Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “loss reduction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Effects of flight on noise radiated from convected ring sources in coaxial dual flow. Part 2: The noise from heated jets

The effects of flight on noise from heated jets are discussed. The effects of the additionally, extraneously-generated dipole and simple source terms which arise as a result of the density gradients across the fluid interfaces were incorporated. The coaxial flows with inverted profiles are shown to be quieter than the conventional profiles; however, the benefit of noise reduction at higher outer-to-inner area ratios is totally offset as the inverted profile incurs a significant massloss and thrust-loss. Amongst all the possible coaxial configurations when on of the coaxial streams is heated-conventional profile (CP), inverted profile (IP) and the variable stream control engine (VSCE) cycle-and at constant massflow and thrust, a VSCE-cycle is the most desirable and the best possible engine cycle inasmuch as it provides over more than 18.0 dB reduction in SPL (as compared against noise from a CP-cycle) at all angles, both statically and in flight, for area ratios Sigma 0.25.

Dash, R.↗

Changes in SSL Device Efficiency and Optical Performance Under Accelerated Aging Conditions

Lighting application efficiency (LAE) describes the efficient delivery of light from the light source to the lighted task and is viewed as a new frontier—increasing energy savings with solid-state lighting (SSL) technologies. The framework for LAE that is proposed by the U.S. Department of Energy (DOE) consists of four major elements: light source efficiency, optical delivery efficiency, spectral efficiency, and intensity effectiveness. This report focuses on a sampling of the available SSL products that can be broadly defined as having modified spectral output because the method of spectra modification has a significant impact on light source efficiency and long-term optical delivery and spectral efficiencies. This report focused on the changes in light source, optical delivery, and spectral efficiencies that occur during aging of SSL devices. An accelerated stress test (AST) regiment was developed for the devices under test (DUTs) examined in this report to provide insights into how the performance of SSL devices change with aging. The AST protocols demonstrate that the SSL products discussed in this report often reduce light source efficiency to achieve different spectral characteristics. In addition, aging of the optical components (e.g., lenses, solder masks) in SSL devices can produce increased light absorption, which negatively impacts optical delivery efficiency and light source efficiency. The modified spectral outputs of the selected SSL products discussed in this report come in a variety of form factors and achieve enhanced optical performance by using a variety of methods. All of the products examined in this study use mid-power light-emitting diodes (MP-LEDs), although the number, configuration, phosphor content, and light-emitting diode (LED) pump of the MP-LEDs differ. Product MS-1 is a 60-watt (W) replacement A19 lamp with a hermetically sealed glass globe, which contains an embedded optical filter to absorb green and yellow emissions, thereby creating a “sunlike” modified spectrum. Product MS-2 is a 60-W replacement A19 lamp with 30 MP-LEDs, and it uses a violet LED pump, along with green and red phosphor emissions, to produce a “healthy” spectrum. This spectrum omits blue emissions in an effort to reduce melanopic lux. Product MS-3 is an LED module consisting of 21 MP-LEDs that use a violet LED pump, along with blue, green, and red phosphors, to produce a “sunlike” spectrum. Products MS-4 and MS-5 are both 6-inch (in) downlights that use a manual switching mechanism so that users can select application-specific correlated color temperatures before installation. Products MS-4 and MS-5 both contain two LED primaries (2,700 Kelvin [K] and 5,000 K) for spectral tuning. Product MS-4 contains 12 MP-LEDs for each LED primary, and Product MS-5 contains 10 MP-LEDs for each LED primary. This report summarizes the overall findings from up to 8,000 hours (hrs) of AST on the lamp DUTs (Products MS-1 and MS-2); up to 5,000 hrs of AST on the LED light engine DUTs (Product MS-3); and up to 7,000 hrs of AST on the downlight DUTs (Products MS-4 and MS-5). The AST procedures used in this study included a room temperature operational life (RTOL) test, an operational life test conducted at 45 degrees Celsius (°C; 45OL) test, an operational life test conducted at 75°C (75OL), a wet high-temperature operational life test performed at 65°C and 90% relative humidity (6590), and a wet high-temperature operational life test performed at 75°C and 75% relative humidity (7575). The AST procedures used for Products MS-1 and MS-2 were RTOL, 45OL, and 6590. The AST procedures used for Products MS-3, MS-4, and MS-5 were RTOL, 75OL, and 7575. During the ASTs described herein, separate populations of each product (three DUTs in each