Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “kW”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

P2M Simulation Exercise on Past Fuel Melting Irradiation Experiments

This paper presents the results of the Power To Melt and Maneuverability (P2M) Simulation Exercise on past fuel melting irradiation experiments, organized within the Organisation for Economic Co-operation and Development/Nuclear Energy Agency Framework for IrraDiation ExperimentS (FIDES) framework by the Core Group (CEA, EDF, and SCK·CEN) and open to all FIDES members. The exercise consisted in simulating two past power ramps where fuel melting was detected: (1) the xM3 staircase power transient [ramp terminal level (RTL) 70 kW·m -1 , average burnup 27 GWd·tU -1 ], carried out in 2005 in the R2 reactor at Studsvik (Sweden), where the rodlet maintained its integrity, and (2) the HBC4 fast power transient (RTL 66 kW·m -1 , average burnup 48 GWd·tU -1 ), carried out in 1987 in the BR2 reactor at SCK·CEN (Belgium), where the cladding failed during the experiment. The exercise was joined by 13 organizations from 9 countries using 11 different fuel performance codes. In this paper, the main results of the Simulation Exercise are presented and compared to available postirradiation examinations (PIE) or on-line measurements during the power ramps (fuel and clad diameters, rod elongation, pellet-clad gap, and fission gas release). Since the focus of the Simulation Exercise is on fuel melting assessment, determination of the boundary between melted/nonmelted fuel and the consequent definition of a melting radius from PIE are first discussed. During the HBC4 ramp, fuel melting was predicted by most of the codes despite differences in the melting models. Higher discrepancies were observed for the xM3 rod that can be attributed partly to power uncertainty and partly to the limited capability of the models to describe partial melting of the fuel during this ramp. Finally, possible code developments to improve simulation results are presented.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Progress towards 28 GHz operations at the Facility for Rare Isotope Beams (FRIB)

This paper provides an overview on the design, operational parameters as well as recent development and recent performance, of the superconducting electron cyclotron resonance (ECR) ion source at the Facility for Rare Isotope Beams (FRIB). The ion source has been used in support of beam operations since the end of 2022 and was designed to operate at 28 GHz and be capable of delivering high intensity uranium beams to help support beam delivery of up to a final beam power of 400 kW. Currently operating at up to 20 kW many primary beams have been developed and routinely used with the superconducting ECR including uranium. Initially operated at 18 GHz, the ion source has now been coupled to a 28 GHz gyrotron and high intensity beams have been demonstrated ahead of the facility planned power ramp up. text with the article abstract. Replace this text with the article abstract.

Machicoane, G. A. [Michigan State University, East↗

Emissivity measurements of CuCrZr alloy

The Facility for Rare Isotope Beams (FRIB) heavy-ion accelerator, in user operation since 2022, produces rare isotope beams via interactions of high-intensity stable ion beams with a graphite production target. Approximately 20–40% of the primary beam power is deposited in the target, while the remaining 60–80% is absorbed by the beam dump. The minichannel beam dump (MCBD), currently operated at 20 kW and designed for operation up to 50 kW, uses CuCrZr alloy absorber plates. Thermal validation and thermal cycling tests of the MCBD were conducted at the Applied Research Laboratory (ARL) at Pennsylvania State University. Temperature measurements were obtained from an infrared (IR) camera. Since accurate temperature determination requires reliable emissivity values, the emissivity of CuCrZr was measured using the IR camera validated against thermocouple reference temperatures up to approximately 650 °C. The measurements were conducted under a vacuum level of approximately 10 -5 torr to minimize emissivity variations due to surface oxidation. The emissivity of CuCrZr was determined to be 0.057 ± 0.009 using a constant fit to the measured data over the surface temperature range from 100–650 °C.

