Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “minimum”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Specific Features of the IR Reflectance and Raman Spectra of Sb{sub 2}Te{sub 3 –} {sub x}Se{sub x} Crystals

A comprehensive study (X-ray phase analysis, Raman spectroscopy, and IR reflectance measurements) of p-Sb{sub 2}Te{sub 3 –} {sub x}Se{sub x} (0 ≤ x ≤ 0.10) crystals synthesized by the Czochralski method is carried out. The X-ray phase data and Raman spectra show that all of the alloy samples under study are rhombohedral crystals in structure, with unit-cell parameters close to those of Sb{sub 2}Te{sub 3} crystals. At the same time, the formation of regions with different degrees of the replacement of Te atoms with Se atoms is observed. The reflectance spectra of the crystals, R(ν), have a characteristic minimum at about 1000 cm{sup –1}. The minimum is attributed to hole plasma vibrations. The plasma minimum systematically shifts to higher frequencies, as the Se content is increased. Calculation of the reflectance spectra in the context of the Drude–Lorentz model satisfactorily describes the experimental data; in this case, it is necessary to take into account also the contribution of optical crystal-lattice vibrations to spectra in the low-frequency region. The calculation makes it possible to determine the optical parameters of the crystals and to estimate the hole effective mass and the optical conductivity.

36 MATERIALS SCIENCE↗

CATS v. 2

This program calculates performance characteristics for a split flow recompression closed Brayton cycle. The user defines for the cycle; minimum temperature, minimum pressure, maximum temperature, maximum pressure, pinch temperature at the cold ends of the low temperature and high temperature recuperators, component fractional pressure drop, and efficiencies for each of the two turbines and each of the two compressors. All of these parameters except component fractional pressure drop and turbomachinery efficiencies are varies in separate do loops. In this way, minimum and maximum values for each of these parameters can be set. Results from each iteration are saved to a .csv file. Following completion of the program run, the .csv file can be read into a plotting package and the results can be plotted.

Pasch, James↗

Characterization of elastic mechanical properties of Tuscaloosa Marine Shale from well logs using the vertical transversely isotropic model

To avoid steep declines in the Tuscaloosa Marine Shale (TMS) production, wells are fracture-stimulated to release the hydrocarbons trapped in the matrix of the formation. An accurate estimation of Young’s modulus and Poisson’s ratio is essential for hydraulic fracture propagation. In addition, ignoring the highly heterogeneous and anisotropic character of TMS can lead to erroneous stress values, which subsequently affect hydraulic fracture width estimates and the overall hydraulic fracturing process. We have developed an empirical 1D geomechanical model that takes into account VTI anisotropy, and it is used to characterize the elastic mechanical properties of TMS in two wells. In the analyzed formation, the vertical Poisson’s ratio is less than the horizontal Poisson’s ratio, which suggests the necessity of an alternative to the ANNIE equations. The stiffness coefficients [Formula: see text] and [Formula: see text] were estimated using the relationships developed from the ultrasonic core data available for the two TMS. Further, correlations between the static and dynamic properties from laboratory tests were used to improve the minimum horizontal stress calculation. We compare VTI Young’s moduli, Poisson’s ratios, and minimum horizontal stress with the isotropic solution. VTI modeling improves the estimation of the elastic mechanical properties. The isotropic solution underestimates the minimum horizontal stress in the formation. Moreover, it was shown that the 20 ft shale interval below the TMS base is characterized by a low Young’s modulus (the vertical Young’s modulus is equal to 20 GPa, whereas the horizontal Young’s modulus is equal to 40 GPa) and may be a frac barrier.

Geochemistry & Geophysics↗

Data from Biodiesel Production from Engineered Sugarcane Lipids under Uncertain Feedstock Compositions: Process Design and Techno-Economic Analysis

In this study, different process schemes were designed and evaluated for biodiesel production from engineered cane lipids with uncertain fatty acid compositions. Four different process schemes were compared under (i) thermal glycerolysis and (ii) enzymatic glycerolysis approaches. These schemes were based on the biodiesel yield and economic indicators such as the net present value (NPV) and the minimum selling price (MSP) of biodiesel. A scheme with polar lipid separation under thermal glycerolysis resulted in the maximum NPV ($96.5 million) and minimum MSP ($1107/ton biodiesel), respectively. Through local sensitivity analysis, it was concluded that the cane lipid percentage is the most significant factor influencing process economics. A conjoint analysis of the lipid procurement price and cane lipid percent suggested that 15% cane lipids with a low lipid procurement price ($0.536/kg) results in a positive NPV. When the cane lipid price is higher (>$0.80/kg), a 20% lipid content should be considered to achieve a positive NPV. At 20% cane lipids, the worst-case and best-case scenarios were evaluated by analyzing the interplay of the three most important parameters, The best-case scenario revealed that the minimum NPV under any process scheme could yield more than $100 million (or MSP: $0.80/L), and the worst-case analysis showed that losses incurred by the plant could be as high as $80 million (MSP: $1.36/L). A Monte Carlo simulation indicated that there is a 70% chance of the plant being profitable (NPV > 0).

