Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

DIRECT SIMULTANEOUS MEASUREMENT OF PARTICULATE MATTER AND AMMONIA STORAGE ON COMBINED SELECTIVE CATALYTIC REDUCTION FILTER SYSTEMS USING RADIO FREQUENCY SENSORS

Tightening global emissions regulations are motivating interest in the development and implementation of Selective Catalytic Reduction + Filtration (SCRF) systems, which are designed to reduce the concentration of tailpipe particulate matter (PM) and NO x emissions. These systems allow designers to combine the NO x reduction capability of an SCR with the filtration capability of a particulate filter on a single unit. Practical implementation of these systems requires reliable measurement and diagnosis of their state – both with respect to trapped particulate matter as well as adsorbed ammonia. Currently, these systems rely on a variety of gas sensors, mounted upstream or downstream of the system, that only provide an indirect inference of the operation state. In this study, a single radio frequency (RF) sensor was used to perform simultaneous measurements of soot loading and ammonia inventory on an SCRF. Several SCRF core samples were tested at varying soot and ash loads in a catalyst reactor bench. Soot levels were measured by monitoring changes in the bulk dielectric properties within the catalyst using the sensor, while ammonia levels were determined by feeding selected regions of the RF spectrum into a pretrained generalized regression neural network model. Results show the RF sensor is able to directly measure the instantaneous ammonia inventory, while simultaneously providing soot loading measurements within 0.5 g/L. These results confirm that simultaneous measurements of both the PM and ammonia loading state of an SCRF are possible using a single RF sensor via analysis of specific features in the full RF spectrum. The results indicate significant potential to remove the control barriers typically associated with the implementation of advanced SCRF systems.

Ragaller, Paul↗

AGC 3 Irradiated Material Properties Analysis

This report documents the analysis of the irradiated material property data from the Advanced Graphite Creep (AGC)-3 graphite specimens. This is the third in a series of six irradiation test trains planned as part of the AGC experiment to fully characterize the neutron irradiation effects and radiation creep behavior of current nuclear graphite grades. The AGC-3 capsule was irradiated in the Idaho National Laboratory Advanced Test Reactor at a nominal temperature of 800°C, beginning with irradiation Cycle 152B on November 28, 2012 and ending with Cycle 155B on April 12, 2014, with a total received dose range of 0.9–3.7 dpa. Larger creep and control specimens located more centrally in the capsule received a dose of 1.0 – 3.7 dpa. AGC-3 was designed to provide irradiation conditions similar to AGC-1 and AGC-2 capsules (similar graphite grades tested, specimen dimensions, mechanical loading conditions) but at a different nominal irradiation temperature of 800°C. AGC-3 was irradiated for a short duration to provide material property values at lower dose levels. AGC-4 will have a longer duration and provide material property values at higher dose levels. After irradiation, material property and dimensional strain measurements were conducted on all AGC-3 specimens (from 11 nuclear graphite grades) using the same equipment and approved standards as were conducted before irradiation. The specimen loading configuration for all graphite grades within AGC-3 followed a similar pattern as earlier AGC capsules to provide easy future comparison of all irradiated material property data.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Persistent Elevated Soot Emissions Induced by Clustered Stochastic Preignition Events