population for Products MS-1, MS-2, MS-4, and MS-5; four DUTs in each population for Product MS-3) were subjected to power cycling of 1 hr on and 1 hr off. The key findings from this study include the following. Enhanced optical performance came at the cost of reduced light source efficiency for the lamps and light engines examined in this study. The optical filter used to produce a “sunlike” spectrum for Product MS-1 reduced light source efficiency by 26%, from 113 lumens per watt (lm/W) to 85 lm/W. Products MS-2 and MS-3 that used a violet-pumped LED to achieve “healthy” and “sunlike” enhanced optical performance, respectively, suffered the largest reduction in initial light source efficiency (49 lm/W for Product MS-2 and 68 lm/W for Products MS-3) perhaps because of the use of violet LED as the optical pump. Product MS-2 also had the poorest color fidelity because of undersaturation of blues and oversaturation of greens and yellows. Chromaticity maintenance of the products in this study was generally good, with parametric failure only occurring for one product at one AST condition (i.e., Product MS-3 at 7575). The chromaticity shift for Product MS-3 in 7575 test conditions resulted from reduced emissions of the broad green and red phosphors used to mimic sunlight in the 500–750 nanometer (nm) range. As a result of these phosphor emission losses, chromaticity shifted toward the more stable violet-pumped LED and blue phosphor. Although chromaticity maintenance was acceptable for most products tested, different chromaticity shift mechanisms were observed for temperature and humidity tests compared with temperature alone for Products MS-1, MS-2, and MS-3. For Product MS-1, a relative increase in green emissions was observed with humidity, which may indicate humidity-accelerated degradation of the optical filter at green wavelengths (optical delivery efficiency reduction) or degradation of the emitters in the red region (spectral efficiency reduction). The violet-pumped products (i.e., MS-2 and MS-3) exhibited different chromaticity shift behavior in the temperature-humidity environments, with Product MS-2 shifting generally yellow because of photo-induced oxidation of the plastic globe (i.e., a reduction of optical delivery efficiency) and Product MS-3 shifting toward violet and blue emitters because of faster loss of emission from green and red phosphors (i.e., a reduction in spectral efficiency). Because of an initial drop in power consumption, the light source efficiency of downlights (Products MS-4 and MS-5) increased at RTOL throughout the test duration. The light source efficiency initially increased during 75OL until a decay in luminous flux maintenance (LFM) dominated light source efficiency, whereas the light source efficiency decreased for the entire 7575 test duration. It was found that increasing the ambient environment of an SSL device from 25°C to 75°C decreases the LFM by 2.7 to 5.5, depending on design of the SSL device. Adding humidity to the system (75OL to 7575) was found to decrease LFM by another factor of approximately 3.0. A common location of failure was identified for the downlights (Products MS-4 and MS-5) operated in the 7575 environment. This failure abruptly occurred between 3,000 to 5,000 hrs of testing on the film capacitor of the electromagnetic interference (EMI) filter near the diode bridge for 11 of the 12 downlights. It is likely that this failure was caused by a combination of the high electrical voltage across the capacitor, the location of the capacitor near the heat sources (e.g., transformers, diode bridges, power resistors), and the high stress environment of 7575. Longer test times are needed to fully understand the LFM, luminous efficacy changes, and chromaticity shifts for some of the products. Because of the high reliability, light source efficiency, and spectral tuning capabilities of LEDs, the expectations of LAE for SSL products are greatly increased over traditional lighting products. The data gathered in this report begin to provide an understanding of the tradeoffs that current SSL products undergo when optimizing the different efficiency elements of LAE. As discussed in this report, the findings from the tests conducted show that the optimization of spectral efficiency can come at the cost of initial light source efficiency. Furthermore, the introduction of violet LEDs can promote long-term optical delivery efficiency degradation, and the introduction of optical filters or new phosphors can lead to unwanted spectral efficiency changes because the ratio of phosphor emitters changes with aging. The data presented in this report also identified a common failure location in 6-in downlights. The results regarding long-term behavior of the modified spectra devices studied provide valuable information about changes to the light source, spectral, and optical delivery efficiencies as the devices age. This information can be used to improve future SSL designs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Demonstration of a fault impact reduction control module for wind turbines

