Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “nuclear physics detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

LOITA: Lunar Optical/Infrared Telescope Array

LOITA (Lunar Optical/Infrared Telescope Array) is a lunar-based interferometer composed of 18 alt-azimuth telescopes arranged in a circular geometry. This geometry results in excellent uv coverage and allows baselines up to 5 km long. The angular resolution will be 25 micro-arcsec at 500 nm and the main spectral range of the array will be 200 to 1100 nm. For infrared planet detection, the spectral range may be extended to nearly 10 mu m. The telescope mirrors have a Cassegrain configuration using a 1.75 m diameter primary mirror and a 0.24 m diameter secondary mirror. A three-stage (coarse, intermediate, and fine) optical delay system, controlled by laser metrology, is used to equalize path lengths from different telescopes to within a few wavelengths. All instruments and the fine delay system are located within the instrument room. Upon exiting the fine delay system, all beams enter the beam combiner and are then directed to the various scientific instruments and detectors. The array instrumentation will consist of CCD detectors optimized for both the visible and infrared as well as specially designed cameras and spectrographs. For direct planet detection, a beam combiner employing achromatic nulling interferometry will be used to reduce star light (by several orders of magnitude) while passing the planet light. A single telescope will be capable of autonomous operation. This telescope will be equipped with four instruments: wide field and planetary camera, faint object camera, high resolution spectrograph, and faint object spectrograph. These instruments will be housed beneath the telescope. The array pointing and control system is designed to meet the fine pointing requirement of one micro-arcsec stability and to allow precise tracking of celestial objects for up to 12 days. During the lunar night, the optics and the detectors will be passively cooled to 70-80 K temperature. To maintain a continuous communication with the earth a relay satellite placed at the L4 libration point will be used in conjunction with the Advanced Tracking and Data Relay Satellite System (ATDRSS). Electrical power of about 10 kW will be supplied by a nuclear reactor based on the SP-100 technology. LOITA will be constructed in three phases of six telescopes each. The total mass of the first operational phase is estimated at 58,820 kg. The cost of the fully operational first phase of the observatory is estimated at $8.9 billion. LOITA's primary objectives will be to detect and characterize planets around nearby stars (up to ten parsec away), study physics of collapsed stellar objects, solar/stellar surface features and the processes in nuclear regions of galaxies and quasars. An interferometric array such as LOITA will be capable of achieving resolutions three orders of magnitude greater than Hubble's design goal. LOITA will also be able to maintain higher signal to noise ratios than are currently attainable due to long observation times available on the moon.

Source record↗

Fast sweeping reflectometry upgrade on Tore Supra

In order to study the temporal dynamics of turbulence, the sweep time of our reflectometry has been shortened from 20 to 2 {mu}s with 1 {mu}s dead time. Detailed technical aspects of the upgrade are given, namely, about the stability of the ramp generation, the detection setup, and the fast acquisition module. A review of studies (velocity measurement of the turbulence, modifications of the wavenumber spectrum, radial mapping of correlation time, etc.) offered by such improvements is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for Low-Mass Dark Matter wtih SuperCDMS Soudan and Study of Shorted Electric Field Configurations in CDMS Detectors

The area of dark matter is one of the most interesting and exciting topics in physics today. Existing at the intersection of particle physics and astrophysics, the existence of a new dark matter particle can be used to explain many astrophysical and cosmological observations, as well as to reconcile outstanding issues in the standard model of particle physics. Experiments such as SuperCDMS are built to detect dark matter in the lab by looking for low-energy nuclear recoils produced by collisions between dark matter particles and atoms in terrestrial detectors. SuperCDMS Soudan is particularly well-suited to follow up on possible hints of low-mass dark matter seen by other recent experiments because of its low thresholds and excellent background discrimination. Analyzing SuperCDMS Soudan data to look for low-mass dark matter comes with particular challenges because of the low signal-to-noise very near threshold. However, with a detailed background model developed by scaling high-energy events down into the low-energy signal region, SuperCDMS Soudan produced worldleading limits on the existence of low-mass dark matter. In addition, a few SuperCDMS Soudan detectors experienced cold hardware problems that can affect the data collected. Of particular interest is one detector considered for the low-mass WIMP search that has one of its charge electrodes shorted to chassis ground. Three events were observed in this detector upon unblinding the SuperCDMS Soudan low-energy data, even though <1 event was expected based on pre-unblinding calulations. However, the data collected by the shorted detector may have been compromised since an electrode shorted to ground will modify the electric field in the detector. The SuperCDMS Detector Monte Carlo (DMC) provides an excellent way to model the effects of the modified electric field, so a new model of the expected backgrounds in the low-mass WIMP search is developed using the DMC to try to explain how the short may have affected the data collected. This thesis is organized as follows: Chapter 1 gives a broad introduction to dark matter, discussing the astrophysical and cosmological evidence for its existence, listing several possible particle physics candidates, and outlining several experimental strategies to look for dark matter. Chapter 2 is an overview of CDMS detector technology and the experimental setup at the Soudan Underground Laboratory, with a focus on how data coming out of Soudan is analyzed. Chapter 3 presents results from a search for low-mass dark matter at SuperCDMS Soudan and discusses the interpretation of the results. Chapter 4 contains follow-up work that uses the CDMS Detector Monte Carlo (DMC) to understand the possible systematics associated with a detector that had one of its charge electrodes shorted to ground. This chapter represents the first time the DMC has been used to inform ongoing CDMS analysis. Chapter 5 takes a brief detour into the world of effective field theory (EFT), examining the consequences of an expanded set of possible WIMP-nucleon interactions in the EFT framework. Finally, Chapter 6 wraps up the material of the previous chapters and discusses how the research presented in this thesis can be applied as CDMS moves toward SuperCDMS SNOLAB.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Differential spectral responsivity measurement of photovoltaic detectors with a light-emitting-diode-based integrating sphere source

