Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “imaging systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

A spatio-temporal detective quantum efficiency and its application to fluoroscopic systems

Purpose: Fluoroscopic x-ray imaging systems are used extensively in spatio-temporal detection tasks and require a spatio-temporal description of system performance. No accepted metric exists that describes spatio-temporal fluoroscopic performance. The detective quantum efficiency (DQE) is a metric widely used in radiography to quantify system performance and as a surrogate measure of patient ''dose efficiency.'' It has been applied previously to fluoroscopic systems with the introduction of a temporal correction factor. However, the use of a temporally-corrected DQE does not provide system temporal information and it is only valid under specific conditions, many of which are not likely to be satisfied by suboptimal systems. The authors propose a spatio-temporal DQE that describes performance in both space and time and is applicable to all spatio-temporal quantum-based imaging systems. Methods: The authors define a spatio-temporal DQE (two spatial-frequency axes and one temporal-frequency axis) in terms of a small-signal spatio-temporal modulation transfer function (MTF) and spatio-temporal noise power spectrum (NPS). Measurements were made on an x-ray image intensifier-based bench-top system using continuous fluoroscopy with an RQA-5 beam at 3.9 {mu}R/frame and hardened 50 kVp beam (0.8 mm Cu filtration added) at 1.9 {mu}R/frame. Results: A zero-frequency DQE value of 0.64 was measured under both conditions. Nonideal performance was noted at both larger spatial and temporal frequencies; DQE values decreased by {approx}50% at the cutoff temporal frequency of 15 Hz. Conclusions: The spatio-temporal DQE enables measurements of decreased temporal system performance at larger temporal frequencies analogous to previous measurements of decreased (spatial) performance. This marks the first time that system performance and dose efficiency in both space and time have been measured on a fluoroscopic system using DQE and is the first step toward the generalized use of DQE on clinical fluoroscopic systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Dual Polarization, Active, Microstrip Antenna for an Orbital Imaging Radar System Operating at L-Band

A highly successful Earth orbiting synthetic antenna aperture radar (SAR) system, known as the SIR-C mission, was carried into orbit in 1994 on a U.S. Shuttle (Space Transportation System) mission. The radar system was mounted in the cargo bay with no need to fold, or in any other way reduce the size of the antennas for launch. Weight and size were not limited for the L-Band, C-Band, and X-Band radar systems of the SIR-C radar imaging mission; the set of antennas weighed 10,500 kg, the L-Band antenna having the major share of the weight. This paper treats designing an L-Band antenna functionally similar to that used for SIR-C, but at a fraction of the cost and at a weight in the order of 250 kg. Further, the antenna must be folded to fit into the small payload shroud of low cost booster rocket systems. Over 31 square meters of antenna area is required. This low weight, foldable, electronic scanning antenna is for the proposed LightSAR radar system which is to be placed in Earth orbit on a small, dedicated space craft at the lowest possible cost for an efficient L- Band radar imaging system. This LightSAR spacecraft radar is to be continuously available for at least five operational years, and have the ability to map or repeat-map any area on earth within a few days of any request. A microstrip patch array, with microstrip transmission lines heavily employed in the aperture and in the corporate feed network, was chosen as the low cost approach for this active dual-polarization, 80 MHz (6.4%) bandwidth antenna design.

Kelly, Kenneth C.↗

A Dual Polarization, Active, Microstrip Antenna for an Orbital Imaging Radar System Operating at L-Band

A highly successful Earth orbiting synthetic antenna aperture radar (SAR) system, known as the SIR-C mission, was carried into orbit in 1994 on a U.S. Shuttle (Space Transportation System) mission. The radar system was mounted in the cargo bay with no need to fold, or in any other way reduce the size of the antennas for launch. Weight and size were not limited for the L-Band, C-Band, and X-Band radar systems of the SIR-C radar imaging mission; the set of antennas weighed 10,500 kg, the L-Band antenna having the major share of the weight. This paper treats designing an L-Band antenna functionally similar to that used for SIR-C, but at a fraction of the cost and at a weight in the order of 250 kg. Further, the antenna must be folded to fit into the small payload shroud of low cost booster rocket systems. Over 31 square meters of antenna area is required. This low weight, foldable, electronic scanning antenna is for the proposed LightSAR radar system which is to be placed in Earth orbit on a small, dedicated space craft at the lowest possible cost for an efficient L-Band radar imaging system. This LightSAR spacecraft radar is to be continuously available for at least five operational years, and have the ability to map or repeat-map any area on earth within a few days of any request. A microstrip patch array, with microstrip transmission lines heavily employed in the aperture and in the corporate feed network, was chosen as the low cost approach for this active dual-polarization, 80 MHz (6.4%) bandwidth antenna design.

