Dielectric Permittivity Measurements of Geologic Samples at Venus Surface Temperatures

Synthetic-aperture radar (SAR) and radar sounding are two powerful remote sensing techniques used to examine the surface and subsurface of planets. Their value is critical in the case of Venus due to this planet’s global and visually opaque cloud layer. The recently selected VERITAS and EnVision orbital missions, slated to study the planet in the early 2030’s, employ radar instruments to image the surface (VERITAS and EnVision) and probe the subsurface (EnVision). For both techniques, the complex dielectric permittivity of the surface and subsurface materials control radar backscatter intensity and penetration depth. Since the 1970’s, many studies have characterized the dielectric permittivity of geologic materials collected both on Earth and on the Moon to constrain the radar reflectivity and transparency at a variety of radar frequencies [e.g., 1]. Two consistent findings from those studies are that complex permittivity depends on both the density (or porosity) and the composition of the material. Denser materials and more metal-rich compositions tend to have higher permittivity values and to incur greater propagation path loss. Water content also elevates permittivity of otherwise dry rocks/soils/regolith [e.g., 2]. However, permittivity is independent of frequency for the 0.5-18 GHz range, within which SAR imaging commonly lies. The one aspect poorly explored thus far is the effect of elevated temperatures on dielectric permittivity. Previous work suggests that increased lattice vibrations and flow of free electrons associated with an increase in temperature elevate both the real (reflectivity) and imaginary (path loss) parts of the complex permittivity. We are currently conducting a 3-year campaign to measure the complex dielectric permittivity of Venusrelevant geologic materials at Venus surface temperatures (380°C - 460°C) and with frequencies relevant to VERITAS, EnVision, and Magellan imaging synthetic aperture radars.

M Barmatz↗

Hemispheric Asymmetry of the Annual and Semiannual Variation of Thermospheric Composition

We examine hemispheric asymmetry of the annual and semiannual variation of the ratio of O and N 2 concentrations ( O/N 2 ) using observations by the Global Ultraviolet Imager (GUVI) instrument onboard the Thermosphere Ionosphere Mesosphere Energetics and Dynamics satellite and compare them with Whole Atmosphere Community Climate Model with thermosphere-ionosphere eXtension (WACCM-X) model simulations. We found that in the equatorial region, the “equinox peaks” of the observed O/N 2 are near the end of March and October, and the two annual lows are near the beginning of July and January. Compared to the equatorial region, in the northern hemisphere (NH) low latitudes, the first “equinox peak” clearly shifts toward the December solstice, whereas in the southern hemisphere (SH) low latitudes, the “equinox peaks” shift toward the June solstice (JS), forming the hemispheric asymmetry characteristics of the annual and semiannual variation. Seasonal variation of O/N 2 shows no apparent phase variation with altitude, and the annual and semiannual pattern is consistent from year to year. WACCM-X reproduces the observed annual and semiannual pattern in NH but in SH, it simulates an annual variation instead of the observed annual and semiannual variation. The largest discrepancy occurs near JS in the lower and middle thermosphere: the simulated O density has an annual high near JS in SH; the simulated N 2 density has an annual high near JS in NH but a predominant annual low near JS in SH. These are not in the GUVI data. A weaker thermospheric meridional circulation in the winter hemisphere, or a reduced summer-to-winter latitudinal gradient of neutral temperature in WACCM-X simulations would make model-data comparisons more consistent.

thermosphere composition↗

Soft X-Ray Imaging of Earth's Dayside Magnetosheath and Cusps Using Hybrid Simulations

Interactions between solar wind ions and neutral hydrogen atoms in Earth's exosphere can lead to the emission of soft X-rays. Upcoming missions such as SMILE and LEXI aim to use soft X-ray imaging to study the global structure of the magnetosphere. Although the magnetosheath and dayside magnetopause can often be driven by kinetic physics, it has typically been omitted from fluid simulations used to predict X-ray emissions. We study the possible results of soft X-ray imaging using hybrid simulations under quasi-radial interplanetary magnetic fields, where ion-ion instabilities drive ultra-low frequency foreshock waves, leading to turbulence in the magnetosheath, affecting the dynamics of the cusp and magnetopause. We simulate soft X-ray emission to determine what may be seen by missions such as LEXI, and evaluate the possibility of identifying kinetic structures. While kinetic structures are visible in high-cadence imaging, current instruments may not have the time resolution to discern kinetic signals.