Abstract. Traditionally, wind turbines in distributed applications make control decisions as isolated systems. They generally provide maximum power output during operation and manage internal faults with little consideration of the rest of the power system. Although fault detection and tolerance schemes are widely researched and implemented, controls to ameliorate such faults are uncommon in research and industry. The rapid shutdown of a wind turbine in a large transmission-connected wind plant will have a minimal impact on a large power system, but in a microgrid or isolated grid context the abrupt loss of a single wind turbine may cause grid instability and high stress on the system. This paper demonstrates a fault impact reduction control (FIRC) module for a wind turbine, which implements wider warning thresholds around fault thresholds. When the turbine crosses a warning threshold, the controller sends its predicted action to the grid controller, which facilitates the grid operator’s response to a potential wind turbine fault and then takes appropriate action to ameliorate the fault. Various test cases demonstrate the controller action under a variety of faults, and various scenarios demonstrate the grid benefit of an FIRC in both microgrid- and grid-connected contexts. The FIRC maximizes wind turbine generation and eases generation transition under a variety of fault scenarios. The FIRC module is easy to integrate with most existing controllers, just requiring derate capability, and can be easily modified to include the various warnings and thresholds that the user desires. This analysis is mainly performed in a MATLAB-Simulink-based research wind turbine model and is also implemented in the existing LabVIEW-based controller of the same research turbine at NREL.

17 WIND ENERGY↗

Extravehicular Activity on the Lunar Surface: Mapping Mitigation Risk Consequence for Crew Needing Assistance or Rescue

Extravehicular activity (EVA) on the lunar surface presents unique risks to crew with possibility for injury. Without appropriate assistance or rescue capability, inability to nominally ambulate and return to a lander, especially during early Artemis missions, could have catastrophic consequences. Mapping likelihood and consequence safety risk associated with identified injury scenarios establishes a baseline from which to assess potential mitigation solutions to ensure crew health and safety. Causes leading to the need for incapacitated crew rescue (ICR) during EVA on the lunar surface were previously identified and classified using an ICR/Acute Injury scenario spectrum. Severe scenarios are those when the affected astronaut requires either partial or full continuous assistance from the rescuer. Evaluation of these continual reliance conditions included calculating event probabilities (likelihoods) associated with an early Artemis mission and mapping them to established Exploration System Directorate (ESD) probability thresholds; safety consequences were analyzed and correlated to defined ESD personnel safety categories. These resulting likelihood and consequence values served as a baseline for assessing risk reduction of three mitigation capabilities: crew assistance (rescuer crew) only, walking assist devices, and a wheeled transport device. Of the twenty-five continual reliance conditions, ten were evaluated as “catastrophic” (Level 5, loss of life) during EVA on the lunar surface with probabilities ranging from moderate to very low during an early Artemis mission. Crew assistance only and walking assist devices showed similar potential for risk reduction, with four of the ten causes decreasing to Level 4. A wheeled transport device further increased risk reduction with six of the ten conditions decreasing to Level 4. Given the catastrophic consequence of several identified conditions, assessments should be performed to determine the feasibility of mitigation capabilities. It is currently unknown whether a rescuer astronaut could effectively provide continuous assistance to enable both crew to return safely to the lander from the standpoint of both suit geometry and human performance. Although resulting in an increase in resources, providing a wheeled transport provides the highest risk reduction potential, and walking assist devices may have prevention as well as mitigation benefits.

