potentials. For solutions outside the finite Mach number region (space like region), we obtain sub-exponential decay in the space variable. The singular wave estimate, regularization estimate and refined weighted energy estimate play important roles in this paper. Our results extend the classical results of Liu and Yu (Commun Pure Appl Math 57:1543–1608, 2004), (Bull Inst Math Acad Sin 1:1–78, 2006), (Bull Inst Math Acad Sin 6:151–243, 2011) and Lee et al. (Commun Math Phys 269:17–37, 2007) to hard and soft potentials by imposing suitable exponential velocity weight on the initial condition.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantitative Boltzmann–Gibbs Principles via Orthogonal Polynomial Duality

We study fluctuation fields of orthogonal polynomials in the context of particle systems with duality. We thereby obtain a systematic orthogonal decomposition of the fluctuation fields of local functions, where the order of every term can be quantified. This implies a quantitative generalization of the Boltzmann–Gibbs principle. In the context of independent random walkers, we complete this program, including also fluctuation fields in non-stationary context (local equilibrium). For other interacting particle systems with duality such as the symmetric exclusion process, similar results can be obtained, under precise conditions on the n particle dynamics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

RAPID QUANTITATION OF URANIUM FROM MIXED FISSION PRODUCT SAMPLES

Chemical similarities between U(VI) and Mo(VI) create challenges for separation and quantification of uranium from a mixed fission product sample. The purpose of this work was to demonstrate the feasibility of using Eichrom’s® UTEVA resin in addition to a tellurium spontaneous deposition to improve the quantitation of 235U using gamma spectroscopy. The optimized method demonstrated a consistent chemical yield of 74 ± 3 % for uranium. This procedure was evaluated using 1.41x1012 fissions produced from an irradiated HEU sample. The uranium was isotopically yielded by HPGe, and the minimum detectable activity (MDA) determined from the gamma spectra. The MDA for 235U, 237U, and 238U was reduced by a factor of two. The chemical isolation of uranium was successfully achieved in less than four hours, with a separation factor of 1.41x105 from molybdenum.

Haney, Morgan M.↗

A quantitative assessment of (bacterio)chlorophyll assignments in the cryo-EM structure of the Chloracidobacterium thermophilum reaction center

Chlorophylls and bacteriochlorophylls are the primary pigments used by photosynthetic organisms for light-harvesting, energy transfer, and electron transfer. Many molecular structures of (bacterio)chlorophyll-containing protein complexes are available, some of which contain mixtures of different (bacterio)chlorophyll types. Differentiating these, which sometimes are structurally similar, is challenging but is required for leveraging structural data to gain functional insight. The reaction center complex from Chloroacidobacterium thermophilum has a hybrid (bacterio)chlorophyll antenna system containing both chlorophyll a and bacteriochlorophyll a molecules. The recent availability of its cryogenic electron microscopy (cryo-EM) structure provides an opportunity for a quantitative analysis of their identities, and chemical environments. Here, we describe a theoretical basis for differentiating chlorophyll a and bacteriochlorophyll a in a cryo-EM map, and apply the approach to the experimental cryo-EM maps of the (bacterio)chlorophyll sites of the chloroacidobacterial reaction center. The comparison reveals that at ~2.2-Å resolution, chlorophyll a and bacteriochlorophyll a are easily distinguishable, but the orientation of the bacteriochlorophyll a acetyl moiety is not; however, the latter can confidently be assigned by identifying a hydrogen bond donor from the protein environment. Furthermore, this study reveals the opportunities and challenges in assigning (bacterio)chlorophyll types in structural biology, the accuracy of which is vital for downstream investigations.

59 BASIC BIOLOGICAL SCIENCES↗

Quantitative In Situ Studies of Dynamic Fracture in Brittle Solids Using Dynamic X-ray Phase Contrast Imaging

Here, we demonstrate the use of X-ray phase contrast imaging with sub-microsecond temporal resolution to obtain quantitative visualization of dynamic fracture processes in brittle solids. We examine an amorphous solid (fused silica), a ceramic single crystal (single-crystal quartz), and a polycrystalline ceramic (boron carbide), in the form of single-edge notched specimens loaded using a three-point apparatus at nominal strain rates up to ~800 s -1 . We observe that the crack tip speed for boron carbide is relatively independent of mode I stress intensity factor rate ($\dot{K}$ I ) for these rates of loading, while that of fused silica and single-crystal quartz increases with $\dot{K}$ I . Further, for the amorphous and single crystal cases, we observe the development of a crack tip instability in the form of crack branching as the crack tip speed approaches 45% of the Rayleigh wave speed. This suggests that strain-rate-dependent mechanisms contribute to crack branching. Such mechanisms may, in turn, affect the macroscopic fracture properties of these materials.

