Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load balancing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Space Suit Environment Testing of the Orion Atmosphere Revitalization Technology

An amine-based carbon dioxide (CO2) and water vapor sorbent in pressure-swing regenerable beds has been developed by Hamilton Sundstrand and baselined for the Orion Atmosphere Revitalization System (ARS). In three previous years at this conference, reports were presented on extensive Johnson Space Center (JSC) testing of this technology. That testing was performed in a sea-level pressure environment with both simulated and real human metabolic loads, and in both open and closed-loop configurations. The Orion ARS is designed to also support space-suited operations in a depressurized cabin, so the next step in developmental testing at JSC was to test the ARS technology in a typical closed space suit-loop environment with low-pressure oxygen inside the process loop and vacuum outside the loop. This was the first instance of low-pressure, high-oxygen, closed-loop testing of the Orion ARS technology, and it was conducted with simulated human metabolic loads in March 2009. The test investigated pressure drops and flow balancing through two different styles of prototype suit umbilical connectors. General swing-bed performance was tested with both umbilical configurations, as well as with a short jumper line installed in place of the umbilicals. Other interesting results include observations on the thermal effects of swing-bed operation in a vacuum environment and a recommendation of cycle time to maintain acceptable suit atmospheric CO2 and moisture levels.

Button, Amy B.↗

Treadmill Exercise with Increased Body Loading Enhances Post Flight Functional Performance

The goals of the Functional Task Test (FTT) study were to determine the effects of space flight on functional tests that are representative of high priority exploration mission tasks and to identify the key underlying physiological factors that contribute to decrements in performance. Ultimately this information will be used to assess performance risks and inform the design of countermeasures for exploration class missions. We have previously shown that for Shuttle, ISS and bed rest subjects functional tasks requiring a greater demand for dynamic control of postural equilibrium (i.e. fall recovery, seat egress/obstacle avoidance during walking, object translation, jump down) showed the greatest decrement in performance. Functional tests with reduced requirements for postural stability (i.e. hatch opening, ladder climb, manual manipulation of objects and tool use) showed little reduction in performance. These changes in functional performance were paralleled by similar decrements in sensorimotor tests designed to specifically assess postural equilibrium and dynamic gait control. The bed rest analog allows us to investigate the impact of axial body unloading in isolation on both functional tasks and on the underlying physiological factors that lead to decrements in performance and then compare them with the results obtained in our space flight study. These results indicate that body support unloading experienced during space flight plays a central role in postflight alteration of functional task performance. Given the importance of body-support loading we set out to determine if there is a relationship between the load experienced during inflight treadmill exercise (produced by a harness and bungee system) and postflight functional performance. ISS crewmembers (n=13) were tested using the FTT protocol before and after 6 months in space. Crewmembers were tested three times before flight, and on 1, 6, and 30 days after landing. To determine how differences in body-support loading experienced during inflight treadmill exercise impacts postflight functional performance, the loading history for each subject during inflight treadmill (T2) exercise was correlated with postflight measures of performance. Crewmembers who walked on the treadmill with higher pull-down loads had less decrement in postflight postural stability and dynamic locomotor control than those subjects who exercised with lighter loads. These data point to the importance of providing significant body loading during inflight treadmill exercise. This and the addition of specific balance training may further mitigate decrements in critical mission tasks that require dynamic postural stability and mobility. Inflight treadmill exercise provides a multi-disciplinary platform to provide sensorimotor, aerobic and bone mechanical stimuli benefits. Forward work will focus on the development of an inflight training system that will integrate aerobic, resistive and balance training modalities into a single interdisciplinary countermeasure system for exploration class missions.