lunar surface↗

Effect on head-wind profiles and mean head-wind velocity on landing capacity flying constant-airspeed and constant-groundspeed approaches

A study was conducted to determine the effect of head-wind profiles and mean head-wind velocities on runway landing capacity for airplanes flying constant-airspeed and constant-groundspeed approaches. It was determined that when the wind profiles were encountered with the currently used constant airspeed approach method, the landing capacity was reduced. The severity of these reductions increased as the mean head-wind value of the profile increased. When constant-groundspeed approaches were made in the same wind profiles, there were no losses in landing capacity. In an analysis of mean head winds, it was determined that in a mean head wind of 35 knots, the landing capacity using constant-airspeed approaches was 13% less than for the no wind condition. There were no reductions in landing capacity with constant-groundspeed approaches for mean head winds less than 35 knots. This same result was observed when the separation intervals between airplanes was reduced.

Hastings, E. C., Jr.↗

Discrepant wear behavior of carbon nanotubes (CNTs) and dispersant in four-ball unidirectional and ball-on-flat reciprocating sliding tests

Carbon nanotubes (CNTs), basically rolled graphene sheets, have been studied lately as oil additives in the literature. However, we observed discrepant impact of CNTs on wear protection from two common tribological tests, four-ball unidirectional sliding and high frequency reciprocating rig (HFRR) ball-on-flat reciprocating sliding. To gain a stable suspension and dispersion of the CNTs in the oil, the CNT surface was functionalized with a phenyl ligand and a dispersant, polyisobutylene succinimide (PIBSI), was added. In the four-ball test, PIBSI alone failed to protect the surface but the CNTs effectively reduced the wear loss. The observations in the HFRR test however were the opposite: the PIBSI alone provided strong wear reduction but the CNTs had no positive impact. Here, such a discrepancy was hypothetically attributed to the different wear protection mechanisms by the PIBSI and CNTs which responded distinctively under different testing conditions. Additional unidirectional and reciprocating sliding tests with matching Hertzian contact pressures were able to validate the hypothesis. Worn surface morphological examination and tribofilm chemical analysis further supported the proposed wear mechanisms. Fundamental understanding gained in this study provides insights into the potential benefits and limitations of using CNTs in lubrication.

36 MATERIALS SCIENCE↗

Analysis of the Fe 2p XPS for hematite α Fe2O3: Consequences of covalent bonding and orbital splittings on multiplet splittings

The origins of the complex Fe 2p X-Ray Photoelectron Spectra (XPS) of hematite (α-Fe2O3) are analyzed and related to the character of the bonding in this compound. This analysis provides a new and novel view of the reasons for XPS binding energies (BEs) and BE shifts, which deepens the current understanding and interpretation of the physical and chemical significance of the XPS. In particular, many-body effects are considered for the initial and the final, 2p-hole configuration wavefunctions. It is shown that a one-body or one-configuration analysis is not sufficient and that the many-body, many-determinantal, and many-configurational character of the wavefunctions must be taken into account to describe and understand why the XPS intensity is spread over an extremely large number of final 2p-hole multiplets. The focus is on the consequences of angular momentum coupling of the core and valence open shell electrons, the ligand field splittings of the valence shell orbitals, and the degree of covalent mixing of the Fe(3d) electrons with the O(2p) electrons. Novel theoretical methods are used to estimate the importance of these various terms. An important consequence of covalency is a reduction in the energy separation of the multiplets. Although shake satellites are not considered explicitly, the total losses of intensity from the angular momentum multiplets to shake satellites is determined and related to the covalent character of the Fe-O interaction. The losses are found to be the same for Fe 2p1/2 and 2p3/2 ionization.