Accelerator Subsystems and Technologies↗

LCLS-II helium cryoplant and cryo distribution system installation

The helium cryoplant and cryo distribution system (CDS) are key elements of the new superconducting Linac Coherent Light Source (LCLS-II) and will provide superfluid helium to the accelerator. The cryoplant consists of two helium refrigerators with an equivalent 4.5 K refrigeration capacity of 18 kW each. The 37 cryomodules of the LINAC will be operated at a temperature of 2.0 K to accelerate a 4 GeV electron beam that will generate extremely bright X-ray laser light. Two five-stage cold compressor cold boxes will be utilized to provide superfluid helium II for the superconducting cavity structures with a total cooling capacity of 8 kW at 2.0 K. This paper describes the installation of the LCLS-II cryoplant and CDS. The LCLS-II cryoplant was designed and contributed by Jefferson Lab. To expedite the project completion the reuse of proven design and technology from the Jefferson Lab CHL-2 cryoplant was the preferred strategy. The CDS consists of ~260 m thermally shielded and vacuum super insulated transfer lines, two distribution boxes and eight feed and end caps, and was designed and contributed by Fermilab. SLAC installed the cryoplant components into a newly erected building and the CDS components into the existing accelerator tunnel and klystron gallery with strong engineering support from both partner labs.

43 PARTICLE ACCELERATORS↗

Design of the cryogenic moderator system for the second target station

The Second Target Station (STS) at Oak Ridge National Laboratory will be a 700 kW pulsed spallation neutron source designed to provide the world's highest brightness cold neutron beams. In order to produce the required neutron performance, two compact liquid hydrogen moderators are located adjacent to the tungsten spallation target and must be supplied with less than 20 K hydrogen and a para hydrogen fraction of 99.8% or greater. The Cryogenic Moderator System (CMS) will consist of a single hydrogen loop feeding the two moderators in series cooled by a helium refrigerator with a cooling capacity of 2.5 kW at 17 K. The hydrogen loop consists of a hydrogen circulator, hydrogen helium heat exchanger, ortho-para converter, accumulator, transfer lines and heater. The design of the hydrogen loop is based on the CMS design of the First Target Station at the Spallation Neutron Source and some of the component designs may be reused. General hydrogen temperature control is provided by controlling the flowrate of helium to the heat exchanger. The hydrogen loop will have a constant flowrate of 0.5 L/s and remove a nuclear heat load of about 850 W from the two moderators, which is deposited both directly in the hydrogen and the adjacent hydrogen containing structures. Because the nuclear heat load is accelerator driven, the hydrogen system must remain stable when the heat load is removed instantaneously during beam trips. System stability is maintained passively with the accumulator and actively with the heater. Ionizing radiation which interacts with the liquid hydrogen drives backconversion of the hydrogen from parahydrogen to orthohydrogen. The STS moderator performance is very sensitive to small fractions of orthohydrogen requiring an ortho-para converter to maintain the hydrogen supplied to the moderators at near equilibrium parahydrogen concentration. STS CMS is in the early stage of preliminary design and current focus is evaluating component sizing and system stability during beam transients.

Janney, Jim↗

LCLS-II Helium Refrigeration System Commissioning Results

SLAC National Accelerator Laboratory has upgraded to LCLS-II, featuring a 4 GeV superconducting linear accelerator composed of 37 cryomodules and two large helium refrigeration systems with a cooling capacity of 4 kW at 2.0 K. The LCLS-II Helium Refrigeration System (HRS) consists of two compressor stations, each with a power of approximately 4.5 MW, two 4.5 K cold boxes, each with a power of 18 kW equivalent at 4.5 K, and two sets of cold compressors that can each produce a flow of 230 g/s at 31 mbar (2.0K). Performance tests of the HRS were meticulously planned and successfully carried out, with results demonstrating that it exceeded the process requirements for LCLS-II operations. This paper provides a detailed presentation of the LCLS-II HRS performance and the challenges encountered during the commissioning phase.

