Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “measures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Comparison of Feynman Variance-To-Mean Measurements Using Measured and Simulated Data

Measured and simulated list-mode data from the NPOD detector system were compared for subcritical systems. Five BeRP ball configurations reflected by polyethylene are investigated in this work. The simulated data were calculated using the MCNP multiplication patch developed at LANL. In addition to comparing the moments of the counting distributions, a full analysis was conducted to infer the multiplication of each system using both the Hansen-Dowdy and Hage-Cifarelli formulisms. Several of the parameters that are input into these methods were also varied to determine their affect on the system multiplication. The main parameters investigated included the system source strength, reflector transmission, and the average number of neutrons released per 239 Pu fission ($\nu$). It is shown that when comparing the measured and simulated data while using the same method and parameters the inferred multiplication values agree within 5%. The measured and simulated multiplication values differ more as the reflector thickness increases. The moments for the simulated data were higher than the measured data for all of the configurations and also disagreed more as the reflector thickness increased. The analysis method and parameters used can lead to a large spread of inferred multiplication values. In the future more configurations will be analyzed in a similar manner and a detailed uncertainty analysis will be performed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement Quality Objective Considerations for Residual Alpha Surface Radioactivity Measurements at Remediation Sites - 16522

Surveys for residual alpha surface radioactivity on materials, equipment, and other non-porous surfaces are most-commonly performed using the traditional 'best available' equipment. The best available equipment for measuring alpha surface radioactivity includes portable gas-flow proportional or scintillation detectors with active surface areas typically ranging from 50 to 800 square centimeters (cm{sup 2}). The measurement equipment is offered by numerous service providers and instrument vendors applying basic detection principles that date back to the early-Atomic Age. The detector face is held as close to the surface as possible and scanned at a typical rate of 2 to 5 centimeters per second (cm/s). Any audible or visual indication of elevated alpha activity would result in a more careful assessment of the possible 'hot spot'. Modern surface contamination surveys continue to employ these best available technologies while endeavoring to achieve ever more restrictive measurement quality objectives and screening or release criteria. This paper considers the possibly unforeseen consequences to sensitivity and precision as scanning speeds are reduced to meet constraining measurement quality objectives. Sensitivity calculations are conducted to demonstrate how application of real-world efficiencies and the most common survey approaches are inadequate to meet sensitivity objectives based on American National Standard N13.12-2013, Surface and Volume Radioactivity Standards for Clearance screening criteria. Alternate data collection and assessment methodologies are offered to enhance the defensibility of collected data with stakeholders. Limitations of available or applied alpha survey technologies should be considered when establishing survey programs at project sites where alpha-emitting radionuclides are expected to contribute to residual surface radioactivity. These include but are not limited to nuclear fuel-cycle sites, military/weapons/energy research and production facilities, and 19.-20. Century-era commercial/ industrial/research/medical facilities where radioactive materials were handled. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Oscillatory motion based measurement method and sensor for measuring wall shear stress due to fluid flow

A shear stress sensor for measuring fluid wall shear stress on a test surface is provided. The wall shear stress sensor is comprised of an active sensing surface and a sensor body. An elastic mechanism mounted between the active sensing surface and the sensor body allows movement between the active sensing surface and the sensor body. A driving mechanism forces the shear stress sensor to oscillate. A measuring mechanism measures displacement of the active sensing surface relative to the sensor body. The sensor may be operated under periodic excitation where changes in the nature of the fluid properties or the fluid flow over the sensor measurably changes the amplitude or phase of the motion of the active sensing surface, or changes the force and power required from a control system in order to maintain constant motion. The device may be operated under non-periodic excitation where changes in the nature of the fluid properties or the fluid flow over the sensor change the transient motion of the active sensor surface or change the force and power required from a control system to maintain a specified transient motion of the active sensor surface.