Conversion↗

Slip and Dilation Tendency Analysis of the Tuscarora Geothermal Area

Critically stressed fault segments have a relatively high likelihood of acting as fluid flow conduits (Sibson, 1994). As such, the tendency of a fault segment to slip (slip tendency; Ts; Morris et al., 1996) or to dilate (dilation tendency; Td; Ferrill et al., 1999) provides an indication of which faults or fault segments within a geothermal system are critically stressed and therefore likely to transmit geothermal fluids. The slip tendency of a surface is defined by the ratio of shear stress to normal stress on that surface: Ts = T / on (Morris et al., 1996). Dilation tendency is defined by the stress acting normal to a given surface: Td = (o1-on) / (o1-o3) (Ferrill et al., 1999). Slip and dilation were calculated using 3DStress (Southwest Research Institute). Slip and dilation tendency are both unitless ratios of the resolved stresses applied to the fault plane by ambient stress conditions. Values range from a maximum of 1, a fault plane ideally oriented to slip or dilate under ambient stress conditions to zero, a fault plane with no potential to slip or dilate. Slip and dilation tendency values were calculated for each fault in the focus study areas at, McGinness Hills, Neal Hot Springs, Patua, Salt Wells, San Emidio, and Tuscarora on fault traces. As dip is not well constrained or unknown for many faults mapped in within these we made these calculations using the dip for each fault that would yield the maximum slip tendency or dilation tendency. As such, these results should be viewed as maximum tendency of each fault to slip or dilate. The resulting along-fault and fault-to-fault variation in slip or dilation potential is a proxy for along fault and fault-to-fault variation in fluid flow conduit potential. Stress Magnitudes and directions Stress field variation within each focus area was approximated based on regional published data and the world stress database (Hickman et al., 2000; Hickman et al., 1998 Robertson-Tait et al., 2004; Hickman and Davatzes, 2010; Davatzes and Hickman, 2006; Blake and Davatzes 2011; Blake and Davatzes, 2012; Moeck et al., 2010; Moos and Ronne, 2010 and Reinecker et al., 2005) as well as local stress information if applicable. For faults within these focus systems we applied either a normal faulting stress regime where the vertical stress (sv) is larger than the maximum horizontal stress (shmax) which is larger than the minimum horizontal stress (sv>shmax>shmin) or strike-slip faulting stress regime where the maximum horizontal stress (shmax) is larger than the vertical stress (sv) which is larger than the minimum horizontal stress (shmax >sv>shmin) depending on the general tectonic province of the system. Based on visual inspection of the limited stress magnitude data in the Great Basin we used magnitudes such that shmin/shmax = .527 and shmin/sv= .46, which are consistent with complete and partial stress field determinations from Desert Peak, Coso, the Fallon area and Dixie valley (Hickman et al., 2000; Hickman et al., 1998 Robertson-Tait et al., 2004; Hickman and Davatzes, 2011; Davatzes and Hickman, 2006; Blake and Davatzes 2011; Blake and Davatzes, 2012). Slip and dilation tendency for the Tuscarora geothermal field was calculated based on the faults mapped Tuscarora area (Dering, 2013). The Tuscarora area lies in the Basin and Range Province, as such we applied a normal faulting stress regime to the Tuscarora area faults, with a minimum horizontal stress direction oriented 115, based on inspection of local and regional stress determinations, as explained above. Under these stress conditions north-northeast striking, steeply dipping fault segments have the highest dilation tendency, while north-northeast striking 60 degrees dipping fault segments have the highest tendency to slip. Tuscarora is defined by a left-step in a major north- to-north northeast striking, west-dipping range-bounding normal fault system. Faults within the broad step define an anticlinal accommodation ...

15 GEOTHERMAL ENERGY↗

Slip and Dilation Tendency Analysis of the San Emidio Geothermal Area

Critically stressed fault segments have a relatively high likelihood of acting as fluid flow conduits (Sibson, 1994). As such, the tendency of a fault segment to slip (slip tendency; Ts; Morris et al., 1996) or to dilate (dilation tendency; Td; Ferrill et al., 1999) provides an indication of which faults or fault segments within a geothermal system are critically stressed and therefore likely to transmit geothermal fluids. The slip tendency of a surface is defined by the ratio of shear stress to normal stress on that surface: Ts = T / on (Morris et al., 1996). Dilation tendency is defined by the stress acting normal to a given surface: Td = (o1-on) / (o1-o3) (Ferrill et al., 1999). Slip and dilation were calculated using 3DStress (Southwest Research Institute). Slip and dilation tendency are both unitless ratios of the resolved stresses applied to the fault plane by ambient stress conditions. Values range from a maximum of 1, a fault plane ideally oriented to slip or dilate under ambient stress conditions to zero, a fault plane with no potential to slip or dilate. Slip and dilation tendency values were calculated for each fault in the focus study areas at, McGinness Hills, Neal Hot Springs, Patua, Salt Wells, San Emidio, and Tuscarora on fault traces. As dip is not well constrained or unknown for many faults mapped in within these we made these calculations using the dip for each fault that would yield the maximum slip tendency or dilation tendency. As such, these results should be viewed as maximum tendency of each fault to slip or dilate. The resulting along-fault and fault-to-fault variation in slip or dilation potential is a proxy for along fault and fault-to-fault variation in fluid flow conduit potential. Stress Magnitudes and directions Stress field variation within each focus area was approximated based on regional published data and the world stress database (Hickman et al., 2000; Hickman et al., 1998 Robertson-Tait et al., 2004; Hickman and Davatzes, 2010; Davatzes and Hickman, 2006; Blake and Davatzes 2011; Blake and Davatzes, 2012; Moeck et al., 2010; Moos and Ronne, 2010 and Reinecker et al., 2005) as well as local stress information if applicable. For faults within these focus systems we applied either a normal faulting stress regime where the vertical stress (sv) is larger than the maximum horizontal stress (shmax) which is larger than the minimum horizontal stress (sv>shmax>shmin) or strike-slip faulting stress regime where the maximum horizontal stress (shmax) is larger than the vertical stress (sv) which is larger than the minimum horizontal stress (shmax >sv>shmin) depending on the general tectonic province of the system. Based on visual inspection of the limited stress magnitude data in the Great Basin we used magnitudes such that shmin/shmax = .527 and shmin/sv= .46, which are consistent with complete and partial stress field determinations from Desert Peak, Coso, the Fallon area and Dixie valley (Hickman et al., 2000; Hickman et al., 1998 Robertson-Tait et al., 2004; Hickman and Davatzes, 2011; Davatzes and Hickman, 2006; Blake and Davatzes 2011; Blake and Davatzes, 2012). Slip and dilation tendency for the San Emidio geothermal field was calculated based on the faults mapped Tuscarora area (Rhodes, 2011). The San Emidio area lies in the Basin and Range Province, as such we applied a normal faulting stress regime to the San Emidio area faults, with a minimum horizontal stress direction oriented 115, based on inspection of local and regional stress determinations, as explained above. This is consistent with the shmin determined through inversion of fault data by Rhodes (2011). Under these stress conditions north-northeast striking, steeply dipping fault segments have the highest dilation tendency, while north-northeast striking 60 degrees dipping fault segments have the highest tendency to slip. Interesting, the San Emidio geothermal field lies in an area of primarily north striking faults, w...