Bagus, Paul S. (ORCID:0000000349315217)↗

Severe declines in hydraulic capacity and associated carbon starvation drive mortality in seawater exposed Sitka-spruce (Picea sitchensis) trees

Abstract Sea-level rise is causing widespread tree mortality of coastal forests, with large consequences on the Earth system as a result of these forests’ importance in carbon and nutrient export. The mechanisms of mortality under these conditions are, however, poorly tested. We used wood anatomy traits, wood δ 13 C, and tree radial growth to retrospectively assess the physiological process of seawater effects on whole tree xylem hydraulic capacity, gas exchange, and radial growth. During the latter stages of mortality (2018–2019), we directly measured metrics of water use and carbon metabolism across trees having crowns ranging from fully foliated to completely defoliated to investigate mortality processes at the sub-annual scale. Upon seawater exposure, soil salinity increased and allocation to hydraulic function declined, resulting in a dramatic reduction in water supply to the crown, increased crown-level water stress, and subsequent crown foliage loss. Simultaneously, leaf-level photosynthetic capacity declined steeply with increasing salinity. The combined loss of crown foliage area and photosynthetic rates per unit leaf area promoted carbon starvation, while no evidence of hydraulic failure was observed. These results elucidate mechanisms of coastal forest death under seawater exposure, enabling more accurate modeling in the future.

54 ENVIRONMENTAL SCIENCES↗

High Performance SrFe 0.2 Co 0.4 Mo 0.4 O 3–δ Ceramic Anode Supported Low-Temperature SOFCs

The development of alternative ceramic anodes for low-temperature solid oxide fuel cells (LT-SOFCs) is essential to overcome the inherent challenges such as redox instability and coking associated with Ni-based cermet anodes. Moreover, due to the large electrolyte ohmic loss at low temperature, it is critical to developing an electrode supported cell that allows electrolyte thickness reduction. Here we successfully demonstrated a high performance SrFe 0.2 Co 0.4 Mo 0.4 O 3–δ (SFCM) ceramic anode supported LT-SOFC with a peak power density of 730 mW cm –2 and 300 mW cm –2 at ambitious low temperatures of 550 °C and 450 °C, respectively, in humidified H 2 . The new anode material SFCM exhibits exceptional conductivity of over 30 S cm –1 at 450 °C in humidified H 2 , providing essential current collection capability as an anode backbone appropriate for the infiltration of Ni-gadolinia doped ceria (GDC) electrocatalysts. Compared to conventional Ni-cermet anodes, the nano-sized Ni-GDC particles in our SFCM based electrode significantly improves the cell stability in hydrocarbon gases. We demonstrated a stable long-term operation over a period of 380 h in CH 4 –containing gas mixtures at 450 °C with a voltage degradation rate of 4% per 1000 h at a constant current of 0.2 A*cm –2 . Furthermore, our results demonstrate a high performance ceramic anode with high stability for low temperature operation.

25 ENERGY STORAGE↗

Cooperative Research and Development Agreement between National Energy Technology Laboratory and The Pennsylvania State University (Final Report)

This project will use bipolar membranes to produce efficient vapor-phase electrolysis cells for splitting CO 2 to CO and oxygen. CO is a valuable chemical feedstock that can be combined catalytically with hydrogen in the Fischer-Tropsch process to make liquid fuels. CO is arguably the best target for CO 2 reduction since, as a gaseous product, it is easily collected and is relatively immune to membrane crossover losses. The keys to success in this project are to design and synthesize hydrophilic, low resistance bipolar membranes and to create optimized electrode/catalyst/electrolyte architectures based on these new membranes and advanced catalysts in order to achieve high current density at low overpotentials for CO 2 conversion. High current density is key to achieving industrially relevant throughput for the process and low overpotentials maintain high overall efficiency for the process.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Phase Field Modeling of Corrosion for Design of Next-Generation Magnesium-Aluminum Vehicle Joints