47 OTHER INSTRUMENTATION↗

Advancing Building Air Leakage Measurement and Modeling: Measurement of Interior Air Leaks, Experimental Comparison to Conventional Methods, and Building Modeling Characteristics

This report, Advancing Building Air Leakage Measurement and Modeling: Measurement of Interior Air Leaks, Experimental Comparison to Conventional Methods, and Building Modeling Characteristics, developed two new building air leakage measurement methods, experimentally evaluated the performance in comparison to conventional methods, experimentally evaluated the behavior of leaks for specific crack structures, and identified testing constraints and model implications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Concomitant ion effects on isotope ratio measurements with liquid sampling – atmospheric pressure glow discharge ion source Orbitrap mass spectrometry

RATIONALE: The field of highly accurate and precise isotope ratio (IR) analysis has been dominated by inductively coupled plasma and thermal ionization mass spectrometers. While these instruments are considered the gold standard for IR analysis, the International Atomic Energy Agency desires a field deployable instrument capable of accurately and precisely measuring U isotope ratios. METHODS: The proposed system interfaces the liquid sampling – atmospheric pressure glow discharge (LS-APGD) ion source with a high resolution Exactive Orbitrap mass spectrometer. With this experimental setup certified U isotope standards and unknown samples were analyzed. The accuracy and precision of the system were then determined. RESULTS: The LS-APGD /Exactive instrument measures a certified reference material of natural U (235U/238U = 0.007258) as 0.007041 with a relative standard deviation of 0.158% meeting the International Target Values for Uncertainty for the destructive analysis of U. Additionally, when three unknowns measured and compared to the results from an ICP multi collector instrument, there is no statistical difference between the two instruments. CONCLUSIONS: The LS-APGD / Orbitrap system, while still in the preliminary stages of development, offers highly accurate and precise IR analysis that suggest a paradigm shift in the world of IR analysis. Furthermore, the portability of the LS-APGD as an elemental ion source combined with the low overhead and small size of the Orbitrap suggest that the instrumentation is capable of being field deployable. With liquid sampling glow discharge-Orbitrap MS, isotope ratio and precision performance improves with rejection of concomitant ion species.

atmospheric pressure sampling↗

Note: A sample holder design for sensitive magnetic measurements at high temperatures in a magnetic properties measurement system

A sample holder design for high temperature measurements in a commercial MPMS SQUID magnetometer from Quantum Design is presented. It fulfills the requirements for the simultaneous use of the oven and reciprocating sample option (RSO) options, thus allowing sensitive magnetic measurements up to 800 K. Alternating current susceptibility can also be measured, since the holder does not induce any phase shift relative to the ac driven field. It is easily fabricated by twisting Constantan Copyright-Sign wires into a braid nesting the sample inside. This design ensures that the sample be placed tightly into a tough holder with its orientation fixed, and prevents any sample displacement during the fast movements of the RSO transport, up to high temperatures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Combined x-ray scattering, radiography, and velocity interferometry/streaked optical pyrometry measurements of warm dense carbon using a novel technique of shock-and-release

This work focused on a new application of the shock-and-release technique for equation of state (EOS) measurements. Warm dense matter states at near normal solid density and at temperatures close to 10 eV in diamond and graphite samples were created using a deep release from a laser-driven shock at the OMEGA laser facility. Independent temperature, density, and pressure measurements that do not depend on any theoretical models or simulations were obtained using imaging x-ray Thomson scattering, radiography, velocity interferometry, and streaked optical pyrometry. The experimental results were reproduced by the 2-D FLASH radiation hydrodynamics simulations finding a good agreement. The final EOS measurement was then compared with widely used SESAME EOS models as well as quantum molecular dynamics simulation results for carbon, which were very consistent with the experimental data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thomson scattering measurements from asymmetric interpenetrating plasma flows

Imaging Thomson scattering measurements of collective ion-acoustic fluctuations have been utilized to determine ion temperature and density from laser produced counter-streaming asymmetric flows. Two foils are heated with 8 laser beams each, 500 J per beam, at the Omega Laser facility. Measurements are made 4 mm from the foil surface using a 60 J 2ω probe laser with a 200 ps pulse length. Measuring the electron density and temperature from the electron-plasma fluctuations constrains the fit of the multi-ion species, asymmetric flows theoretical form factor for the ion feature such that the ion temperatures, ion densities, and flow velocities for each plasma flow are determined.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison Measurements of Silicon Carbide Temperature Monitors