Kelly, Kenneth C.↗

Conceptual design study for an advanced cab and visual system, volume 1

A conceptual design study was conducted to define requirements for an advanced cab and visual system. The rotorcraft system integration simulator is for engineering studies in the area of mission associated vehicle handling qualities. Principally a technology survey and assessment of existing and proposed simulator visual display systems, image generation systems, modular cab designs, and simulator control station designs were performed and are discussed. State of the art survey data were used to synthesize a set of preliminary visual display system concepts of which five candidate display configurations were selected for further evaluation. Basic display concepts incorporated in these configurations included: real image projection, using either periscopes, fiber optic bundles, or scanned laser optics; and virtual imaging with helmet mounted displays. These display concepts were integrated in the study with a simulator cab concept employing a modular base for aircraft controls, crew seating, and instrumentation (or other) displays. A simple concept to induce vibration in the various modules was developed and is described. Results of evaluations and trade offs related to the candidate system concepts are given, along with a suggested weighting scheme for numerically comparing visual system performance characteristics.

Rue, R. J.↗

High-performance passive microwave survey on Josephson Junctions

The quasi-optical generations of images of objects with their internal structure in millimeter (MM) and submillimeter (SMM) bands is one of prime problems of modern radioelectronics. The main advantage of passive MM imaging systems in comparison with visible and infrared (IR) systems is small attenuation of signals in fog, cloud, smoke, dust and other obscurants. However, at a panoramic scanning of space the observation time lengthens and thereby the information processing rate becomes restricted so that single-channel system cannot image in real time. Therefore we must use many radiometers in parallel to reduce the observation time. Such system must contain receiving sensors as pixels in multibeam antenna. The use of Josephson Junctions (JJ) for this purpose together with the cryoelectronic devices like GaAs FET (field effect transistors) or SQUIDS for signal amplifications after JJ is of particular interest in this case.

Denisov, A. G.↗

Quantitative density visualization in a transonic compressor rotor

The flow in a 59-cm-diameter high-work transonic compressor rotor has been visualized using a fluorescent gas, 2,3, butanedione, as a tracer. The technique allows the three-dimensional flow to be imaged as a set of distinct planes. Quantitative static density maps were obtained by correcting the images for distortion and nonlinearities introduced by the illumination and imaging systems. These images and maps were used to analyze the three-dimensional nature of the blade's boundary layer and shock system.

Epstein, A. H.↗

Use of an automatic procedure for determination of classes of land use in the Teste Araras area of the peripheral Paulist depression

An evaluation of the multispectral image analyzer (system Image 1-100), using automatic classification, is presented. The region studied is situated. The automatic was carried out using the maximum likelihood (MAXVER) classification system. The following classes were established: urban area, bare soil, sugar cane, citrus culture (oranges), pastures, and reforestation. The classification matrix of the test sites indicate that the percentage of correct classification varied between 63% and 100%.

Dejesusparada, N.↗

Image compression system and method having optimized quantization tables

A digital image compression preprocessor for use in a discrete cosine transform-based digital image compression device is provided. The preprocessor includes a gathering mechanism for determining discrete cosine transform statistics from input digital image data. A computing mechanism is operatively coupled to the gathering mechanism to calculate a image distortion array and a rate of image compression array based upon the discrete cosine transform statistics for each possible quantization value. A dynamic programming mechanism is operatively coupled to the computing mechanism to optimize the rate of image compression array against the image distortion array such that a rate-distortion-optimal quantization table is derived. In addition, a discrete cosine transform-based digital image compression device and a discrete cosine transform-based digital image compression and decompression system are provided. Also, a method for generating a rate-distortion-optimal quantization table, using discrete cosine transform-based digital image compression, and operating a discrete cosine transform-based digital image compression and decompression system are provided.

Ratnakar, Viresh↗

Visualization of local phosphatidylcholine synthesis within hippocampal neurons using a compartmentalized culture system and imaging mass spectrometry

Highlights: • A compartmentalized neuron culture system was combined with imaging mass spectrometry. • Phosphatidylcholine (PC) species within rat hippocampal neurons were visualized. • Differential synthetic activity of a PC species within neurons was observed. • Neurites synthesized a PC species using local extracellular free fatty acids in situ. Neurons extend neurites with an increased synthesis of phosphatidylcholine (PC) that is not only a membrane component but also a functional regulator with specific fatty acid composition. To analyze the local synthesis of the PC molecular species within neurons, we combined a compartmentalized culture system with matrix-assisted laser desorption/ionization imaging mass spectrometry (MALDI-IMS). We observed that a newly synthesized PC, which contains exogenously administered palmitic acid-d{sub 3}, is accumulated at the cell bodies and the tips of the distal neurites. The local accumulation within distal neurites is formed by distinct metabolic activity from cell bodies, suggesting that the local extracellular composition of free fatty acid can be a key to regulate specific functions of each PC molecular species. We expect our simple method to be a starting point for more sophisticated in vitro analytical methods for unveiling detailed lipid metabolisms within neurons.

