Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power system simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Advanced Features and Recent Developments in the WEC-Sim Open-Source Design Tool: Preprint

WEC-Sim is an open-source tool developed in Matlab/Simulink to simulate wave energy converters. WEC-Sim has been developed jointly by the National Renewable Energy Laboratory (NREL) and Sandia National Laboratories (SNL) since its initial release in 2014. WEC-Sim simulations are performed in the time domain based on the radiation and diffraction method using hydrodynamics coefficients derived from boundary element method (BEM)-based frequency-domain potential flow solvers (e.g., WAMIT, NEMOH, Capytaine, or ANSYS-AQWA). Within this level of modeling fidelity, WEC-Sim can handle floating body hydrodynamics, mechanical and electrical power generation methods, advanced control implementation, mooring systems, and other unique applications such as desalination. WEC-Sim functionalities are developed using Simulink blocks and Matlab functions. WEC-Sim is capabilities include simulation of different wave conditions, constraints and PTOs, body dynamics, mooring systems, among other advanced features such as nonlinear hydrodynamics, nonlinear PTOs, body-to-body interactions, etc.

hydrodynamics modeling↗

Analyzing impact of $\mathrm{DER}$ on $\mathrm{FIDVR}$ - comparison of $\mathrm{EMT}$ simulation of a combined transmission and distribution grid with aggregated positive sequence models

The increase in percentage of distributed energy resources (DERs) brings in a degree of uncertainty in bulk power system planning and operations. Further, the presence of 1 - φ induction motors introduces the possibility of motor stalling and fault induced delayed voltage recovery (FIDVR). With newer versions of IEEE Std 1547™ there can be the opportunity to obtain dynamic voltage support from DERs. In this report, the impact of DERs providing dynamic voltage on the dynamic behavior of 1 - φ induction motors is examined in detail along with an exploration of the need for simulation platforms that go beyond positive sequence. The studies discussed here are carried out both in detailed electromagnetic time domain and in positive sequence domain for comparison.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Transmission-and-Distribution Dynamic Co-simulation Framework for Distributed Energy Resource Frequency Response

The rapid deployment of distributed energy resources (DERs) in distribution networks has made it challenging to balance the transmission system and stabilize frequency. DERs have the ability to provide frequency regulation services; however, existing frequency dynamic simulation tools - which were developed mainly for the transmission system - lack the capability to simulate distribution network dynamics with high penetrations of DERs. Although electromagnetic transient simulation tools can simulate distribution network dynamics, the computation efficiency limits their use for large-scale transmission-and-distribution (T&D) co-simulation. This paper presents an efficient open-source T&D dynamic co-simulation framework for DER frequency response based on the HELICS platform and off-the-shelf T&D simulators. The challenge of synchronizing the simulation time between the transmission network and the DERs in the distribution network is solved through the detailed modeling of DERs in frequency dynamic models while DER power flow models are also preserved in the distribution networks, thereby respecting local voltage constraints when dispatching DER power for frequency response. DER frequency response (primary and secondary) is simulated in case studies to validate the proposed framework. Last, the accuracy of the proposed co-simulation model is benchmarked, and a large T&D system simulation (2k transmission and 1M distribution nodes) is presented to demonstrate the efficiency and effectiveness of the overall framework.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A graph embedding‐based approach for automatic cyber‐physical power system risk assessment to prevent and mitigate threats at scale

Abstract Power systems are facing an increasing number of cyber incidents, potentially leading to damaging consequences to both physical and cyber aspects. However, the development of analytical methods for the study of large‐scale power infrastructures as cyber‐physical systems is still in its early stages. Drawing inspiration from machine‐learning techniques, the authors introduce a method inspired by the principles of graph embedding that is tailored for quantitative risk assessment and the exploration of possible mitigation strategies of large‐scale cyber‐physical power systems. The primary advantage of the graph embedding approach lies in its ability to generate numerous random walks on a graph, simulating potential access paths. Meanwhile, it enables capturing high‐dimensional structures in low‐dimensional spaces, facilitating advanced machine‐learning applications, and ensuring scalability and adaptability for comprehensive network analysis. By employing this graph embedding‐based approach, the authors present a structured and methodical framework for risk assessment in cyber‐physical systems. The proposed graph embedding‐based risk analysis framework aims to provide a more insightful perspective on cyber‐physical risk assessment and situation awareness for power systems. To validate and demonstrate its applicability, the method has been tested on two cyber‐physical power system models: the Western System Coordinating Council (WSCC) 9‐Bus System and the Illinois 200‐Bus System , thereby showing its advantages in enhancing the accuracy of risk analysis and comprehensiveness of situational awareness.

