Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load management”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Determining and Unlocking Untapped Demand-Side Management Potential in South Africa: Demand Response at the Grid Edge

The National Renewable Energy Laboratory (NREL), funded through the Climate Technology and Change Network (CTCN), has provided technical assistance to key energy sector entities in South Africa to examine untapped demand-side management potential. NREL partnered with the Council for Scientific and Industrial Research (CSIR) and included key South Africa stakeholders: Eskom, the South African National Energy Development Institute (SANEDI), and the Department of Mineral and Resources and Energy (DMRE), including the CTCN National Designated Entity (NDE), the Department of Science and Innovation (DSI). South Africa is currently experiencing an energy crisis with extensive load shedding. While the load shedding crisis in South Africa is a supply side problem, demand-side management provides opportunities to achieve energy efficiency and to reduce peak demand. DSM also has huge potential to help alleviate load shedding, which is a last resort form of DSM.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Energy Conservation Projects to Benefit the Railroad Industry

The Energy Conservation Projects to benefit the railroad industry using the Norfolk Southern Company as a model for the railroad industry has five unique tasks which are in areas of importance within the rail industry, and specifically in the area of energy conservation. The NIU Engineering and Technology research team looked at five significant areas in which research and development work can provide unique solutions to the railroad industry in energy the conservation. (1) Alternate Fuels - An examination of various blends of bio-based diesel fuels for the railroad industry, using Norfolk Southern as a model for the industry. The team determined that bio-diesel fuel is a suitable alternative to using straight diesel fuel, however, the cost and availability across the country varies to a great extent. (2) Utilization of fuel cells for locomotive power systems - While the application of the fuel cell has been successfully demonstrated in the passenger car, this is a very advanced topic for the railroad industry. There are many safety and power issues that the research team examined. (3) Thermal and emission reduction for current large scale diesel engines - The current locomotive system generates large amount of heat through engine cooling and heat dissipation when the traction motors are used to decelerate the train. The research team evaluated thermal management systems to efficiently deal with large thermal loads developed by the operating engines. (4) Use of Composite and Exotic Replacement Materials - Research team redesigned various components using new materials, coatings, and processes to provide the needed protection. Through design, analysis, and testing, new parts that can withstand the hostile environments were developed. (5) Tribology Applications - Identification of tribology issues in the Railroad industry which play a significant role in the improvement of energy usage. Research team analyzed and developed solutions which resulted in friction modification to improve energy efficiency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Performance Evaluation of Counter-Based Dynamic Load Balancing Schemes for Massive Contingency Analysis with Different Computing Environments

Contingency analysis is a key function in the Energy Management System (EMS) to assess the impact of various combinations of power system component failures based on state estimation. Contingency analysis is also extensively used in power market operation for feasibility test of market solutions. High performance computing holds the promise of faster analysis of more contingency cases for the purpose of safe and reliable operation of today’s power grids with less operating margin and more intermittent renewable energy sources. This paper evaluates the performance of counter-based dynamic load balancing schemes for massive contingency analysis under different computing environments. Insights from the performance evaluation can be used as guidance for users to select suitable schemes in the application of massive contingency analysis. Case studies, as well as MATLAB simulations, of massive contingency cases using the Western Electricity Coordinating Council power grid model are presented to illustrate the application of high performance computing with counter-based dynamic load balancing schemes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Linear Quadratic Tracking Design for a Generic Transport Aircraft with Structural Load Constraints

When designing control laws for systems with constraints added to the tracking performance, control allocation methods can be utilized. Control allocations methods are used when there are more command inputs than controlled variables. Constraints that require allocators are such task as; surface saturation limits, structural load limits, drag reduction constraints or actuator failures. Most transport aircraft have many actuated surfaces compared to the three controlled variables (such as angle of attack, roll rate & angle of side slip). To distribute the control effort among the redundant set of actuators a fixed mixer approach can be utilized or online control allocation techniques. The benefit of an online allocator is that constraints can be considered in the design whereas the fixed mixer cannot. However, an online control allocator mixer has a disadvantage of not guaranteeing a surface schedule, which can then produce ill defined loads on the aircraft. The load uncertainty and complexity has prevented some controller designs from using advanced allocation techniques. This paper considers actuator redundancy management for a class of over actuated systems with real-time structural load limits using linear quadratic tracking applied to the generic transport model. A roll maneuver example of an artificial load limit constraint is shown and compared to the same no load limitation maneuver.