Stochastic Preignition (SPI) is an abnormal combustion phenomenon that can occur in spark-ignition engines particularly under high-load operation. SPI is characterized by uncontrolled initiation of combustion prior to spark discharge, an abnormal combustion process that can lead to severe knock events and significant engine damage. SPI has been associated with fuel properties, lubricant composition, and engine design and operation. Here, in this work, a single-cylinder test engine with a dry-sump oil system was utilized to study the SPI response of E10 and E25 fuels with a range of Reid Vapor Pressure (RVP). An automated test procedure was employed, consisting of ten square-waved load profile segments, with each segment composed of 5 min of low-load operation followed by 25 min of sustained high-load operation. These tests were replicated across multiple days of testing including a lubricant triple flush between tests, and an online Fuel in Oil diagnostic measurement. Exhaust particulate emissions were continuously measured by an AVL microsoot sensor (MSS). Elevated particulate matter emissions were observed to occur concurrently with SPI events as blooms of soot. Particularly after clustered events (i.e., multiple SPI cycles occurring within 10 consecutive engine cycles), high soot emissions were observed to persist over several days of sequential operation despite daily lubricant changes, a complete warm-up procedure, and sustained low-load operation between test segments. This result implies that the particulate emissions trends may be dominated by deposit-based effects, where higher load operation is needed to alter deposition and formation processes. The observed soot blooms were also found to correspond to a reduction in the engine fueling and the fuel engine oil dilution rate despite the engine exhaust remaining at stoichiometric exhaust operation. These observations suggest that post-SPI events, pathways for lubricant migration and consumption into the combustion chamber may occur until these pathways are closed from deposit formation or ring dynamics during extended operation. These observed sooting propensity persisted with all fuels tests, but a linear correlation was observed between the summation of soot and particulate matter index (PMI) value for each fuel as well as SPI events, proving that PMI is a crucial fuel property for reducing SPI.

Splitter, Derek [Oak Ridge National Laboratory (OR↗

Climate Control Load Reduction Strategies for Electric Drive Vehicles in Warm Weather

Passenger compartment climate control is one of the largest auxiliary loads on a vehicle. Like conventional vehicles, electric vehicles (EVs) require climate control to maintain occupant comfort and safety, but cabin heating and air conditioning have a negative impact on driving range for all electric vehicles. Range reduction caused by climate control and other factors is a barrier to widespread adoption of EVs. Reducing the thermal loads on the climate control system will extend driving range, thereby reducing consumer range anxiety and increasing the market penetration of EVs. Researchers at the National Renewable Energy Laboratory have investigated strategies for vehicle climate control load reduction, with special attention toward EVs. Outdoor vehicle thermal testing was conducted on two 2012 Ford Focus Electric vehicles to evaluate thermal management strategies for warm weather, including solar load reduction and cabin pre-ventilation. An advanced thermal test manikin was used to assess a zonal approach to climate control. In addition, vehicle thermal analysis was used to support testing by exploring thermal load reduction strategies, evaluating occupant thermal comfort, and calculating EV range impacts. Through stationary cooling tests and vehicle simulations, a zonal cooling configuration demonstrated range improvement of 6%-15%, depending on the drive cycle. A combined cooling configuration that incorporated thermal load reduction and zonal cooling strategies showed up to 33% improvement in EV range.

33 ADVANCED PROPULSION SYSTEMS↗

Report on FY19 Testing in Support of Integrated EPP-SMT Design Methods Development

Experiments in support of the development of the integrated Elastic–Perfectly Plastic (EPP) analysis and Simplified Model Test (SMT) design methodology continued in FY 2019. Major progress was made in the verification of the newly developed two-bar SMT and single-bar SMT (SBSMT) methods by performing tests on Alloy 617 and SS 316H at high temperatures. Comparable results were achieved when the materials were tested under same conditions using both techniques. Because of its simple test configuration, SBSMT was the preferred testing technique used to evaluate elastic follow-up effect and generate data in support of SMT-based design curves. Evaluation of elastic follow-up was started with testing SS 316H at 815°C using SBSMT in this reporting period. As a result of this effort, the basic procedure and test protocol to provide data in support of the development of SMT-based design curves were established. This report also summarizes recent test results for the pressurization SMT using test articles with key features on Alloy 617 at intermediate strain ranges and at a low temperature of 850°C. Although more test results are needed in order to fully understand the effect of primary load on SMT creep-fatigue (CF) life, the limited test data indicate that the primary load reduced the SMT life at intermediate strain ranges and high temperatures. Recognizing the advantages of the newly developed SBSMT method, a new test geometry was designed to allow the elevation of the primary load effect on SMT CF life with the SBSMT technique. Additionally, selected tests were performed on SS 316H (heat 101076) to provide basic information about the heat of material. The tests performed included high-temperature tensile, fatigue, creep fatigue, and thermomechanical experiments. The results will be used to support the verification of the material constitutive model developed at Argonne National Laboratory.

