Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “interference”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Rapid analysis of 237 Np and Pu isotopes in unseparated sample matrices using ICP-MS/MS

Inductively coupled plasma tandem mass spectrometry (ICP-MS/MS) is an emerging technique for measuring actinide isotopes when assessing pre- and post- detonation nuclear material. In this study, ICP-MS/MS was investigated for direct Np and Pu quantitation in unseparated, dissolved bulk soil matrices. To achieve this, purified nitric oxide (NO) was investigated for the reactivity of Th, Np, U, Pu, Am, and Cm. Purifying NO prior to the collision reaction cell (CRC) results in increased sensitivity and allows for higher gas flows to be utilized for the removal of interferences. Here, the interference from uranium hydrides was mitigated to less than 3.85 x 10 -11 . This method was demonstrated on standard reference materials which were measured for 237 Np and 238,239,240 Pu in dilute sample digestions. The 238 Pu measurement was validated by spiking into a standard reference material and was accurately measured with an excess of 85000 of 238 U.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Assessing Gas-Phase Ion Reactivity of 50 Elements with NO and the Direct Application for 239 Pu in Complex Matrices Using ICP-MS/MS

Understanding the reactivity of metal cations with various reaction gases in ICP-MS/MS is important to determine the best gas to use for a given analyte/interference pair. In this study, nitric oxide (NO) was investigated as the reaction gas following previous experimental designs. The reactions with 50 elements were investigated to examine periodic trends in reactivity, validate theoretical modeling of reaction enthalpies as a method to screen reactant gases, and provide a baseline for potential in-line gas separation methods. ICP-MS/MS studies involving actinides are typically limited to Th, U and Pu, with analyses of Np and Am rarely reported in the literature. To date, only two previous methods have investigated the use of NO in ICP-MS/MS analyses. To showcase the utility of NO, a method was developed to measure 239 Pu in the presence of environmental matrix constituent and other actinides, like what could be expected from post-detonation debris, with no chemical separation prior to analysis. 239 Pu + was reacted to form 239 Pu 16 O + , eliminating interferences derived from the sample matrix by measuring 239 Pu + intensity at m/z = 255 ( 239 Pu 16 O + ). To validate NO for 238 U 1 H + interference removal in environmental matrices, standard reference materials were diluted to 1 mg per gram of solution and spiked to 0.05 pg/g of 239 Pu and 1 µg/g 238 U (Pu/U = 5 x 10 -8 ). Measured 239 Pu concentrations were within 6% of the spiked value. In conclusion, these results demonstrate that reliable 239 Pu measurements can be made at levels relevant to nuclear forensics without the need for extensive chemical matrix separation prior to analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TMTpro Complementary Ion Quantification Increases Plexing and Sensitivity for Accurate Multiplexed Proteomics at the MS2 Level

Multiplexed proteomics is a powerful tool to assay cell states in health and disease, but accurate quantification of relative protein changes is impaired by interference from co-isolated peptides. Most widely, this issue is alleviated by MS3-based quantification, reducing sensitivity and requiring specialized instrumentation. An alternative approach is quantification by complementary ions, which allows accurate and precise multiplexed quantification at the MS2 level and is compatible with the most widely distributed instruments. However, complementary ions of the popular TMT tag form inefficiently and plexing is limited to five channels. In this work, we evaluate and optimize complementary ion quantification for the recently released TMTPro tag, which increases plexing capacity to 8 channels (TMTProC). We find that the beneficial fragmentation properties increase quantification signal five-fold compared to TMT. This increased sensitivity results in ~50% more proteins quantified compared to TMTPro-MS3 and even slightly outperforms TMTPro-MS2. Furthermore, TMTProC quantification is more accurate than TMTPro-MS2 and even superior to TMTPro-MS3. To demonstrate the power of TMTProC, we analyzed a human and yeast interference sample and were able to quantify 13,290 proteins in 24 fractions. Thus, TMTProC advances multiplexed proteomics data quality and widens access to accurate multiplexed proteomics beyond laboratories with MS3-capable instrumentation.

