Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load reduction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Numerical characterization of quasi-steady thermal load for thin crystal at cryogenic temperature with nondiffusive heat transfer

With dramatically improved brightness and repetition rate, the thermal load for crystal optics in x-ray free-electron laser applications has also significantly increased. To mitigate the thermal load, one effective method is cryogenic cooling. However, the emerging nondiffusive heat transfer phenomenon at cryogenic temperature may cause design failure if overlooked. To evaluate the optical performance of thin crystal optics under thermal load at cryogenic temperature, an integrated numerical tool is presented and applied to characterize the thermal load on thin crystals with nondiffusive phenomena accounted. Significant thermally induced distortion of the rocking curve is observed from numerical simulation, leading to potential seed power reduction in hard x-ray self-seeding application. Cryogenic cooling is confirmed necessary by simulation to handle the thermal load at high repetition rate operation.

42 ENGINEERING↗

Optimizing tuning masses for helicopter rotor blade vibration reduction including computed airloads and comparison with test data

An optimization procedure is developed for locating tuning masses on a rotor blade so that vibratory loads are minimized and hub-shear harmonics are reduced without adding a large mass penalty. The airloads are computed by means of a helicopter analysis for the cases of three vs six tuning masses, with attention given to the prediction of changes in airloads. Frequencies, airloads, and hub loads are computed with the CAMRAD/JA helicopter analysis code and the Conmin general-purpose optimization program. The hub shear is found to be significantly reduced in both cases with the added mass, and the reduction of hub shear is demonstrated under three flight conditions. Comparisons with wind-tunnel data demonstrate that the correlation of mass location is good and the relationship between mass location and flight speed is predicted well by the model.

Pritchard, Jocelyn I.↗

Component test results from the bearing life improvement program for the Space Shuttle Main Engine oxidizer turbopumps

Interim results from a component test program to improve ball bearing life in the Space Shuttle Main Engine oxygen turbopumps are presented. Two specific bearing applications, using liquid oxygen as the bearing coolant, are addressed. The first, the thrust bearing of the low pressure pump, operates at relatively slow speed with predominantly axial load and little temperature rise in the bulk coolant. Testing has demonstrated a very significant reduction in bearing wear by increasing the bearing internal clearance. Heat generation data was obtained that indicates heavy, intermittent cage-to-ball contact occurs, providing a possible explanation for the observed wear. The second application is the turbine end bearings of the high pressure pump. These bearings operate at high speed and load with the possibility of significant coolant vaporization. Tests on production bearings and bearings having modified internal clearance and curvature yielded scattered but generally poor lives. A dramatic improvement was achieved by coating the standard cage with a thin film of fluorinated ethylene propylene and 15 percent molybdenum disulfide. Very promising results have also been obtained by replacing the standard balls with ones made of silicon nitride, especially in combination with the coated cage.

Keba, John E.↗

Managing Power Systems-Induced Wildfire Risks Using Optimal Scheduled Shutoffs

The increasing demands for electricity and the increase in extreme weather conditions are putting unprecedented pressure on our electric grids. Often, this pressure leads to electrical component failures, which might ignite wildfires. This work develops a novel model to balance the reliability of power network operations and the risk of wildfire ignition by opti- mizing the operational schedule of power transmission networks considering time-varying risk measures that include exogenous and operational factors. Energy storage systems are considered to deliver power during peak wildfire hours and enable temporal load shifting. The problem is formulated as a mixed-integer linear program that maximizes a weighted sum of the served power demand and the reduction in grid-induced wildfire risk. The results demonstrate the ability of the model to significantly reduce wildfire risk without considerable load shedding.

power systems operations↗

Managing Power Systems-Induced Wildfire Risks Using Optimal Scheduled Shutoffs: Preprint

The growing demands for electricity and the increase in extreme weather conditions are putting unprecedented pressure on our electrical grids. Oftentimes, this pressure leads to electrical components failures which might ignite wildfires. This work develops a novel model to balance the reliability of power networks operations and risks of wildfires ignition by optimizing the operational schedule of power transmission networks considering time-varying risk measures that consider exogenous and operational factors. Energy storage systems are considered to deliver power during peak wildfire hours and enable temporal load shifting. The problem is formulated as a mixed-integer linear program that maximizes a weighted sum of the served power demand and the reduction in grid-induced wildfires risk. The results demonstrate the ability of the model to reduce wildfires risks significantly without considerable load shedding.