Burken, John J.↗

Flexibility Reserve Reductions from an Energy Imbalance Market with High Levels of Wind Energy in the Western Interconnection

The anticipated increase in variable generation in the Western Interconnection (WI) over the next several years has raised concerns about how to maintain system balance, especially in smaller Balancing Areas (BAs). Given renewable portfolio standards in the West, it is possible that more than 50 gigawatts (GW) of wind capacity will be installed by 2020. Significant quantities of solar generationare likely to be added as well. The consequent increase in variability and uncertainty that must be managed by the conventional generation fleet and responsive load make it attractive to consider ways in which Balancing Area Authorities (BAAs) can pool their variability and response resources, thus taking advantage of geographic and temporal diversity to increase overall operational efficiency.Our analysis considers several alternative forms of an Energy Imbalance Market (EIM) that have been proposed in the non-market areas of the WI. The proposed EIM includes two changes in operating practices that independently reduce variability and increase access to responsive resources: BAA cooperation and sub-hourly dispatch. As proposed, the EIM does not consider any form of coordinated unitcommitment; however, over time it is possible that BAAs would develop formal or informal coordination plans. This report examines the benefits of several possible EIM implementations, both separately and in concert.

17 WIND ENERGY↗

The power reliability event simulator tool (PRESTO): A novel approach to distribution system reliability analysis and applications

The growing interest in onsite solar photovoltaic and energy storage systems is partially motivated by customer concerns regarding grid reliability. However, accurately assessing the effectiveness of PVESS in mitigating these interruptions requires a comprehensive understanding of location-specific outage patterns and the ability to simulate realistic scenarios. To address the gap, we introduce the Power Reliability Event Simulation TOol (PRESTO), the first publicly available tool that simulates location-specific power interruptions at the county level. PRESTO allows for a more realistic assessment of system reliability by considering the unpredictability and location-specific patterns of power interruptions. We applied PRESTO in a case study of a single-family home across three U.S. counties, examining the performance of a solar photovoltaic system with 10kWh of battery storage during short-duration power interruptions. Our findings show that this system reliably met 93% of energy demand for essential non-heating and cooling loads, fully serving these loads in 84% of events, despite the constraints of daily time-of-use bill management which limits the battery's state-of-charge reserve. However, when heating and cooling loads were included, system performance decreased significantly, with only 70% of demand met and full service in 43% of events. These results highlight the challenges of using solar photovoltaic and energy storage systems for short-duration outages, emphasizing the need to consider factors like battery size and grid charging strategies to improve reliability. Our study demonstrates the practical applications of PRESTO, providing valuable insights into potential mitigation strategies including grid charging and optimizing battery size.

14 SOLAR ENERGY↗

Modulating thermal load through lightweight residential building walls using thermal energy storage and controlled precooling strategy