As part of the efforts initiated through the Advanced Test Reactor (ATR) National Scientific User Facility (NSUF) program to make Silicon Carbide (SiC) temperature monitors available, a capability was developed at the Idaho National Laboratory (INL) to complete post-irradiation evaluations of these monitors. INL selected the resistance measurement approach for detecting peak irradiation temperature from SiC temperature monitors. To demonstrate this new capability, comparison measurements were completed by INL and Oak Ridge National Laboratory (ORNL) on identical samples subjected to identical irradiation conditions. Results reported in this paper indicate that the resistance measurement approach can yield similar peak irradiation temperatures if appropriate equipment is used and appropriate procedures are followed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Oxygen Reduction Reaction Measurements on Platinum Electrocatalysts Utilizing Rotating Disk Electrode Technique: I. Impact of Impurities, Measurement Protocols and Applied Corrections

The rotating disk electrode (RDE) technique is being extensively used as a screening tool to estimate the activity of novel PEMFC electrocatalysts synthesized in lab-scale (mg) quantities. Discrepancies in measured activity attributable to glassware and electrolyte impurity levels, as well as conditioning, protocols and corrections are prevalent in the literature. Moreover, the electrochemical response to a broad spectrum of commercially sourced perchloric acid and the effect of acid molarity on impurity levels and solution resistance were also assessed. Our findings reveal that an area specific activity (SA) exceeding 2.0 mA/cm 2 (20 mV/s, 25°C, 100 kPa, 0.1 M HClO 4 ) for polished poly-Pt is an indicator of impurity levels that do not impede the accurate measurement of the ORR activity of Pt based catalysts. After exploring various conditioning protocols to approach maximum utilization of the electrochemical area (ECA) and peak ORR activity without introducing catalyst degradation, an investigation of measurement protocols for ECA and ORR activity was conducted. Down-selected protocols were based on the criteria of reproducibility, duration of experiments, impurity effects and magnitude of pseudo-capacitive background correction. In sum, statistical reproducibility of ORR activity for poly-Pt and Pt supported on high surface area carbon was demonstrated.

14 SOLAR ENERGY↗

Synchrotron infrared reflectivity measurements of iron at high pressures

The infrared reflectance of iron was studied using high-pressure synchrotron radiation methods up to 50 GPa at room temperature in a diamond anvil cell of 1000-8000 cm{sup -1} (1.25-10 {mu}m). The magnitude of the reflectivity shows a weak pressure dependence up to the transition from the body centered cubic ({alpha}) to hexagonal close packed ({epsilon}) phase transition, where a discontinuous change in both the slope and magnitude of the reflectivity was observed. Reflectance spectra were corrected for diamond absorption and treated with a Kramers-Kronig analysis to extract the optical constants; the emissivity of iron was derived from Kirchoff's law. The pressure and wavelength dependence of the emissivity is characterized by an empirical function for 1.5-1.9 {mu}m; this wavelength range is useful for spectroradiometric temperature measurements from 1000 K up to {approx}2500 K. {alpha}-Fe is a nonideal emitter; however, {epsilon}-Fe behaves as an almost perfect greybody in the infrared up to the highest pressures of the measurements. Temperature measurements based on the spectroradiometry of iron samples should take into account the wavelength dependent emissivity below the {alpha}-{epsilon} phase transition at {approx}13 GPa.

36 MATERIALS SCIENCE↗

Algorithm for Screening Phasor Measurement Unit Data for Power System Events and Categories and Common Characteristics for Events Seen in Phasor Measurement Unit Relative Phase-Angle Differences and Frequency Signals

A network of multiple phasor measurement units (PMU) was created, set up, and maintained at the University of Texas at Austin to obtain actual power system measurements for power system analysis. Power system analysis in this report covers a variety of time ranges, such as short- term analysis for power system disturbances and their effects on power system behavior and long- term power system behavior using modal analysis. The first objective of this report is to screen the PMU data for events. The second objective of the report is to identify and describe common characteristics extracted from power system events as measured by PMUs. The numerical characteristics for each category and how these characteristics are used to create selection rules for the algorithm are also described. Trends in PMU data related to different levels and fluctuations in wind power output are also examined.