15 GEOTHERMAL ENERGY↗

Slip and Dilation Tendency Analysis of the Salt Wells Geothermal Area

Critically stressed fault segments have a relatively high likelihood of acting as fluid flow conduits (Sibson, 1994). As such, the tendency of a fault segment to slip (slip tendency; Ts; Morris et al., 1996) or to dilate (dilation tendency; Td; Ferrill et al., 1999) provides an indication of which faults or fault segments within a geothermal system are critically stressed and therefore likely to transmit geothermal fluids. The slip tendency of a surface is defined by the ratio of shear stress to normal stress on that surface: Ts = T / on (Morris et al., 1996). Dilation tendency is defined by the stress acting normal to a given surface: Td = (o1-on) / (o1-o3) (Ferrill et al., 1999). Slip and dilation were calculated using 3DStress (Southwest Research Institute). Slip and dilation tendency are both unitless ratios of the resolved stresses applied to the fault plane by ambient stress conditions. Values range from a maximum of 1, a fault plane ideally oriented to slip or dilate under ambient stress conditions to zero, a fault plane with no potential to slip or dilate. Slip and dilation tendency values were calculated for each fault in the focus study areas at, McGinness Hills, Neal Hot Springs, Patua, Salt Wells, San Emidio, and Tuscarora on fault traces. As dip is not well constrained or unknown for many faults mapped in within these we made these calculations using the dip for each fault that would yield the maximum slip tendency or dilation tendency. As such, these results should be viewed as maximum tendency of each fault to slip or dilate. The resulting along-fault and fault-to-fault variation in slip or dilation potential is a proxy for along fault and fault-to-fault variation in fluid flow conduit potential. Stress Magnitudes and directions Stress field variation within each focus area was approximated based on regional published data and the world stress database (Hickman et al., 2000; Hickman et al., 1998 Robertson-Tait et al., 2004; Hickman and Davatzes, 2010; Davatzes and Hickman, 2006; Blake and Davatzes 2011; Blake and Davatzes, 2012; Moeck et al., 2010; Moos and Ronne, 2010 and Reinecker et al., 2005) as well as local stress information if applicable. For faults within these focus systems we applied either a normal faulting stress regime where the vertical stress (sv) is larger than the maximum horizontal stress (shmax) which is larger than the minimum horizontal stress (sv>shmax>shmin) or strike-slip faulting stress regime where the maximum horizontal stress (shmax) is larger than the vertical stress (sv) which is larger than the minimum horizontal stress (shmax >sv>shmin) depending on the general tectonic province of the system. Based on visual inspection of the limited stress magnitude data in the Great Basin we used magnitudes such that shmin/shmax = .527 and shmin/sv= .46, which are consistent with complete and partial stress field determinations from Desert Peak, Coso, the Fallon area and Dixie valley (Hickman et al., 2000; Hickman et al., 1998 Robertson-Tait et al., 2004; Hickman and Davatzes, 2011; Davatzes and Hickman, 2006; Blake and Davatzes 2011; Blake and Davatzes, 2012). Slip and dilation tendency for the Salt Wells geothermal field was calculated based on the faults mapped in the Bunejug Mountains quadrangle (Hinz et al., 2011). The Salt Wells area lies in the Basin and Range Province (N. Hinz personal comm.) As such we applied a normal faulting stress regime to the Salt Wells area faults, with a minimum horizontal stress direction oriented 105, based on inspection of local and regional stress determinations. Under these stress conditions north-northeast striking, steeply dipping fault segments have the highest dilation tendency, while north-northeast striking 60 degrees dipping fault segments have the highest tendency to slip. Several such faults intersect in high density in the core of the accommodation zone in the Bunejug Mountains and local to the Salt Wells geothermal .

15 GEOTHERMAL ENERGY↗

Slip and Dilation Tendency Analysis of McGinness Hills Geothermal Area

Slip and Dilation Tendency in focus areas Critically stressed fault segments have a relatively high likelihood of acting as fluid flow conduits (Sibson, 1994). As such, the tendency of a fault segment to slip (slip tendency; Ts; Morris et al., 1996) or to dilate (dilation tendency; Td; Ferrill et al., 1999) provides an indication of which faults or fault segments within a geothermal system are critically stressed and therefore likely to transmit geothermal fluids. The slip tendency of a surface is defined by the ratio of shear stress to normal stress on that surface: Ts = T / on (Morris et al., 1996). Dilation tendency is defined by the stress acting normal to a given surface: Td = (o1-on) / (o1-o3) (Ferrill et al., 1999). Slip and dilation were calculated using 3DStress (Southwest Research Institute). Slip and dilation tendency are both unitless ratios of the resolved stresses applied to the fault plane by ambient stress conditions. Values range from a maximum of 1, a fault plane ideally oriented to slip or dilate under ambient stress conditions to zero, a fault plane with no potential to slip or dilate. Slip and dilation tendency values were calculated for each fault in the focus study areas at, McGinness Hills, Neal Hot Springs, Patua, Salt Wells, San Emidio, and Tuscarora on fault traces. As dip is not well constrained or unknown for many faults mapped in within these we made these calculations using the dip for each fault that would yield the maximum slip tendency or dilation tendency. As such, these results should be viewed as maximum tendency of each fault to slip or dilate. The resulting along-fault and fault-to-fault variation in slip or dilation potential is a proxy for along fault and fault-to-fault variation in fluid flow conduit potential. Stress Magnitudes and directions Stress field variation within each focus area was approximated based on regional published data and the world stress database (Hickman et al., 2000; Hickman et al., 1998 Robertson-Tait et al., 2004; Hickman and Davatzes, 2010; Davatzes and Hickman, 2006; Blake and Davatzes 2011; Blake and Davatzes, 2012; Moeck et al., 2010; Moos and Ronne, 2010 and Reinecker et al., 2005) as well as local stress information if applicable. For faults within these focus systems we applied either a normal faulting stress regime where the vertical stress (sv) is larger than the maximum horizontal stress (shmax) which is larger than the minimum horizontal stress (sv>shmax>shmin) or strike-slip faulting stress regime where the maximum horizontal stress (shmax) is larger than the vertical stress (sv) which is larger than the minimum horizontal stress (shmax >sv>shmin) depending on the general tectonic province of the system. Based on visual inspection of the limited stress magnitude data in the Great Basin we used magnitudes such that shmin/shmax = .527 and shmin/sv= .46, which are consistent with complete and partial stress field determinations from Desert Peak, Coso, the Fallon area and Dixie valley (Hickman et al., 2000; Hickman et al., 1998 Robertson-Tait et al., 2004; Hickman and Davatzes, 2011; Davatzes and Hickman, 2006; Blake and Davatzes 2011; Blake and Davatzes, 2012). Slip and dilation tendency for the McGinness Hills geothermal field was calculated based on the faults mapped McGinness Hills area (Siler 2012, unpublished). The McGinness Hills area lies in the Basin and Range Province, as such we applied a normal faulting stress regime to the McGinness area faults, with a minimum horizontal stress direction oriented 115, based on inspection of local and regional stress determinations, as explained above. Under these stress conditions north-northeast striking, steeply dipping fault segments have the highest dilation tendency, while north-northeast striking 60 degrees dipping fault segments have the highest tendency to slip. The McGinness Hills geothermal system is characterized by a left-step in a north-northeast striking west-dipping fault system...