J Ng↗

Bellerophon Environment for Analysis of Materials (BEAM)

Improvements in scientific instrumentation allow imaging at mesoscopic to atomic length scales, many spectroscopic modes, and now--with the rise of multimodal acquisition systems and the associated processing capability--the era of multidimensional, informationally dense data sets has arrived. Technical issues in these combinatorial scientific fields are exacerbated by computational challenges best summarized as a necessity for drastic improvement in the capability to transfer, store, and analyze large volumes of data. The Bellerophon Environment for Analysis of Materials (BEAM) platform provides material scientists the capability to directly leverage the integrated computational and analytical power of High Performance Computing (HPC) to perform scalable data analysis and simulation and manage uploaded data files via an intuitive, cross-platform client user interface. This framework delivers authenticated, "push-button" execution of complex user workflows that deploy data analysis algorithms and computational simulations utilizing compute-and-data cloud infrastructures and HPC environments like Titan at the Oak Ridge Leadershp Computing Facility (OLCF).

Lingerfelt, Eric J↗

STATUS OF BEAM IMAGING DEVELOPMENTS FOR THE SNS TARGET

The Spallation Neutron Source (SNS) continues a ramp up in proton beam power toward the design goal of 1.4 MW on target. At Megawatt levels, US and Japanese studies have shown that cavitation in the Mercury target could lead to dramatically shortened target lifetime. Therefore, it will be critical to measure and control the proton beam distribution on the target, in a region of extremely high radiation and limited accessibility. Several sources of photons have been considered for imaging the beam on or near the target. These include a freestanding temporary screen, a scintillating coating, Helium gas scintillation, optical transition radiation, and a beam- heated wire mesh. This paper will outline the selection process that led to the current emphasis on coating development. In this harsh environment, the optics design presented significant challenges. The optical system has been constructed and characterized in preparation for installation. Optical test results will be described along with predictions of overall system performance.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Installation and Initial Operation of an On-line Target Imaging System for SNS

After several years of operation, the SNS now enters an era of megawatt class operation. At this intensity level, the target will be operating closer to its engineering limits and the beam profile on target must be carefully controlled. During commissioning and early operations, a temporary imaging system was used to measure the proton density on target. This system was not designed to survive the increasing power levels and it had to be removed in the second half of 2006. Since then, no direct measurement of beam properties at the target has been available. A collaboration was forged to remedy this situation, and has resulted in a new imaging system consisting of three major components: a thermal-sprayed luminescent coating deposited on the target nose, a radiation-tolerant optical system installed upstream of the target, and an image acquisition system integrated with the accelerator controls network. The design, installation, and integration of these components will be described. Initial beam measurements and image analysis results will be presented. Lessons learned during this initial operating experience have been documented and will guide the collaboration s future plans.

43 PARTICLE ACCELERATORS↗

Stellar Calibration of the WIC and SI Imagers and the GEO Photometers on IMAGE/FUV

The FUV instrument on the IMAGE spacecraft comprises three wide-field imagers, the Wide-Band Imaging Camera (WIC) of observing N2 Lyman-Birge-Hopfield (LBH) (140-190 nm) emissions and the Spectrographic Imager (SI), which has a 121.8 nm channel for observing red-shifted HI Lya photons and a 135.6 run channel for observing 01 135.6 nm emissions. In addition, three HI Lya photometers (GEO) are used to monitor the geocorona. The fields of view are 17 degrees x 17 degrees for the WIC imagers, 15 degrees x 15 degrees for the two SI imagers, and 10 diameter for the three GEO photometers. As the IMAGE spacecraft spins every 120 seconds, the GEO photometers sweep out circles on the sky (at 0 degrees and plus or minus 30 degrees with respect to the spacecraft spin plane), and the WIC and SI imagers use the Time Delay Integration (TDI) method to construct images centered on the Earth. Many FUV-bright stars are seen in the WIC, SI and even the GEO data. WE have used archived International Ultraviolet Explorer (IUE) far-ultraviolet flux spectra for 22 of the brightest of these stars to help refine the FUV instrumental sensitivities. The stars chosen range in spectral type form B0V to A11V, with magnitudes ranging from V- 1.3 (a Cru) to V=4.7 (G Cen) (although many more fainter stars are also seen). The initial results of this stellar calibration will be presented and compared with the pre-flight and dayglow modeling results.

Gladstone, R.↗

Image Processor

Texas Instruments Programmable Remapper is a research tool used to determine how to best utilize the part of a patient's visual field still usable by mapping onto his field of vision with manipulated imagery. It is an offshoot of a NASA program for speeding up, improving the accuracy of pattern recognition in video imagery. The Remapper enables an image to be "pushed around" so more of it falls into the functional portions in the retina of a low vision person. It works at video rates, and researchers hope to significantly reduce its size and cost, creating a wearable prosthesis for visually impaired people.