We present an experimental realization of differential spectral responsivity measurement by using a light-emitting diode (LED)-based integrating sphere source. The spectral irradiance responsivity is measured by a Lambertian-like radiation field with a diameter of 40mm at the peak wavelengths of the 35 selectable LEDs covering a range from 280 to 1550nm. The systematic errors and uncertainties due to lock-in detection, spatial irradiance distribution, and reflection from the test detector are experimentally corrected or considered. In addition, we implemented a numerical procedure to correct the error due to the broad spectral bandwidth of the LEDs. The overall uncertainty of the DSR measurement is evaluated to be 2.2% (k=2) for Si detectors. To demonstrate its application, we present the measurement results of two Si photovoltaic detectors at different bias irradiance levels up to 120mW/cm{sup 2}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dark matter signals at neutrino telescopes in effective theories

We constrain the effective theory of one-body dark matter-nucleon interactions using neutrino telescope observations. We derive exclusion limits on the 28 coupling constants of the theory, exploring interaction operators previously considered in dark matter direct detection only, and using new nuclear response functions recently derived through nuclear structure calculations. We determine for what interactions neutrino telescopes are superior to current direct detection experiments, and show that Hydrogen is not the most important element in the exclusion limit calculation for the majority of the spin-dependent operators.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Chiral effective theory of dark matter direct detection

We present the effective field theory for dark matter interactions with the visible sector that is valid at scales of O(1 GeV). Starting with an effective theory describing the interactions of fermionic and scalar dark matter with quarks, gluons and photons via higher dimension operators that would arise from dimension-five and dimension-six operators above electroweak scale, we perform a nonperturbative matching onto a heavy baryon chiral perturbation theory that describes dark matter interactions with light mesons and nucleons. This is then used to obtain the coefficients of the nuclear response functions using a chiral effective theory description of nuclear forces. Our results consistently keep the leading contributions in chiral counting for each of the initial Wilson coefficients.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Polarized target nuclear magnetic resonance measurements with deep neural networks

Continuous-wave Nuclear Magnetic Resonance (CW-NMR) operated in constant-current mode has served as a foundational technique for polarization measurement in solid-state dynamically polarized targets within nuclear and high-energy physics experiments for several decades, and it remains an essential tool. Conventional Q-meter-based phase-sensitive detection is critical for precise real-time determination of target polarization during scattering runs. However, the accuracy and reliability of these measurements are frequently compromised by elevated noise levels, baseline drift, and systematic uncertainties arising from signal isolation and fitting, ultimately degrading the overall experimental figure of merit. In this work, we report the first successful application of neural network architectures to continuous-wave NMR polarization metrology. By leveraging advanced machine learning techniques for signal extraction and denoising, we achieve a substantial reduction of fitting uncertainties under a variety of realistic simulated and experimental conditions. These improvements translate directly into more robust real-time (online) polarization monitoring and higher precision in subsequent offline analysis. By reducing analysis-induced uncertainty, the resulting methodology can improve the effective figure of merit for scattering experiments employing dynamically polarized targets and provides a new toolset for NMR-based polarimetry in high-energy and nuclear physics.

