Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical detectability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Counting of Hong-Ou-Mandel Bunched Optical Photons Using a Fast Pixel Camera

The uses of a silicon-pixel camera with very good time resolution (∼nanosecond) for detecting multiple, bunched optical photons is explored. We present characteristics of the camera and describe experiments proving its counting capabilities. We use a spontaneous parametric down-conversion source to generate correlated photon pairs, and exploit the Hong-Ou-Mandel (HOM) interference effect in a fiber-coupled beam splitter to bunch the pair onto the same output fiber. It is shown that the time and spatial resolution of the camera enables independent detection of two photons emerging simultaneously from a single spatial mode.

47 OTHER INSTRUMENTATION↗

Intensified Tpx3Cam, a fast data-driven optical camera with nanosecond timing resolution for single photon detection in quantum applications

Here we describe a fast data-driven optical camera, Tpx3Cam, with nanosecond scale timing resolution and 80 Mpixel/sec throughput. After the addition of intensifier, the camera is single photon sensitive with quantum efficiency determined primarily by the intensifier photocathode. The single photon performance of the camera was characterized with results on the gain, timing resolution and afterpulsing reported here. The intensified camera was successfully used for measurements in a variety of applications including quantum applications. As an example of such application, which requires simultaneous detection of multiple photons, we describe registration of photon pairs from the spontaneous parametric down-conversion source in a spectrometer. We measured the photon wavelength and timing with respective precisions of 0.15 nm and 3 ns, and also demonstrated that the two photons are anti-correlated in energy.

79 ASTRONOMY AND ASTROPHYSICS↗

Roadmap for Photonics with 2D Materials

Triggered by advances in atomic-layer exfoliation and growth techniques, along with the identification of a wide range of extraordinary physical properties in self-standing films consisting of one or a few atomic layers, two-dimensional (2D) materials such as graphene, transition metal dichalcogenides (TMDs), and other van der Waals (vdW) crystals now constitute a broad research field expanding in multiple directions through the combination of layer stacking and twisting, nanofabrication, surface-science methods, and integration into nanostructured environments. Photonics encompasses a multidisciplinary subset of those directions, where 2D materials contribute remarkable nonlinearities, long-lived and ultraconfined polaritons, strong excitons, topological and chiral effects, susceptibility to external stimuli, accessibility, robustness, and a completely new range of photonic materials based on layer stacking, gating, and the formation of moiré patterns. These properties are being leveraged to develop applications in electro-optical modulation, light emission and detection, imaging and metasurfaces, integrated optics, sensing, and quantum physics across a broad spectral range extending from the far-infrared to the ultraviolet, as well as enabling hybridization with spin and momentum textures of electronic band structures and magnetic degrees of freedom. The rapid expansion of photonics with 2D materials as a dynamic research arena is yielding breakthroughs, which this Roadmap summarizes while identifying challenges and opportunities for future goals and how to meet them through a wide collection of topical sections prepared by leading practitioners.

2D materials↗

The Hubble PanCET Program: A Metal-rich Atmosphere for the Inflated Hot Jupiter HAT-P-41b