energy scheduling↗

Lead-Lag Control for Helicopter Vibration and Noise Reduction

As a helicopter transitions from hover to forward flight, the main rotor blades experience an asymmetry in flow field around the azimuth, with the blade section tangential velocities increasing on the advancing side and decreasing on the retreating side. To compensate for the reduced dynamic pressure on the retreating side, the blade pitch angles over this part of the rotor disk are increased. Eventually, a high enough forward speed is attained to produce compressibility effects on the advancing side of the rotor disk and stall on the retreating side. The onset of these two phenomena drastically increases the rotor vibratory loads and power requirements, thereby effectively establishing a limit on the maximum achievable forward speed. The alleviation of compressibility and stall (and the associated decrease in vibratory loads and power) would potentially result in an increased maximum forward speed. In the past, several methods have been examined and implemented to reduce the vibratory hub loads. Some of these methods are aimed specifically at alleviating vibration at very high flight speeds and increasing the maximum flight speed, while others focus on vibration reduction within the conventional flight envelope. Among the later are several types passive as well as active schemes. Passive schemes include a variety of vibration absorbers such as mechanical springs, pendulums, and bifilar absorbers. These mechanism are easy to design and maintain, but incur significant weight and drag penalties. Among the popular active control schemes in consideration are Higher Harmonic Control (HHC) and Individual Blade Control (IBC). HHC uses a conventional swash plate to generate a multi-cyclic pitch input to the blade. This requires actuators capable of sufficiently high power and bandwidth, increasing the cost and weight of the aircraft. IBC places actuators in the rotating reference frame, requiring the use of slip rings capable of transferring enough power to the actuators. Both schemes cause an increase in pitch link loads. Trailing Edge Flap (TEF) deployment can also used to generate unsteady aerodynamic forces and moments that counter the original vibratory loads, and thereby reduce rotor vibrations. While the vibrations absorbers, HHC, IBC, and TEF concepts discussed above attempt to reduce the vibratory loads, they do not specifically address the phenomena causing the vibrations at high advance ratios. One passive method that attempts to directly alleviate compressibility and stall, instead of reducing the ensuing vibrations, is the use of advanced tip designs. Taper, sweep, anhedral, and the manipulation of other geometric properties of the blade tips can reduce the severity of stall and compressibility effects , as well as reduce rotor power. A completely different approach to solve these problems is the tiltrotor configuration. As the forward velocity of the aircraft increases, the rotors, in this case, are tilted forward until they are perpendicular to the flow and act as propellers. This eliminates the edgewise flow encountered by conventional rotors and circumvents all the problems associated with flow asymmetry. However, the success involves a tremendous increase in cost and complexity of the aircraft. Another possible approach that has been proposed for the alleviation of vibratory loads at high forward flight speeds involves the use of controlled lead-lag motions to reduce the asymmetry in flow. A correctly phased 1/rev controlled lag motion could be introduced such that it produces a backward velocity on the advancing side and a forward velocity on the retreating side, to delay compressibility effects and stall to a higher advance ratio. Using a large enough lead-lag amplitude, the tip velocities could be reduced to levels encountered in hover. This concept was examined by two groups in the 1950's and early 1960's. In the United States, the Research Labs Division of United Aircraft developed a large lead-lag motion rotor, meant to achieve lag motion amplitudes up to 45 degrees. In order to reduce the required actuation force, the blade hinges were moved to 40% of the blade radius to increase the rotating lag frequency to approximately 1/rev. The blade hinges were redesigned to produce a flap-lag coupling so the large flapwise aerodynamic loads could be exploited to actuate the blades in the lag direction. A wind tunnel test of this rotor concept revealed actuation and blade motion scheduling problems. The project was eventually discontinued due to these problems and high blade stresses. Around the same time, at Boelkow in Germany, a similar lead-lag rotor program was conducted under the leadership of Hans Derschmidt. Here, too, the blade hinges were moved outboard to 34% radius to reduce the actuation loads. The main difference between this and the United Aircraft program was the use of a mechanical actuation scheme with maximum lead-lag motions of 400. This program was also discontinued for unclear reasons. The present study is directed toward conducting a comprehensive analytical examination to evaluate the effectiveness of controlled lead-lag motions in reducing vibratory hub loads and increasing maximum flight speed. Since both previous studies on this subject were purely experimental, only a limited data set and physical understanding of the problem was obtained. With the currently available analytical models and computational resources, the present effort is geared toward developing an in-depth physical understanding of the precise underlying mechanisms by which vibration reduction may be achieved. Additionally, in recognition of the fact that large amplitude lead-lag motions would - (i) be difficult to implement, and (ii) produce very large blade stresses; the present study examines the potential of only moderate-to-small lead-lag motions for reduction of vibratory hub loads. Using such an approach, the emphasis is not on eliminating the periodic variations in tangential velocity at the blade tip, but at best reducing these variations slightly so that compressibility and stall are delayed to slightly higher advance ratios. This study was conducted in two steps. In the first step, a hingeless helicopter rotor was modeled using rigid blades undergoing flap-lag-torsion rotations about spring restrained hinges and bearings. This model was then modified by separating the lead-lag degree of freedom into two components, a free and a prescribed motion. Using this model, a parametric study of the effect of phase and amplitude of a prescribed lead-lag motion on hub vibration was conducted. The data gathered was analyzed to obtain an understanding of the basic physics of the problem and show the capability of this method to reduce vibration and expand the flight envelope. In the second half of the study, the similar analysis was conducted using an elastic blade model to confirm the effects predicted by the simpler model.