36 MATERIALS SCIENCE↗

PLUTONIUM SOLUBILITY IN HIGH-LEVEL WASTE ALKALI BOROSILICATE GLASS

The solubility of plutonium in a Sludge Batch 6 (SB6) reference glass and the effect of incorporation of Pu in the glass on specific glass properties were evaluated. A Pu loading of 1 wt % in glass was studied. Prior to actual plutonium glass testing, surrogate testing (using Hf as a surrogate for Pu) was conducted to evaluate the homogeneity of significant quantities of Hf (Pu) in the glass, determine the most appropriate methods to evaluate homogeneity for Pu glass testing, and to evaluate the impact of Hf loading in the glass on select glass properties. Surrogate testing was conducted using Hf to represent between 0 and 1 wt % Pu in glass on an equivalent molar basis. A Pu loading of 1 wt % in glass translated to {approx}18 kg Pu per Defense Waste Processing Facility (DWPF) canister, or about 10X the current allowed limit per the Waste Acceptance Product Specifications (2500 g/m{sup 3} of glass or about 1700 g/canister) and about 30X the current allowable concentration based on the fissile material concentration limit referenced in the Yucca Mountain Project License Application (897 g/m{sup 3}3 of glass or about 600 g Pu/canister). Based on historical process throughput data, this level was considered to represent a reasonable upper bound for Pu loading based on the ability to provide Pu containing feed to the DWPF. The task elements included evaluating the distribution of Pu in the glass (e.g. homogeneity), evaluating crystallization within the glass, evaluating select glass properties (with surrogates), and evaluating durability using the Product Consistency Test -- Method A (PCT-A). The behavior of Pu in the melter was evaluated using paper studies and corresponding analyses of DWPF melter pour samples.The results of the testing indicated that at 1 wt % Pu in the glass, the Pu was homogeneously distributed and did not result in any formation of plutonium-containing crystalline phases as long as the glass was prepared under 'well-mixed' conditions. The incorporation of 1 wt % Pu in the glass did not adversely impact glass viscosity (as assessed using Hf surrogate) or glass durability. Finally, evaluation of DWPF glass pour samples that had Pu concentrations below the 897 g/m{sup 3} limit showed that Pu concentrations in the glass pour stream were close to targeted compositions in the melter feed indicating that Pu neither volatilized from the melt nor stratified in the melter when processed in the DWPF melter.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Frequency Responsive Demand in U.S. Western Power System Model

Frequency control from the demand side presents a novel and viable way to complement control by traditional generators. This paper presents simulation tests of a previously developed load controller in a large interconnected system model. The controller was implemented as a user defined model in PowerWorld software. WECC system model was used. The simulation tests include comparison of situation with and without control, sensitivities to controller location, control gain parameters, and type of end-use loads. The performance is measured in terms of frequency and intertie power flow deviations after a large generator outage.

Power system dynamics, power system control↗

A synthetic building operation dataset

Abstract This paper presents a synthetic building operation dataset which includes HVAC, lighting, miscellaneous electric loads (MELs) system operating conditions, occupant counts, environmental parameters, end-use and whole-building energy consumptions at 10-minute intervals. The data is created with 1395 annual simulations using the U.S. DOE detailed medium-sized reference office building, and 30 years’ historical weather data in three typical climates including Miami, San Francisco, and Chicago. Three energy efficiency levels of the building and systems are considered. Assumptions regarding occupant movements, occupants’ diverse temperature preferences, lighting, and MELs are adopted to reflect realistic building operations. A semantic building metadata schema - BRICK, is used to store the building metadata. The dataset is saved in a 1.2 TB of compressed HDF5 file. This dataset can be used in various applications, including building energy and load shape benchmarking, energy model calibration, evaluation of occupant and weather variability and their influences on building performance, algorithm development and testing for thermal and energy load prediction, model predictive control, policy development for reinforcement learning based building controls.