Metrology↗

Multichannel, time-resolved picosecond laser ultrasound imaging and spectroscopy with custom complementary metal-oxide-semiconductor detector

This paper presents a multichannel, time-resolved picosecond laser ultrasound system that uses a custom complementary metal-oxide-semiconductor linear array detector. This novel sensor allows parallel phase-sensitive detection of very low contrast modulated signals with performance in each channel comparable to that of a discrete photodiode and a lock-in amplifier. Application of the instrument is demonstrated by parallelizing spatial measurements to produce two-dimensional thickness maps on a layered sample, and spectroscopic parallelization is demonstrated by presenting the measured Brillouin oscillations from a gallium arsenide wafer. This paper demonstrates the significant advantages of our approach to pump probe systems, especially picosecond ultrasonics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

RADRELAY RADIOLOGICAL DATA LINK DEVICE

The RadRelay effort developed small, field appropriate, portable prototype devices that allow radiological spectra to be downloaded from field radiological detectors, like the identiFINDER-U, and transmitted to land based experts. This communications capability was designed for the U. S. Coast Guard (USCG) but is also applicable to the Customs and Border Protection (CBP) personnel working in remote locations. USCG Level II personnel currently use the identiFINDER-U Hand-Held Radioisotope ID Devices (HHRIID) to detect radiological materials during specific boarding operations. These devices will detect not only radiological emissions but will also evaluate those emissions against a table of known radiological spectra. The RadRelay has been developed to significantly improve the functionality of HHRIID, by providing the capability to download radiological spectra and then transmit them using satellite or cell phone technology. This remote wireless data transfer reduces the current lengthy delay often encountered between the shipboard detection of unknown radiological material and the evaluation of that data by technical and command personnel. That delay is reduced from hours to minutes and allows the field located personnel to remain on station during the inspection and evaluation process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Highly Selective Recognition of Cd{sup 2+} by an Indole Derivative Chemosensor

A novel chemosensor exhibiting highly selective recognition of Cd {sup 2+} over other metal ions with significant fluorescence quenching was designed and synthesized by a click reaction of dialkyne and indole azide precursors. The compound was identified by {sup 1}H NMR, {sup 13}C NMR, MS, and UV-vis spectroscopy. The fluorescence quenching phenomenon was observed with the addition of Cd {sup 2+}. The reaction conditions, including the selectivity, the amount of Cd {sup 2+}, reaction time, and temperature, were optimized in the article. The product exerted highly selective fluorescence change in the presence of Cd {sup 2+} over other metal ions, such as Li{sup +}, Na{sup +}, K{sup +}, Pb{sup 2+}, Ni{sup 2+}, Zn{sup 2+}, Mn{sup 2+}, Hg{sup 2+}, Cr{sup 3+}, Cu{sup 2+}, and Fe{sup 3+}. Under the optimal conditions, a linearly proportional relationship between fluorescence intensity and the concentration of Cd{sup 2+} was revealed in the range from 0 to 7.226 × 10{sup –5} M. The limit of detection was 2.69 μM. The results suggest that the substance synthesized with 2-methylindole is a novel and quick detector for Cd {sup 2+}.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of 6 Li-loaded pulse-shape-discriminating plastic scintillators

Lithium-loaded organic plastic scintillators combine sensitivity to γ rays with the ability to detect both fast and slow neutrons, making them valuable for applications in nuclear security and in basic nuclear and particle physics. The goal of this work is to characterize the neutron response of two custom lithium-loaded organic plastic scintillators developed at Lawrence Livermore National Laboratory. Both are ternary polystyrene-based formulations containing 1.5 wt.% 6 Li salts of isobutyric acid, but they differ in their primary and secondary dye compositions: one uses m-terphenyl as the primary fluor and with Exalite 404 as the wavelength shifter, whereas the other uses 2,5-diphenyloxazole (PPO) and 9,10-diphenyl-anthracene, respectively. The temporal response of the scintillators was measured via time-correlated single photon counting for γ-ray and neutron events. The proton light yield was measured using the double time-of-flight technique from 1.3 to 15 MeV at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory. For the slow neutron response, an AmBe source moderated with polyethylene was used, and the light output from the 6 Li(n,α)t reaction was characterized. Differences in ionization quenching and temporal response were observed between the two materials with the PPO-containing scintillator exhibiting higher ionization quenching. These results provide performance benchmarks that can guide the design and optimization of future lithium-loaded plastic scintillators for use in basic science and applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Unique capabilities of the fusion product separator SOLITAIRE

SOLITAIRE is a powerful tool to study nuclear fusion, having a very large angular acceptance and good rejection of beam particles. This report shows how this device, combined with a high quality ray-tracing code, can give information about both the evaporation residue angular distribution and cross section from a single measurement. Results are shown for {sup 32}S+{sup 89}Y and {sup 58}Ni+{sup 58,60,64}Ni fusion reactions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Efficient spin resolved spectroscopy observation machine at Hiroshima Synchrotron Radiation Center