Bloomberg, J. J.↗

TPCPF: Three-Phase Continuation Power Flow Tool for Voltage Stability Assessment of Distribution Networks With Distributed Energy Resources

This article presents a three-phase unbalanced continuation power flow algorithm for voltage stability assessment of distribution systems with high penetration of distributed energy resources (DERs). Analyzing distribution system voltage stability with DER will allow high penetration of renewable energy necessary for the sustainability goals. The developed algorithm can analyze voltage stability for both the meshed and radial systems and the balanced and unbalanced three-phase distribution systems. The developed tool allows the voltage stability analysis to facilitate the planning, operation, control, and distribution system management. The impact of DER on the voltage stability of several test cases has been analyzed considering constant power (P Q) and regulated-voltage (P V ) modes of operation for DER units. Moreover, different voltage stability case studies are presented to demonstrate the impact of unbalance, load increment, and network topology on the maximum loading capacity. Finally, results using the IEEE 13-node feeder, the 18-bus balanced shipboard system, the 13-node CIGRE benchmark system, and the 136-bus redial distribution feeder demonstrate that the developed continuation power flow tool can efficiently perform voltage stability analysis for active distribution systems.

42 ENGINEERING↗

Report on High-Fidelity Dynamic Modeling of a Coal-Fired Steam Power Plant

As a result of the growth of renewables including solar and wind energy with fluctuating production, fossil fuel power plants are being required to cycle between high and low power production. This cycling is both at a greater frequency and over a wider range than in the past. In many cases, power plants are not designed for this type of cycling operation but can nonetheless endure these challenging operation requirements under the right conditions. In this project, optimal solution for enhanced flexible operations are being investigated using model based estimation and control techniques. To support the development of model-based estimator and model-based controls at GE Global Research, GE Steam Power configured a dynamic model using a reference steam plant design including the boiler, turbine, and water/steam conditioning systems as well as the controls needed for plant cycling with stability and reliability. The dynamic model was built using the APROS® software from VTT, and then calibrated to multiple load conditions from full load (100%TMCR) to partial loads (75%TMCR, 50%TMCR and 25%TMCR) based on internally developed steady state heat balance models at the unit level. These internal heat balance models are based on first principles and extensive engineering experiences from GE Steam Power as an OEM and a services provider. This topical report presents the structure of the unit level dynamic model, the tuning process, and representative simulation results from typical load cycling simulations using the dynamic model.

01 COAL, LIGNITE, AND PEAT↗

Application of Intelligent Load Control to Manage Building Loads to Support Rapid Growth of Distributed Renewable Generation

Electricity utilities are faced with the mounting challenge of providing a stable supply of power to meet the growing demand while also integrating rapid growth in distributed variable renewable generation. Traditional means of balancing short- and long-term supply and demand imbalance will be expensive. Alternative approaches of using flexible loads in buildings are needed to mitigate the imbalance at a lower cost. This paper shows how the intelligent load control (ILC) process can be used to manage loads in buildings by dynamically prioritizing loads for curtailment using both quantitative and qualitative criteria. The ILC process can be deployed on low-cost computing platforms without the need for any additional sensing. ILC was first validated in a simulation environment to provide two grid service use cases: (1) managing monthly peak electricity demand and (2) managing buildings’ electricity consumption during a capacity bidding event. After being successfully tested in a simulation environment, ILC was deployed on real buildings to manage electricity consumption to provide two different use cases under different outdoor operating conditions. Both the simulation tests and the real building experiments were deployed using VOLTTRON™, a distributed sensing and control platform. The results from the tests and experiments showed that ILC was able to manage the controllable loads (heat pumps) in the building to maintain the electricity consumption at the desired level without a significant impact on occupant comfort. Overall, the results demonstrate that the ILC allows coordination of the controllable loads and provides a more intelligent means of load management than the traditional duty-cycling approach.

Kim, Woohyun↗

Pre-Test Assessment of the Upper Bound of the Drag Coefficient Repeatability of a Wind Tunnel Model

A new method is presented that computes a pre{test estimate of the upper bound of the drag coefficient repeatability of a wind tunnel model. This upper bound is a conservative estimate of the precision error of the drag coefficient. For clarity, precision error contributions associated with the measurement of the dynamic pressure are analyzed separately from those that are associated with the measurement of the aerodynamic loads. The upper bound is computed by using information about the model, the tunnel conditions, and the balance in combination with an estimate of the expected output variations as input. The model information consists of the reference area and an assumed angle of attack. The tunnel conditions are described by the Mach number and the total pressure or unit Reynolds number. The balance inputs are the partial derivatives of the axial and normal force with respect to all balance outputs. Finally, an empirical output variation of 1.0 microV/V is used to relate both random instrumentation and angle measurement errors to the precision error of the drag coefficient. Results of the analysis are reported by plotting the upper bound of the precision error versus the tunnel conditions. The analysis shows that the influence of the dynamic pressure measurement error on the precision error of the drag coefficient is often small when compared with the influence of errors that are associated with the load measurements. Consequently, the sensitivities of the axial and normal force gages of the balance have a significant influence on the overall magnitude of the drag coefficient's precision error. Therefore, results of the error analysis can be used for balance selection purposes as the drag prediction characteristics of balances of similar size and capacities can objectively be compared. Data from two wind tunnel models and three balances are used to illustrate the assessment of the precision error of the drag coefficient.