We present a comprehensive analysis of the 0.3–5 μm transit spectrum for the inflated hot Jupiter HAT-P-41b. The planet was observed in transit with Hubble STIS and WFC3 as part of the Hubble Panchromatic Comparative Exoplanet Treasury (PanCET) program, and we combine those data with warm Spitzer transit observations. We extract transit depths from each of the data sets, presenting the STIS transit spectrum (0.29–0.93 μm) for the first time. We retrieve the transit spectrum both with a free-chemistry retrieval suite (AURA) and a complementary chemical equilibrium retrieval suite (PLATON) to constrain the atmospheric properties at the day–night terminator. Both methods provide an excellent fit to the observed spectrum. Both AURA and PLATON retrieve a metal-rich atmosphere for almost all model assumptions (most likely O/H ratio of log{sub 10}Z/Z{sub ⊙}=1.46{sub −0.68}{sup +0.53} and log{sub 10}Z/Z{sub ⊙}=2.33{sub −0.25}{sup +0.23}, respectively); this is driven by a 4.9σ detection of H{sub 2}O as well as evidence of gas absorption in the optical (>2.7σ detection) due to Na, AlO, and/or VO/TiO, though no individual species is strongly detected. Both retrievals determine the transit spectrum to be consistent with a clear atmosphere, with no evidence of haze or high-altitude clouds. Interior modeling constraints on the maximum atmospheric metallicity (log{sub 10}Z/Z{sub ⊙}<1.7) favor the AURA results. The inferred elemental oxygen abundance suggests that HAT-P-41b has one of the most metal-rich atmospheres of any hot Jupiters known to date. Overall, the inferred high metallicity and high inflation make HAT-P-41b an interesting test case for planet formation theories.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Strain and dynamic measurements using fiber optic sensors embedded into graphite/epoxy tubes

Graphite/epoxy tubes were fabricated with embedded optical fibers to evaluate the feasibility of monitoring strains with a fiber optic technique. Resistance strain gauges were attached to the tubes to measure strain at four locations along the tube for comparison with the fiber optic sensors. Both static and dynamic strain measurements were made with excellent agreement between the embedded fiber optic strain sensor and the strain gauges. Strain measurements of 10(exp -7) can be detected with the optical phase locked loop (OPLL) system using optical fiber. Because of their light weight, compatibility with composites, immunity to electromagnetic interference, and based on the static and dynamic results obtained, fiber optic sensors embedded in composites may be useful as the sensing component of smart structures.

Dehart, D. W.↗

A gravitational lens candidate with an unusually red optical counterpart

The properties of the strong radio source MG0414 + 0534 are described. It is found to display many of the properties expected in a gravitational lens system. At radio wavelengths and 0.5-arcsec resolution, MG0414 + 0534 is made up of four compact components whose unusual configuration and relative flux densities are similar to those found in confirmed four-image gravitational lens systems. At optical wavelengths three objects are detected, consistent with there being optical objects at the positions of the radio components, given the lower optical resolution. The radio and optical centroid positions agree within the astrometric errors, and the relative ordering of the fluxes is the same. The colors and radiooptical spectral indices are similar, but there are differences larger than the photometric errors and the measured variability (about 30 percent). Extinction by dust might simultaneously explain the unusually red color and the absence of light from a lens.

Hewitt, J. N.↗

Method and apparatus for detecting flaws and defects in heat seals

Flaws and defects in heat seals formed between sheets of translucent film are identified by optically examining consecutive lateral sections of the seal along the seal length. Each lateral seal section is illuminated and an optical sensor array detects the intensity of light transmitted through the seal section for the purpose of detecting and locating edges in the heat seal. A line profile for each consecutive seal section is derived having an amplitude proportional to the change in light intensity across the seal section. Instances in the derived line profile where the amplitude is greater than a threshold level indicate the detection of a seal edge. The detected edges in each derived line profile are then compared to a preset profile edge standard to identify the existence of a flaw or defect.

Rai, Kula R.↗

The effect of timing errors in optical digital systems

The effects of imperfect timing in direct detection (non-coherent) optical binary systems using both PPM and on-off keying for bit transmission are investigated. Particular emphasis is placed on specification of timing accuracy, and an examination of system degradation when this accuracy is not attained. Bit error probabilities are shown as a function of timing errors, from which average error probabilities can be computed for specific synchronization methods. Of significant importance is the presence of a residual, or irreducible error probability in both systems, due entirely to the timing system, that cannot be overcome by the data channel.