42 ENGINEERING↗

Performance Testing of the 4kW ESR 2 Refrigerator at JLab

Abstract The End Station Refrigerator 2 (ESR2), a refurbished cryoplant, will replace the ESR1. ESR2 is comprised of the cold box and compressors from the Superconducting Super Collider’s 4 kW, 4.5 K ASST-A plant. It also features a new 10 kL liquid helium dewar, a cryogenic distribution system and new control and utility systems. This plant was reconfigured to provide a cold helium supply at 15 K, 12 K, and 8 K for the experimental hall’s hydrogen targets. The most significant load will be during the MOLLER experiment, which will see a total hydrogen target load of 5 kW at 15 K. This paper details the commissioning results of the 4.5 K refrigeration system in various modes (maximum refrigeration, maximum liquefaction, and a 50/50 mix) at both 100 % and 50 % capacity. We will also evaluate the performance with an expected MOLLER load. Current performance will be compared with the historical commissioning data from the ASST-A plant.

Perry, C. [Cryogenics Department, Thomas Jefferson↗

Observation of New Isotopes in the Fragmentation of Pt 198 at FRIB

Five previously unknown isotopes ( 182,183 Tm, 186,187 Yb, 190 Lu) were produced, separated, and identified for the first time at the Facility for Rare Isotope Beams (FRIB) using the Advanced Rare Isotope Separator (ARIS). The new isotopes were formed through the interaction of a 198 Pt beam with a carbon target at an energy of 186 MeV/u and with a primary beam power of 1.5 kW. Event-by-event particle identification of A, Z, and q for the reaction products was performed by combining measurements of the energy loss, time of flight, magnetic rigidity Bρ, and total kinetic energy. The ARIS separator has a novel two-stage design with high resolving power to strongly suppress contaminant beams. Finally, this successful new isotope search was performed less than one year after FRIB operations began and demonstrates the discovery potential of the facility which will ultimately provide 400 kW of primary beam power.

07 ISOTOPE AND RADIATION SOURCES↗

Modular Isolated Soft-Switching Medium Voltage String Inverter for Large-Scale PV Farm

This paper presents a single-stage modular isolated soft-switching medium voltage string inverter (MVSI) with tri-port configuration to interconnect PV and storage to medium voltage (MV) grid. The modular MVSI provides advanced functionalities such as energy storage elements integration without additional converters, connection to MV grid resulting in lower distribution losses in the PV farm, high-frequency galvanic isolation, independent control of PV, storage and grid power, high modularity and scalability. The topology of the MVSI, operation principle and model-predictive priority-switching (MPPS) control to achieve fast dynamic balancing across stacked modules are discussed. The independent power control is validated in PLECS simulation and the operation of stacked MVSI with MPPS control is verified through Hardware-in-the-loop (HIL) simulation. Here, the hardware prototype of 25 kVA MVSI building block is developed. 18 kW experimental results of single building block verifying tri-ports operation and 20 kW experimental results of two modules stacked operation are presented. A clean sinusoidal waveform with negligibly low THD in both tests is obtained. A low dv/dt of <; 1kV/us and soft-switching are achieved.

30 DIRECT ENERGY CONVERSION↗

A Novel Bi-directional AC/DC - DC/AC Wireless Power Transfer System for Grid Support Applications

The severity of the economic impact caused by grid outages has been the driving factor for creating innovative solutions that increases interest for the deployment of distributed energy resources to reduce the impact of grid outages. This paper presents a novel topology for providing export power applications. Proposed topology can be used for grid (primary)-side of bi-directional wireless power transfer (WPT) systems, mobile energy storage systems (ESSs), and electric vehicle (EV) batteries. The proposed concept here achieves energy transfer between sources by using a hybrid frequency bi-directional ac/dc converter without an additional front-end converter stage compared to the conventional systems. Due to inherent merit of the proposed bi-directional ac/dc converter, ac input with 60 Hz grid frequency can be directly transferred through the wireless coils and can be directly converted to the dc. Results demonstrate the performance and the functionality of the single-phase bi-directional system with the input / output of 110 V ac,rms and 200 V dc at 1 kW power. Full paper will demonstrate the converter operation at 10 kW power level with additional features and control aspects.