Precooling is a recognized technique for reducing cooling energy in buildings during peak hours by shifting load to off-peak hours. This technique is particularly effective in buildings with high thermal mass, because of their large thermal energy storage capacity, and in commercial buildings due to their variable electricity pricing based on time-of-use rates. Precooling in residential buildings has been a matter of limited interest in the past because of their low thermal mass and typically uniform electricity pricing rate. While previous studies on precooling primarily focused on cost savings, an important aspect of precooling is the thermal load modulation, which could be very effective in managing peak demand in lightweight residential buildings integrated with thermal energy storage systems. In this study, we examine different precooling strategies to manage the heat gains in lightweight building walls integrated with phase-change materials. We create nine different precooling profiles by controlling the interior temperature, and then evaluate the influence of the precooling profiles on four key building energy performance parameters: total heat gain, peak heat gain, maximum heat gain during peak hours, and time at which peak occurs. To thoroughly understand the fundamental physics, we first consider hypothetical climates and obtain the optimal precooling strategy required to achieve maximum peak shedding and shifting while minimizing the total heat gains. We then extend the model to Baltimore, Maryland, and estimate the benefits of the optimized precooling strategy under real conditions. The optimal precooling strategy proposed in this study can shift the peak heat gain by up to 14 hours, thereby reducing the heat gain during peak period by up to 95%, at the expense of a 23% increase in the total heat gains.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Weight Optimization of Active Thermal Management Using a Novel Heat Pump

Efficient lightweight power generation and thermal management are two important aspects for space applications. Weight is added to the space platforms due to the inherent weight of the onboard power generation equipment and the additional weight of the required thermal management systems. Thermal management of spacecraft relies on rejection of heat via radiation, a process that can result in large radiator mass, depending upon the heat rejection temperature. For some missions, it is advantageous to incorporate an active thermal management system, allowing the heat rejection temperature to be greater than the load temperature. This allows a reduction of radiator mass at the expense of additional system complexity. A particular type of active thermal management system is based on a thermodynamic cycle, developed by the authors, called the Solar Integrated Thermal Management and Power (SITMAP) cycle. This system has been a focus of the authors research program in the recent past (see Fig. 1). One implementation of the system requires no moving parts, which decreases the vibration level and enhances reliability. Compression of the refrigerant working fluid is accomplished in this scheme via an ejector.

Lear, William E.↗

A Solar Sail Shape Modeling Approach for Attitude Control Design and Analysis

Solar sails operating in the space environment experience deformations in sail shape that result in relatively large disturbance torques which dictate the required performance of the spacecraft attitude control and momentum management systems. These deformations are driven by thermal loads on the booms (due to uneven solar heating), manufacturing and assembly tolerances, and variations in membrane tension. The Solar Cruiser spacecraft utilizes a four-quadrant sail design with four 30-meter length booms and four triangular sail membranes, creating a square sail structure of >1600 m2. Medium-fidelity mesh models were developed based on a characteristic deformed shape. A series of parametric studies were conducted using this shape paradigm to determine worst-case deformed sail shapes which produce bounding disturbance torques. A large database of shapes was produced, and the forces and moments induced by each individual shape were calculated using a Rios-Reyes reduced order generalized sail model. Two were selected as reference worst-case shapes for the Solar Cruiser mission: one which produced the highest pitch/yaw root-sum-squared (RSS) torque, and one which produced the highest roll torque. The results showed that the worst-case shapes at high solar incidence angles induce significantly higher (2-10x) disturbance torques than an ideal, flat-plate sail. Even with considerable safety margins, assuming an ideal sail is unlikely to sufficiently bound the disturbances, which is critical when designing the attitude control system and sizing actuators. Accurate sail shape modeling methodologies should therefore be employed on future solar sail missions.

