Supervisory Optimal Control for Photovoltaics Connected to an Electric Power Grid.
Abstract not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Complex oxides such as perovskite cobaltites exhibit rich phenomena at interfaces due to the complex interplay between their structural, defect, electronic, and magnetic degrees of freedom. Here, we study this interplay here in the ferromagnetic metallic cobaltite La 1−𝑥 Sr 𝑥 CoO 3−𝛿 , using specific substrates to vary both the heteroepitaxial strain (compressive vs tensile) and growth orientation ((001) vs (110)). Transmission electron microscopy, electron energy-loss spectroscopy, high-resolution X-ray diffraction, magnetometry, polarized neutron reflectometry, and electronic magnetotransport measurements are applied. Lattice mismatch and growth orientation are found to enable the precise control of interfacial oxygen vacancy ordering in La 1−𝑥 Sr 𝑥 CoO 3−𝛿 , thus dictating strain relaxation and oxygen vacancy depth profiles, in turn controlling thickness-dependent magnetic and electronic properties. In particular, compressive strain and (110) orientations minimize deleterious magnetic/electronic dead layer effects, leading to the optimization of interfacial magnetism and transport. Strain and orientation tuning of oxygen vacancy ordering are thus established as powerful means to control physical properties at cobaltite-based interfaces, relevant to several fields.
Entanglement underpins the power of quantum technologies, yet it is fragile and typically destroyed by dissipation. Paradoxically, the same dissipation, when carefully engineered, can drive a system toward robust entangled steady states. However, this engineering task is nontrivial, as dissipative many-body systems are complex, particularly when they support multiple steady states. Here, we derive analytic expressions that predict how the steady state of a system evolving under a Lindblad equation depends on the initial state, without requiring integration of the dynamics. These results extend Refs. [V. V. Albert and L. Jiang, Phys. Rev. A 89, 022118 (2014); V. V. Albert et al., Phys. Rev. X 6, 041031 (2016)], showing that while the steady-state manifold is determined by the Liouvillian kernel, the weights within it depend on both the Liouvillian and the initial state. We identify a special class of Liouvillians for which the steady state depends only on the initial overlap with the kernel. Our framework provides analytical insight and a computationally efficient tool for predicting steady states in open quantum systems. As an application, we propose schemes to generate metrologically useful entangled steady states in spin ensembles via balanced collective decay.
The conventional generation within the grid is gradually being replaced by inverter based resources. However, the integration of inverters into realistic transmission grid models has not been thoroughly explored. To address this gap, this work develops an automation framework aimed at facilitating the integration of a large number of inverter-based resources into a large-scale grid. Two types of grid-forming controlled inverters—namely droop-controlled inverters and virtual synchronous machine-controlled inverters—are developed for use in positive-sequence simulation packages. Various penetration levels ranging from 23% to 100% of grid-forming inverters are tested in a grid setup in the US Western Interconnection. The dynamic performance of inverters under different control schemes is compared in response to various disturbances.
Nuclear power plants must be, by design and construction, robust structures and difficult to penetrate. Ideally, for security, the reactors would be sited underground, beneath a massive solid block, too thick to be penetrated by tools or explosives with all communications and power transfer lines also underground and fortified. Limiting access with difficult-to-penetrate physical barriers is going to be key for determining response and staffing requirements.
Nuclear power plants must be, by design and construction, robust structures and difficult to penetrate. Limiting access with difficult-to-penetrate physical barriers is going to be key for staffing reduction. Ideally, for security, the reactors would be sited underground, beneath a massive solid block, too thick to be penetrated by tools or explosives with all communications and power transfer lines also underground and fortified. Having the minimal possible number of access points and methods to completely block access from these points if a threat is detected will greatly help us justify staffing reduction.
Abstract not provided.
Abstract not provided.
The project addresses both fundamental and practical challenges of GFM/GFL inverter control for the power grids with high inverter based resources (IBRs) penetration. A data- driven modeling technique is applied to accurately model dynamics of PWM inverters, including electromagnetic-transient (EMT). Systematic and integrative designs of grid- forming (GFM) and grid-following (GFL) primary controls are developed to guarantee system performance under either normal or abnormal operating conditions without violating constraints. This modeling and control framework provides black-start capability in case of an outage without relying on rotating generators, and its secondary control is also shown to enhance resilience against cyber-physical attacks.
Explore the source record for details and available documents.
Abstract not provided.
A control system for a switched reluctance machine includes a capacitor and an inverter connected to the capacitor, wherein the inverter generates current signals and a ripple current returned to the capacitor. A switched reluctance machine (SRM) receives the current signals and generates a position signal. A controller receives the ripple current, current signal values of the current signals, and the position signal and generates desired reference current waveforms received by the inverter to adjust the current signals received by the SRM.
This presentation provides an introductory overview of system dynamics and frequency control in electric power systems, with a focus on concepts relevant to small and interconnected grids such as those in Malawi. It explains foundational principles of AC system frequency, the relationship between generation-demand balance and frequency deviations, and the operational limits of generators and end-use equipment. The deck discusses frequency stability within broader system stability classifications and illustrates how inertia and turbine-governor dynamics shape system response to disturbances. It then outlines the tiered approach to frequency control - primary, secondary, and tertiary - detailing the roles, characteristics, timescales, and response mechanisms of each. Special emphasis is placed on hydro and thermal unit behavior, area control error (ACE), automatic generation control (AGC), and the operational implications of interconnecting small systems with larger grids. The material was developed to support Malawi's electricity sector and the establishment of the Southern Africa Battery Energy Storage Center of Excellence (SABESS CoE).