Asa, Erdem↗

A Novel Three-Phase Oak Ridge AC / AC Converter for Wireless Mobility Energy Storage System (WMESS) Connectivity

In this study, a novel three-phase Oak Ridge ac to ac converter is introduced for wireless mobility energy storage system (WMESS) applications for grid support or ancillary service applications. The proposed topology can be used in bidirectional operation between ac grid and ac terminals of energy storage (output of the ESS inverter) by accomplishing unity power factor. Inherent merit of the technology is that it can directly merge ac input 60 Hz grid frequency with the high frequency by superimposing them with the Oak Ridge Converter (ORC) and through the wireless coils. Theoretical and simulation results are provided for 10 kW output power. The functionality of the proposed three-phase system is demonstrated with the coupling coils separated by 6 inches of air gap with the input / output of 277 V AC,RMS . The system overall design is presented, and simulation results demonstrate achieving 3% current total harmonic distortion (THD) and 0.99 power factor (PF) at full load of 10 kW wireless power transfer.

Asa, Erdem↗

A 1MHz Oak Ridge AC / DC Converter for UAV Contactless Charger Implementation

In this paper, a 1 MHz single-phase Oak Ridge Converter (ORC) AC/DC wireless power transfer (WPT) system is introduced for unmanned air vehicle (UAV) charging applications. The proposed advanced solution eliminates the design, weight, volume, and the cost of the power factor correcting (PFC) front-end rectifier compared to the conventional practices. Additionally, grid power quality requirements can be achieved with the presented innovative idea. With this method, single stage WPT primary side uses the hybrid grid frequency and high frequency (60 Hz and 1 MHZ) from ac source through the coupler coils and to UAV battery with GaN FETs. Experimental results of the single-phase system is presented to confirm the mathematical analyses with the source voltage of 110 VAC, RMS and output voltage of 40 VDC at 1 kW power with 6 inches air gap between couplers. The primary coupler consists of a ferrite-backed single-turn coil with a radius of 1.5 ft, and the secondary coupler is made with an air-core single-turn coil with radius of 1.2 ft. The system overall ac to dc efficiency is measured 77 % acquiring 0.99 power factor (PF) and 3.3 % current total harmonic distortion (THD) at 1 kW power.

Asa, Erdem↗

Design and Optimization of High-frequency Transformer for Isolated Single-Stage Three-Phase AC/DC Converter using Bidirectional Switches

This paper presents the design and optimization of the high-frequency transformer for an isolated single-stage threephase AC/DC converter enabled by the 4H-SiC BiDirectional Field Effect Transistor (BiDFET). Non-dominated Sorting Genetic Algorithm II (NSGA-II) is used to perform a multiobjective optimization to minimize loss, weight, and volume. A 20 kW, 50 kHz hardware prototype based on the selected optimal point is characterized by a power amplifier. The finite element analysis simulation results are also presented to validate the core magnetic flux density and winding electric field strength. The experimental prototype was tested at 800 Vdc/480 Vrms at 10 kW rated power.

BiDFET, High-frequency transformer, Multiobjective↗

Balancing Charging Station Utilization and Throughput in Electric Vehicle Charging Stations with Queuing Theory

The rapid increase in electric vehicle (EV) adoption demands enhancements in the efficiency and adaptability of EV supply equipment (EVSE). Traditional EVSE systems often fail to optimize power delivery to meet the variable acceptance rates of EV batteries, resulting in significant energy wastage and reduced operational efficiency. This research addresses these challenges by integrating queuing theory with modular EVSE architectures, offering a dual strategy to optimize the operation of EV charging stations. A simulation model was developed to assess various configurations of charger capacities and outlet numbers. This model aimed to identify the optimal setup that maximizes station utilization while minimizing charging times and maximizing throughput. The model focused on charger capacities ranging from 50 to 250 kW and analyzed the different capacities’ effects on charging times and the number of vehicles served. The results indicate that a charger capacity of 125 kW is optimal, striking a balance between the charging time and the number of EVs served per hour, thus achieving the highest station utilization rate. This capacity allows for servicing a significant number of EVs with moderate increases in charging times. Lower capacities, although capable of serving more vehicles, lead to longer charging times and decreased throughput efficiency. The study underscores the effectiveness of combining queuing theory with flexible, modular charging systems that can dynamically adjust to EV charging demands.