Gandhi, Farhan↗

Exploring Grid-Interactive Efficient Building Strategies for Laboratories Through Energy Modeling

Laboratories are often overlooked in demand flexibility research due to constraints on their operations as mission critical facilities, despite the major role they play in an organization's emissions. Laboratories consume 3-4 times more energy than a typical office building and are commonly the largest energy users on any campus. Consequently, most laboratories in the United States are significant contributors to their organization's carbon footprint if their energy needs are met through the combustion of fossil fuels. As part of the initiative to decarbonize laboratories, this report documents an analysis on specifically grid-interactive efficient building (GEB) opportunities for reducing energy costs and emissions associated with laboratory operations. The goal of this initiative was to provide a case study and guidance on how to use OpenStudio and REopt as modeling tools for GEB technologies and strategies in laboratory environments across different climate zones in the United States. The analysis found that efficiency-based GEB strategies had the most significant impact on laboratory operations, while load-shedding and load-shifting GEB strategies produced smaller results. The culmination of these approaches applied across all five climate zones generated on average: 1) 28% energy cost savings and 30% greenhouse gas (GHG) emissions reductions, and 2) 4% enhanced energy cost savings under a time-of-use (TOU) pricing schedule compared to traditional pricing schemes. Grid-interactive efficiency building measures were found to produce the greatest energy savings in both electricity and natural gas, particularly in regions with high electrical loads, such as warm climates for cooling. Laboratories that had high levels of natural gas consumption, meanwhile, experienced the greatest emission reductions. The report concludes with an analysis on the opportunities for flexible loads in lab spaces and how small-scale measures in addition to opaque pricing structures for peak demand could become barriers to demand flexibility planning. The report also explores how electrifying laboratory buildings with heat pumps could reduce energy costs and GHG emissions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Buckling of conical shell with local imperfections

Small geometric imperfections in thin-walled shell structures can cause large reductions in buckling strength. Most imperfections found in structures are neither axisymmetric nor have the shape of buckling modes but rather occur locally. This report presents the results of a study of the effect of local imperfections on the critical buckling load of a specific axially compressed thin-walled conical shell. The buckling calculations were performed by using a two-dimensional shell analysis program referred to as the STAGS (Structural Analysis of General Shells) computer code, which has no axisymmetry restrictions. Results show that the buckling load found from a bifurcation buckling analysis is highly dependent on the circumferential arc length of the imperfection type studied. As the circumferential arc length of the imperfection is increased, a reduction of up to 50 percent of the critical load of the perfect shell can occur. The buckling load of the cone with an axisymmetric imperfections is nearly equal to the buckling load of imperfections which extended 60 deg or more around the circumference, but would give a highly conservative estimate of the buckling load of a shell with an imperfection of a more local nature.

