Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “navigations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

WE-G-BRD-01: A Data-Driven 4D-MRI Motion Model to Estimate Full Field-Of-View Abdominal Motion From 2D Image Navigators During MR-Linac Treatment

Purpose: To estimate full field-of-view abdominal respiratory motion from fast 2D image navigators using a 4D-MRI based motion model. This will allow for radiation dose accumulation mapping during MR-Linac treatment. Methods: Experiments were conducted on a Philips Ingenia 1.5T MRI. First, a retrospectively ordered 4D-MRI was constructed using 3D transient-bSSFP with radial in-plane sampling. Motion fields were calculated through 3D non-rigid registration. From these motion fields a PCA-based abdominal motion model was constructed and used to warp a 3D reference volume to fast 2D cine-MR image navigators that can be used for real-time tracking. To test this procedure, a time-series consisting of two interleaved orthogonal slices (sagittal and coronal), positioned on the pancreas or kidneys, were acquired for 1m38s (dynamic scan-time=0.196ms), during normal, shallow, or deep breathing. The coronal slices were used to update the optimal weights for the first two PCA components, in order to warp the 3D reference image and construct a dynamic 4D-MRI time-series. The interleaved sagittal slices served as an independent measure to test the model’s accuracy and fit. Spatial maps of the root-mean-squared error (RMSE) and histograms of the motion differences within the pancreas and kidneys were used to evaluate the method. Results: Cranio-caudal motion was accurately calculated within the pancreas using the model for normal and shallow breathing with an RMSE of 1.6mm and 1.5mm and a histogram median and standard deviation below 0.2 and 1.7mm, respectively. For deep-breathing an underestimation of the inhale amplitude was observed (RMSE=4.1mm). Respiratory-induced antero-posterior and lateral motion were correctly mapped (RMSE=0.6/0.5mm). Kidney motion demonstrated good motion estimation with RMSE-values of 0.95 and 2.4mm for the right and left kidney, respectively. Conclusion: We have demonstrated a method that can calculate dynamic 3D abdominal motion in a large volume, while acquiring real-time cine-MR images for MR-guided radiotherapy.

60 APPLIED LIFE SCIENCES↗

Navigation and Meteorological Data from Multiple Sensors on Airborne Platform (NAVMET-AIR) Value-Added Product Report

The Navigation and Meteorological Data from Multiple Sensors on Airborne Platform (NAVMET-AIR) value-added product encompasses the aafnaviwg data set in the ARM Data Center (ADC), known as the IWG file, named for the Inter-Agency Working Group for Airborne Data and Telemetry Systems (IWGADTS). Its purpose is to produce a suite of tools to promote standardization of instrument interface, data format, and data processing. This data set’s contents are navigational and meteorological state variables at 1 Hz. It also contains higher-order data flags created by ARM Aerial Facility (AAF) scientists to aid analysis such as periods when the aircraft is flying level, operating in maneuvers, or flying through cloud. Due to the nature of research flights, the payload of the aircraft consists of many duplicate and overlapping instruments to ensure, in case of instrument failure, there is a backup to record the data. Measurements from multiple instruments are consolidated into a single file. Each variable of this data set is carefully chosen from the onboard instrumentation and quality checked by AAF scientists to create this wholistic and most accurate data set for airborne research. This document is intended to be a hub towards the individual “read me” files produced for each campaign. For reference about what instrument was used for calculations on specific days, the read me files are located in the ARM IOP archive at the addresses listed, or access the IOP (intensive operational period) database at https://www.archive.arm.gov/.

54 ENVIRONMENTAL SCIENCES↗

Earth-Centered, Earth-Fixed Inertial Navigation System & Error-State Kalman Filter Reference Manual

This is a self-contained reference document that derives the equations necessary to build a combined inertial navigation system and error-state Kalman filter. Coordinate transform, linear time invariant system, inertial sensing, and error-state Kalman filtering theory is built up from first principles. This theory is then leveraged to derive the system equations for two combined inertial navigation system and error-state Kalman filters: (1) a 15-state system modeling white-noise-integrating accelerometer and gyroscope biases, and (2) a 39-state system modeling static and first-order Gauss-Markov accelerometer and gyroscope biases, scale factor errors, and cross-axis sensitivity errors.