Sun, Shining↗

Modeling of Inductive Constant Power Load for Electromagnetic-Transient Simulations-Part II

This paper improves the dynamic constant power (CP) load model that was published in Part I, which is appropriate for electromagnetic-transient (EMT). The improved model conserves all features of its predecessor. For instance, it maintains a fixed power consumption (both active and reactive parts) and a fixed power factor for loads that are predominantly inductive. Furthermore, as the proposed model is a time-dependent system, it is applicable to both sinusoidal and non-sinusoidal case studies. However, the previous model cannot be easily integrated with numeric solvers because it simulated load data over one cycle all together, not sequentially in a time-step manner, due to the limitation involved with the power factor. The improved version, on the contrary, allows the load to be simulated at every time step, which would facilitate its integration with numeric solvers. The model's validity is confirmed by comparing its response with data that is synthesized from constant impedance load, and the result is satisfactory.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Mitigation of Motor Stalling and FIDVR via Energy Storage Systems with Temporal Logic Specifications

The fault-induced delayed voltage recovery (FIDVR) phenomenon has been very common from the distribution system through the transmission system. It causes a delay on recovering significantly depressed local voltage after the fault is cleared, and it can also lead to more widespread cascading system failures. Mitigating this event with current control approaches is challenging and becoming a crucial issue. Here, a model predictive control-based strategy employing signal temporal logic specifications is proposed to help mitigate FIDVR. To this end, it investigates and extends a dynamic performance model allowing analytic insights into the system-wide impact of motor stalling and FIDVR. The proposed controller provides richer descriptions of voltage specifications addressing both magnitude and time simultaneously. We consider different control specifications with reactive power support from energy storage systems to prevent the voltage during/after the fault from dropping too low, and reduce the delay time of voltage recovery. The simulation results conducted with the IEEE 57 bus test network validate the proposed method and demonstrate the effectiveness of the mitigation strategy on FIDVR.

25 ENERGY STORAGE↗

Assessment of the Electrical Substation-Grid Testbed with Inside/Outside Devices and Distributed Ledger Technology

The electrical substation-grid testbed was created to integrate the GOOSE and/or DNP (Distributed Network Protocol) messages with time synchronized sources and Distributed Ledger Technology (DLT). The objective was to study the impact of faults and cyber-events at an electrical substation with inside (protective relays) and outside (power meters) substation devices. The electrical substation-grid testbed was based on the design of a 34.5/ 12.47 kV electrical substation (sectionalized bus configuration) with two power transformers, connected to radial power lines and load feeders. The electrical substation-grid testbed was installed at 252 lab space (Advanced Power System Protection), Grid Research Integration and Deployment Center (GRID-C), Oak Ridge National Laboratory. This testbed was created for Task 5, DarkNet project. The electrical substation-grid testbed was created to simulate fault and/or cyber events that could potentially result in damage to the electrical infrastructure. In addition, tests were run that are usually not allowed to be performed in an operational electrical power grid, because these test scenarios could trip breakers and/or generate fault situations that could potentially damage equipment. The number of tests performed in the electrical substation-grid testbed were executed in a better way than in a real electrical substation and/or power grid, because multiple tests could be run in a short period of time, and complex permits, and safety/ schedule restrictions like in a real electrical substation environment were not needed. The electrical substation-grid testbed was created using real measurement, communication, and protection devices that are used by electrical utilities, to have same conditions that we could observe in a real power grid or electrical substation. The electrical substation-grid testbed was based on using a real time simulator and expansion box with amplifiers that were wired to electrical substation-grid devices. This hardware-in-the-loop (HIL) was provided by protective relays, power meters, ethernet switches, remote terminal units, synchronized timing network clock, DLT devices, workstations, and servers. This report includes the design, installation, and assessment of the electrical substation-grid testbed that was similar to an operational electrical substation, integrating the power system protection, communication, and control systems. The results for the electrical substation-grid testbed were based on:• verifying the analog signals for protective relays and power meters, • observing the synchronized time source frame at devices, • authenticating the GOOSE (IEC 61850) and DNP messages from power meters and protective relays, and • verifying the trip conditions of protective relays at fault tests with the power system fault event detection, using DLT devices. For future work, the electrical substation-grid testbed with protective relays and power meters, using DLT and synchronized time source from DarkNet, will be used to study the impact of cyber-events at inside and outside substation devices. Advanced algorithms for detecting cyber-events produced by non-desired protective relay settings will be studied, to improve the detection and reliability of protection, control, and communication systems at power grids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