36 MATERIALS SCIENCE↗

Quantitative Comparison of Ternary Eutectic Phase-Field Simulations with Analytical 3D Jackson–Hunt Approaches

For the analytical description of the relationship between undercoolings, lamellar spacings and growth velocities during the directional solidification of ternary eutectics in 2D and 3D, different extensions based on the theory of Jackson and Hunt are reported in the literature. Besides analytical approaches, the phase-field method has been established to study the spatially complex microstructure evolution during the solidification of eutectic alloys. The understanding of the fundamental mechanisms controlling the morphology development in multiphase, multicomponent systems is of high interest. For this purpose, a comparison is made between the analytical extensions and three-dimensional phase-field simulations of directional solidification in an ideal ternary eutectic system. Based on the observed accordance in two-dimensional validation cases, the experimentally reported, inherently three-dimensional chain-like pattern is investigated in extensive simulation studies. The results are quantitatively compared with the analytical results reported in the literature, and with a newly derived approach which uses equal undercoolings. A good accordance of the undercooling–spacing characteristics between simulations and the analytical Jackson–Hunt apporaches are found. The results show that the applied phase-field model, which is based on the Grand potential approach, is able to describe the analytically predicted relationship between the undercooling and the lamellar arrangements during the directional solidification of a ternary eutectic system in 3D.

36 MATERIALS SCIENCE↗

Examination of Dendritic Growth During Solidification of Ternary Alloys via a Novel Quantitative 3D Cellular Automaton Model

A three-dimensional (3D) quantitative cellular automaton (CA) model was developed to simulate dendritic growth during solidification processing of ternary alloys. A detailed method was proposed to solve solute diffusion and calculate the solid fraction for ternary alloys during solidification. The present model has been shown to accurately predict dendrite morphologies and solute distributions of both single equiaxed dendrite and columnar dendrites during solidification. The model was also used to study the influence of the concentration of a third component (Mg in the Al-Si-Mg system) on dendritic growth. With increasing Mg concentration, the steady-state dendrite tip growth velocity was shown to decrease, resulting in a shorter primary dendrite length. The 3D CA simulation results agree well with the prediction of the LGK theoretical model. Multi-columnar dendrite growth was simulated with different cooling rates. Primary and secondary dendrite morphology was shown to have little variation at low cooling rates (1.0 to 2.0 K/s) and a constant undercooling. The average secondary dendrite arm spacing was shown to decrease with the increase of cooling rate within this range. The 3D CA simulation results are in good agreement with the experimental directional solidification experiments of a commercial A356 (Al-7 wt pct Si-0.3 wt pct Mg).

36 MATERIALS SCIENCE↗

Quantitative Evaluations of Surface Cleanliness in IF Steel Slabs at Unsteady Casting

Macro-inclusions in the surface layer of slabs are mainly responsible for the sliver defects in IF steel sheets. In the present work, macro-inclusions in six kinds of unsteady cast IF steel slabs involving four unsteady states (casting start, ladle change, nozzle change and casting end) in one casting sequence were quantitatively characterized using an automatic inclusion analyzer with a total detection area of 238,048 mm{sup 2}. The cleanliness of corresponding normal slabs was also evaluated as the benchmark study, and the number density (ND) of inclusions > 50 µm was used to describe the surface slab cleanliness. Generally, alumina-based and mold powder inclusions were detected, and the former type was further subdivided into alumina clusters, alumina associated with bubbles, refractory-related alumina, Al-Ti complex oxides and CaO-Al{sub 2}O{sub 3}-MgO. Several large-sized alumina-based inclusions were detected in the normal slabs with an average ND of 0.31 N/cm{sup 2}, although they had very low total oxygen (TO) contents (10~13 ppm). No mold powder inclusions were found in normal slabs. For all the unsteady slabs, alumina-based and mold powder inclusions were both observed, and the percentage of the former kind was ≥ 90 pct. The average density of macro-inclusions for the first slab was 1.621 N/cm{sup 2}, whose cleanliness was much worse than any of the other unsteady slabs. The first slab should be downgraded. For the second slab, the ND of macro-inclusions was 0.385 N/cm{sup 2}, which was still larger than the normal slabs because of the lasting effect of the re-oxidation. For the penultimate, cap-off and SEN changed slabs, the density of macro-inclusions fluctuated from 0.25~0.35 N/cm{sup 2}, which was close to the average level of normal slabs. However, mold flux-originated inclusions were frequently observed in these slabs because of flow pattern variations due to the casting speed change. In terms of the slab during the ladle change process, mold powder inclusions were frequently detected even though the casting speed remained constant. A mold powder entrapment mechanism was proposed, which showed the entrapment occurred owing to the flow pattern change induced by forming/dropping of SEN clogs due to re-oxidation by FeO in the ladle slag and tundish steel temperature variations during the ladle change practice. The severity of powder entrapment and re-oxidation was also given for different kinds of unsteady slabs, which provides a direct guide to treating these slabs in the steel plant.