17 WIND ENERGY↗

Modeled Martian subsurface elemental composition measurements with the Probing In situ with Neutron and Gamma ray instrument: Gamma and Neutron Measurements on Mars

Here, the Probing In situ with Neutrons and Gamma rays (PING) instrument is an innovative application of active neutron-induced gamma-ray technology. The objective of PING is to measure the elemental composition of the Martian regolith. As part 2 of a two-part submission, this manuscript presents PING's sensitivities as a function of the Martian regolith depth and PING's uncertainties in the measurements as a function of observation time in passive and active mode. Part 1 of our submission models the associated regolith types. The modeled sensitivities show that in PING's active mode, where both a Pulsed Neutron Generator (PNG) and a Gamma-Ray Spectrometer (GRS) are used, PING can interrogate the material below the rover to about 20 cm due to the penetrating nature of the high-energy neutrons and the resulting secondary gamma rays observed with the GRS. PING is capable of identifying most major and minor rock-forming elements, including H, O, Na, Mn, Mg, Al, Si, P, S, Cl, Cr, K, Ca, Ti, Fe and Th. The modeled uncertainties show that PING's use of a PNG reduces the required observation times by an order of magnitude over a passive operating mode where the PNG is turned off. While the active mode allows for more complete elemental inventories with higher sensitivity, the gamma-ray signatures of some elements are strong enough to detect in passive mode. We show that PING can detect changes in key marker elements and make thermal neutron measurements in about 1 minute that are sensitive to H and Cl.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rates of Ligand Exchange around the Bis-Oxalato Complex [NpO 2 (C 2 O 4 ) 2 ] 3- Measured by Using Multinuclear NMR Spectroscopy under Neutral to Semi-Alkaline Conditions [Rates of ligand exchange around the bis-oxalato complex NpO2(C2O4)23- measured using multinuclear NMR at neutral to semi-alkaline conditions]

The kinetics of ligand exchange between the free oxalate ion, C 2 O 4 2- , and the bis-oxalato Np V complex, [NpO 2 (C 2 O 4 ) 2 ] 3- , in aqueous solution are reported by using 13 C and 17 O NMR spectroscopy methods. Rates of exchange were measured in the pH regime of 6.5–9.0, at which speciation is shown to be suitably simple. Because the neptunium(V) complex is paramagnetic, the rates of ligand exchange were estimated by following the width of the 13 C and 17 O signals assigned to the free oxalate ion in solution and by applying the Swift–Connick method for measuring rates of exchange. A set of experiments were conducted in which pH and total oxalate concentration were varied, and the linear dependence of the rate on these parameters was demonstrated. Variable-temperature NMR spectroscopy was also performed to measure activation parameters of complexation. Finally, at pH<8.0, ΔH ≠ =16.9 ±4.9 kJ mol -1 and ΔS≠=-116.3 ±17.1kJ mol -1 K -1 , whereas at pH>8.0 there is almost no dependence on temperature, which is interpreted to indicate that hydrolysis is coupled to ligand exchange under these conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurements of ψ(2S) and X(3872) → J/ψπ + π - production in pp collisions at $\sqrt{s} = 8$ TeV with the ATLAS detector

Differential cross sections are presented for the prompt and non-prompt production of the hidden-charm states X(3872) and ψ(2S), in the decay mode J/ψπ + π – , measured using 11.4 fb –1 of pp collisions at √s = 8 TeV by the ATLAS detector at the LHC. The ratio of cross-sections X(3872)/ψ(2S) is also given, separately for prompt and non-prompt components, as well as the non-prompt fractions of X(3872) and ψ(2S). Assuming independent single effective lifetimes for non-prompt X(3872) and ψ(2S) production gives R B = B(B→X(3872)+any)B(X(3872)→J/ψπ+π–)/B(B→ψ(2S)+any)B(ψ(2S)→J/ψπ+π–)=(3.95±0.32(stat)±0.08(sys))×10 –2 separating short- and long-lived contributions, assuming that the short-lived component is due to B c decays, gives R B = (3.57 ± 0.33(stat) ± 0.11(sys)) × 10 –2 , with the fraction of non-prompt X(3872) produced via B c decays for p T (X(3872)) > 10 GeV being (25 ± 13(stat) ± 2(sys) ± 5(spin))%. The distributions of the dipion invariant mass in the X(3872) and ψ(2S) decays are also measured and compared to theoretical predictions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