Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “mount”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Experimental investigation of the performance of vortex generators mounted in the supersonic portion of a mixed-compression inlet

Vortex generators were investigated as a means of controlling the throat boundary layer in a Mach 2.5 mixed-compression inlet. With or without throat bleed, the generators were unable to produce the inlet peak recoveries available with good performance bleed. Generators placed on the unbled inlet centerbody ahead of the cowl shock impingement point degraded inlet performance. Generators placed further aft on the unbled centerbody, but ahead of the throat, improved inlet performance at conditions where the terminal shock could cause boundary layer separation. Adding generators to the inlet with throat bleed reduced performance. Bleed aft of the generators degraded the vortex flow field.

Michell, G. A.↗

Aerodynamic characteristics of the North American Rockwell space shuttle delta-wing orbiter (110C) alone and with belly-mounted external oxygen/hydrogen tanks (M equals 0.6 to 5.0)

Experimental aerodynamic investigations were conducted at the MSFC 14 x 14 inch trisonic wind tunnel on a .0044 scale model of the space shuttle orbiter, 110C. The test configurations included the orbiter alone and with external oxygen/hydrogen belly tanks. The six component aerodynamic force and moment data obtained cover a Mach number range from 0.6 to 4.96 at angles of attack from 10 to 60 deg at 0 deg sideslip angle and -10 to 10 deg at -6 deg sideslip angle. Reynolds number per unit length varied somewhat with Mach number but was a nominal 6.8 million per foot.

Allen, E. C.↗

Strain arrestor plate for mounting rigid insulating tiles

Plate is made of material having coefficient to thermal expansion similar to that of insulating material. Although plate may be formed from appropriate alloy, it has been found that a combination of graphite fibers in epoxy resin is satisfactory and much lighter in weight.

Kural, M. H.↗

Investigation of substrate-mounted thin-film meteoroid sensors for use in large area impact experiments

Two types of sensor designs were investigated: (1)a polysulfone dielectric film with vapor-deposited aluminum and gold sensor plates, bonded to a relatively thick aluminum substrate, and (2) an aluminum oxide (A1203) dielectric layer prepared on an aluminum substrate by anodization, with a layer of vapor-deposited aluminum providing one sensor plate and the substrate serving as the other plate. In the first design, specimens were prepared which indicate the state of the art for application of this type of sensor for elements of a meteoroid detection system having an area as large as 10 sq M. Techniques were investigated for casting large-area polysulfone films on the surface of water and for transferring the films from the water. Methods of preparing sensors by layering of films, the deposition of capacitor plates, and sensor film-to-substrate bonding, as well as techniques for making electrical connections to the capacitor plates, were studied.

Carollo, S. F.↗

Performance of gas-lubricated nonconforming pivoted-pad journal bearings and a flexibly mounted spiral-groove thrust bearing

A test program was conducted to determine the performance characteristics of gas-lubricated nonconforming pivoted-pad journal bearings and a spiral-groove thrust bearing designed for the Brayton cycle rotating unit (BRU). Hydrostatic, hybrid (simultaneously hydrostatic and hydrodynamic), and hydrodynamic tests were conducted in argon gas at ambient pressure and temperature ranges representative of hydrostatic operation up to the 10.5-kWe BRU power-generating level. Performance of the gas lubricated bearings is presented, including hydrostatic gas flow rates, bearing clearances, bearing temperatures, and transient performance.

Ream, L. W.↗

Apollo telescope mount SEC camera tube spares program

An important engineering improvement was made during the Spares Program. The thermionic cathode structure was modified to bring the cathode temperature to a more suitable value and shields were placed over the glass-to-metal interface of the stem leads to reduce the possibility of interelectrode leakage. The cathode temperature change has resulted in a corresponding change in the recommended operating conditions for the heater of the thermionic cathode. All tubes built during the 1972-1973 ATM Spares Program should be operated with a heater current of 150 mA (6.3 volts). Operation at lower currents and voltages adversely affects the life of these tubes.

Green, M.↗

Flight calibration tests of a nose-boom-mounted fixed hemispherical flow-direction sensor

Flight calibrations of a fixed hemispherical flow angle-of-attack and angle-of-sideslip sensor were made from Mach numbers of 0.5 to 1.8. Maneuvers were performed by an F-104 airplane at selected altitudes to compare the measurement of flow angle of attack from the fixed hemispherical sensor with that from a standard angle-of-attack vane. The hemispherical flow-direction sensor measured differential pressure at two angle-of-attack ports and two angle-of-sideslip ports in diametrically opposed positions. Stagnation pressure was measured at a center port. The results of these tests showed that the calibration curves for the hemispherical flow-direction sensor were linear for angles of attack up to 13 deg. The overall uncertainty in determining angle of attack from these curves was plus or minus 0.35 deg or less. A Mach number position error calibration curve was also obtained for the hemispherical flow-direction sensor. The hemispherical flow-direction sensor exhibited a much larger position error than a standard uncompensated pitot-static probe.

Armistead, K. H.↗

The diluter-demand oxygen system used during the international Himalayan expedition to Mount Everest.

The diluter-demand regulators are designed in such a way that as the individual inspires he simultaneously draws ambient air and pure oxygen from a tank into his mask. The size of the ambient air orifice is made directly proportional to the barometric pressure by use of a passive aneroid valve. As altitude increases the ambient air orifice is automatically made smaller and the individual inspires a greater proportion of oxygen.

Blume, F. D.↗