15 GEOTHERMAL ENERGY↗

Recent streamflow trends across permafrost basins of North America: Datasets

Climate change impacts, including changing temperatures, precipitation, and vegetation, are widely anticipated to cause major shifts to the permafrost with resulting impacts to hydro-ecosystems across the high latitudes of the globe. However, it is challenging to examine streamflow shifts in these regions owing to a paucity of data, discontinuity of records, and other issues related to data consistency and accuracy. We looked at recent changes in streamflow over 1976-2021 in watersheds affected by varying degrees of permafrost coverage to characterize trends and drivers for a range of watersheds across North America. Data sets are described in detail in the paper associated with this data set, Bennett et al. 2023, Front. Water - Water and Critical Zone, DOI: 10.3389/frwa.2023.1099660.These data contain CSV files of the streamflow, climate, and land surface characteristics for several sites located across the high latitude regions of North America. Both observed and reanalysis data products are provided. These files can be opened using Excel or a text editor, or they can be read, and analyzed in software tools such as Python or R. A brief description of the files is below, and more details can be found in the Methods section.rabpro_stats_north_select_74_55m.csv - This file describes the observed gages used in the analysis.GF31_23_metadat.csv - This file describes the 23 permafrost systems. Columns are as described in rabpro_stats_north_select_74_55m.csv above, with rabpro_id, the id used for the timeseries file mapping in GF31_23_time_series.csv.GF31_23_time_series.csv - This file contains the time series data for the stations described in GF31_23_metadat.csv.GF31_random_reaches_1583.csv - This file describes the 1583 randomly selected permafrost-dominant sites for machine learning analysis.era5_GF31_monthly_vars_random_reaches_1583.csv - This file contains the monthly ERA5 land data for the 1583 randomly selected permafrost-dominant sites.observed.zip: USGS and Hydat station data for the 74 gages analyzed in this study. Monthly, seasonal, and annual streamflow observations for minimum streamflow, mean streamflow, and maximum streamflow. Units are m3/sec. 1975-2022.streamflow_daily_GF31_infilled_1979_2022.csv - infilled daily streamflow data (infilled using GloFAS v 3.1) for 55 gages. Units are m3/sec. 1979-2022.glofas_23.zip - Glofas v3.1 file for the 23 permafrost-dominant gages in the study. Monthly, seasonal, and annual streamflow observations for minimum streamflow, mean streamflow, and maximum streamflow. Units are m3/sec. 1979-2021.glofas_1583.zip - Glofas v3.1 file for the 1583 randomly selected permafrost-dominant gages in the study. Monthly, seasonal, and annual streamflow observations for minimum streamflow, mean streamflow, and maximum streamflow. Units are m3/sec. 1979-2021.

54 ENVIRONMENTAL SCIENCES↗

Mountain Basin Controls on the Snow-to-Streamflow Signal: An AIC-Weighted Multiple Linear Regression Framework

A regression-based analysis quantifies how basin characteristics modulate the snow-to-streamflow signal. First, we use the ERA5-Land reanalysis gridded product (European Centre for Medium Range Weather Forecasts reanalysis 5 -Land component) for 4,655 hydrologic unit code - 10 (HUC10) mountain basins across the western United States (US) for water years 1987–2024. Linear regressions are performed for peak snow water equivalent (SWE) and annual streamflow for each mountain basin. Models use ordinary least squares in Python’s statsmodels package. After which, an Akaike Information Criterion (AIC)–weighted ensemble multiple linear regression (MLR) framework with 47 watershed traits is used to predict the linear regression coefficient of determination (r-squared) defining the ability of peak SWE to predict annual streamflow across all mountain basin. Predictor sets are constrained to avoid multicollinearity by excluding models with variance inflation factors (VIF) greater than 5. Mountain basin traits included in the MLR include seasonal climate, topography, vegetation type and structure, and bedrock geology. Accepted models are considered if their AIC is within 2.0 of the model with the minimum AIC, or best model. To compare predictor influence across acceptable models, we computed standardized regression coefficients. To evaluate structural redundancy among models, we constructed binary inclusion vectors for each acceptable model, denoting whether a predictor was present (1) or absent (0). Core predictor variables are defined as occurring in at least 67% of the acceptable models. For this regional analysis, only one model was found acceptable, with higher snow-to-streamflow translation (higher r-squared) occurring in colder mountain basins with higher relative winter precipitation, more snow accumulation and a lower fraction of annual precipitation that falls in the spring and summer. The second component of the data package uses previously published, high-resolution output from an integrated hydrological model of the East River watershed using the U.S. Geological Survey Groundwater and Surface water Flow model (GSFLOW, doi:10.15485/1998576). East River MLR expands upon the approach described above to explore the response of five streamflow metrics—annual streamflow, runoff efficiency, 7-day minimum flow, low-flow duration, and non-perennial stream fraction to snow system indicators including peak SWE, snow-covered area, snow disappearance date, and the fraction of basin area characterized by low-to-no snow, as well as seasonal precipitation and temperature, and annual hydrologic variables representing soil moisture, evapotranspiration (ET), the partitioning of incoming precipitation to evapotranspiration (ET/P), groundwater storage, and groundwater inflow to streams. MLR was done on all water years (P0: 1987-2024) and for each period as determined in the split analysis using pooled regression techniques (P1: 1987-2011 and P2: 2012-2024) to evaluate shifting predictor variable emphasis on streamflow generation. Results indicate that since 2012, peak SWE has lost statistical strength in its prediction of annual streamflow and runoff efficiency, and the indirect influence of spring temperature has emerged as critically important. Low-flow metrics remain largely influenced by soil moisture, vegetation water use and groundwater inflows with summer precipitation becoming a direct influence on minimum summer flow. Together, these data and Python-based analysis tools provide a framework for identifying the key watershed characteristics that control how streamflow responds to snow from year to year. The package also helps quantify uncertainty in statistical models and assess how snow–streamflow relationships vary across regions and over time. This dataset contains comma-separated values files (.csv), text files (.txt), python code files (.py), figure files (.png), and shapefiles (.cpg, .dbf, .prj, .sbn, .sbx, .shp, .xml). Further details on file contents and MLR execution can be found in the readme file and the FLMD files. Work was supported by the Watershed Function Science Focus Area at Lawrence Berkeley National Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-05CH11231.