drag coefficient measurement↗

Nontraditional Approaches To Enable High-Energy and Long-Life Lithium–Sulfur Batteries

In this study, lithium-sulfur (Li-S) batteries are promising for automotive applications due to their high theoretical energy density (2600 Wh/kg). In addition, the natural abundance of sulfur could mitigate the global raw material supply chain challenge of commercial lithium-ion batteries that use critical elements, such as nickel and cobalt. However, due to persistent polysulfide shuttling and uncontrolled lithium dendrite growth, Li-S batteries using nonencapsulated sulfur cathodes and conventional ether-based electrolytes suffer from rapid cell degradation upon cycling. Despite significant improvements in recent decades, there is still a big gap between lab research and commercialization of the technology. To date, the reported cell energy densities and cycling life of practical Li-S pouch cells remain largely unsatisfactory. Traditional approaches to improving Li-S performance are primarily focused on confining polysulfides using electronically conductive hosts. However, these micro- and mesoporous hosts suffer from limited pore volume to accommodate high sulfur loading and the associated volume change during cycling. Moreover, they fail to balance adsorption-conversion of polysulfides during charge-discharge, leading to the formation of massive dead sulfur. Such hosts are themselves electrochemically inactive, which decreases the practical energy density. In contrast, a series of nontraditional approaches, paired with advances in multiscale mechanistic understanding, have recently demonstrated exciting performance outcomes not only in conventional coin cells but also in practical pouch cells. In this Account, we first introduce our novel cathode design strategies to overcome polysulfide shuttling and sluggish redox kinetics in thick S cathodes via selenium-sulfur chemistry and cathode host engineering. Next, we gain a mechanistic understanding of Li-S batteries in various types of electrolytes via a series of spectroscopic, nuclear magnetic resonance, and electrochemical methods. Meanwhile, a novel cathode solid electrolyte interphase encapsulation strategy via nonviscous highly fluorinated ether-based electrolyte is introduced. The established selection rule by investigating how solvating power retards the shuttle effect and induces robust cathode/solid-electrolyte interphase formation is also included. We then discuss how the synergistic interactions between rational cathode structures and electrolytes can be exploited to tailor the reaction pathways and kinetics of S cathodes under high mass loading and lean electrolyte conditions. In addition, a novel interlayer design to simultaneously overcome degradation processes (polysulfide shuttling and lithium dendrite formation) and accelerate redox reaction kinetics is presented. Finally, this Account concludes with an overview of the challenges and strategies to develop Li-S pouch cells with high practical energy density, long cycle life, and fast-charging capability.