Solar Sail↗

A Solar Sail Shape Modeling Approach for Attitude Control Design and Analysis

Solar sails operating in the space environment experience deformations in sail shape that result in relatively large disturbance torques which dictate the required performance of the spacecraft attitude control and momentum management systems. These deformations are driven by thermal loads on the booms (due to uneven solar heating), manufacturing and assembly tolerances, and variations in membrane tension. The Solar Cruiser spacecraft utilizes a four-quadrant sail design with four 30-meter length booms and four triangular sail membranes, creating a square sail structure of >1600 m2. Medium-fidelity mesh models were developed based on a characteristic deformed shape. A series of parametric studies were conducted using this shape paradigm to determine worst-case deformed sail shapes which produce bounding disturbance torques. A large database of shapes was produced, and the forces and moments induced by each individual shape were calculated using a Rios-Reyes reduced order generalized sail model [1]. Two were selected as reference worst-case shapes for the Solar Cruiser mission: one which produced the highest pitch/yaw root-sum-squared (RSS) torque, and one which produced the highest roll torque. The results showed that the worst-case shapes at high solar incidence angles induce significantly higher (2-10x) disturbance torques than an ideal, flat-plate sail. Even with considerable safety margins, assuming an ideal sail is unlikely to sufficiently bound the disturbances, which is critical when designing the attitude control system and sizing actuators. Accurate sail shape modeling methodologies should therefore be employed on future solar sail missions. References [1] L. Rios-Reyes and D. J. Scheeres, “Generalized Model for Solar Sails,” Journal of Spacecraft and Rockets, Vol. 42, Jan. 2005, pp. 182–185, 10.2514/1.9054.

Solar Sail↗

Rotorcraft Health Management Issues and Challenges

This paper presents an overview of health management issues and challenges that are specific to rotorcraft. Rotorcraft form a unique subset of air vehicles in that their propulsion system is used not only for propulsion, but also serves as the primary source of lift and maneuvering of the vehicle. No other air vehicle relies on the propulsion system to provide these functions through a transmission system with single critical load paths without duplication or redundancy. As such, health management of the power train is a critical and unique part of any rotorcraft health management system. This paper focuses specifically on the issues and challenges related to the dynamic mechanical components in the main power train. This includes the transmission and main rotor mechanisms. This paper will review standard practices used for rotorcraft health management, lessons learned from fielded trials, and future challenges.

Zakrajsek, James J.↗

Sodium-Cooled Fast Reactor Proliferation Resistance and Physical Protection White Paper

The Sodium-Cooled Fast Reactor (SFR) system was identified during the Generation IV Technology Roadmap as a promising technology to perform the actinide management mission and, if enhanced economics for the system could be realized, also the electricity and heat production missions. The main characteristics of the SFR that make it especially suitable for the actinide management mission are: Consumption of transuranics in a closed fuel cycle, thus reducing the radiotoxicity and heat load which facilitates waste disposal and geologic isolation; Enhanced utilization of uranium resources through efficient management of fissile materials and multi-recycle; and, High level of safety achieved through inherent and passive means that accommodate transients and bounding events with significant safety margins.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Decommissioning of the 247-F Fuel Manufacturing Facility at the Savannah River Site (SRS)

Building 247-F at SRS was a roughly 110,000 ft{sup 2} two-story facility designed and constructed during the height of the cold war naval buildup to provide additional naval nuclear fuel manufacturing capacity in early 1980's. The manufacturing process employed a wide variety of acids, bases, and other hazardous materials. As the need for naval fuel declined, the facility was shut down and underwent initial deactivation, which was completed in 1990. All process systems were flushed with water and drained using the existing process drain valves. However, since these drains were not always installed at the lowest point in piping and equipment systems, a significant volume of liquid remained after initial deactivation. After initial deactivation, a non-destructive assay of the process area identified approximately 17 ({+-}100%) kg of uranium held up in equipment and piping. The facility was placed in Surveillance and Maintenance mode until 2003, when the decision was made to perform final deactivation, and then decommission the facility. The following lessons were learned as a result of the D and D of building 247-F. Successful D and D of a major radiochemical process building requires significant up-front planning by a team of knowledgeable personnel led by a strong project manager. The level of uncertainty and resultant risk to timely, cost effective project execution was found to be high. Examples of the types of problems encountered which had high potential to adversely impact cost and schedule performance are described below. Low level and sanitary waste acceptance criteria do not allow free liquids in waste containers. These liquids, which are often corrosive, must be safely removed from the equipment before it is loaded to waste containers. Drained liquids must be properly managed, often as hazardous or mixed waste. Tapping and draining of process lines is a dangerous operation, which must be performed carefully. The temptation to become complacent when breaking into lines is great. Incidents of personnel exposure to liquids during draining are likely. Records from the initial 1990 deactivation led early work planners to assume the facility was cold, dark and dry. This turned out to be a poor assumption. Work instructions had to be modified to require that engineers evaluate each of several hundred process lines to identify the low point, where a tap and drain system could be installed to allow positive verification that the line was empty before the line was cut for removal. During the period between facility shut down in 1990 and the start of final deactivation in 2003, roof leaks had developed, allowing rain water to enter building 247-F, which provided an environment for mold growth. Sampling confirmed the presence of Stachybotrys chartarum, a toxic indoor mold that grows on wet cellulosic material, such as drywall paper. D and D workers in areas where this hazard was identified were required to where proper personal protective equipment, which complicated work execution. Discovery of the potential presence of uniquely hazardous chemicals such as shock sensitive compounds and toxic uranium hexafluoride became issues which required investigation and special handling strategies. Team access to subject matter experts, who could quickly provide the required guidance for safe material handling, was critical to keeping the project on schedule. In old legacy facilities, it is possible that the D and D workers will be exposed to undocumented energy sources such as energized electrical conductors and pipes containing hazardous materials that originate outside the boundaries of the facility. Significant effort must be expended on adequate mechanical and electrical isolation. Subdividing the facility into well defined zones for which detailed zone-specific end points could be developed proved to be a highly effective project management strategy. Waste management must be carefully planned. The rate of waste generation as the facility is converted from a structure to waste can frequently exceed the D and D team's resources to characterize, package, store and transport the waste to a disposal facility in a timely manner. This can lead to schedule delays and/or increased project cost.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