In this study, WPI and its partners sought to understand galvanic corrosion in Mg-Al friction stir weld (FSW) joints. Unlike fusion welds, FSW is done in the solid state. This limits (but does not eliminate) the formation of brittle Al-Mg intermetallics, resulting in better joint strength and corrosion resistance. This study aimed to understand corrosion behavior of Mg-Al FSW joints by using a Cahn-Hilliard phase field electrochemistry model based on the work of Pongsaksawad et al. Its context challenge problem was an ultra-light door designed by Magna with 6061-Al sheet outer and ZEK100-Mg sheet inner panels, joined by an adhesive and FSW. Unlike most FSW joints, which weld through the softer material into the harder one, the Al sheet’s hem joint around Mg required the FSW tool to through the harder Al into the softer Mg, which was itself a challenge. Despite this challenge, PNNL succeeded in consistently making very strong FSW lap joints, by using a triflute tool and power control. Characterization showed mostly separate Al and Mg regions in the weld, usually with a hook protruding from Al into Mg, which likely contributed to high joint strength. Nanohardness mapping showed higher hardness in thin Mg swirls into the Al nugget, likely due to the intermetallics. The study used the industry standard SAE J2334 Cyclic Corrosion Test (CCT) to simulate corrosion conditions over the life of a vehicle, as well as linear polarization testing and ASTM G71 pitting corrosion testing. Corrosion reactions were: H 2 O + ½O 2 + 2e - → 2OH - at the Al cathode, and either Mg → Mg 2+ + 2e - or Mg + 2OH - → Mg(OH) 2 + 2e - at the Mg anode, with electron transfer through the joint. Mass loss increased with Al section length, supporting the hypothesis that galvanic corrosion in Al-Mg joints is limited by the cathodic reaction. Both pitting corrosion (first anode reaction) and hydroxide film formation (second reaction) were observed. The J2334 CCT test method was slightly modified, adding a chromium solution cleaning step after each week of corrosion testing, in order to remove Mg oxides and hydroxides and accurately measure mass loss over time. That said, FSW joints treated in this way did not did not exhibit significant reduction in lap shear strength of the joints vs. newly welded samples which had not undergone corrosion. Corrosion appeared to consist mainly of pitting in Mg in a way which did not directly affect the bond between the materials where the joints failed. A Cahn-Hilliard phase field model coupled with electrical potential described the electronically mediated galvanic corrosion electrochemical reactions described above in the four-component Al-Mg-H 2 O-(H 2 O+½O 2 ) system. This 2-D model successfully predicted Mg(OH)₂ formation at the anode in some circumstances, and Mg pitting corrosion in others, and showed the correct electric field directions in both cases. The model predicted Mg pit corrosion depth within a factor of two of measured pits.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Blueprints for Training Information Bottlenecks for Collider Analyses

Dimensionality reduction is a crucial aspect of data analysis in high energy physics, even if accompanied by information loss. Several methods, including histogram- and kernel-based analyses, are only computationally feasible for low-dimensional data. Furthermore, simulation models used in HEP can often only be validated for low-dimensional data. We provide several blueprints for using machine learning to create low-dimensional data representations (continuous event variables and discrete classification labels) for use in signal discovery and parameter estimation tasks. We also describe how to design the learned representation to facilitate a) searches with unknown model parameters and b) validation of simulation models in data control regions.

43 PARTICLE ACCELERATORS↗

Removal of Iron from Pyrite-Rich Coal Refuse by Calcination and Magnetic Separation for Hydrometallurgical Extraction of Rare Earth Elements