The Information and Communications Technology (ICT) for control and monitoring of power systems is a layer on top of the physical power system infrastructure. The cyber system and physical power system components form a tightly coupled Cyber–Physical System (CPS). Sources of vulnerabilities arise from the computing and communication systems of the cyber–power grid. Cyber intrusions targeting the power grid are serious threats to the reliability of electricity supply that is critical to society and the economy. In a typical Information Technology environment, numerous attack scenarios have shown how unauthorized users can access and manipulate protected information from a network domain. The need for cyber security has led to industry standards that power grids must meet to ensure that the monitoring, operation, and control functions are not disrupted by cyber intrusions. Cyber security technologies such as encryption and authentication have been deployed on the CPS. Intrusion or anomaly detection and mitigation tools developed for power grids are emerging. Furthermore, this survey paper provides the basic concepts of cyber vulnerabilities of distribution systems and CPS security. The important ICT subjects for distribution systems covered in this paper include Supervisory Control And Data Acquisition, Distributed Energy Resources, including renewable energy and smart meters.
An important strategy to meet California's ambitious energy efficiency goals is to use innovative wireless communications, embedded sensors, data analytics and controls to significantly reduce lighting energy use in commercial buildings. This project developed a suite of networked lighting solutions to further this goal. The technologies include a platform for low-cost sensing, distributed intelligence and communications, the “PermaMote,” which is a self-powered sensor and controller for lighting applications. The project team also developed a task ambient daylighting system that integrates sensors with data-driven daylighting control using an open communication interface, called the “Readings-At-Desk” (RAD) system. To address the problem of building occupants being confused about how to operate traditional lighting control systems, the research team created content that could be the basis for a user interface standard for lighting controls. Finally, to address the difficulty of ensuring that advanced lighting control systems actually deliver their promised energy savings, the project team developed a new method for evaluating and specifying lighting systems’ performance. The research team validated these technologies in the laboratory, showing significant lighting energy savings, up to 73% for the PermaMote sensor system from occupancy control and daylight dimming features, compared to the same light source (LED replacement lamps) operated via simple on/off scheduling. The project team also developed a proposed standard lighting data model and user interface elements, which were contributed to the ANSI Lighting Systems Committee (C137) for standardization. Existing data models are incomplete and inconsistent, whereas the lighting-specific data model developed here is clear and comprehensive, to serve as a starting point for creating common, universally agreed upon semantic definitions of key lighting parameters, to promote interoperability. For the task on verifiable performance of lighting systems, the project team developed a more effective metric for capturing the actual energy impact of a lighting system over time — the energy usage intensity (kWh/ft2/year). Three commercial lighting systems were tested in FLEXLAB® using this new metric, and the tests show a wide range in the accuracy of the self-reported energy-use metric, from 0.5% to 28% error compared to direct measurement of lighting energy using dedicated submeters. Overall, the project team estimates that these advanced technologies can reduce California office lighting energy use by 20% (above and beyond normal advanced lighting controls mandated by Title 24), resulting in about 1,600 GWh/year in savings.
Distribution energy resources (DERs) have been integral components of modern power systems, and their capability to provide grid services has been widely studied. To promote the deployment of these resources in providing grid services in real-world utility operations, this paper proposes a day-ahead scheduler model for a distribution system connected DER plant. A certain amount of generation capacity of this DER plant is reserved for frequency services, and some ancillary services for the distribution system-including peak load reduction, voltage regulation, and power factor control-are integrated into the model. The model is tested on a real-world distribution system. From the simulation results, the energy and reserve schedule of the solar photovoltaic (PV) unit and battery energy storage system (BESS) can be determined, and voltage and power factor are well maintained. Additionally, in order to demonstrate the specific characteristics of the co-located and hybrid operation modes for the PV and BESS, these two modes are analyzed both theoretically and through real-time simulation. Simulation results show that most of PV's variability is transferred to the net power in the co-located mode, whereas it is transferred to the BESS in the hybrid mode. This proposed scheduler model and the comparison of co-located and hybrid modes can provide practical guidance for the applications of DER plant in the real-world utility.
Islanded microgrids integrated with renewable energy resources bring additional challenges to the primary frequency control due to their power-electronic interfaced generations. Developing an efficient control strategy for inertia emulation and frequency response support of microgrids is becoming an important issue. Wind turbine dynamics, however, will degrade the emulated inertial and primary responses with most traditional control strategies. On the other hand, compensation methods often require the knowledge of system models at the design stage and state estimation for feedback once deployed online. To overcome these challenges, this paper explores a model-free control (MFC) strategy to emulate the desired inertia and support the frequency response of a diesel-wind microgrid system. Additionally, the proposed MFC strategy utilizes a model reference concept to obtain guaranteed inertial response and improve the frequency response of microgrids. This work considers different control strategies with different operating points. The proposed controller is implemented and verified using the modified 33-bus full nonlinear model of the three-phase diesel-wind system in Simulink. Simulation results demonstrate the improved frequency response by precisely emulating the desired inertia using the MFC strategy.