25 ENERGY STORAGE↗

Mapping the combustion modes of a dual-fuel compression ignition engine

Compression-ignition (CI) engines can produce higher thermal efficiency (TE) and thus lower carbon dioxide (CO 2 ) emissions than spark-ignition (SI) engines. Unfortunately, the overall fuel economy of CI engine vehicles is limited by their emissions of nitrogen oxides (NO x ) and soot, which must be mitigated with costly, resource- and energy-intensive aftertreatment. NO x and soot could also be mitigated by adding premixed gasoline to complement the conventional, non-premixed direct injection (DI) of diesel fuel in CI engines. Several such “dual-fuel” combustion modes have been introduced in recent years, but these modes are usually studied individually at discrete conditions. This paper introduces a mapping system for dual-fuel CI modes that links together several previously studied modes across a continuous two-dimensional diagram. This system includes the conventional diesel combustion (CDC) and conventional dual-fuel (CDF) modes; the well-explored advanced combustion modes of HCCI, RCCI, PCCI, and PPCI; and a previously discovered but relatively unexplored combustion mode that is herein titled “Piston-split Dual-Fuel Combustion” or PDFC. Tests show that dual-fuel CI engines can simultaneously increase TE and lower NO x and/or soot emissions at high loads through the use of Partial HCCI (PHCCI). At low loads, PHCCI is not possible, but either PDFC or RCCI can be used to further improve NO x and/or soot emissions, albeit at slightly lower TE. These results lead to a “partial dual-fuel” multi-mode strategy of PHCCI at high loads and CDC at low loads, linked together by PDFC. Drive cycle simulations show that this strategy, when tuned to balance NO x and soot reductions, can reduce engine-out CO 2 emissions by about 1% while reducing NO x and soot by about 20% each with respect to CDC. This increases emissions of unburnt hydrocarbons (UHC), still in a treatable range (2.0 g/kWh) but five times as high as CDC, requiring changes in aftertreatment strategy.

Engineering↗

Inverter Controls for Smooth Transition Operation and Voltage Balancing of Networked Microgrids

With increasing penetrations of distributed energy resources (DERs), researchers have extensively studied the formation and networking of microgrids to improve reliability during distribution system outages. However, these operations might require DERs in the microgrids to switch between grid-following (GFL) and grid-forming (GFM) modes of operation. A smooth transition between the operation modes should be ensured to have a stable system operation and to avoid nuisance tripping. Additionally, as we network microgrids, inverter control schemes with voltage-balancing controls are needed for unbalanced distribution networks. This paper presents the design of a GFM and GFL capable inverter control scheme for reliable operation in networked microgrids with mechanisms for 1) smooth transition between the GFL and GFM modes, and 2) negative sequence voltage control for voltage balancing. Using electromagnetic transient (EMT) simulations, the control scheme is first tested on a simple two-source power system using a digital real-time simulator. Next, a real-world distribution feeder with unbalanced loading and multiple DERs is used to demonstrate stable operation during the networking of microgrids with voltage balance support.

distributed energy resources↗

Loads and Structural Dynamics Requirements for Spaceflight Hardware

The NASA Exploration Systems Development Mission Directorate requires Crewed Space Systems (CSS) to meet the intent of a set of Engineering Technical Authority (TA) documents called out in HEOMD-003, Crewed Deep Space Systems Human Rating Certification Requirements and Standards for NASA Missions. For the Loads and Dynamics technical discipline, the document invoked by the HEOMD-003 is JSC 65829, Loads and Structural Dynamics Requirements for Spaceflight Hardware. JSC 65829 was originally developed for the NASA Commercial Crew Program as an implementation of NASA STD-5002, Load Analyses of Spacecraft and Payloads, for that Program. Since that time, tailored alternatives to JSC 65829 have been produced for the Gateway, Human Landing System, and Extravehicular Activity and Human Surface Mobility Programs. Experience with those Programs has shown that the reduced set of less-prescriptive requirements in those tailored documents offers an advantage over the set of requirements in JSC 65829 Rev A and is a better fit for the paradigm of NASA procurement of commercially developed systems for crewed spaceflight. Revision B of JSC 65829 has been constructed to align with those tailored documents. The reduction in the number and specificity of requirements is balanced by a new requirement for hardware developers to create and provide a Loads Control Plan which describes how the approaches used to generate design-to loads and dynamic environments and substantiate dynamic model validity satisfy the requirements herein. The Plan will establish an agreement between the hardware developer and the TA for the loads and dynamics discipline and offer an opportunity for reengagement if the Plan changes during development.