In the metallurgical extraction of rare earth elements (REEs), the ratio of contaminant ions to REEs in the leachate dictates the cost and operational efficiency of the downstream processes. The current study investigated the potential iron contamination removal from the feed to the hydrometallurgical process by calcination followed by magnetic separation. The 2.20 specific gravity sink fraction of Baker coal seam coarse refuse was pulverized to finer than 180 μm, calcined at various temperatures, and separated into magnetic and non-magnetic fractions using a wet high-intensity magnetic separator at different field strengths. The untreated feed, calcined products, and their subsequent magnetic and non-magnetic fractions were subjected to acid leaching tests with 1.2 M sulfuric acid at 75 °C and 1% w/v solids concentration. The recovery of light and heavy rare earth elements (LREEs and HREEs, respectively) along with the concentration of common contaminant ions (Al, Ca, and Fe) were measured as output variables. The weight percent of magnetic material was maximized at approximately 29% by calcination at a temperature of 400 °C. Magnetic removal of this fraction using a field strength of 1.15 Tesla resulted in the rejection of 81% of the iron. Leaching of the magnetic fraction provided significantly higher Fe recovery relative to untreated feed material and the non-magnetic fraction. The non-magnetic fraction was subsequently calcined at 600 °C to dehydroxylate the clays and released the REE minerals in the same manner as the treatment of the original coarse refuse material. A comparison of the leachate elemental concentrations resulting from the leaching of both the calcined non-magnetic and original coarse refuse showed only a slight reduction in the iron content from the non-magnetic material. This finding combined with the REE loss in the magnetic fraction resulted in the conclusion that the magnetic removal step was unfavorable.

58 GEOSCIENCES↗

Chemical kinetic performance losses for a hydrogen laser thermal thruster

Projected requirements for efficient, economical, orbit-raising propulsion systems have generated investigations into several potentially high specific impulse, moderate thrust, advanced systems. One of these systems, laser thermal propulsion, utilizes a high temperature plasma as the enthalpy source. The plasma is sustained by a focused laser beam which maintains the plasma temperature at levels near 20,000 K. Since such temperature levels lead to total dissociation and high ionization, the plasma thruster system potentially has a high specific impulse decrement due to recombination losses. The nozzle flow is expected to be sufficiently nonequilibrium to warrant concern over the achievable specific impluse. This investigation was an attempt at evaluation of those losses. The One-Dimensional Kinetics (ODK) option of the Two-Dimensional Kinetics (TDK) Computer Program was used with a chemical kinetics rate set obtained from available literature to determine the chemical kinetic energy losses for typical plasma thruster conditions. The rates were varied about the nominal accepted values to band the possible losses. Kinetic losses were shown to be highly significant for a laser thermal thruster using hydrogen. A 30 percent reduction in specific impulse is possible simply due to the inability to completely extract the molecular recombination energy.

Mccay, T. D.↗

Role of chemotaxis in the ecology of denitrifiers

It has been recognized that the process of denitrification represents a major sequence in the nitrogen cycle. It involves the anaerobic reduction of nitrate or nitrite to nitrous oxide or elemental nitrogen. This process is responsible for significant losses of nitrogen from agricultural soils. Up to now, little attention has been paid to the ecology of the organisms responsible for denitrification. It is pointed out that chemotaxis would probably offer a strong competitive mechanism for denitrifiers, since chemotaxis would allow denitrifiers to actively reach nitrate by directed motility, rather than by random movement or diffusion of nitrate. The present investigation was initiated to examine the chemotactic responses of several denitrifiers to nitrate and nitrite. Attention is given to bacterial strains, culture media and cell preparation, chemotaxis assays, and competition experiments. It was found that several denitrifiers, including P. aeruginosa, P. fluorescens, and P. Stutzeri, were strongly attracted to NO3(-) and NO2(-).

Kennedy, M. J.↗

Mach number validation of a new zonal CFD method (ZAP2D) for airfoil simulations

A closed-loop overlapped velocity coupling procedure has been utilized to combine a two-dimensional potential-flow panel code and a Navier-Stokes code. The fully coupled two-zone code (ZAP2D) has been used to compute the flow past a NACA 0012 airfoil at Mach numbers ranging from 0.3 to 0.84 near the two-dimensional airfoil C(lmax) point for a Reynolds number of 3 million. For these cases, the grid domain size can be reduced to 3 chord lengths with less than 3-percent loss in accuracy for freestream Mach numbers through 0.8. Earlier validation work with ZAP2D has demonstrated a reduction in the required Navier-Stokes computation time by a factor of 4 for subsonic Mach numbers. For this more challenging condition of high lift and Mach number, the saving in CPU time is reduced to a factor of 2.