Cooper, P. A.↗

Potential-Controlled Deposition of Multilayer CO 2 Reduction Catalyst Films onto Silicon Photoelectrodes Demonstrates Thickness-Dependent Catalytic Rates

Covalently attaching molecular catalysts to semiconductor surfaces yields promising hybrid photoelectrode architectures for reducing CO 2 to higher-value carbon products. Polymeric molecular catalyst films have higher loading densities than their monolayer counterparts, promising greater rates of solar fuel production. Using photoassisted diazonium electrografting, multilayered films of a Re(apbpy)(CO) 3 Cl CO 2 -reduction catalyst were attached to low-doped p-type Si (pSi). Parallel characterization of the newly formed films with ellipsometry, XPS, and ICP-MS revealed that catalyst loading increased with increasingly negative applied grafting potentials (Vgraft), providing us an experimental test bed to study the effects of film thickness on photocatalytic performance. Controlled-potential electrolysis experiments showed enhanced CO evolution rates on all photoelectrodes with increasingly negative applied potentials (V app ), with thicker films exhibiting the greatest rates of enhancement. Competitive proton reduction reactions at the Si surface were not strongly linked to V app but dependent on film thickness, with thicker films showing increased CO-to-H 2 production ratios.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Application of Temperature Sensitivities During Iterative Strain-Gage Balance Calibration Analysis

A new method is discussed that may be used to correct wind tunnel strain-gage balance load predictions for the influence of residual temperature effects at the location of the strain-gages. The method was designed for the iterative analysis technique that is used in the aerospace testing community to predict balance loads from strain-gage outputs during a wind tunnel test. The new method implicitly applies temperature corrections to the gage outputs during the load iteration process. Therefore, it can use uncorrected gage outputs directly as input for the load calculations. The new method is applied in several steps. First, balance calibration data is analyzed in the usual manner assuming that the balance temperature was kept constant during the calibration. Then, the temperature difference relative to the calibration temperature is introduced as a new independent variable for each strain--gage output. Therefore, sensors must exist near the strain--gages so that the required temperature differences can be measured during the wind tunnel test. In addition, the format of the regression coefficient matrix needs to be extended so that it can support the new independent variables. In the next step, the extended regression coefficient matrix of the original calibration data is modified by using the manufacturer specified temperature sensitivity of each strain--gage as the regression coefficient of the corresponding temperature difference variable. Finally, the modified regression coefficient matrix is converted to a data reduction matrix that the iterative analysis technique needs for the calculation of balance loads. Original calibration data and modified check load data of NASA's MC60D balance are used to illustrate the new method.

Ulbrich, N.↗

Change in energy expenditure and brain and adrenal content of catecholamines in rats during muscular loading and hypokinesia

In male 1-7 month old rats, the growth and the protein content of skeletal muscles were higher than in female rats while the O2 consumption and the heart rate were lower. This is combined with reduction of the thyroid gland weight and of catecholamine content in adrenals at the age of 7 months. The development of male and female rats (1-7 month) under conditions of systematic muscular loads increases the growth tempo and protein of skeletal muscles and intensifies the degree of reduction of energy expenditure and the heart rate. This is accomplished by the greater reduction of relative weight of the thyroid gland and, at the age of 7 months, by reduction of the noradrenaline content in the brainstem. Hypodynamic conditions have the exact opposite effect.