59 BASIC BIOLOGICAL SCIENCES↗

Tuning Hybrid exciton–Photon Fano Resonances in Two-Dimensional Organic–Inorganic Perovskite Thin Films

As easy-to-grow quantum wells with narrow excitonic features at room temperature, two-dimensional (2D) Ruddleson–Popper perovskites are promising for realizing novel nanophotonic devices based on exciton–photon interactions. Here, we demonstrate a distinct hybrid exciton–photon Fano resonance in (C 4 H 9 NH 3 ) 2 PbI 4 thin films prepared via spin coating. Using a classical coupled-oscillator model and finite-difference time-domain simulations, we link the Fano interference to the coupling of the exciton with the Rayleigh-like scattering of the film microstructure. Combining colloidal plasmonic cavities with the 2D perovskite films, we demonstrate tuning of the Fano resonance. In combination with silver nanoparticles, the exciton–photon Fano interference couples to the in-plane plasmonic modes with indications of Rabi splitting. By creating a nanoparticle on mirror geometry, we address the out-of-plane excitonic component, reaching an intermediate coupling regime. Furthermore, these structures suggest possible photonic targets for biomolecular self-assembly applications.

2D perovskites↗

Estimation of the formation rates of polyatomic species of heavy metals in plutonium analyses using a multicollector ICP-MS with a desolvating nebulizer

The analyses of IAEA and environmental samples for Plutonium isotopic content are conducted normally at very low concentrations of Pu–usually in the range of part per trillion level and even more often at the parts per quadrillion level. To analyze such low concentrations, the interferences in the analytical solution must be reduced as much as possible. Polyatomic interferences (PIs), formed by the heavy metals (HMs) from Hf to Bi are known to create the problems for Pu isotopic analyses, because even the relatively high resolution of a modern multicollector ICP-MS is not enough to separate Pu isotopes from this PIs in most of the cases. Desolvating nebulizers (DSN) (e.g. APEX and AridusII) reduce significantly the formation of PIs compare to the use of wet plasma. The purpose of this work was to investigate the rate of formation of PIs, produced by HMs, when high resolution MC ICP-MS with desolvating nebulizer was used for Pu isotopic analyses and to estimate the influence of the metals present in the sample on the results of analyses. The NU Plasma HR Multicollector and AridusII desolvating nebulizer were used in this investigation. This investigation was done for all Pu isotopes normally analyzed by ICP-MS, including ²⁴⁴Pu, with the exception of ²³⁸Pu, which most of the time can’t be analyzed by ICP-MS, because of the overwhelming presence of ²³⁸U in the solutions. The PI formation rates were determined and reported for all 12 HMs from Hf to Bi. Selected IAEA samples were scanned for the presence of HMs and the influence of HMs on the results of Pu isotopic analyses was evaluated. It was found that the implemented separation procedure provides sufficient separation of HM from Pu, although the effect of PIs on the measurement of low level isotopes like ²⁴¹Pu and ²⁴²Pu in some cases can still be observed.

nebulizer↗

Constrained γZ correction to parity-violating electron scattering

We update the calculation of γZ interference corrections to the weak charge of the proton. We show how constraints from parton distributions, together with new data on parity-violating electron scattering in the resonance region, significantly reduce the uncertainties on the corrections compared to previous estimates.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Fano-type transmission and field enhancement in heterostructures composed of epsilon-near-zero materials and truncated photonic crystals

The Fano-type interference effect is studied in the heterostructure composed of an epsilon-near-zero (ENZ) material and a truncated photonic crystal for transverse magnetic polarized light. In the Fano-type interference effect, the ENZ material provides narrow reflection pathway and the photonic crystal provides broadband reflection pathway. The boundary condition across the ENZ interface and the confinement effect provided by the photonic crystal can enhance the electric fields in the ENZ material greatly. The field enhancements, together with the asymmetric property of Fano-type spectrum, possess potential applications for significantly lowering the threshold of nonlinear processes such as optical switching and bistability.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Coherent microscopy at resolution beyond diffraction limit using post-experimental data extrapolation

Conventional microscopic records represent intensity distributions whereby local sample information is mapped onto local information at the detector. In coherent microscopy, the superposition principle of waves holds; field amplitudes are added, not intensities. This non-local representation is spread out in space and interference information combined with wave continuity allows extrapolation beyond the actual detected data. Established resolution criteria are thus circumvented and hidden object details can retrospectively be recovered from just a fraction of an interference pattern.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Merged vector gratings recorded in a photocrosslinkable polymer liquid crystal film for polarimetry