Gagliardi, R.↗

Gamma-ray burst and spectroscopy instrumentation development at the Goddard Space Flight Center

This paper summarizes the activities that are specifically related to the development of instrumentation for gamma-ray astronomy. Three programs are described: (1) the Gamma-Ray Imaging Spectrometer (GRIS), a balloon-borne array of seven germanium detectors for high-resolution spectrographic studies of persistent gamma-ray sources; (2) the Transient Gamma-Ray Spectrometer (TGRS), a single radiatively-cooled germanium detector for the spectrographic study of gamma-ray bursts, and (3) the Rapidly Moving Telescope (RMT), a ground-based optical telescope for the detection and study of short-lived optical transients, particularly those that occur in coincidence with gamma-ray bursts.

Teegarden, B. J.↗

Integrated device with diffractive polarization components for a magneto-optical disk head

The optical components in the detection train of a conventional magneto-optical (MO) disk head include a half-wave plate and a polarization beamsplitter. These polarization components are bulky and require specialized mounting hardware. In order to realize a more compact head, we propose that these elements be replaced by an integrated device composed of cascaded volume and surface-relief gratings. Herein, the proposed system is described in detail for the individual elements, theoretical and prototype element performance are compared, and the operational tolerances of these elements are discussed.

Haggans, Charles W.↗

Hydrogen Detection Strategies to Support H2@SCALE - The NREL Sensor Laboratory

Hydrogen represents a major pathway to decarbonize and stabilize the national and international energy industry and select manufacturing markets. To facilitate the development of hydrogen markets, the US Department of Energy initiated H2@Scale to bring together stakeholders to advance affordable hydrogen production, transport, storage, and utilization to increase revenue opportunities in multiple energy sectors. One major impediment to hydrogen implementation is cost. To expedite the use of hydrogen in energy and other markets, the United States announced in 2021 the Hydrogen Shot, which seeks to reduce the cost of clean hydrogen by 80% to $1 per 1 kilogram in 1 decade ("1 1 1"). As the cost of hydrogen drops, new applications will emerge that will require unique configurations of existing equipment and infrastructure, and eventually lead to advances in the generation and utilization of hydrogen. As the hydrogen economy expands, sensors and detection methods will need to adapt to changing infrastructure demands to address the primary targets of health & safety, emissions monitoring, and process control. The NREL Sensor Laboratory is playing a pivotal role in advancing the use of hydrogen sensors and detection methodologies in each of these categories to support DOE's mission for safe and efficient utilization in emerging markets. Health & safety monitors are required to ensure that operators and facilities can react to unintended hydrogen releases, either as GH2, LH2, or as a constituent of blends (e.g., natural gas or ammonia). Current detection methodologies focus on safety applications to detect near its lower flammable limit (4 vol %), and typically include point sensors in applications such as fixed or mobile detectors (e.g., personal gas monitors). Methodologies amenable for area detection include acoustic, emerging optical imaging methods, and flame detectors. Comparable detection strategies can be utilized for emissions monitoring and quantization, however few methods can simultaneously cover both low (emissions) and high (health & safety) levels. Deployment of emission level detectors will be required to 1) reduce product loss through small but potentially significant leaks from an environmental or cost perspective, 2) reduce downtime of high demand systems by early identification of eminent system failures (leaks through pump or compressor seals indicative of impending failure), and 3) address potential emission monitoring requirements that may be set by regulating bodies. The first two points should be adopted by industry to reduce the cost-of-goods-sold. The third main category for hydrogen detection relates to process control and may be advantageous for many existing applications. Two main applications are emerging. For example, the purity requirements for hydrogen that is dispensed from refueling systems for hydrogen fuel cell electric vehicles (FCEV) is rigorously regulated by the Standard SAE J2719, which prescribes maximum allowable levels of multiple impurities in the hydrogen fuel and must be verified by a regulatory body. Hydrogen contaminant detectors (HCD) integrated to the fueling station can assure this compliance. HCDs must be able operate in 100% H2 backgrounds and be able to distinguish between multiple contaminants at low ppm to low ppb levels. Secondly, as a strategy to decarbonize the natural gas grid, there are proposals to blend hydrogen with natural gas. This blending will affect transport applications (pipeline infrastructure), stationary combustion systems (turbines), and consumer and commercial appliances. In the short-term, hydrogen levels up to 20% are proposed. Variations in the hydrogen level can have dramatic impact on the combustion process and on the potential response of safety sensors. These mixtures may be regulated so that the concentration at a delivery point must be monitored with high precision. However, routine maintenance may introduce background gases such as ambient air (with water) or maintenance gases (introduced with welding processes or adhesive outgassing.) Therefore, the detection methodology must be robust enough to recover or respond to various contaminants. Several reviews can be found in literature addressing sensing and detection technologies, including their limitations and applications. However, for most applications, limitations can be alleviated by combining various detection techniques either through system integration or implementation of machine learning methods (artificial intelligence). In this presentation, we will discuss several applications, highlight their current approach for hydrogen detection, and suggest detection strategies to supplement their limitations.