DOE SNF Packaging Demonstration Project: Worktable and Canister Loading Sleeve Design [Slides]

This presentation is a briefing for summer interns and others outside the project, to give them a summary of ongoing design activities. The DOE SNF Packaging Demonstration Project is an effort to develop and demonstrate the designs, technology, processes, and regulatory framework for packaging DOE-managed spent nuclear fuel (SNF) for road ready dry storage (RRDS). The project is to remotely load and seal two types of DOE-managed SNF from the CPP-603 facility into DOE Standard Canisters, place the sealed DOE Standard Canisters into commercial vendor over-canisters (equivalent to commercial MPCs), seal and place the over-canisters into commercial vendor storage overpacks, and place the storage system (over-canister and storage overpack) onto the CPP-2707 cask pad.

42 ENGINEERING↗

Unnatural hypoxic regimes

Abstract Coastal hypoxia is increasing worldwide in response to human‐caused changes in global climate and biogeochemical cycles. In this paper, we view anthropogenic trends in coastal hypoxia through the lens of disturbance ecology and complexity theory. Complexity theory provides a framework for describing how estuaries and other coastal aquatic ecosystems respond to hypoxia by understanding feedback loops. Can it also be valuable in understanding how these ecosystems behave under shifting (i.e., unnatural) disturbance regimes? When viewed as a disturbance regime, shifts in the spatial (areal extent and fragmentation) and temporal (frequency and duration of events) characteristics of coastal hypoxia can be used to track changes into a non‐stationary future. Here, we consider options for increasing the resilience of coastal aquatic ecosystems to future, unnatural hypoxic regimes. To start, we define desirable states as ecosystems with long trophic chains and slow nutrient and carbon dynamics that produce many ecosystem services. We then work backward to describe circumstances dominated by positive feedbacks that can lead ecosystems toward an undesirable state (i.e., depauperate communities and chemically reduced sediments). Processes of degradation and recovery can be understood in the context of island biogeography whereby species diversity in habitats fragmented by hypoxia is determined by the balance between rapid local extinction, slow recolonization from the edges of hypoxic patches, and opportunities for ecological succession during between disturbance events. We review potential future changes associated with changing global climate and highlight ways to enhance coastal resilience. In addition to efforts to slow climate change, potential interventions include reduced nutrient and carbon loadings from rivers, restoration of aquatic vegetation, and managing for key species, including those that promote sediment oxygenation, that enhance water clarity, or that promote grazing on epiphytic algae through top‐down control.