Kenneth Schultz↗

Investigation of a Helicopter Individual Blade Control (IBC) System in Two Full-Scale Wind Tunnel Tests: Volume I

This report presents the data acquired during the testing of an individual blade control (IBC) system on a full-scale helicopter rotor in two test entries in the NASA Ames 40- by 80-Foot Wind Tunnel. The objective of these investigations was to evaluate the potential benefits of using IBC to improve rotor performance, reduce blade vortex interaction (BVI) noise, and alleviate helicopter vibrations. The wind tunnel tests were an international, collaborative effort between NASA, the U.S. Army Aeroflightdynamics Directorate, ZF Luftfahrttechnik GmbH, Eurocopter Deutschland GmbH, and the German Aerospace Laboratory (DLR). They were conducted as a task of the U.S./German Memorandum of Understanding (MOU) on Helicopter Aeromechanics. The IBC tests were performed using a full-scale BO-105 helicopter rotor mounted to the NASA/U.S. Army Rotor Test Apparatus (RTA). The first test, performed in 1993, was the first full-scale wind tunnel test to explore the effects of an IBC system on rotor vibration, noise, and performance. In this test, the pitch links of the rotor were replaced by servo-actuators. The servo-actuators and IBC control system were designed and manufactured by ZF Luftfahrttechnik GmbH. This control system allowed the pitch of each rotor blade to be changed independently of the other blades. The IBC inputs had large effects on the hub vibrations and BVI noise. However, the rotor hub moments were not retrimmed with each new IBC input. This resulted in an out-of-trim rotor configuration. The same IBC system was used in the second IBC test performed in 1994. This test more carefully investigated the potential of IBC to simultaneously reduce noise and vibration and also investigated the effect of IBC on rotor performance in high-speed-cruise flight. In the 1994 test, the hub moment and rotor thrust were readjusted to maintain rotor trim as the IBC inputs were applied. For this reason, the data taken from the second test are considered to be more accurate, except for some unique IBC input combinations not repeated in the second test. IBC controls that were evaluated were single-frequency inputs from 2/rev to 6/rev and multi-harmonic combinations of these frequencies to form pulses, wavelets, and doublets. Extensive data were acquired for each IBC data point. These data included rotor performance, average and time-varying hub loads, rotor blade bending loads, control system loads, inboard and outboard blade pitch motions, and BVI noise data. The rotor balance hub force and moment data included the mean values, half-peak-to-peak values, and sine/cosine harmonics up to the 20th rotor harmonic. The time history and averaged Fourier spectrum for each measurement are available electronically from NASA Ames Research Center. The data indicate that significant reduction in both BVI noise and hub vibration can be obtained using IBC. The 2/rev input produced the best single-frequency results. At a typical descent flight condition, 2/rev IBC combined with other IBC harmonics reduced the BVI noise up to 12 dB (85 percent) at some microphone locations. At the same time, this input could also reduce the dominant 4/rev vibratory hub loads by up to 75 percent. The data also show that performance improvements of up to 7 percent were obtained using 2/rev IBC at high-speed forward flight conditions. An analysis of the hydraulic power requirements for BVI noise suppression, vibration reduction, and rotor performance improvement is included in this report. This analysis shows that the power required by the IBC system is negligible at low-speed flight conditions, and that a net gain of 3 percent of rotor horsepower can be achieved at high-speed flight conditions.

Investigation↗

Demonstration of a Novel Technology to Manage Electricity Demand in Grid-Independent Military Microgrids

This research was conducted by the National Renewable Energy Laboratory (NREL) in collaboration with the S&C Electric Inc. through funding provided by the ESTCP. The project demonstrates use of cybersecure Automated Demand Response (ADR) technology to effectively manage microgrid loads during grid-independent, also known as "islanded," operation. When military microgrids become isolated from the main electrical grid, they are required to balance electricity supply and demand locally. Given that local generation may be constrained, the prevailing strategy involves shedding all but the most critical loads by tripping smart circuit breakers, which then necessitate manual resetting. This approach is generally implemented at the building level, which means that the buildings with mission-critical activities are exempt from load management and remain fully powered, whereas those deemed non-critical can experience a complete loss of service. In this research we developed a method that allows building automation systems to selectively control their assets in response to load shedding request from a microgrid controller, avoiding total loss of service in contrast to the conventional control approach. A commercial OpenADR client server by GridFabric is used for communication between the microgrid controller and the building management system (BMS). The microgrid controller monitors both generation capacity and various assets within the microgrid and issues a demand reduction request when necessary. This request is communicated to the OpenADR server via Modbus. Upon receiving the request, the OpenADR server forwards it to the BMS utilizing the OpenADR protocol. The BMS is pre-configured with various levels of load reduction strategies based on the controllable assets available, allowing for a nuanced approach to demand reduction. Both lab and field tests were performed that considered load shedding needed to achieve closed transition into island mode and to accommodate changing loads and power source availability while islanded. A commercial microgrid controller was used for these tests with normal programming within the expected constraints of the system capabilities. That is, the solution did not require any specialized modification to the code base of the controller. Given the latency of the round-trip communication path between the microgrid controller and the various devices involved with the load shed processes, there are certain scenarios for which the demonstrated solution are appropriate and some which are not. The methods described in this report can be used for load shedding/restoration during transitions between islanded and grid-tied modes of operation, as well as accommodating normal variations in load and the need to remove a power source from operation for maintenance. These methods should not be used for scenarios that require load shedding within a second or two such as sudden and unanticipated significant load increases or loss of power sources through equipment faults.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Antarctic Rebound and the Time-Dependence of the Earth's Shape