Strash, Daniel J.↗

NASA'S Standard Measures During Bed Rest: Adaptations in the Cardiovascular System

Bed rest is a well-accepted analog of space flight that has been used extensively to investigate physiological adaptations in a larger number of subjects in a shorter amount of time than can be studied with space flight and without the confounding effects associated with normal mission operations. However, comparison across studies of different bed rest durations, between sexes, and between various countermeasure protocols have been hampered by dissimilarities in bed rest conditions, measurement protocols, and testing schedules. To address these concerns, NASA instituted standard bed rest conditions and standard measures for all physiological disciplines participating in studies conducted at the Flight Analogs Research Unit (FARU) at the University of Texas-Medical Branch. Investigators for individual studies employed their own targeted study protocols to address specific hypothesis-driven questions, but standard measures tests were conducted within these studies on a non-interference basis to maximize data availability while reducing the need to implement multiple bed rest studies to understand the effects of a specific countermeasure. When possible, bed rest standard measures protocols were similar to tests nominally used for medically-required measures or research protocols conducted before and after Space Shuttle and International Space Station missions. Specifically, bed rest standard measures for the cardiovascular system implemented before, during, and after bed rest at the FARU included plasma volume (carbon monoxide rebreathing), cardiac mass and function (2D, 3D and Doppler echocardiography), and orthostatic tolerance testing (15- or 30-minutes of 80 degree head-up tilt). Results to-date indicate that when countermeasures are not employed, plasma volume decreases and the incidence of presyncope during head-up tilt is more frequent even after short-duration bed rest while reductions in cardiac function and mass are progressive as bed rest duration increases. Additionally, while plasma volume loss can be corrected and cardiac mass can be prevented with properly applied countermeasures, orthostatic tolerance is more difficult to protect when supine exercise is the only countermeasure. Similar results have been observed after space flight. Plasma volume, cardiac chamber volume, and orthostatic tolerance recover relatively quickly with resumption of ambulation and normal activity levels after bed rest but restoration of cardiac mass is prolonged.

Lee, Stuart M. C.↗

Results of NASA Technical Challenge to Demonstrate Two-Speed Drive for Vertical Lift Vehicle

Currently, manned vertical lift vehicles are flown in a manner such that the rotors operate over a narrow range of rotating speed regardless if the vehicle's flight condition is one of vertical takeoff and landing, hover, or forward cruise. The propulsion systems are optimized for operation at the same, corresponding narrow range of rotor speed. However, certain missions and markets benefit greatly if the rotor speed can be adjusted over a wide range of speed to match demands of different missions and flight regimes. A vehicle that can operate with a wide range of rotor speeds would address key barriers to enable new markets and missions for vertical lift vehicles. Key barriers addressed by the wide-range of rotor speed include noise reduced via lower rpm rotor, increase of maximum forward flight speed, increased payload and range, reduced fuel burn, and lower operating costs. A new paradigm for the propulsion system is needed to enable these key benefits. One viable approach is to make use of a two-speed ratio drive system such that the engine can continue to operate over a narrow speed range, whereby engine performance is optimal, while adjusting the rotor speed as needed using the two-speed drive system. Motivated by such needs and by results of several system studies, a NASA Revolutionary Vertical Lift Technology Challenge was established to develop and demonstrate required technologies and designs for achieving a 50% reduction in rotor rpm via a two-speed drive system that incurs less than 2% power loss and maintains current power-to-weight ratios. The technical challenge work was completed and the technical objectives were achieved. This report describes the motivations, the research approach and the significant outcomes.

Transmissions↗