54 ENVIRONMENTAL SCIENCES↗

Analysis of supercritical CO{sub 2} cycle control strategies and dynamic response for Generation IV Reactors.

The analysis of specific control strategies and dynamic behavior of the supercritical carbon dioxide (S-CO{sub 2}) Brayton cycle has been extended to the two reactor types selected for continued development under the Generation IV Nuclear Energy Systems Initiative; namely, the Very High Temperature Reactor (VHTR) and the Sodium-Cooled Fast Reactor (SFR). Direct application of the standard S-CO{sub 2} recompression cycle to the VHTR was found to be challenging because of the mismatch in the temperature drop of the He gaseous reactor coolant through the He-to-CO{sub 2} reactor heat exchanger (RHX) versus the temperature rise of the CO{sub 2} through the RHX. The reference VHTR features a large temperature drop of 450 C between the assumed core outlet and inlet temperatures of 850 and 400 C, respectively. This large temperature difference is an essential feature of the VHTR enabling a lower He flow rate reducing the required core velocities and pressure drop. In contrast, the standard recompression S-CO{sub 2} cycle wants to operate with a temperature rise through the RHX of about 150 C reflecting the temperature drop as the CO{sub 2} expands from 20 MPa to 7.4 MPa in the turbine and the fact that the cycle is highly recuperated such that the CO{sub 2} entering the RHX is effectively preheated. Because of this mismatch, direct application of the standard recompression cycle results in a relatively poor cycle efficiency of 44.9%. However, two approaches have been identified by which the S-CO{sub 2} cycle can be successfully adapted to the VHTR and the benefits of the S-CO{sub 2} cycle, especially a significant gain in cycle efficiency, can be realized. The first approach involves the use of three separate cascaded S-CO{sub 2} cycles. Each S-CO{sub 2} cycle is coupled to the VHTR through its own He-to-CO{sub 2} RHX in which the He temperature is reduced by 150 C. The three respective cycles have efficiencies of 54, 50, and 44%, respectively, resulting in a net cycle efficiency of 49.3 %. The other approach involves reducing the minimum cycle pressure significantly below the critical pressure such that the temperature drop in the turbine is increased while the minimum cycle temperature is maintained above the critical temperature to prevent the formation of a liquid phase. The latter approach also involves the addition of a precooler and a third compressor before the main compressor to retain the benefits of compression near the critical point with the main compressor. For a minimum cycle pressure of 1 MPa, a cycle efficiency of 49.5% is achieved. Either approach opens up the door to applying the SCO{sub 2} cycle to the VHTR. In contrast, the SFR system typically has a core outlet-inlet temperature difference of about 150 C such that the standard recompression cycle is ideally suited for direct application to the SFR. The ANL Plant Dynamics Code has been modified for application to the VHTR and SFR when the reactor side dynamic behavior is calculated with another system level computer code such as SAS4A/SYSSYS-1 in the SFR case. The key modification involves modeling heat exchange in the RHX, accepting time dependent tabular input from the reactor code, and generating time dependent tabular input to the reactor code such that both the reactor and S-CO{sub 2} cycle sides can be calculated in a convergent iterative scheme. This approach retains the modeling benefits provided by the detailed reactor system level code and can be applied to any reactor system type incorporating a S-CO{sub 2} cycle. This approach was applied to the particular calculation of a scram scenario for a SFR in which the main and intermediate sodium pumps are not tripped and the generator is not disconnected from the electrical grid in order to enhance heat removal from the reactor system thereby enhancing the cooldown rate of the Na-to-CO{sub 2} RHX. The reactor side is calculated with SAS4A/SASSYS-1 while the S-CO{sub 2} cycle is calculated with the Plant Dynamics Code with a number of iterations over a timescale of 500 seconds. It is found that the RHX undergoes a maximum cooldown rate of {approx} -0.3 C/s. The Plant Dynamics Code was also modified to decrease its running time by replacing the compressible flow form of the momentum equation with an incompressible flow equation for use inside of the cooler or recuperators where the CO{sub 2} has a compressibility similar to that of a liquid. Appendices provide a quasi-static control strategy for a SFR as well as the self-adaptive linear function fitting algorithm developed to produce the tabular data for input to the reactor code and Plant Dynamics Code from the detailed output of the other code.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

GRiP - A flexible approach for calculating risk as a function of consequence, vulnerability, and threat.