A merged vector grating, which is holographically fabricated in an anisotropic medium by irradiation with interference light with intensity modulation and polarization modulation, was designed to detect the polarization of light. The merged vector grating is recorded by the interference of two elliptically polarized beams with equal intensities, parallel azimuths, equal ellipticities, and different directions of rotation. We clarified theoretically that the Stokes parameters of the incident light beam are described by the diffraction efficiency of the merged vector grating. Also, to apply this property to formation of a polarimeter without any moving parts or mechanisms, two merged vector gratings with different grating vectors were recorded in a photocrosslinkable polymer liquid crystal film by angle-multiplexed holography. By investigation of the diffraction properties of the gratings obtained, we demonstrated the applicability of the merged vector gratings for use in polarimetry.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Acoustical “transparency” induced by local resonance in Bragg bandgaps

We show that sound waves can resonantly transmit through Bragg bandgaps in an acoustical duct periodically attached with an array of Helmholtz resonators, forming within the normally forbidden band a transparency window with group velocity smaller than the normal speed of sound. The transparency occurs for the locally resonant frequency so much close to the Bragg one that both the local-resonance-induced bandgap and the Bragg one heavily overlap with each other. The phenomenon seems an acoustical analog of the well-known electromagnetically induced transparency by quantum interference. Different from the Fano-like interference explanation, we also provide a mechanism for the transparency window phenomenon which makes it possible to extend the phenomenon in general.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Robust random number generation using steady-state emission of gain-switched laser diodes

We demonstrate robust, high-speed random number generation using interference of the steady-state emission of guaranteed random phases, obtained through gain-switching a semiconductor laser diode. Steady-state emission tolerates large temporal pulse misalignments and therefore significantly improves the interference quality. Using an 8-bit digitizer followed by a finite-impulse-response unbiasing algorithm, we achieve random number generation rates of 8 and 20 Gb/s, for laser repetition rates of 1 and 2.5 GHz, respectively, with a ±20% tolerance in the interferometer differential delay. We also report a generation rate of 80 Gb/s using partially phase-correlated short pulses. In relation to the field of quantum key distribution, our results confirm the gain-switched laser diode as a suitable light source, capable of providing phase-randomized coherent pulses at a clock rate of up to 2.5 GHz.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Soft x-ray backlighting of cryogenic implosions using a narrowband crystal imaging system (invited)

A high-performance cryogenic DT inertial confinement fusion implosion experiment is an especially challenging backlighting configuration because of the high self-emission of the core at stagnation and the low opacity of the DT shell. High-energy petawatt lasers such as OMEGA EP promise significantly improved backlighting capabilities by generating high x-ray intensities and short emission times. A narrowband x-ray imager with an astigmatism-corrected bent quartz crystal for the Si He{sub α} line at ∼1.86 keV was developed to record backlit images of cryogenic direct-drive implosions. A time-gated recording system minimized the self-emission of the imploding target. A fast target-insertion system capable of moving the backlighter target ∼7 cm in ∼100 ms was developed to avoid interference with the cryogenic shroud system. With backlighter laser energies of ∼1.25 kJ at a 10-ps pulse duration, the radiographic images show a high signal-to-background ratio of >100:1 and a spatial resolution of the order of 10 μm. The backlit images can be used to assess the symmetry of the implosions close to stagnation and the mix of ablator material into the dense shell.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coherence of a spin-polarized electron beam emitted from a semiconductor photocathode in a transmission electron microscope

The brightness and interference fringes of a spin-polarized electron beam extracted from a semiconductor photocathode excited by laser irradiation are directly measured via its use in a transmission electron microscope. The brightness was 3.8 × 10{sup 7 }A cm{sup −2 }sr{sup −1} for a 30-keV beam energy with the polarization of 82%, which corresponds to 3.1 × 10{sup 8 }A cm{sup −2 }sr{sup −1} for a 200-keV beam energy. The resulting electron beam exhibited a long coherence length at the specimen position due to the high parallelism of (1.7 ± 0.3) × 10{sup −5 }rad, which generated interference fringes representative of a first-order correlation using an electron biprism. The beam also had a high degeneracy of electron wavepacket of 4 × 10{sup −6}. Due to the high polarization, the high degeneracy and the long coherence length, the spin-polarized electron beam can enhance the antibunching effect.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analysis of double-probe characteristics in low-frequency gas discharges and its improvement