42 ENGINEERING↗

ARM Navigation Best Estimate 10 Hz (NAVBE) and 1-min (NAVBE1M) Value Added Products (VAP) for Ship Deployments

The Navigation Best Estimate (NAVBE) VAP was developed in response to the 2012-2013 Marine ARM GPCI Investigation of Clouds (MAGIC) deployment, the first ship-based deployment of the second ARM Mobile Facility (AMF2). It has since been applied to the 2015 ARM Cloud Aerosol Precipitation EXperiment (ACAPEX) deployment. A number of different instruments on the ships collected Global Positioning System (GPS) and Inertial Navigation System (INS) measurements during the MAGIC campaign. The motivation of the NAVBE VAP is to consolidate many different sources of this information in a single, continuous datastream to be used when information is required about ship location and orientation and to provide a more complete estimate than would be available from any one instrument. The result is 10 Hz and 1-min data streams reporting ship position and attitude

54 ENVIRONMENTAL SCIENCES↗

Space navigation.

Deep space navigation and guidance technology, emphasizing simplification of onboard navigation procedures

Mcdonald, W. T.↗

VHF navigation experiment

Navigational accuracy resulting from sidetone signals relayed by two synchronous ATS-1 and ATS-3 satellites and application to aircraft navigation

Dubose, J. F.↗

Target contrast considerations in millimeter wave radiometry for airborne navigation

Target signal requirements for aircraft navigation systems that use radiometric receivers which map thermally emitted power radiated by terrain or power radiated by ground-based beacons are discussed. For selected millimeter wavelength bands, microwaves suffer relatively little degradation by absorption or scattering on passage through the atmosphere, despite extreme weather variations. Interest centers on 8-millimeter waves because of component availability, portability (small size), high image resolution, and all-weather capability at this wavelength. The idea of radiometric airborne navigation is introduced. Elements of radiometry, terrain radiation, and atmospheric transmission characteristics are reviewed. Data pertaining to these elements at 8 mm wavelength are collected. Calculation of radiometric contrasts is discussed for some simple models of terrain targets.

Mayer, A.↗

Experiment D005: Star occultation navigation

The usefulness of star occultation measurements for space navigation and the determination of a horizon density profile which could be used to update atmospheric models for horizon-based measurement systems were studied. The time of occultation of a known star by a celestial body, as seen by an orbiting observer, determines a cylinder of position, the axis of which is the line through the star and the body center, and the radius of which is equal to the occulting-body radius. The dimming percentage, with respect to the altitude of this grazing ray from the star to the observer, is a percentage altitude for occultation. That is, the star can be assumed to be occulted when it reaches a predetermined percentage of its unattenuated value. The procedure used was to measure this attenuation with respect to time to determine the usefulness of the measurements for autonomous space navigation. In this experiment, the crewmembers had to accomplish star acquisition, identification, calibration, and tracking. Instrumentation was required only for measurement of the relative intensity of the star as it set into the atmosphere.

Silva, R. M.↗

Experiment T002: Manual navigation sightings

Navigation-type measurements through the window of the stabilized Gemini 12 spacecraft by the use of a hand-held sextant are reported. The major objectives were as follows: (1) to evaluate the ability of the crewmen to make accurate navigational measurements by the use of simple instruments in an authentic space flight environment; (2) to evaluate the operational feasibility of the measurement techniques by the use of the pressure suit with the helmet off and with the helmet on and the visor closed; (3) to evaluate operational problems associated with the spacecraft environment; and (4) to validate ground based simulation techniques by comparison of the inflight results with base line data obtained by the pilot by the use of simulators and celestial targets from ground based observatories.

Smith, D.↗