Get a GRiP (Gravitational Risk Procedure) on risk by using an approach inspired by the physics of gravitational forces between body masses! In April 2010, U.S. Department of Homeland Security Special Events staff (Protective Security Advisors [PSAs]) expressed concern about how to calculate risk given measures of consequence, vulnerability, and threat. The PSAs believed that it is not 'right' to assign zero risk, as a multiplicative formula would imply, to cases in which the threat is reported to be extremely small, and perhaps could even be assigned a value of zero, but for which consequences and vulnerability are potentially high. They needed a different way to aggregate the components into an overall measure of risk. To address these concerns, GRiP was proposed and developed. The inspiration for GRiP is Sir Isaac Newton's Universal Law of Gravitation: the attractive force between two bodies is directly proportional to the product of their masses and inversely proportional to the squares of the distance between them. The total force on one body is the sum of the forces from 'other bodies' that influence that body. In the case of risk, the 'other bodies' are the components of risk (R): consequence, vulnerability, and threat (which we denote as C, V, and T, respectively). GRiP treats risk as if it were a body within a cube. Each vertex (corner) of the cube represents one of the eight combinations of minimum and maximum 'values' for consequence, vulnerability, and threat. The risk at each of the vertices is a variable that can be set. Naturally, maximum risk occurs when consequence, vulnerability, and threat are at their maximum values; minimum risk occurs when they are at their minimum values. Analogous to gravitational forces among body masses, the GRiP formula for risk states that the risk at any interior point of the box depends on the squares of the distances from that point to each of the eight vertices. The risk value at an interior (movable) point will be dominated by the value of one vertex as that point moves closer and closer to that one vertex. GRiP is a visualization tool that helps analysts better understand risk and its relationship to consequence, vulnerability, and threat. Estimates of consequence, vulnerability, and threat are external to GRiP; however, the GRiP approach can be linked to models or data that provide estimates of consequence, vulnerability, and threat. For example, the Enhanced Critical Infrastructure Program/Infrastructure Survey Tool produces a vulnerability index (scaled from 0 to 100) that can be used for the vulnerability component of GRiP. We recognize that the values used for risk components can be point estimates and that, in fact, there is uncertainty regarding the exact values of C, V, and T. When we use T = t{sub o} (where t{sub o} is a value of threat in its range), we mean that threat is believed to be in an interval around t{sub o}. Hence, a value of t{sub o} = 0 indicates a 'best estimate' that the threat level is equal to zero, but still allows that it is not impossible for the threat to occur. When t{sub o} = 0 but is potentially small and not exactly zero, there will be little impact on the overall risk value as long as the C and V components are not large. However, when C and/or V have large values, there can be large differences in risk given t{sub o} = 0, and t{sub o} = epsilon (where epsilon is small but greater than a value of zero). We believe this scenario explains the PSA's intuition that risk is not equal to zero when t{sub o} = 0 and C and/or V have large values. (They may also be thinking that if C has an extremely large value, it is unlikely that T is equal to 0; in the terrorist context, T would likely be dependent on C when C is extremely large.) The PSAs are implicitly recognizing the potential that t{sub o} = epsilon. One way to take this possible scenario into account is to replace point estimates for risk with interval values that reflect the uncertainty in the risk components. In fact, one could argue that T never equals zero for a man-made hazard. This paper describes the thought process that led to the GRiP approach and the mathematical formula for GRiP and presents a few examples that will provide insights about how to use GRiP and interpret its results.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

TANK48 CFD MODELING ANALYSIS

The process of recovering the waste in storage tanks at the Savannah River Site (SRS) typically requires mixing the contents of the tank to ensure uniformity of the discharge stream. Mixing is accomplished with one to four dual-nozzle slurry pumps located within the tank liquid. For the work, a Tank 48 simulation model with a maximum of four slurry pumps in operation has been developed to estimate flow patterns for efficient solid mixing. The modeling calculations were performed by using two modeling approaches. One approach is a single-phase Computational Fluid Dynamics (CFD) model to evaluate the flow patterns and qualitative mixing behaviors for a range of different modeling conditions since the model was previously benchmarked against the test results. The other is a two-phase CFD model to estimate solid concentrations in a quantitative way by solving the Eulerian governing equations for the continuous fluid and discrete solid phases over the entire fluid domain of Tank 48. The two-phase results should be considered as the preliminary scoping calculations since the model was not validated against the test results yet. A series of sensitivity calculations for different numbers of pumps and operating conditions has been performed to provide operational guidance for solids suspension and mixing in the tank. In the analysis, the pump was assumed to be stationary. Major solid obstructions including the pump housing, the pump columns, and the 82 inch central support column were included. The steady state and three-dimensional analyses with a two-equation turbulence model were performed with FLUENT{trademark} for the single-phase approach and CFX for the two-phase approach. Recommended operational guidance was developed assuming that local fluid velocity can be used as a measure of sludge suspension and spatial mixing under single-phase tank model. For quantitative analysis, a two-phase fluid-solid model was developed for the same modeling conditions as the single-phase model. The modeling results show that the flow patterns driven by four pump operation satisfy the solid suspension requirement, and the average solid concentration at the plane of the transfer pump inlet is about 12% higher than the tank average concentrations for the 70 inch tank level and about the same as the tank average value for the 29 inch liquid level. When one of the four pumps is not operated, the flow patterns are satisfied with the minimum suspension velocity criterion. However, the solid concentration near the tank bottom is increased by about 30%, although the average solid concentrations near the transfer pump inlet have about the same value as the four-pump baseline results. The flow pattern results show that although the two-pump case satisfies the minimum velocity requirement to suspend the sludge particles, it provides the marginal mixing results for the heavier or larger insoluble materials such as MST and KTPB particles. The results demonstrated that when more than one jet are aiming at the same position of the mixing tank domain, inefficient flow patterns are provided due to the highly localized momentum dissipation, resulting in inactive suspension zone. Thus, after completion of the indexed solids suspension, pump rotations are recommended to avoid producing the nonuniform flow patterns. It is noted that when tank liquid level is reduced from the highest level of 70 inches to the minimum level of 29 inches for a given number of operating pumps, the solid mixing efficiency becomes better since the ratio of the pump power to the mixing volume becomes larger. These results are consistent with the literature results.