24 POWER TRANSMISSION AND DISTRIBUTION↗

AlphaBuilding - Synthetic Buildings Operation Dataset

This is a synthetic building operation dataset which includes HVAC, lighting, miscellaneous electric loads (MELs) system operating conditions, occupant counts, environmental parameters, end-use and whole-building energy consumptions at 10-minute intervals. The data is created with 1395 annual simulations using the U.S. DOE detailed medium-sized reference office building, and 30 years' historical weather data in three typical climates including Miami, San Francisco, and Chicago. Three energy efficiency levels of the building and systems are considered. Assumptions regarding occupant movements, occupants' diverse temperature preferences, lighting, and MELs are adopted to reflect realistic building operations. A semantic building metadata schema - BRICK, is used to store the building metadata. The dataset is saved in a 1.2 TB of compressed HDF5 file. This dataset can be used in various applications, including building energy and load shape benchmarking, energy model calibration, evaluation of occupant and weather variability and their influences on building performance, algorithm development and testing for thermal and energy load prediction, model predictive control, policy development for reinforcement learning based building controls.

AlphaBuilding↗

Measured Performance of Residential Dehumidifiers Under Cyclic Operation

Residential construction practices are progressing toward higher levels of energy efficiency. A proven strategy to save energy is to simultaneously increase building insulation levels and reduce outdoor air infiltration. Tight homes require intentional mechanical ventilation to ensure healthy indoor air. Overall, this strategy results in a shift in the mix of latent and sensible space conditioning loads, requiring proportionally more moisture to be removed compared to standard homes. There is currently not sufficient information available at a wide enough range of operating points to design dehumidification systems for high performance homes in hot-humid climates. The only industry information available on dehumidifier moisture removal and energy consumption are performance ratings conducted at a single test condition, which does not provide a full representation of dehumidifier operation under real-world conditions. Winkler et al. (2011) developed steady state performance maps to predict dehumidifier performance at a variety of indoor conditions. However, installed heating, ventilating, and air-conditioning (HVAC) equipment rarely operates at steady state. Part load performance testing of residential dehumidifiers is not mandated by current test standards. Therefore, we tested the part load performance of four residential dehumidifiers in the National Renewable Energy Laboratory's (NREL) Advanced HVAC Systems Laboratory . The part load efficiency of each dehumidifier was measured under 13 cycling scenarios, and combined with NREL field data to develop part load fraction (PLF) performance curves under realistic cycling scenarios.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Using a cold radiometer to measure heat loads and survey heat leaks

We have developed an inexpensive cold radiometer for use in thermal/vacuum chambers to measure heat loads, characterize emissivity and specularity of surfaces and to survey areas to evaluate stray heat loads. We report here the results of two such tests for the James Webb Space Telescope to measure heat loads and effective emissivities of 2 major pieces of optical ground support equipment that will be used in upcoming thermal vacuum testing of the Telescope.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Hierarchical VLSM-Based Demand Response Strategy for Coordinative Voltage Control between Transmission and Distribution Systems

This paper presents a two-stage hierarchical voltage-load sensitivity matrix (VLSM)-based demand response (DR) algorithm for regulating the voltage at distribution feeders while fulfilling the transmission system DR requests. This allows distributed energy resources be aggregated to provide transmission-level services without causing operational issues in the distribution grids. At the beginning of each operation interval, a transmission system controller will issue DR commands to distribution system controllers. In the first stage, the distribution system controller uses a VLSM-based dispatch algorithm to dispatch the available DR resources on the distribution feeder with an objective to minimize the total voltage deviations at the lowest cost. Then, power flow studies are conducted assuming that the DR commands have been executed. If voltage violations are detected, a second-stage VLSM-based DR dispatch will be performed to remove those violations. After that, the upper and lower DR limits calculated for the next operation interval are sent back to the transmission system controller so the transmission optimization algorithm can use them as operational constraints to make subsequent decisions. The DR resources include smart photovoltaic (PV) inverters that can curtail real power and provide reactive power support, controllable loads and capacitor banks. In conclusion, the IEEE 123-bus test system with 5-minute PV and load data is used to evaluate the performance of the algorithm. In conclusion, simulation results show that the proposed algorithm can fulfill the transmission-level DR requests while maintaining the voltage in the distribution system within limits.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Radium and Thorium Sorption by Monosodium Titanate (MST) and Modified MST (mMST)