54 ENVIRONMENTAL SCIENCES↗

The Use of Ultrasound-Guided Injections for Tendinopathies

Purpose of Review: The purpose of the study was to review the efficacy and safety of common ultrasound-guided injections for tendinopathy conditions. Corticosteroid injections have historically been the most common injection used for tendinopathy; however, there are an increasing number of injections including platelet-rich plasma, hyaluronan, polidocanol, botulinum toxin, and high volume saline injections. Recent Findings: There is growing evidence that while corticosteroid injections for tendinopathies usually have short-term efficacy, they may result in medium-term harm, particularly for tennis elbow (lateral epicondylitis). Corticosteroid injections appear to have more clinical utility for tenosynovitis conditions. There is insufficient evidence regarding other injection options to make a broad recommendation in favour, although individual trials for certain tendons illustrate benefits for some of the non-corticosteroid options. Summary: When considering the use of ultrasound-guided corticosteroid injections for tendinopathies, the risk of possible medium-term harm must be weighed up against any short-term efficacy. Other injection-based therapies may be appropriate in certain clinical situations; however, the evidence and clinical circumstances must be considered for the particular tendon and patient. Load-based rehabilitation remains the cornerstone of tendinopathy management.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A reforecasting-based dynamic reserve estimation for variable renewable generation and demand uncertainty

The installed capacity of renewables-based energy sources has been increasing in traditional power systems. In order to accommodate the increased variability and uncertainty associated with the deeper penetration of renewable sources like solar and wind, adjusted amounts of dynamic reserve are needed. Although probabilistic dynamic reserve estimation methods have been previously developed, most of them consider the uncertainty to be represented by parametric density functions that tend to perform poorly under extreme events and, moreover, neglect uncertainty introduced by the forecasting model itself. Toward addressing these limitations, this work presents, for the first time, a dynamic reserve estimation method for flexibility that incorporates nonparametric density estimation and a machine learning based reforecasting to provide a day-ahead prediction of the mean and spread of uncertainty around the base forecast. The prediction is, in turn, used to estimate the up and down reserve relative to the base forecast. Here, the present method takes various endogenous and exogenous features, including the calendar variables, as input to estimate the day-ahead reserve. Using a combination of reforecasting and dynamic reserve estimation techniques, the method is shown to adjust better to the dynamic nature of reserve requirements providing only what is needed to accommodate the expected deviations. Considering California Independent System Operator (CAISO) solar, wind and load data over an 18 month period, up to 67% reduction in the amount of reserve capacity needed for a one day reserve and reserve penalty for solar uncertainty is demonstrated. Additionally, the risk of reserve insufficiency in meeting the net demand is reduced by 20% with the proposed method.

14 SOLAR ENERGY↗

Nepal Himalaya offers considerable potential for pumped storage hydropower

There is a pressing need for a transition from fossil fuel to renewable energy to meet the increasing energy demands and reduce greenhouse gas emissions. The Himalayan region, with its unique topography and abundant water resources, offers substantial renewable energy potential, particularly through hydropower generation. However, the current exploitation rate is low owing to the predominance of run-of-river hydropower systems to support the power system. The utility-scale storage facility is crucial in the load scenario of an integrated power system to manage diurnal variation, peak demand, and penetration of intermittent energy sources. In this study, we assess the potential of pumped storage hydropower across Nepal, a central Himalayan country, under multiple configurations by pairing lakes, rivers, and available flat terrains. We then identify technically feasible pairs from those of potential locations. Infrastructural, environmental, operational, and other technical constraints govern the choice of feasible locations. Here, we show that 42% of the theoretical potential of 3000 GWh is technically feasible. We find the flat land-to-river configuration more promising than other configurations. Our findings provide insight into the potential of pumped storage hydropower and are of practical importance in planning sustainable power systems in the Himalayas and beyond.

13 HYDRO ENERGY↗