60 APPLIED LIFE SCIENCES↗

Computational Ghost Imaging for Remote Sensing

This work relates to the generic problem of remote active imaging; that is, a source illuminates a target of interest and a receiver collects the scattered light off the target to obtain an image. Conventional imaging systems consist of an imaging lens and a high-resolution detector array [e.g., a CCD (charge coupled device) array] to register the image. However, conventional imaging systems for remote sensing require high-quality optics and need to support large detector arrays and associated electronics. This results in suboptimal size, weight, and power consumption. Computational ghost imaging (CGI) is a computational alternative to this traditional imaging concept that has a very simple receiver structure. In CGI, the transmitter illuminates the target with a modulated light source. A single-pixel (bucket) detector collects the scattered light. Then, via computation (i.e., postprocessing), the receiver can reconstruct the image using the knowledge of the modulation that was projected onto the target by the transmitter. This way, one can construct a very simple receiver that, in principle, requires no lens to image a target. Ghost imaging is a transverse imaging modality that has been receiving much attention owing to a rich interconnection of novel physical characteristics and novel signal processing algorithms suitable for active computational imaging. The original ghost imaging experiments consisted of two correlated optical beams traversing distinct paths and impinging on two spatially-separated photodetectors: one beam interacts with the target and then illuminates on a single-pixel (bucket) detector that provides no spatial resolution, whereas the other beam traverses an independent path and impinges on a high-resolution camera without any interaction with the target. The term ghost imaging was coined soon after the initial experiments were reported, to emphasize the fact that by cross-correlating two photocurrents, one generates an image of the target. In CGI, the measurement obtained from the reference arm (with the high-resolution detector) is replaced by a computational derivation of the measurement-plane intensity profile of the reference-arm beam. The algorithms applied to computational ghost imaging have diversified beyond simple correlation measurements, and now include modern reconstruction algorithms based on compressive sensing.

Erkmen, Baris I.↗

Multi-aperture optical system for high-resolution imaging

Technologies pertaining to a multi-aperture optical imaging system are described herein. The multi-aperture optical system comprises an afocal optical telescope and a plurality of sub-apertures that receive light from the telescope. Each sub-aperture comprises a focusing optic that creates a full-field image onto an individual image sensor that outputs data indicative of an intensity of light received at the sensor. Image processing techniques can be used to combine the sensor outputs for spectral discrimination, to improve dynamic range or to enhance resolution of a scene.

47 OTHER INSTRUMENTATION↗

Digital snow mapping technique using LANDSAT data and General Electric IMAGE 100 system

In this study, a technique and procedures using General Electric IMAGE 100 system were derived for performing a snow cover analysis of small watersheds for quasi-operational application. The study area was the Wind River Mountains of west central Wyoming. A small watershed, namely, Dinwoody Creek was selected as a test site. LANDSAT data and U-2 imagery were used in the analysis. From a minimal snowcover LANDSAT scene, multispectral analysis was performed yielding the distribution of forest, bare rock, grassland, water, and snow within the watershed. The forest and bare rock themes were saved and registered with other scenes containing greater snow cover. Likewise, elevation contours from a digitized map were stored and superimposed over the snowpack areas.

Dallam, W. C.↗

Evidence of Recent Material Transport within a Binary Asteroid System

Images acquired by the Double Asteroid Redirection Test (DART) before its impact into Dimorphos—the moon of the Didymos binary asteroid system—unexpectedly reveal a set of discontinuous rays spanning the imaged surface. These albedo features are visible only after correcting for lighting differences, which normalize the effects of the pervasive boulders that cover the surface. Comparison to physical experiments and numerical simulations shows that these bright, fan-shaped albedo features are consistent with the aftermath of a low-velocity impact into a field of boulders and provide our first direct evidence for the transfer of material in a binary asteroid system due to the shedding material from radiative torques. Parts of these and possible additional albedo markings from the reentry of boulders after the DART impact may be visible to the Hera mission when it explores the post-DART Didymos system.