PV-BESS DC-Series Integration for Regulated DC Systems

DC-series integration introduces a novel approach to seamlessly integrate a solar photovoltaic (PV) array and a battery energy storage (BES) in series. This system, referred to as the PV-integrated battery energy storage system—dc series (PVBESS-DCS), simplifies integration and enhances power density by leveraging the inherent voltage-source characteristics of batteries and adopting the concept of partial power processing. However, addressing voltage variations of a PV array and a BES under different operational conditions remains a challenge to apply the PVBESS-DCS to a regulated dc system, where the dc-bus voltage is fixed. This article proposes a PVBESS-DCS solution tailored for regulated dc systems. Within this framework, we present a controllable series voltage source compensating for the voltage differences between the PV and BES sources and the dc bus. Thus, the system can perform PV maximum power point tracking and curtailment control while charging and discharging BES and connected to a regulated dc bus. Additionally, we present a single-stage multiport partial power processing dc–dc converter designed for the proposed PVBESS-DCS. It utilizes a triple active bridge dc–dc converter topology. Finally, this article presents operating principles, control strategies, simulation results, and experimental findings of the proposed PVBESS-DCS for regulated dc systems.

25 ENERGY STORAGE↗

Validation of Numerical Tools for Calculating Reactivity Feedback in Sodium Fast Reactors Using SEFOR Experimental Data

The Southwest Experimental Fast Oxide Reactor (SEFOR) was an experimental sodium-cooled fast breeder reactor operated from 1969 to 1972 with experiments designed to measure Doppler reactivity feedback in a wide temperature range from around 350 °F to temperatures approaching the melting point of mixed oxide fuel of around 5000 °F, providing valuable data for code validations. Co-supported by the Department of Energy (DOE) Fast Reactor Program (FRP) and the DOE Nuclear Energy Advanced Modeling and Simulation (NEAMS) program, the SEFOR benchmark project focused on using the experimental data to validate numerical tools that are used in industry and academia to design and license sodium-cooled fast reactors (SFRs). By the end of FY-25, substantial progress was achieved in the SEFOR benchmark study. A variety of numerical tools commonly used for modeling SFRs were applied to develop models for SEFOR core configurations I-D, I-E, I-I, and I-J. These included Monte Carlo codes such as MCNP, Serpent, and Shift; deterministic codes such as the legacy Argonne Reactor Computation (ARC) suite and the high-fidelity NEAMS code Griffin; and the system analysis code SAS4A/SASSYS-1 (SAS). Using these models, both SEFOR zero-power experiments and power-ascending tests were successfully simulated. Comparisons were performed against experimental measurements of core criticalities, reflector worth, kinetics parameters (Λ/βeff), isothermal reactivity feedback (from 350 °F to 760 °F at zero power), and power-ascending reactivity feedback (as power increased from 0.4 MW to 17 MW). In general, these comparisons demonstrated very good agreement between numerical results and experimental data. In Fiscal Year 26 (FY-26), the SEFOR benchmark project will continue to address the modeling issues identified in FY-25. Effort will focus on the simulation of reactivity insertion transients in SEFOR core II using the ARC/SAS model. Future work will also focus on incorporating BISON into the SEFOR core modeling process to enable the first Multiphysics simulations of the isothermal tests based on the MOOSE framework.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

An Innovative Energy Management System for Microgrids with Multiple Grid-Forming Inverters

As increasingly more grid-forming (GFM) inverter-based resources replace traditional fossil-fueled synchronous generators as the GFM sources in microgrids, the existing microgrid energy management systems (EMS) need to be updated to control and coordinate multiple GFM inverters that consider system control objectives under different microgrid connection states. For each state, we formulate an optimization problem and apply a real-time feedback-based control algorithm; altogether, the control algorithms seamlessly connect the states into a generic microgrid EMS that controls the nodal voltages and frequencies, becomes a virtual power plant (VPP) when connected to the main grid, and coordinates power sharing responsibility among GFM sources when islanded. We showcase the EMS on a real-world simulation of a microgrid under the different states to demonstrate its operational effectiveness.