36 MATERIALS SCIENCE↗

A Technique for the Quantitative Characterization of Weld Microstructure and Application to Mo Welds

The choice of weld parameters determines the size, shape, and curvature of grains in the fusion zone (FZ) and heat-affected zone (HAZ) of welds while the mechanical properties of the welds are correlated to this microstructure. Here, a new technique to quantitatively evaluate these microstructural characteristics in both zones of welds has been applied to molybdenum gas tungsten arc welds fabricated using different weld parameters. Trends in microstructural characteristics in the FZ and HAZ were evaluated and correlated with changes to heat input, weld speed, and weld technique. The use of this approach showed that a 20 pct decrease in heat input caused a 20 pct decrease in the number of FZ grains with aspect ratios ≥ 4. The orientations of the FZ grain segments as a function of distance from the FZ centerline were significantly affected by the weld speed and its effect on weld pool shape. A 50 pct increase in weld speed caused a 20 pct decrease in grain segments orientated 60 to 90 deg from the normal to the direction of welding. This technique also captured differences in grain sizes and grain size anisotropy in the FZ between welds made with a constant current, pulsed current, and use of a 4-pole-magnetic oscillator.

36 MATERIALS SCIENCE↗

Quantitative trait loci (QTL) underlying biomass yield and plant height in switchgrass

Switchgrass (Panicum virgatum L.) biomass yield and feedstock quality improvement are priority research areas for bioenergy feedstock development. Identification of quantitative trait loci (QTL) underlying these traits and of trait-linked markers for application in marker-assisted selection (MAS) is of paramount importance in facilitating switchgrass breeding. Detection of QTL for biomass yield and plant height was conducted on parental linkage maps constructed using a heterozygous pseudo-F-1 population derived from a cross between lowland Alamo genotype AP13 and upland Summer genotype VS16. QTL analysis was performed with composite interval mapping. Four QTL for biomass yield and five QTL for plant height were identified using best linear unbiased predictors across ten and eight environments, respectively. The phenotypic variability explained (PVE) by QTL detected in the across environments analysis ranged from 4.9 to 12.4 % for biomass yield and 5.1 to 12.0 % for plant height. A total of 34 and 38 main effect QTL were detected for biomass yield and plant height, respectively, when data from each environment were analyzed separately. The PVE by individual environment QTL ranged from 3.3 to 15.3 % for biomass yield and from 4.3 to 17.4 % for plant height. In addition, 60 and 51 epistatic QTL were detected for biomass yield and plant height, respectively. Significant QTL by environment interactions were detected for QTL mapped in eight genomic regions for each of the two traits. Seven QTL affected both traits and may represent pleiotropic loci. Overall, 11 genomic regions were identified that were important in controlling biomass yield and/or plant height in switchgrass. Furthermore, the markers linked to the main effect and epistatic QTL may be used in MAS to maximize selection gain in switchgrass breeding, leading to a faster development of better biofuel cultivars.