Highly efficient spin- and angle-resolved photoelectron spectrometer named ESPRESSO (Efficient SPin REsolved SpectroScopy Observation) machine has been developed at the beamline BL-9B in Hiroshima Synchrotron Radiation Center. Combination of high-resolution hemispherical electron analyzer and the high-efficient spin detector based on very low energy electron diffraction by the ferromagnetic target makes the high-energy resolution and angular resolution compatible with spin- and angle-resolved photoemission (SARPES) measurement. 7.5 meV in energy and {+-}0.18 deg. in angular resolution have been achieved with spin resolution. The ESPRESSO machine, combination of quick energy-band dispersion measurement and Fermi surface mapping by two-dimensional electron detector for the spin integrated ARPES and the high-efficient spin analysis by the efficient spin detector realizes the comprehensive investigation of spin electronic structure of materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement and reduction of low-level radon background in the KATRIN experiment

The KArlsruhe TRItium Neutrino (KATRIN) experiment is a next generation, model independent, large scale experiment to determine the mass of the electron anti-neutrino by investigating the kinematics of tritium beta decay with a sensitivity of 200 meV/c{sup 2}. The measurement setup consists of a high luminosity windowless gaseous molecular tritium source (WGTS), a differential and cryogenic pumped electron transport and tritium retention section, a tandem spectrometer section (pre-spectrometer and main spectrometer) for energy analysis, followed by a detector system for counting transmitted beta decay electrons. Measurements performed at the KATRIN pre-spectrometer test setup showed that the decay of radon (Rn) atoms in the volume of the KATRIN spectrometers is a major background source. Rn atoms from low-level radon emanation of materials inside the vacuum region of the KATRIN spectrometers are able to penetrate deep into the magnetic flux tube so that the alpha decay of Rn contributes to the background. Of particular importance are electrons emitted in processes accompanying the Rn alpha decay, such as shake-off, internal conversion of excited levels in the Rn daughter atoms and Auger electrons. Lowenergy electrons (< 100 eV) directly contribute to the background in the signal region. High-energy electrons can be stored magnetically inside the volume of the spectrometer and are able to create thousands of secondary electrons via subsequent ionization processes with residual gas molecules. In order to reduce the Rn induced background different active and passive counter measures were developed and tested. This proceeding will give an overview on Rn sources within the KATRIN spectrometer, describes how Rn decays inside the spectrometer produce background events at the detector and presents different counter measures to reduce the Rn induced background.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development and application of modeling tools for sodium fast reactor inspection

To support the development of in-service inspection methods for the Advanced Sodium Test Reactor for Industrial Demonstration (ASTRID) project led by the French Atomic Energy Commission (CEA), several tools that allow situations specific to Sodium cooled Fast Reactors (SFR) to be modeled have been implemented in the CIVA software and exploited. This paper details specific applications and results obtained. For instance, a new specular reflection model allows the calculation of complex echoes from scattering structures inside the reactor vessel. EMAT transducer simulation models have been implemented to develop new transducers for sodium visualization and imaging. Guided wave analysis tools have been developed to permit defect detection in the vessel shell. Application examples and comparisons with experimental data are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evaluation of two-stage system for neutron measurement aiming at increase in count rate at Japan Atomic Energy Agency-Fusion Neutronics Source

In order to increase the count rate capability of a neutron detection system as a whole, we propose a multi-stage neutron detection system. Experiments to test the effectiveness of this concept were carried out on Fusion Neutronics Source. Comparing four configurations of alignment, it was found that the influence of an anterior stage on a posterior stage was negligible for the pulse height distribution. The two-stage system using 25 mm thickness scintillator was about 1.65 times the count rate capability of a single detector system for d-D neutrons and was about 1.8 times the count rate capability for d-T neutrons. The results suggested that the concept of a multi-stage detection system will work in practice.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements and models of enhanced recombination following inner-shell vacancies in liquid xenon

Electron-capture decays of 125 Xe and 127 Xe , and double-electron-capture decays of 124 Xe , are backgrounds in searches for weakly interacting massive particles (WIMPs) conducted by dual-phase xenon time projection chambers such as LUX-ZEPLIN (LZ). These decays produce signals with more light and less charge than equivalent-energy 𝛽 decays and correspondingly overlap more with WIMP signals. We measure three electron-capture charge yields in LZ: the 1.1 keV M-shell, 5.2 keV L-shell, and 33.2 keV K-shell at drift fields of 193 and 96.5 V/cm. The LL double-electron-capture decay of 124 Xe exhibits even more pronounced shifts in charge and light. We provide a first model of double-electron-capture charge yields using the link between ionization density and electron-ion recombination, and identify a need for more accurate calculations. Finally, we discuss the implications of the reduced charge yield of these decays and other interactions creating inner-shell vacancies for future dark matter searches.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