energy management systems↗

Does practice make perfect? Lessons learned from full-scale power system incident response exercise

While threats to the energy sector occur daily, few utilities get the opportunity to fully test out their detection and response mechanisms to advanced threats in the real world. With the high demand for reliability, few grid operators would allow execution of simulated cyber-attacks on their live systems. The DOE-funded Liberty Eclipse project offers a unique opportunity for small and large utilities and coops to practice their combined IT/OT responses to a live red team executing attacks against an isolated power system on an island in New York. Both cyber teams and power operations teams must work together to detect and respond to attacks, even restoring the power system against extreme impacts. Lessons learned from these exercises reveal key takeaways for understanding what a real attack against the electric sector will look like, gaps in execution of the best-laid plans when the pressure of a real event is bearing down, and how organizations can better prepare for advanced attacks by optimizing participation in exercises. This presentation will discuss successes and opportunities for improvement both in how utilities can prepare for and respond to events, as well as how full-scale IT/OT exercises can be coordinated.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Fairness-based Distributed Energy Coordination for Voltage Regulation in Distribution Systems

The rapid adoption of photovoltaic (PV) systems combined with falling prices of energy storage is paving the way for a future in which customers could locally supply their energy needs and export surplus power to the grid. However, reverse power flow from multiple sites in a network can cause overvoltage that decreases system reliability and the utilization level of PV system. In this paper, we present a two-stage approach to solve the energy coordination problem in distribution networks. In the first stage, a household with PV and energy storage is optimized to allow customers to adopt different control strategies such as load following and tariff arbitrage. We show that such customer-led control strategies can cause reverse power flows during peak PV generation periods, thus resulting in overvoltage. In such cases, the second stage of the proposed approach is called upon to solve a fairness-based energy coordination problem that can maintain voltages within limits while maximizing the PV generation while fairly distributing the actions among all the PV systems. As a result, each of the resources in the network has equal opportunity to export power and shares the responsibility of voltage regulation. Simulation studies have been carried out on the IEEE 13-bus test feeder to verify the effectiveness of the proposed approach.

Distributed energy resources, fairness, overvoltag↗

PHIL Validation of Ultracapacitor Storage for Black Start Application

A deck of slides that present the modeling, and calibration to conduct PHIL test of ultracapacitor energy storage system. The PHIL test has been done while preparing for the black start field demonstration with Idaho Falls Power. Presentation is invited to the 6th International Workshop on Grid Simulator Testing of Wind Turbine Power Trains and Other Renewable Technologies.

13 HYDRO ENERGY↗

Using a Grid-Forming Inverter to Stabilize a Low-Inertia Power System - Maui Hawaiian Island

As power systems around the world integrate greater amounts of wind and solar photovoltaic power, periods of very high instantaneous power shares of inverters, the primary interfacing technology for these generation sources, are complicating system stability and control. The contemporary, primary mode of inverter operation, grid-following, which explicitly assumes the presence of a local, stable voltage waveform, yields operational inadequacy at high instantaneous power shares potentially leading to instability due to the low-inertia conditions, as well as the correlated reduced voltage forming capacity on the respective system. Parallel connected grid-forming inverters, which directly regulate the local voltage, are a solution that is expected to bolster system stability and mitigate the shortcomings of the grid-following technology. In this paper, grid-following and two types of grid-forming inverter control, the traditional linear droop and the recently introduced nonlinear exponential droop (Droop-e), are simulated on a low-inertia, H = 0.48s, high inverter-based resource scenario, 97%, with a validated electromagentic transient domain model of the Hawaiian island of Maui power system. The benefit of a single grid-forming device over its grid-following counterpart is significant, both in terms frequency deviation and voltage stability. Further, the superiority of the Droop-e and the associated secondary power sharing control over both grid-following and linear droop grid-forming technologies is displayed, with improved nadir and rate of change of frequency over the linear droop control.