A series of tests were planned to examine the removal of Ra and Th by monosodium titanate (MST) and modified monosodium titanate (mMST). Simulated waste solutions were prepared containing Ra and Th, along with Sr, Np, Pu, and U. Following simulant preparation the simulants were filtered through 0.45-m filters. Analysis of the simulants indicated no Th in the filtered solution. This is due to the very low solubility of Th in alkaline solutions. Based on the reported detection limits for 228 Th by gamma analyses, the solubility of Th in the simulant solutions is < 3.0E-10 g/L or < 1.3E-12 M. Therefore, data could not be obtained regarding the removal of Th by MST and mMST; however, testing proceeded to examine the removal of Ra. Sorption testing indicated that Ra, like Sr, is very rapidly removed from solution by both MST and mMST. The Ra concentration in solution fell below the method detection limit (MDL) within 30 minutes of contact with MST, and within 2 hours of contact with mMST, when tested at 25 °C using a 5.6 M Na simulant. Additional testing examined the effects of ionic strength and temperature on the MST and mMST performance. Results from these tests showed that the majority of samples still reached a Ra concentration below the MDL, indicating excellent removal. For the highest ionic strength solution (6.6 M Na), there did appear to be a slight decrease in the Ra removal by mMST, as indicated by a larger number of samples just above the MDL. The effect of temperature on 226 Ra removal is indeterminate for either MST or mMST in the temperature range (25-60 °C) and concentrations studied since the final soluble concentration of Ra remained at or below the detection limits for all tests. Desorption testing was also performed using decontaminated salt solution (DSS) diluted to sodium concentrations of 2 M and 0.5 M, to represent the intermediate and final stages of washing. Results from these tests indicated no desorption of any sorbents, with the exception of Pu from mMST, which desorbed slightly (0.02%). Rather, the testing showed additional sorption of sorbates, likely due to the higher sorbent concentrations in these tests compared to the concentrations used for loading (i.e. 13 g/L vs. 0.4 g/L). SRNL recommends additional testing to confirm the low solubility of Th in a range of simulants representing SRS HLW. We also recommend additional sorption testing with simulants containing a higher concentration of 226Ra, to allow for the determination of actual DF values, rather than the minimum DF values reported here.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

FY21 Status Report on Creep Rupture Testing at ANL to Support the Development of Alloy 709 Code Case

This report provides an update on the status of the creep rupture testing on the first commercial heat of Alloy 709 in support of the Alloy 709 Code Case development. Creep tests were performed in air on the lever-arm load frames in the Mechanical and Environmental Testing Laboratory at Argonne National Laboratory (ANL). In FY21, the focus was on the age-hardened ESR-1150°C material. Twenty two tests were initiated, among which ten were completed. This report presents the data from the completed tests. Metallographic characterization of the fractured specimens were performed and the results are included. The creep data enabled the preliminary analysis of the creep behavior of this material. The characterization showed the effect of test temperature and stress on the deformation microstructure.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

High Waste Loading Glass Formulation Development for High-Zr HLW

This report describes work performed to develop and test new glass and feed formulations in order to increase waste loadings and glass melting rates for Hanford HLW with high concentrations of zirconium. Testing was designed to identify glass and melter feed formulations that optimize waste loading and waste processing rate while meeting all processing and product quality requirements. The work included preparation and characterization of crucible melts to evaluate the effects of waste loading on glass properties and the maximum waste loadings that can be achieved. The testing included an assessment of melt rate using a Vertical Gradient Furnace (VGF) system to develop new formulations with both high waste loadings and high melt rates. The results from crucible-scale testing supported subsequent DM100 tests designed to further assess the enhanced glass and feed formulations with respect to processing rate and product quality.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization of Creep-Fatigue Crack Growth in Alloy 709 and Prediction of Service Lives in Nuclear Reactor Components (Final Report)