09 BIOMASS FUELS↗

Corrected coronary opacification decrease from coronary computed tomography angiography: Validation with quantitative 13N-ammonia positron emission tomography

Background: To assess the functional relevance of a coronary artery stenosis, corrected coronary opacification (CCO) decrease derived from coronary computed tomography angiography (CCTA) has been proposed. The present study aims at validating CCO decrease with quantitative 13N-ammonia positron emission tomography (PET) myocardial perfusion imaging (MPI). Methods and Results: This retrospective study consists of 39 patients who underwent hybrid CCTA/PET-MPI. From CCTA, attenuation in the coronary lumen was measured before and after a stenosis and corrected to the aorta to calculate CCO and its decrease. Relative flow reserve (RFR) was calculated by dividing the stress myocardial blood flow (MBF) of a vessel territory subtended by a stenotic coronary by the stress MBF of the reference territories without stenoses. RFR was abnormal in 11 vessel territories (27%). CCO decrease yielded a sensitivity, specificity, negative predictive value, positive predictive value, and accuracy for prediction of an abnormal RFR of 73%, 70%, 88%, 47%, and 70%, respectively. Conclusions: CCTA-derived CCO decrease has moderate diagnostic accuracy to predict an abnormal RFR in PET-MPI. However, its high negative predictive value to rule out functional relevance of a given lesion may confer clinical implications in the diagnostic work-up of patients with a coronary stenosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

{sup 18}F-FDG PET/CT-imaging of left ventricular assist device infection: a retrospective quantitative intrapatient analysis

Background: Despite the use of {sup 18}F-fluorodeoxyglucose ({sup 18}F-FDG) positron emission tomography/computed tomography (PET/CT), diagnosis of a driveline infection in ventricular assist device (LVAD) recipients remains challenging. Our aim was to evaluate the potential of a baseline {sup 18}F-FDG PET/CT (prior to an infection) for the diagnosis of an LVAD-related infection. Methods: We retrospectively selected all LVAD recipients who had undergone two consecutive whole-body {sup 18}F-FDG PET/CT examinations between January 2010 and December 2016. PET/CT was analyzed qualitatively (uptake pattern) and semi-quantitatively (SUV{sub max} and ∆SUV{sub max}). SUV{sub max} was measured and compared in five distinctive volumes of interest along the LVAD driveline. An SUV{sub max} threshold was calculated. Final diagnosis was made by clinical examination, microbiological parameters, and molecular imaging. Results: Thirty patients were enrolled (mean age 54 ± 12 years; 26 male). Mean difference in SUV{sub max} for all five positions between the first and the second PET/CT along the driveline was significantly higher in patients with an LVAD-related infection (mean ∆SUV{sub max} = 4.38 ± 1.44) compared to those without a driveline infection (mean ∆SUV{sub max} = 0.03 ± 0.43), P < 0.05. Applying ROC analysis, an SUV{sub max} threshold of 3.88 resulted in a sensitivity and specificity of 100%, respectively. There were three distinctive uptake patterns in patients with a driveline infection. Conclusion: PET/CT diagnosis in the context of an LVAD-related infection can be improved by comparison to a baseline examination using a distinctive SUV{sub max} threshold.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantitative Collision Cross-Sections from FTICR Linewidth Measurements: Improvements in Theory and Experiment

Two corrections to the equation used in the cross-sectional areas by Fourier transform ion cyclotron resonance (“CRAFTI”) technique are identified. In CRAFTI, ion collision cross-sections are obtained from the pressure-dependent ion linewidths in Fourier transform mass spectra. The effects of these corrections on the accuracy of the cross-sections obtained using the CRAFTI technique are evaluated experimentally using the 20 biogenic amino acids and several crown ether complexes with protonated alkyl monoamines. Good absolute agreement is obtained between the CRAFTI cross-sections and the corresponding cross-sections obtained using both static drift ion mobility spectrometry and computational simulations. These results indicate that the CRAFTI cross-sections obtained using the updated equation presented here are quantitatively descriptive of the size and shape of the gas-phase ions. Cross-sections that differ by less than 3% are measured for the isobaric isomers n-butylamine and tert-butylamine complexed with the crown ethers. This level of precision is similar to what has been achieved previously using traveling wave ion mobility devices. These results indicate that CRAFTI can be used to probe subtle structural differences between ions with approximately the same precision as that achieved in traveling wave ion mobility devices. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved Quantitative Dynamic Range of Time-of-Flight Mass Spectrometry by Simultaneously Waveform-Averaging and Ion-Counting Data Acquisition