Rozanova, V. D.↗

Performance evaluation of underground thermal storage integrated dual-source heat pump systems

The increasing demand for electricity stresses the existing electric grids. Buildings consume 73% of all U.S. electricity and are responsible for 30% of U.S. greenhouse gas emissions. Integrating thermal energy storage (TES) in building heating/cooling systems, which consume considerable electricity, can mitigate the challenges to electric grids. Here, this study reports on a novel thermal energy storage device integrated heat pump system to reshape the building electricity demand profile while maintaining thermal comfort. The annual performance of the proposed system has been evaluated through a dynamic system simulation with high fidelity in the Modelica platform. The dynamic model of the novel hybrid component named ‘dual purpose underground thermal battery’ was developed and validated. It was then incorporated into the system model. Given a time-of-use tariff, a rule-based control strategy was designed to shift the electric demand and switch the heat pump source for a typical single-family house in different climate zones of the United States. The system performance of the new TES-integrated dual-source heat pump was compared with that of a conventional air-source heat pump system. The results indicate that the proposed system can reduce the annual HVAC electricity cost by up to 52% while saving 45.2% on electricity consumption. In the Northern areas, the annual peak load of the HVAC system can be reduced by 64.9%. However, this reduction is less in the Southern areas as the system’s higher efficiency in winter dominates the overall energy-saving potential.

25 ENERGY STORAGE↗

Effects of the method of active site characterization for determining structure-sensitivity in Ag-catalyzed ethylene epoxidation

We report catalysts have been prepared on a low surface area α-Al 2 O 3 support used commercially for previous generation olefin epoxidation catalysts. Prescreening of the low surface area alumina (0.73 m 2 /g) indicated the absence of acid catalyzed isomerization of EO at an evaluation temperature of 210 °C. A 0.1 wt% Ag base material synthesized by incipient wetness impregnation of AgNO 3 was used as a base material for electroless deposition (ED) of additional Ag to increase particle sizes by controlled reduction of Ag + directly onto the preexisting Ag surface to form weight loadings between 0.3 and 5.0 wt% metal. A 12 wt% Ag/α-Al 2 O 3 using Ag 2 C 2 O 4 as the Ag precursor was also prepared to compare performance of the ED samples with a catalyst more typical of industrial formulations. Characterization by SEM, STEM, and hydrogen titration of oxygen precovered Ag characterized before and after catalytic evaluation indicated that microscopy is required to accurately represent distributions of Ag particle sizes, but H 2 titration of O-precovered Ag gives the best representation of active sites since it directly counts the number of Ag surface sites. Larger particles >100 nm are resistant to both Ag sintering and carbon foulant; TOF values were relatively insensitive to particle size with only a 2.2 × difference between the best and worst performing samples. Selectivity, which is not a function of TOF, shows the most significant structure sensitivity effect where particle sizes follow the trend 67 nm ≈ 92 nm (58% EO) < 157 nm (67% EO) < 211–542 nm (73% EO). The lower EO selectivities were also correlated with increased fouling for the smaller Ag sizes, suggesting that more strongly bound EO precursor(s) leads to combustion and CO 2 /H 2 O formation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Trace level of atomic copper in N-doped graphene quantum dots switching the selectivity from C 1 to C 2 products in CO electroreduction

To unravel the relationship between trace Cu on the metal-free catalysts toward CO/CO 2 reduction reaction (CO/CO 2 RR), we investigated the effect of trace Cu loading in N-doped graphene quantum dots (NGQDs) on CO/CO 2 RR. A general trend is that increasing the Cu loading in NGQDs switches the selectivity from C 1 (CH 4 ) to C 2 products in CORR. When 2.5 μg/cm 2 Cu with the atomic size is loaded on NGQDs, the selectivity shifts from 62% Faradaic efficiency (FE) of CH 4 to 52% FE of C 2 products in CORR. Further increasing the atomic Cu loading to 3.8 μg/cm 2 promotes the FE of C 2 products to 78%. CO 2 RR requires one order of magnitude higher Cu loading than CORR to switch the selectivity from C 1 to C 2 products due to the low partial pressure of CO. Finally, this study clarifies the distinct impact of trace (ppm level) Cu on the activity/selectivity between CORR and CO 2 RR.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hierarchical Transactive Control of Flexible Building Loads Under Distribution LMP