99 GENERAL AND MISCELLANEOUS↗

Puncture Test Characterization of Glovebox Gloves

An experiment was conducted to determine the puncture resistance of 15 gloves that are used or proposed for use in the Tritium Facility at Savannah River Site (SRS). These data will serve as a baseline for characterization and may be incorporated into the glove procurement specification. The testing was conducted in agreement with ASTM D120 and all of the gloves met or exceeded the minimum requirements. Butyl gloves exhibited puncture resistance nearly 2.5 times the minimum requirements at SRS while Polyurethane was nearly 7.5x the minimum.

36 MATERIALS SCIENCE↗

Simulation Analyses in Support of DOE’s Fossil Fuel Rule for Single Component Equipment and Lighting Replacements

At the request of the US Department of Energy’s (DOE) Federal Energy Management Program (FEMP), Pacific Northwest National Laboratory (PNNL) conducted a series of building energy simulations using a large office model to investigate the potential savings that could be accrued from a typical chiller, boiler, or lighting replacement in a Federal office building. FEMP’s interest was in knowing whether or not single component replacements like these would have any chance of achieving the fossil- fuel-based energy consumption reduction requirements specified in Section 433 of the Energy Independence and Security Act (EISA) of 20071. Specifically, FEMP was interested in whether an older Federal building, built in the 1980s or 1990s and designed to meet energy standards in place at the time the building was designed, could meet the requirements of Section 433 of EISA for renovations. Many single component renovations like chiller replacements, boiler replacements, and lighting retrofits may meet the minimum cost requirement of Section 433 of EISA but may not offer any opportunity to achieve fossil-fuel-generated energy consumption reductions on the order of 55% or more. If single component renovations such as these would not achieve the necessary reductions, then FEMP would consider modifying rules based on Section 433 of EISA to exempt these types of single component renovations from the overall fossil-fuel-generated energy consumption reduction provisions. FEMP would instead require Federal agencies to ensure that these renovations use FEMP-designated efficiencies for chillers and boilers or the lighting power density requirements found in ASHRAE Standard 90.1-2010. The results of PNNL’s analysis indicated that it is unlikely that a combined boiler and chiller replacement, or an individual boiler or chiller replacement in an older existing Federal building would meet the requirements of Section 433 of EISA. While buildings can achieve up to 34% reduction in cooling and 11% reduction in heating load with this type of retrofit, these savings fall well short of the minimum savings specified in Section 433 of EISA. Similarly, a lighting retrofit in an older existing Federal building would also not likely meet the requirements of Section 433 of EISA. While buildings can save up to 52% on lighting loads, the whole buildings savings would be well short of the minimum savings specified in Section 433 of EISA.

Halverson, Mark A.↗

Vapor Space Corrosion Testing Simulating The Environment Of Hanford Double Shell Tanks

As part of an integrated program to better understand corrosion in the high level waste tanks, Hanford has been investigating corrosion at the liquid/air interface (LAI) and at higher areas in the tank vapor space. This current research evaluated localized corrosion in the vapor space over Hanford double shell tank simulants to assess the impact of ammonia and new minimum nitrite concentration limits, which are part of the broader corrosion chemistry limits. The findings from this study showed that the presence of ammonia gas (550 ppm) in the vapor space is sufficient to reduce corrosion over the short-term (i.e. four months) for a Hanford waste chemistry (SY102 High Nitrate). These findings are in agreement with previous studies at both Hanford and SRS which showed ammonia gas in the vapor space to be inhibitive. The presence of ammonia in electrochemical test solution, however, was insufficient to inhibit against pitting corrosion. The effect of the ammonia appears to be a function of the waste chemistry and may have more significant effects in waste with low nitrite concentrations. Since high levels of ammonia were found beneficial in previous studies, additional testing is recommended to assess the necessary minimum concentration for protection of carbon steel. The new minimum R value of 0.15 was found to be insufficient to prevent pitting corrosion in the vapor space. The pitting that occurred, however, did not progress over the four-month test. Pits appeared to stop growing, which would indicate that pitting might not progress through wall.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Investigation of Gas Solid Fluidized Bed Dynamics with Non-Spherical Particles

One of the largest challenges for 21st century is to fulfill global energy demand while also reducing detrimental impacts of energy generation and use on the environment. Gasification is a promising technology to meet the requirement of reduced emissions without compromising performance. Coal gasification is not an incinerating process; rather than burning coal completely a partial combustion takes place in the presence of steam and limited amounts of oxygen. In this controlled environment, a chemical reaction takes place to produce a mixture of clean synthetic gas. Gas-solid fluidized bed is one such type of gasification technology. During gasification, the mixing behavior of solid (coal) and gas and their flow patterns can be very complicated to understand. Many attempts have taken place in laboratory scale to understand bed hydrodynamics with spherical particles though in actual applications with coal, the particles are non-spherical. This issue drove the documented attempt presented here to investigate fluidized bed behavior using different ranges of non-spherical particles, as well as spherical. For this investigation, various parameters are controlled that included particle size, bed height, bed diameter and particle shape. Particles ranged from 355 µm to 1180 µm, bed diameter varied from 2 cm to 7 cm, two fluidized beds with diameters of 3.4 cm and 12.4 cm, for the spherical and non-spherical shaped particles that were taken into consideration. Pressure drop was measured with increasing superficial gas velocity. The velocity required in order to start to fluidize the particle is called the minimum fluidization velocity, which is one of the most important parameters to design and optimize within a gas-solid fluidized bed. This minimum fluidization velocity was monitored during investigation while observing variables factors and their effect on this velocity. From our investigation, it has been found that minimum fluidization velocity is independent of bed height for both spherical and non-spherical particles. Further, it decrease with decreasing particle size and decreases with decreasing bed diameter. Shadow sizing, a non-intrusive imaging and diagnostic technology, was also used to visualize flow fields inside fluidized beds for both spherical and non- spherical particles and to detect the particle sizes.