ENERGY STORAGE,HYDROGEN↗

Space Shuttle main engine OPAD: The search for a hardware enhanced plume

The process of applying spectroscopy to the Space Shuttle Main Engine (SSME) for plume diagnostics, as it exists today, originated at Marshall Space Flight Center in Huntsville, Alabama, and its implementation was assured largely through the efforts of Sverdrup AEDC, in Tullahoma, Tennessee. This team continues to lead and guide efforts in the plume diagnostics arena. The process, Optical Plume Anomaly Detection (OPAD), formed the basis for various activities in the development of ground-based systems as well as the development of in-flight plume spectroscopy. OPAD currently provides and will continue to provide valuable information relative to future systems definitions, instrumentation development, code validation, and data diagnostic processing. OPAD is based on the detection of anomalous atomic and molecular species in the SSME plume using two complete, stand-alone optical spectrometers. To-date OPAD has acquired data on 44 test firings of the SSME at the Technology Test Bed (TTB) at MSFC. The purpose of this paper will be to provide an introduction to the OPAD system by discussing the process of obtaining data as well as the methods of examining and interpreting the data. It will encompass such issues as selection of instrumentation correlation of data to nominal engine operation, investigation of SSME component erosion via OPAD spectral data, necessity and benefits of plume seeding, application of artificial intelligence (AI) techniques to data analysis, and the present status of efforts to quantify specie erosion utilizing standard plume and chemistry codes as well as radiative models currently under development.

Powers, W. T.↗

Three-Dimensional High-Resolution Optical/X-Ray Stereoscopic Tracking Velocimetry

Measurement of three-dimensional (3-D) three-component velocity fields is of great importance in a variety of research and industrial applications for understanding materials processing, fluid physics, and strain/displacement measurements. The 3-D experiments in these fields most likely inhibit the use of conventional techniques, which are based only on planar and optically-transparent-field observation. Here, we briefly review the current status of 3-D diagnostics for motion/velocity detection, for both optical and x-ray systems. As an initial step for providing 3-D capabilities, we nave developed stereoscopic tracking velocimetry (STV) to measure 3-D flow/deformation through optical observation. The STV is advantageous in system simplicity, for continually observing 3- D phenomena in near real-time. In an effort to enhance the data processing through automation and to avoid the confusion in tracking numerous markers or particles, artificial neural networks are employed to incorporate human intelligence. Our initial optical investigations have proven the STV to be a very viable candidate for reliably measuring 3-D flow motions. With previous activities are focused on improving the processing efficiency, overall accuracy, and automation based on the optical system, the current efforts is directed to the concurrent expansion to the x-ray system for broader experimental applications.