With grid modernization efforts, future distribution networks, which consist of various distributed generators and flexible loads, will be more flexible and active. All new network components of distributed energy resources (DERs) drive and enable the transition towards a market-based distribution net-work that seeks the optimal allocation of all DERs. To address challenges associated with DERs, one promising solution is to utilize demand-side flexibility of building loads facilitated by demand response (DR) programs and provide ancillary grid services through distribution-level markets. Under this new paradigm, this paper proposes an efficient DR management strategy incorporating emerging price signals of distribution markets, i.e., distribution locational marginal price (DLMP), based on a hierarchical transactive control approach. The proposed approach establishes a two-layer decision-making framework; the upper layer formulates a bilevel model to obtain an optimal demand response (ODR) under DLMP, and the lower layer employs model-free control to dispatch the (aggregated) ODR to individual end users. Numerical case studies using a modified IEEE 33 test network are performed to verify the effectiveness of the proposed approach; load shifting and peak shaving for the distribution system operator and payments’ reduction for end users while maintaining their comfort.

Park, Byungkwon↗

DC-Link Current Minimization Control for Current Source Converter-Based Solid-State Transformer

This article proposes a fast predictive control method and a small DC-link inductor to minimize the DC-link current in current-source converter (CSC)-based solid-state transformer. The DC-link current minimization can significantly reduce power loss and improve efficiency. The challenge of this problem is on improving both steady-state and dynamic performance. PI control methods and large DC-link inductors are conventionally used in the CSC but have limited dynamic performance. A model predictive control (MPC) method is proposed to achieve switching-cycle-level settling time, and the DC-link inductor is sized for 40% ripple to enable fast current change. Importantly, this article also proposes to minimize the DC-link current by varying the current even within a line cycle under single-phase load to improve the steady-state performance, in contrast with the reduction to a constant value in the literature. The proposed MPC features a constant switching frequency without weighting factors. The MPC does not have a high computational burden and is implemented in a regular digital controller for a prototype of soft-switching solid-state transformer (S4T) with reduced conduction loss. The effectiveness of the proposed method has been experimentally verified on the SiC S4T prototype during steady-state and dynamics under different multiport power flow conditions up to 2 kV peak. Here, the DC-link current in the experiments is close to the minimum current with a short zero-vector duration, which further verifies the performance of the proposed method.

14 SOLAR ENERGY↗

Identification and Testing of Electric Vehicle Fast Charger Cybersecurity Mitigations

Fast-charging infrastructure for electric vehicles (EVs) is needed to enable and achieve the national goals of transitioning the vehicle fleet toward more electrification. Idaho National Laboratory, Oak Ridge National Laboratory, and the National Renewable Energy Laboratory (NREL) have jointly worked to identify, evaluate, and mitigate potential cyber-related consequences associated with fast charger systems. NREL contributed by considering cyberattack scenarios and consequences associated with integrating distributed energy resources (DERs) at fast-charging stations. The dynamic nature of fast-charger load profiles would encourage site operators to incorporate solar for energy cost reduction and energy storage for peak demand cost management at future charging facilities with multiple fast chargers at a site. These energy resources would be monitored and coordinated via a site energy management controller with data exchange between devices and local power metering infrastructure; thus, networking between devices and the design of the system becomes important in the overall cybersecurity posture. In addition, component vendors and system operators might have remote interfaces to any of these systems. It is therefore important to understand the breadth of the cyberattack surface and potential strategies to mitigate impacts. This project has focused on components and protocols expected to be found within a local charging site that includes multiple chargers and DER resources. Our methods and results are summarized in this final report.

42 ENGINEERING↗

Series-parallel method of direct solar array regulation

A 40 watt experimental solar array was directly regulated by shorting out appropriate combinations of series and parallel segments of a solar array. Regulation switches were employed to control the array at various set-point voltages between 25 and 40 volts. Regulation to within + or - 0.5 volt was obtained over a range of solar array temperatures and illumination levels as an active load was varied from open circuit to maximum available power. A fourfold reduction in regulation switch power dissipation was achieved with series-parallel regulation as compared to the usual series-only switching for direct solar array regulation.

Gooder, S. T.↗