09 BIOMASS FUELS↗

LABORATORY OPTIMIZATION TESTS OF TECHNETIUM DECONTAMINATION OF HANFORD WASTE TREATMENT PLANT LOW ACTIVITY WASTE OFF-GAS CONDENSATE SIMULANT

The Hanford Waste Treatment and Immobilization Plant (WTP) Low Activity Waste (LAW) vitrification facility will generate an aqueous condensate recycle stream (LAW Off-Gas Condensate) from the off-gas system. The baseline plan for disposition of this stream is to send it to the WTP Pretreatment Facility, where it will be blended with LAW, concentrated by evaporation and recycled to the LAW vitrification facility again. Alternate disposition of this stream would eliminate recycling of problematic components, and would enable de-coupled operation of the LAW melter and the Pretreatment Facilities. Eliminating this stream from recycling within WTP would also decrease the LAW vitrification mission duration and quantity of glass waste. This LAW Off-Gas Condensate stream contains components that are volatile at melter temperatures and are problematic for the glass waste form. Because this stream recycles within WTP, these components accumulate in the Condensate stream, exacerbating their impact on the number of LAW glass containers that must be produced. Approximately 32% of the sodium in Supplemental LAW comes from glass formers used to make the extra glass to dilute the halides to acceptable concentrations in the LAW glass, and diverting the stream reduces the halides in the recycled Condensate and is a key outcome of this work. Additionally, under possible scenarios where the LAW vitrification facility commences operation prior to the WTP Pretreatment facility, identifying a disposition path becomes vitally important. This task examines the potential treatment of this stream to remove radionuclides and subsequently disposition the decontaminated stream elsewhere, such as the Effluent Treatment Facility (ETF), for example. The treatment process envisioned is very similar to that used for the Actinide Removal Process (ARP) that has been operating for years at the Savannah River Site (SRS), and focuses on using mature radionuclide removal technologies that are also compatible with longterm tank storage and immobilization methods. For this new application, testing is needed to demonstrate acceptable treatment sorbents and precipitating agents and measure decontamination factors for additional radionuclides in this unique waste stream. The origin of this LAW Off-Gas Condensate stream will be the liquids from the Submerged Bed Scrubber (SBS) and the Wet Electrostatic Precipitator (WESP) from the LAW melter off-gas system. The stream is expected to be a dilute salt solution with near neutral pH, and will likely contain some insoluble solids from melter carryover. The soluble components are expected to be mostly sodium and ammonium salts of nitrate, chloride, and fluoride. This stream has not been generated yet and will not be available until the WTP begins operation, but a simulant has been produced based on models, calculations, and comparison with pilot-scale tests. One of the radionuclides that is volatile and expected to be in greatest abundance in this LAW Off-Gas Condensate stream is Technetium-99 ({sup 99}Tc). Technetium will not be removed from the aqueous waste in the Hanford WTP, and will primarily end up immobilized in the LAW glass by repeated recycle of the off-gas condensate into the LAW melter. Other radionuclides that are low but are also expected to be in measurable concentration in the LAW Off-Gas Condensate are {sup 129}I, {sup 90}Sr, {sup 137}Cs, {sup 241}Pu, and {sup 241}Am. These are present due to their partial volatility and some entrainment in the off-gas system. This report discusses results of optimized {sup 99}Tc decontamination testing of the simulant. Testing examined use of inorganic reducing agents for {sup 99}Tc. Testing focused on minimizing the quantity of sorbents/reactants added, and minimizing mixing time to reach the decontamination targets in this simulant formulation. Stannous chloride and ferrous sulfate were tested as reducing agents to determine the minimum needed to convert soluble pertechnetate to the insoluble technetium dioxide. The reducing agents were tried with and without sorbents. The sorbents, hydroxyapatite and sodium oxalate, were expected to sorb the precipitated technetium dioxide and facilitate removal. The Phase 1 tests examined a broad range of conditions and used the initial baseline simulant. The Phase 2 tests narrowed the conditions based on Phase 1 results, and used a slightly modified simulant. Test results indicate that excellent removal of {sup 99}Tc was achieved using SnCl{sub 2} as a reductant, and was effective with or without sorption onto hydroxyapatite. This reaction worked even in the presence of air (which could oxidize the stannous ion) and at room temperature. This process was very effective at neutral pH, with a Decontamination Factor (DF) >199 in one hour with only 1 g/L of SnCl{sub 2}. Prior work had shown that it was much less effective at alkaline pH. The only deleterious effect observed was that the chromium co-precipitates with the {sup 99}c during the SnCl{sub 2} reduction. This effect was anticipated, and would have to be considered when managing disposition paths of this stream. Reduction using FeSO{sub 4} was not effective at removing {sup 99}Tc, but did remove the Cr. Chromium is present due to partial volatility and entrainment in the off-gas, and is highly oxidizing, so would be expected to react with reducing agents more quickly than pertechnetate. Testing showed that sufficient reducing agent must be added to completely reduce the chromium before the technetium is reduced and removed. Other radionuclides are also present in this off-gas condensate stream. To enable sending this stream to the Hanford ETF, and thereby divert it from the recycle where it impacts the LAW glass volume, several of these also need to be removed. Samples from optimized conditions were also measured for actinide removal in order to examine the effect of the Tc-removal process on the actinides. Plutonium was also removed by the SnCl{sub 2} precipitation process. Results of this separation testing indicate that sorption/precipitation is a viable concept and has the potential to decontaminate the {sup 99}Tc from the stream, allowing it to be diverted away from WTP and thus eliminating the impact of the recycled halides and sulfate on the LAW glass volume. Based on the results, a possible treatment scenario could involve the use of a reductive precipitation agent (SnCl{sub 2}) with or without sorbent at neutral pH to remove the Tc. Although hydroxyapatite was not necessary to effect the {sup 99}Tc removal, it may be beneficial in solid-liquid separations. Other testing will examine removal of the other radionuclides. This testing was the second phase of testing, which aimed at optimizing the process by examining the minimum amount of reductant needed and the minimum reaction time. Although results indicated that SnCl{sub 2} was effective, further work on a pH-adjusted Fe(SO{sub 4}) mixture are needed. Additional tasks are needed to examine removal of the other radionuclides, solid-liquid separation technologies, slurry rheology measurements, composition variability impacts, corrosion and erosion, and slurry storage and immobilization.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