Cha, Soyoung S.↗

Three-Dimensional High-Resolution Optical/X-Ray Stereoscopic Tracking Velocimetry

Measurement of three-dimensional (3-D) three-component velocity fields is of great importance in a variety of research and industrial applications for understanding materials processing, fluid physics, and strain/displacement measurements. The 3-D experiments in these fields most likely inhibit the use of conventional techniques, which are based only on planar and optically-transparent-field observation. Here, we briefly review the current status of 3-D diagnostics for motion/velocity detection, for both optical and x-ray systems. As an initial step for providing 3-D capabilities, we have developed stereoscopic tracking velocimetry (STV) to measure 3-D flow/deformation through optical observation. The STV is advantageous in system simplicity, for continually observing 3-D phenomena in near real-time. In an effort to enhance the data processing through automation and to avoid the confusion in tracking numerous markers or particles, artificial neural networks are employed to incorporate human intelligence. Our initial optical investigations have proven the STV to be a very viable candidate for reliably measuring 3-D flow motions. With previous activities focused on improving the processing efficiency, overall accuracy, and automation based on the optical system, the current efforts is directed to the concurrent expansion to the x-ray system for broader experimental applications.

Cha, Soyoung S.↗

Caltech–NRAO Stripe 82 Survey (CNSS). III. The First Radio-discovered Tidal Disruption Event, CNSS J0019+00

We present the discovery of a nuclear transient with the Caltech–NRAO Stripe 82 Survey (CNSS), a dedicated radio transient survey carried out with the Karl G.Jansky Very Large Array (VLA). This transient, CNSS J001947.3+003527, exhibited a turn-on over a timescale of <~1 yr, increasing in flux density at 3 GHz from <0.14 mJy in 2014 February to 4.4 ± 0.1 mJy in 2015 March, reaching a peak luminosity of 5 x 10^28 erg s-1 Hz-1 around 2015 October. The association of CNSS J0019+00 with the nucleus (Gaia and our very-long baseline interferometry positions are consistent to within 1 pc) of a nearby S0 Seyfert galaxy at 77 Mpc, together with the radio spectral evolution, implies that this transient is most likely a tidal disruption event (TDE). Our equipartition analysis indicates the presence of a ∼15,000 km s−1 outflow, having energy ∼1049 erg. We derive the radial density profile for the circumnuclear material in the host galaxy to be proportional to R−2.5. All of these properties suggest resemblance with radio-detected thermal TDEs like ASASSN-14li and XMMSL1 J0740-85. No significant X-ray or optical emission is detected from CNSS J0019+00, although this may simply be due to the thermal emission being weak during our late-time follow-up observations. From the CNSS survey we have obtained the first unbiased measurement of the rate of radio TDEs, R(>500μJy) of about 2 × 10−3 deg−2, or equivalently a volumetric rate of about 10 Gpc−3 yr−1. This rate implies that all-sky radio surveys such as the VLA Sky Survey and those planned with ASKAP, will find many tens of radio TDEs over the next few years.

M M Anderson↗

Integrated Miniature Arrays of Optical Biomolecule Detectors

Integrated miniature planar arrays of optical sensors for detecting specific biochemicals in extremely small quantities have been proposed. An array of this type would have an area of about 1 cm2. Each element of the array would include an optical microresonator that would have a high value of the resonance quality factor (Q . 107). The surface of each microresonator would be derivatized to make it bind molecules of a species of interest, and such binding would introduce a measurable change in the optical properties of the microresonator. Because each microresonator could be derivatized for detection of a specific biochemical different from those of the other microresonators, it would be possible to detect multiple specific biochemicals by simultaneous or sequential interrogation of all the elements in the array. Moreover, the derivatization would make it unnecessary to prepare samples by chemical tagging. Such interrogation would be effected by means of a grid of row and column polymer-based optical waveguides that would be integral parts of a chip on which the array would be fabricated. The row and column polymer-based optical waveguides would intersect at the elements of the array (see figure). At each intersection, the row and column waveguides would be optically coupled to one of the microresonators. The polymer-based waveguides would be connected via optical fibers to external light sources and photodetectors. One set of waveguides and fibers (e.g., the row waveguides and fibers) would couple light from the sources to the resonators; the other set of waveguides and fibers (e.g., the column waveguides and fibers) would couple light from the microresonators to the photodetectors. Each microresonator could be addressed individually by row and column for measurement of its optical transmission. Optionally, the chip could be fabricated so that each microresonator would lie inside a microwell, into which a microscopic liquid sample could be dispensed.