Astronomy and AstroPhysics↗

SU-D-BRF-07: Ultrasound and Fluoroscopy Based Intraoperative Image-Guidance System for Dynamic Dosimetry in Prostate Brachytherapy

Purpose: Prostate brachytherapy is a common treatment method for low-risk prostate cancer patients. Intraoperative treatment planning is known to improve the treatment procedure and the outcome. The current limitation of intraoperative treatment planning is the inability to localize the seeds in relation to the prostate. We developed an image-guidance system to fulfill this need to achieve intraoperative dynamic dosimetry in prostate brachytherapy. Methods: Our system is based on standard imaging equipments available in the operating room, including the transrectal ultrasound (TRUS) and the mobile C-arm. A simple fiducial is added to compute the C-arm pose. Three fluoroscopic images and an ultrasound volume of the seeds and the prostate are acquired and processed by four image processing algorithms: seed segmentation, fiducial detection with pose estimation, seed reconstruction, and seeds-to-TRUS registration. The updated seed positions allow the physician to assess the quality of implantation and dynamically adjust the treatment plan during the course of surgery to achieve improved exit dosimetry. Results: The system was tested on 10 phantoms and 37 patients. Seed segmentation resulted in a 1% false negative and 2% false positive rates. Fiducial detection with pose estimation resulted in a detection rate of 98%. Seed reconstruction had a mean reconstruction error of 0.4 mm. Seeds-to-TRUS registration had a mean registration error of 1.3 mm. The total processing time from image acquisition to registration was approximately 1 minute. Conclusion: We present an image-guidance system for intraoperative dynamic dosimetry in prostate brachytherapy. Using standard imaging equipments and a simple fiducial, our system can be easily adopted in any clinics. Robust image processing algorithms enable accurate and fast computation of the delivered dose. Especially, the system enables detection of possible hot/cold spots during the surgery, allowing the physician to address these in the operating room rather than requiring additional therapy afterwards. This research was supported in part by the National Institutes of Health/National Cancer Institute (NIH/NCI) under grant 2R44CA099374 and grant 1R01CA151395, and in part by the Department of Defense (DoD) under grant W81XWH-05-1-0407.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantitative studies on inner interfaces in conical metal joints using hard x-ray inline phase contrast radiography

Quantitative investigation of micrometer and submicrometer gaps between joining metal surfaces is applied to conical plug-socket connections in dental titanium implants. Microgaps of widths well beyond the resolving power of industrial x-ray systems are imaged by synchrotron phase contrast radiography. Furthermore, by using an analytical model for the relatively simple sample geometry and applying it to numerical forward simulations of the optical Fresnel propagation, we show that quantitative measurements of the microgap width down to 0.1 {mu}m are possible. Image data recorded at the BAMline (BESSY-II light source, Germany) are presented, with the resolving power of the imaging system being 4 {mu}m in absorption mode and {approx}14 {mu}m in phase contrast mode (z{sub 2}=0.74 m). Thus, phase contrast radiography, combined with numerical forward simulations, is capable of measuring the widths of gaps that are two orders of magnitude thinner than the conventional detection limit.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Computational and compressive imaging via additively manufactured random optical element

Here, the ubiquity of computer processing power has enabled new imaging architectures that significantly depart from traditional imaging devices. Imaging systems with deeply enmeshed algorithmic elements are known as computational imaging systems, and can take unconventional physical forms compared to photographic systems. We report on the development and evaluation of a lensless imaging system utilizing an additively manufactured transparent optical element capable of producing image reconstructions after a calibration process. A generalized metric for image quality is presented and used to evaluate system performance as a function of total samples used to calibrate and test.

97 MATHEMATICS AND COMPUTING↗

An exposure indicator for digital radiography: AAPM Task Group 116 (Executive Summary)

Digital radiographic imaging systems, such as those using photostimulable storage phosphor, amorphous selenium, amorphous silicon, CCD, and MOSFET technology, can produce adequate image quality over a much broader range of exposure levels than that of screen/film imaging systems. In screen/film imaging, the final image brightness and contrast are indicative of over- and underexposure. In digital imaging, brightness and contrast are often determined entirely by digital postprocessing of the acquired image data. Overexposure and underexposures are not readily recognizable. As a result, patient dose has a tendency to gradually increase over time after a department converts from screen/film-based imaging to digital radiographic imaging. The purpose of this report is to recommend a standard indicator which reflects the radiation exposure that is incident on a detector after every exposure event and that reflects the noise levels present in the image data. The intent is to facilitate the production of consistent, high quality digital radiographic images at acceptable patient doses. This should be based not on image optical density or brightness but on feedback regarding the detector exposure provided and actively monitored by the imaging system. A standard beam calibration condition is recommended that is based on RQA5 but uses filtration materials that are commonly available and simple to use. Recommendations on clinical implementation of the indices to control image quality and patient dose are derived from historical tolerance limits and presented as guidelines.

62 RADIOLOGY AND NUCLEAR MEDICINE↗