Great strides have been made during the past 30 years in refining models of the last global glaciation. The refinements draw upon a vastly expanded relative sea level and sedimentary core record. Furthermore, we now possess a sharpened understanding of the mechanisms that drive climate changes associated with deglaciation. Some 15 years ago, using only 5.5 years of ranging data, analyses of the drift in LAGEOS I node acceleration was used to infer that postglacial rebound was responsible for a secular change in the Earth's ellipsoidal shape (Yoder et al., .1983]. Today there exists a wealth of geodynamics satellite orbit data that constrain the secular time-dependence of the Earth's shape and low order gravity field, which includes mass redistribution from present-day glacier and great ice sheet imbalance and from postglacial rebound. We have shown that an unambiguous determination of the secular variation in the Earth's pear shaped harmonic (l = 3, m = 0) might provide information that bears on the present-day mass balance of Antarctica. This issue is revisited in light of new constraints on glacial loading during the late-Pleistocene and Holocene. An especially critical issue for the interpretation of secular odd degree zonal harmonics, l = 3 to 7, is the timing and magnitude of the deglaciation of Antarctica from Last Glacial Maximum. We explore ways in which the recovery of secular variation in both zonal and non-zonal harmonics for l = 2 through 7 can improve constraints on both rebound and present-day ice sheet balance.

Ivins, Erik R.↗

Comparative modeling reveals the molecular determinants of aneuploidy fitness cost in a wild yeast model

Although implicated as deleterious in many organisms, aneuploidy can underlie rapid phenotypic evolution. However, aneuploidy will be maintained only if the benefit outweighs the cost, which remains incompletely understood. To quantify this cost and the molecular determinants behind it, we generated a panel of chromosome duplications in Saccharomyces cerevisiae and applied comparative modeling and molecular validation to understand aneuploidy toxicity. We show that 74%–94% of the variance in aneuploid strains’ growth rates is explained by the cumulative cost of genes on each chromosome, measured for single-gene duplications using a genomic library, along with the deleterious contribution of small nucleolar RNAs (snoRNAs) and beneficial effects of tRNAs. Machine learning to identify properties of detrimental gene duplicates provided no support for the balance hypothesis of aneuploidy toxicity and instead identified gene length as the best predictor of toxicity. Our results present a generalized framework for the cost of aneuploidy with implications for disease biology and evolution.

genic load↗

Production of Gaseous Olefins from Syngas over a Cobalt-HZSM-5 Catalyst

Light olefins (C2–C5) are high-value platform chemicals used to produce plastics, lubricants, coating material, and surfactants, and can be intermediates to produce transportation fuels. In this study we report on the development of a Co-based catalyst for direct conversion of fossil as well as biomass derived syngas into light olefins that enables high conversion and olefin/paraffin (O/P) product ratio, minimal selectivity to CO2 (<?1%) and wax formation (C14+ selectivity?<?1%). Over a Co/HZSM-5 bi-functional catalyst 38% CO conversion with C2–C5 olefin selectivity of 48%, and O/P ratio of 4.0 was achieved at 240 °C, 17 bar, and 1.5 L/(g–h). In addition to a gaseous olefin-rich stream a C6–C13 mixed olefin/paraffin liquid byproduct was also produced with 25% selectivity. Both Co loading and the HZSM-5 acidity levels were optimized to maintain the balance between the hydrogenation and the cracking activity to generate high levels of C2–C4 olefins. A suite of catalyst characterization tools were used to correlate the physical and chemical property of the catalyst to the performance of the catalyst towards syngas conversion and C2–C4 olefin selectivity.