Iltchenko, Vladimir↗

A Joint Search for the Electromagnetic Counterpart to the Gravitational-Wave Binary Black-Hole Merger Candidate S250328ae with the Dark Energy Camera and the Prime Focus Spectrograph

The first detection of an optical counterpart to a gravitational wave signal revealed that collaborative efforts between instruments with different specializations provide a unique opportunity to acquire impactful multi-messenger data. We present results of such a joint search with the Dark Energy Camera (DECam) and Prime Focus Spectrograph (PFS) for the optical counterpart of the LIGO-Virgo-KAGRA event S250328ae, a binary black hole merger candidate of high significance detected at a distance of 511$\pm$82 Mpc and localized within an area of 3 (15) square degrees at 50% (90%) confidence. We observed the 90% confidence area with DECam and identified 36 high-confidence transient candidates after image processing, candidate selection, and candidate vetting. We observed with PFS to obtain optical spectra of DECam candidates, Swift-XRT candidates, and potential host galaxies of S250328ae. In total, 3897 targets were observed by seven pointings covering ~50% of the 90% confidence area. After template fitting and visual inspection, we identified 12 SNe, 159 QSOs, 2975 galaxies, and 131 stars. With the joint observations of DECam and PFS, we found variability in 12 SNe, 139 QSOs, 37 galaxies, and 2 stars. We do not identify any confident optical counterparts, though the association is not ruled out for three variable candidates that are not observed by PFS and 6 QSO candidates without clear variability if the optical counterpart of S250328ae is faint. Despite the lack of confident optical counterparts, this paper serves as a framework for future collaborations between wide-field imagers and multi-object spectrographs to maximize multi-messenger analyses.

Zhang, Haibin [Natl. Astron. Observ. of Japan] (OR↗

The active CGCG 077-102 NED02 galaxy within the Abell 2063 galaxy cluster

Context.Within the framework of investigating the link between the central super massive black holes in the cores of galaxies and the galaxies themselves, we detected a variable X-ray source in the center of CGCG 077-102 NED02, which is a member of the CGCG 077-102 galaxy pair within the Abell 2063 cluster of galaxies. Aims.Our goal is to combine X-ray and optical data to demonstrate that this object harbors an active super massive black hole in its core, and to relate this to the dynamical status of the galaxy pair within the Abell 2063 cluster. Methods.We usedChandraandXMM-Newtonarchival data to derive the X-ray spectral shape and variability. We also obtained optical spectroscopy to detect the expected emission lines that are typically found in active galactic nuclei. Finally, we used public ZTF imaging data to investigate the optical variability. Results.There is no evidence of multiple X-ray sources or extended components within CGCG 077-102 NED02. Single X-ray spectral models fit the source well. We detect significant, nonrandom inter-observation 0.5–10 keV X-ray flux variabilities, for observations separated by ∼4 days for short-term variations and by up to ∼700 days for long-term variations. Optical spectroscopy points toward a passive galaxy for CGCG 077-102 NED01 and a Seyfert for CGCG 077-102 NED02. The classification of CGCG 077-102 NED02 is also consistent with its X-ray luminosity of over 10 42 erg s −1 . We do not detect short-term variability in the optical ZTF light curves. However, we find a significant long-term stochastic variability in theg-band that can be well described by the damped random walk model with a best-fit characteristic damping timescale ofτ DRW = 30 −12 +28 days. Finally, the CGCG 077-102 galaxy pair is deeply embedded within the Abell 2063 potential, with a long enough history within this massive structure to have been affected by the influence of this cluster for a long time. Conclusions.Our observations point toward a moderately massive black hole in the center of CGCG 077-102 NED02 of ∼10 6 M ⊙ . As compared to another similar pair in the literature, CGCG 077-102 NED02 is not heavily obscured, perhaps because of the surrounding intracluster medium ram-pressure stripping.

Astronomy & Astrophysics↗