The double-probe has been used successfully in radio-frequency discharges. However, in low-frequency discharges, the double-probe I-V curve is so much seriously distorted by the strong plasma potential fluctuations that the I-V curve may lead to a large estimate error of plasma parameters. To suppress the distortion, we investigate the double-probe characteristics in low-frequency gas discharge based on an equivalent circuit model, taking both the plasma sheath and probe circuit into account. We discovered that there are two primary interferences to the I-V curve distortion: the voltage fluctuation between two probe tips caused by the filter difference voltage and the current peak at the negative edge of the plasma potential. Consequently, we propose a modified passive filter to reduce the two types of interference simultaneously. Experiments are conducted in a glow-discharge plasma (f = 30 kHz) to test the performance of the improved double probe. The results show that the electron density error is reduced from more than 100% to less than 10%. The proposed improved method is also suitable in cases where intensive potential fluctuations exist.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Non-spectroscopic surface plasmon sensor with a tunable sensitivity

We demonstrate a non-spectroscopic surface plasmon sensor with a tunable sensitivity which is based on the relationship between the wave number of surface plasmon polaritons (SPPs) on metal film and the refractive index of the specimen in contact with the metal film. A change in the wave number of the SPPs results in a variation in the propagation angle of the leakage radiation of the SPPs. A reference light is used to interfere with the leakage radiation, and the refractive index of the specimen can be obtained by measuring the period of the interference fringes. The sensitivity of the sensor can be tuned by changing the incident direction of the reference light and this cannot be realized by conventional surface plasmon sensors. For a reference angle of 1.007°, the sensitivity and resolution of the sensor are 4629 μm/RIU (RIU stands for refractive index unit) and 3.6 × 10{sup −4} RIU, respectively. In addition, the sensor only needs a monochromatic light source, which simplifies the measurement setup and reduces the cost.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A continuous cold atomic beam interferometer

We demonstrate an atom interferometer that uses a laser-cooled continuous beam of {sup 87}Rb atoms having velocities of 10–20 m/s. With spatially separated Raman beams to coherently manipulate the atomic wave packets, Mach–Zehnder interference fringes are observed at an interference distance of 2L = 19 mm. The apparatus operates within a small enclosed area of 0.07 mm{sup 2} at a bandwidth of 190 Hz with a deduced sensitivity of 7.8×10{sup −5} rad/s/√(Hz) for rotations. Using a low-velocity continuous atomic source in an atom interferometer enables high sampling rates and bandwidths without sacrificing sensitivity and compactness, which are important for applications in real dynamic environments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reconfigurable and ultra-sensitive in-line Mach-Zehnder interferometer based on the fusion of microfiber and microfluid

A reconfigurable Mach-Zenhnder interferometer (MZI) based on a microfluidic cavity (MFC) constructed by embedding a microfiber between two segments of single-mode fibers with pre-designed lateral offset has been proposed and experimentally demonstrated. The MFC serves as an interference arm with an eccentric annular cross section and allows convenient sample (gas or liquids) replacement procedure. The microfiber works as the other interference arm that provides the proposed device with ease of reconstruction and also enhances the force sensitivity. The re-configurability and the ultra-wide tuning sensitivity range are demonstrated by immersing the MZI constructed with a 484 μm-long-MFC and a microfiber 44 μm in diameter in different droplets. Ultrahigh sensitivities of 34.65 nm/°C (∼88 380 nm/RIU) and −493.7 nm/N (∼−590 pm/με) are experimentally achieved using a droplet with a refractive index of ∼1.44.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Surface plasmons at the Brillouin zone boundary of an oblique lattice

In periodic systems of low-symmetry, the Bragg condition for the complete interference of waves along the contour of the Brillouin zone (BZ) boundary is not generally satisfied. As a result, band-gaps do not necessarily occur at this boundary. This letter demonstrates this experimentally by recording the iso-frequency contours for surface plasmon polaritons (SPPs) supported on a diffraction grating with an underlying 2D oblique Bravias lattice. It is shown that these contours do not intersect the BZ boundary perpendicularly, as the symmetry operations of the lattice place no conditions on the surface wave interference at this boundary.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