Maddi, Balakrishna↗

A real-time distributed solid oxide electrolysis cell (SOEC) model for cyber-physical simulation

System integration and dynamic operability between SOEC and balance-of-plant (BoP) components are major technical challenges before realizing rapid load following of SOEC systems. Cyber-physical simulation (CPS) is a leading-edge digital engineering approach and is regarded as the next step beyond Digital Twins. CPS approach can be used to research SOEC system integration and develop dynamic controls prior to actual pilot testing without using a real SOEC. To seamlessly couple with BoP hardware and access non-observable operational parameters (e.g., local temperature gradient) during transients, a distributed one-dimensional (1D) real-time SOEC model was developed. Its real-time execution was demonstrated for 20 to 640 nodes at the fixed time step of 5 ms. A higher excess air ratio enabled smaller local temperature gradients on SOEC solid materials and faster transients upon current density step change from 0.15 to 0.55 A cm -2 . During the transients, the magnitude of the peak temperature gradient nearly doubled in 10 s from -3.5 to -5.9 °C cm -1 . This represents a significant operating risk that can impact the dynamic operability of SOEC systems. In addition, the local temperature gradient was found to change directions on all nodes in SOEC solid materials, with the greatest impact on the upstream nodes. The SOEC model was also tested at the thermal neutral voltage using actual process air flow parameters as variable model inputs. Variable process air temperatures were found to induce alternating local temperature gradients on SOEC solid materials. These are new operational mechanisms for SOEC degradation relevant for load following operational modes yet distinct from previous reports. To mitigate these unfavorable features, the SOEC can be operated at voltages that are slightly (±20 mV) deviated from the thermal neutral voltage. Here, the corresponding net thermal energy change was less than 1.6% of the electric power consumption. This 1D real-time SOEC model established the basis of cyber-physical simulation of SOEC hybrid systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Performance of Polymer Electrolyte Membrane Water Electrolysis Systems: Configuration, Stack Materials, Turndown and Efficiency

A cell model is developed and validated to analyze the performance of polymer electrolyte membrane water electrolysis (PEMWE) stacks and systems. It is used to characterize the oxygen evolution reaction (OER) activity on a TiO2-supported IrO2 catalyst and an unsupported IrO2 powder catalyst. Electrochemical, stack, and system thermoneutral potentials are defined and determined for isothermal and non-isothermal stack operation. Conditions are determined under which the system thermoneutral potential or flammability of H2 in the O2 anode stream limits the stack turndown and operating temperature. Performance is analyzed of a complete PEMWE system with an electrolyzer stack containing an IrO2/TiO2 anode catalyst (2 mg/cm2 Ir loading) and N117-like membrane mitigated for H2 crossover, anode balance-of-plant (BOP) components, cathode BOP system with temperature swing adsorption for H2 purification, and electrical BOP system with transformer and rectifier. At the rated power condition, defined as 2 A/cm2 at 1.9 V, 80 °C, and 30 bar H2 pressure, the stack/system efficiency is 65.3%/60.3% at beginning of life (BOL), decreasing to 59.3%/53.9% at end of life (EOL). The peak stack/system efficiency is 76.3%/70.2% at BOL, decreasing to 71.2%/65.6% at EOL. Improvements in catalyst activity and membrane are identified for a 50% increase in current to 3 A/cm2 at 1.8 V.

36 MATERIALS SCIENCE↗

A model of heat transfer in immersed man

An equation representing man's thermal balance under water is considered. The equation states that the body thermal loading from metabolic heat production and artificial heat input must be offset by respiratory and environmental heat exchange to maintain a constant body temperature. Critical body regions are affected by cold-water thermal stress. A model of the thermoregulatory system may be divided into the physical-controlled system and the dynamic controlling system. The thermal model is simulated by computer programs.

Montgomery, L. D.↗