Two different types of data acquisition methods, “averaging mode” and “ion-counting mode”, have been used in a time-of-flight (TOF) mass spectrometry. The most common method is an averaging mode that sums waveform signals obtained from each flight cycle. While it is possible to process many ions arriving at the same TOF in one flight cycle, low-abundance ions are difficult to measure because ion signals are overwhelmed by noises from the detection system. An ion-counting mode is suitable for the detection of such low-concentration ions, but counting loss occurs when two or more ions arrive at the detector within the dead time of the acquisition system. In this study, we introduce a technique that combines two methods to measure target ions with a high concentration difference, i.e., averaging mode and ion-counting mode are used simultaneously for high abundant and trace ions, respectively. By processing waveforms concurrently during data acquisition, one can choose to analyze either or both types of data to achieve a highly quantitative mass spectrum over a wide range of sample concentrations. The result of the argon isotope analysis shows that this method provides a more accurate determination of the isotope ratio compared to averaging mode alone at one-twentieth of the analysis time required by ion-counting alone. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Large-Area Graphene Films as Target Surfaces for Highly Reproducible Matrix-Assisted Laser Desorption Ionization Suitable for Quantitative Mass Spectrometry

Due to the known sweet-spot issues that intrinsically arise from inhomogeneous formation of matrix-analyte crystals utilized as samples in matrix-assisted laser desorption ionization (MALDI) mass spectrometry, its reproducibility and thus its applications for quantification have been somewhat limited. In this paper, we report a simple strategy to improve the uniformity of matrix-analyte crystal spots, which we realized by adapting large-area graphene films, i.e., non-inert, interacting surfaces, as target surfaces. In this example, the graphitic surfaces of the graphene films interact with excess matrix molecules during the sample drying process, which induces spontaneous formation of optically uniform MALDI sample crystal layers on the film surfaces. Further, mass spectrometric imaging reveals that the visible uniformity is indeed accompanied by reproducible MALDI ionization over an entire sample spot, which greatly suppresses the appearance of sweet spots. The results of this study confirm that the proposed method achieves good linear responses of ion intensity to the analyte concentration (R{sup 2} > 0.99) with small relative standard deviations (σ < 10%), which is a range applicable for quantitative measurements using MALDI mass spectrometry. .

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A General Materials Data Science Framework for Quantitative 2D Analysis of Particle Growth from Image Sequences

Abstract Phase transformations are a challenging problem in materials science, which lead to changes in properties and may impact performance of material systems in various applications. We introduce a general framework for the analysis of particle growth kinetics by utilizing concepts from machine learning and graph theory. As a model system, we use image sequences of atomic force microscopy showing the crystallization of an amorphous fluoroelastomer film. To identify crystalline particles in an amorphous matrix and track the temporal evolution of the particle dispersion, we have developed quantitative methods of 2D analysis. 700 image sequences were analyzed using a neural network architecture, achieving 0.97 pixel-wise classification accuracy as a measure of the correctly classified pixels. The growth kinetics of isolated and impinged particles were tracked throughout time using these image sequences. The relationship between image sequences and spatiotemporal graph representations was explored to identify the proximity of crystallites from each other. The framework enables the analysis of all image sequences without the requirement of sampling for specific particles or timesteps for various materials systems.

36 MATERIALS SCIENCE↗

Quantitative Comparisons of Image Quality for Flash X-Ray Detectors

Due to X-rays’ ability to penetrate materials, flash X-ray radiography can be used for high-speed measurements where direct optical access is not possible. Choice of detector has a pronounced impact on resulting image quality. Four different detector systems were evaluated with a 450kVp flash source to quantitatively compare image quality metrics. The scintillating digital detector had less image noise than the three different storage phosphor computed radiography detectors across all transmission levels, but lacked the spatial resolution of the computed radiography detectors. For the screens tested here, the HPX-DR digital system had the highest signal to noise ratio of 68.24 and contrast to noise ratio of 35.53, but had the lowest spatial resolution, resolving 2.5 line pairs per millimeter at 1.78% contrast. At a value of 37.59, the Flex GP imaging plate had a signal to noise value above its storage phosphor counterparts under a 450kVp flash source. For radiographic setups typically used for dynamic experiments, the Flex XL Blue and Flex HR detectors had signal to noise ratios of 18.44 and 26.56 respectively. The highest resolved spatial frequencies of the Flex GP, Flex XL Blue, and Flex HR with the flash source are 3.85, 5.00, and 3.85 line pairs per millimeter, respectively. In conclusion, the Flex GP detector had the best combination of signal to noise ratio, contrast to noise ratio, and spatial resolution under a flash source.

computed radiography↗