Kumar, Praveen↗

PHIL Interface Design for Use With a Voltage-Regulated Amplifier

Power hardware-in-the-loop (PHIL) has emerged as a leading strategy to thoroughly assess the impact of proprietary inverter controls on a specific power system. The development of a PHIL test bed typically involves an inverter under test, a power amplifier, controllable DC supply, and a digital real-time simulator (DRTS) to simulate the power system under study. As a result of PHIL nonidealities, a form of digital compensation within the DRTS is used, which is commonly referred to as a PHIL interface. Many existing methods use legacy power amplifiers that do not contain internal voltage regulation. These existing interface methods are based around a voltage regulator within the DRTS and do not consider the interaction with the controls in newer amplifiers. In this study, a three-step approach of PHIL interface development for modern power amplifiers with built-in voltage regulation is introduced and is validated in hardware with a 30-kW grid-following inverter.

DRTS↗

A Tradeoff Analysis of Series / Parallel Three-Phase Converter Topologies for Wireless Extreme Chargers

In this paper, extreme fast charging (XFC) technology is studied considering the charge rates of 300 kW for wireless power transfer (WPT) applications. Tradeoff analysis of series and parallel connection of three-phase WPT system are presented by comparisons of voltage and current stresses on power electronics active / passive components. In addition, star (Y) / delta (Δ) connection configurations for three-phase wireless power transfer coupling coils are analyzed with series and LCC resonant compensation circuits. The system series and parallel connection controllability is also reviewed considering voltage and current balance techniques with output control. In a conclusion of evaluation analysis, it is revealed that each component of 300 kW wireless charging network must be designed for high fast charging system and the overall system operation need to be strategically planned for high power charging and infrastructure deployment.

Asa, Erdem↗

Comparison of Magnetic Field Emission from Unipolar and Bipolar Coil-Based Wireless Charging Systems

In this study, the leakage magnetic field (LMF) from the unipolar (circular, rectangular, etc.) and bipolar (double-D) coil-based wireless charging systems (WCSs) are investigated and compared. The unipolar and bipolar pads, which are the two most widely adopted charging-pads, have significantly different magnetic field emission characteristics. In this paper, the spatial-distribution and vector-pattern of the leakage magnetic field are studied and compared for similar 11 kW unipolar and bipolar coil-based WCSs. The field emissions are simulated using finite element analysis (FEA) and tested experimentally with an 11 kW bipolar coil-based WCS prototype. The results show that the leakage magnetic field of the unipolar and bipolar pads have widely different vector-orientation and spatial distributions of the leakage magnetic field. The results show that the unipolar coil based WCS has a dominant vertical and the bipolar pads coil-based WCS has dominant horizontally aligned leakage magnetic field. Considering the shielding, the aluminum plate is found highly effective for the unipolar pad and almost ineffective for bipolar pads.

Mohammad, Mostak↗

A Novel Three Phase Oak Ridge DC / AC Converter for Wireless Grid Tied Applications

In this study, a novel three phase oak ridge dc to ac converter is introduced for wireless mobility energy storage (WMES) applications to support the grid demand during peak times. The proposed topology can be used in a bi-directional operation between ac grid and dc terminals of energy storage by accomplishing unity power factor. Inherent merit of the technology can directly merge dc input to the high frequency and 60 Hz grid frequency by superimposing through the wireless coils. Theoretical and simulation results are validated by the simulation analysis for 20 kW output power. The functionality of the proposed three phase system is established by using 6 inches air gap between the couplers with the input of 675 V DC and output of 277 V AC, RMS . The system overall design analysis is demonstrated for simulation analysis and simulation results are presented achieving 3% current total harmonic distortion (THD) and 0.99 power factor (PF) at full load 20 kW wireless power transfer.

Asa, Erdem↗