This final report summarizes the activities and results that were obtained by the research team working on the project “Characterization of Creep-Fatigue Crack Growth in Alloy 709 and Prediction of Service Lives in Nuclear Reactor Components”, DOE-NEUP Project 15-8623. This project was mainly concerned with the creep-fatigue crack growth characterization of austenitic stainless-steel Fe-20Cr-25Ni (Alloy 709). For this purpose, an array of experimental and computational activities was performed. The main goal of these activities was to describe and predict the crack growth behavior in Alloy 709 under different conditions of applied loading and temperature. Alloy 709 specimens were tested to describe both the uniaxial creep behavior and creep-fatigue crack growth rates at temperatures between 550°C and 700°C. Microstructure and fracture surface analysis was performed using several experimental techniques, and the defining features of crack growth propagation were identified and described. Thermodynamic and diffusion simulations were performed to understand the microstructure evolution of Alloy 709 at elevated temperatures, and to establish an aging schedule relevant for in-service conditions over extended periods. Experimental testing was performed on both as-received and aged Alloy 709 specimens. Two computational methods were developed to predict crack growth rates and remaining lives in specimens loaded under either fatigue of creep-fatigue. The first computational technique was the finite element method, while the second was strip-yield modeling. Both methods relied on the prediction of crack growth rates using the concept of plasticity-induced crack closure. Crack-tip opening loads were computed and used to perform crack growth rate predictions. The computational predictions matched well with the experimental results. The strip-yield model was shown to be an excellent predictive tool not only for crack growth in austenitic SS Alloy 709, but also in 316 SS, martensitic Cr-Mo steels, Ni-based alloys and Al-based alloys. The main conclusion of this study is that Alloy 709 exhibits excellent creep crack growth resistance at temperatures between 550°C and 700°C. In fact, the crack growth resistance of this alloy appears to be higher than that of 316 SS in similar testing conditions. Moreover, when creep loading with hold (dwell) times of 60s or 600s were intercalated every fatigue cycle, the crack growth rates did not change significantly. The conclusion is that the tests performed revealed that the crack growth is insignificant during the creep portion of a loading cycle, as compared with the crack growth during the fatigue portion of the cycle. In general, Alloy 709 shows excellent resistance to creep deformations and creep crack growth up to 700°C.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SystemBurn: Principles of Design and Operation, Release 2.0

As high performance computing technology progresses toward the progressively more extreme scales required to address critical computational problems of both national and global interest, power and cooling for these extreme scale systems is becoming a growing concern. A standardized methodology for testing system requirements under maximal system load and validating system environmental capability to meet those requirements is critical to maintaining system stability and minimizing power and cooling risks for high end data centers. Moreover, accurate testing permits the high end data center to avoid issues of under- or over-provisioning power and cooling capacity saving resources and mitigating hazards. Previous approaches to such testing have employed an ad hoc collection of tools, which have been anecdotally perceived to produce a heavy system load. In this report, we present SystemBurn, a software tool engineered to allow a system user to methodically create a maximal system load on large scale systems for the purposes of testing and validation.

99 GENERAL AND MISCELLANEOUS↗

SystemBurn: Principles of Design and Operation Release 2.1

As high performance computing technology progresses toward the progressively more extreme scales required to address critical computational problems of both national and global interest, power and cooling for these extreme scale systems is becoming a growing concern. A standardized methodology for testing system requirements under maximal system load and validating system environmental capability to meet those requirements is critical to maintaining system stability and minimizing power and cooling risks for high end data centers. Moreover, accurate testing permits the high end data center to avoid issues of under- or over-provisioning power and cooling capacity saving resources and mitigating hazards. Previous approaches to such testing have employed an ad hoc collection of tools, which have been anecdotally perceived to produce a heavy system load. In this report, we present SystemBurn, a software tool engineered to allow a system user to methodically create a maximal system load on large scale systems for the purposes of testing and validation.

99 GENERAL AND MISCELLANEOUS↗