droop control↗

Improved melt model for power flow

Accelerators that drive z-pinch experiments transport current densities in excess of 1 MA/cm 2 in order to melt or ionize the target and implode it on axis. These high current densities stress the transmission lines upstream from the target, where rapid electrode heating causes plasma formation, melt, and possibly vaporization. These plasmas negatively impact accelerator efficiency by diverting some portion of the current away from the target, referred to as “current loss”. Simulations that are able to reproduce this behavior may be applied to improving the efficiency of existing accelerators and to designing systems operating at ever higher current densities. The relativistic particle-in-cell code CHICAGO ® is the primary code for modeling power flow on Sandia National Laboratories’ Z accelerator. We report here on new algorithms that incorporate vaporization and melt into the standard power-flow simulation framework. Taking a hybrid approach, the CHICAGO® kinetic/multi-fluid treatment has been expanded to include vaporization while the quasi-neutral equation-of-motion has been updated for melt at high current-densities. For vaporization, a new one-dimensional substrate model provides a more accurate calculation of electrode thermal, mass, and magnetic field diffusion as well as a means of emitting absorbed contaminants and vaporized metal ions. A quasi-fluid model has been implemented expressly to mimic the motion of imploding liners for accurate inductance histories. For melt, a multi-ion Hall-MHD option has been implemented and benchmarked against Alegra MHD. This new model is described with sufficient detail to reproduce these algorithms in any hybrid kinetic code. Physics results from the new code are also presented. A CHICAGO ® Hall-MHD simulation of a radial transmission line demonstrates that Hall physics, not included in Alegra, has no significant impact on the diffusion of electrode material. When surface contaminant desorption is mocked in as a hydrogen surface plasma, both the surface and bulk-material plasmas largely compress under the influence of the j × B force. Similar results are seen in Alegra, which also shows magnetic and material diffusion scaling with peak current. Test vaporization simulations using MagLIF and a power-flow experimental geometry show Fe + ions diffuse only a few hundred µm from the electrodes, so present models of Z power flow remain valid.

43 PARTICLE ACCELERATORS↗

High-Fidelity Analysis of EV Integration on Real Utility Feeders in Colorado

Residential electric vehicle (EV) charging has the potential to alter long-held assumptions on load characteristics impacting distribution grid planning, operations, and design standards. This study identifies analysis and control methods to increase the affordability of residential EV charging both for Xcel Energy and their customers. The project also provides solutions for more reliable grid interconnection that can support a reliable utility business model prepared for increasing EV charging load in the coming years. For this project, we referenced Level 2 alternating current (AC) onboard charging profiles for various vehicle models and high-fidelity charging data collected at the experimental setup established at the EV Research Infrastructure Laboratory at the National Renewable Energy Laboratory (NREL). Next, we developed EV adoption models for 2030 and 2040 for the Boulder and Aurora regions in Colorado. Moreover, we evaluated different smart charging control algorithms and compared their performance. We developed time-of-use (TOU)-based and grid-aware active EV charging control methods and integrated them within the study region to understand field impacts. Diving deeper, we selected 10 feeders in Boulder and Aurora for high-fidelity grid modeling down to the house level. We executed detailed grid analysis comparing the smart charge management (SCM) algorithms we developed. Finally, we created a novel tool, Electric Vehicle Infrastructure--Distribution System Integration Tool (EVI-DiST), to integrate all the approaches in a single software environment to provide easy integration, fast simulation, and detailed evaluation capability for utility engineers and other stakeholders.

33 ADVANCED PROPULSION SYSTEMS↗

Exploring the Feasibility of INCONEL® ALLOY 740H® for Power Plant Headers: Integrating Machine Learning with Computational Fluid Dynamics (CFD)

This keynote presentation explores the behavior of headers—essential components of pipeline systems—using ANSYS simulation software and machine learning techniques. The study aims to predict the thermal and mechanical performance of headers under diverse conditions through both steady-state and transient simulations. We investigate critical parameters such as heat transfer coefficient, fluid velocity, and temperature to optimize header design. Conducted as part of a DOE project led by NCAT in collaboration with UNC Charlotte, this research encompasses multiple key topics. The initial section focuses on the behavior of header systems under steady-state conditions using ANSYS simulation. It underscores the importance of headers in industrial infrastructure, especially in the energy sector, and examines the implications of material selection and flow direction on heat transfer dynamics. Methodologically, we employ Computational Fluid Dynamics (CFD) analysis through ANSYS, detailing the development of models, material properties, geometry specifications, boundary conditions, and meshing strategies. Our simulations explore various operational parameters, including temperature and mass flow rates, crucial for predicting heat transfer coefficients and enhancing header design. Results from the study include parametric investigations into mesh sensitivity, viscosity model evaluations, and the effects of heat transfer locations, all validated against theoretical calculations. We conclude with insights on mesh optimization, the suitability of viscosity models, and recommendations for future research aimed at improving header system efficiency and sustainability in industrial applications.

20 FOSSIL-FUELED POWER PLANTS↗