Source record↗

Design and Fabrication of a Two-Dimensional Superconducting Bolometer Array

Large format, two dimensional arrays of close-packed bolometers will enable submillimeter cameras and spectrometers to obtain images and spectra orders of magnitude faster than present instruments. The South Pole Imaging Fabry-Perot Interferometer (SPIFI) for the AST/RO observatory and the Submillimeter and Far-InfraRed Experiment (SAFIRE) on the SOFIA airborne observatory will employ a large-format, two-dimensional, closepacked bolometer arrays. Both these instruments are imaging Fabry-Perot spectrometers operating at wavelengths between 100 micron and 700 micron. The array format is 16x32 pixels, using a 32-element multiplexer developed in part for this purpose. The low backgrounds achieved in spectroscopy require very sensitive detectors with NEPs of order 5x10(exp 18) W/square root of Hz. Superconducting detectors can be close-packed using the Pop-Up Detector (PUD) format, and SQUID multiplexers operating at the detector bas temperature can be intimately coupled to them. We have fabricated an engineering model array with this technology which features a very compact, modular approach for large format arrays.

Benford, Dominic↗

Global spectroscopy and imaging of atmospheric X-ray bremsstrahlung - Instrumentation and initial results from the PEM/AXIS instrument aboard the Upper Atmosphere Research Satellite

The Atmospheric X-ray Imaging Spectrometer (PEM/AXIS) aboard NASA's Upper Atmosphere Research Satellite provides continuous horizon to horizon images, both day and night, of the 3- to 100-keV X-ray flux emitted from the top of the atmosphere. AXIS achieves a spatial resolution to better than 100 km using a one-dimensional array of 16 passively cooled silicon detectors. The primary purpose of this instrument is to provide a global monitor of electron energy input to the upper atmosphere. We describe the design, development, and calibration of AXIS and provide an assessment of its excellent on-orbit performance. The unique capabilities of X-ray imaging spectrometers are demonstrated through an analysis of specific examples from October and November 1991. Important new developments for follow-on instruments also will be described.

Chenette, D. L.↗

The MESUR Mission

The MESUR mission will place a network of small, robust landers on the Martian surface, making a coordinated set of observations for at least one Martian year. MESUR presents some major challenges for development of instruments, instrument deployment systems, and on board data processing techniques. The instrument payload has not yet been selected, but the straw man payload is (1) a three-axis seismometer; (2) a meteorology package that senses pressure, temperature, wind speed and direction, humidity, and sky brightness; (3) an alphaproton-X-ray spectrometer (APXS); (4) a thermal analysis/evolved gas analysis (TA/EGA) instrument; (5) a descent imager, (6) a panoramic surface imager; (7) an atmospheric structure instrument (ASI) that senses pressure, temperature, and acceleration during descent to the surface; and (8) radio science. Because of the large number of landers to be sent (about 16), all these instruments must be very lightweight. All but the descent imager and the ASI must survive landing loads that may approach 100 g. The meteorology package, seismometer, and surface imager must be able to survive on the surface for at least one Martian year. The seismometer requires deployment off the lander body. The panoramic imager and some components of the meteorology package require deployment above the lander body. The APXS must be placed directly against one or more rocks near the lander, prompting consideration of a micro rover for deployment of this instrument. The TA/EGA requires a system to acquire, contain, and heat a soil sample. Both the imagers and, especially, the seismometer will be capable of producing large volumes of data, and will require use of sophisticated data compression techniques.

Squyres, S. W.↗

Onboard Data Analysis for the Planetary Instrument for X-Ray Lithography

Imaging spectrometers are invaluable instruments for robotic science exploration, enabling quantitative maps of physical and chemical properties at high spatial resolution. This is particularly valuable in remote missions to other planetary bodies like Mars. The PIXL instrument on the Mars 2020 rover will deploy an arm-mounted X-Ray fluorescence spectrometer to map chemical composition at sub-millimeter scales. Its high resolution places dramatic new demands on instrument placement accuracy and measurement time. We address these challenges using novel on board data analysis strategies inspired by FRC science autonomy research.

Thompson, David R.↗

Creation of Anatomically Accurate Computer-Aided Design (CAD) Solid Models from Medical Images

Most surgical instrumentation and implants used in the world today are designed with sophisticated Computer-Aided Design (CAD)/Computer-Aided Manufacturing (CAM) software. This software automates the mechanical development of a product from its conceptual design through manufacturing. CAD software also provides a means of manipulating solid models prior to Finite Element Modeling (FEM). Few surgical products are designed in conjunction with accurate CAD models of human anatomy because of the difficulty with which these models are created. We have developed a novel technique that creates anatomically accurate, patient specific CAD solids from medical images in a matter of minutes.

Stewart, John E.↗

Optical Design and Predicted Performance of the WFIRST Phase-B Imaging Optics Assembly and Wide Field Instrument

Now in Phase-B, the architecture of the Wide-Field Infra-Red Survey Telescope (WFIRST) payload has matured since 2013 to accommodate various opto-mechanical constraints. Based on a 2.4-meter aperture Forward Optical Assembly (FOA), the Imaging Optics Assembly (IOA) provides corrected optical fields to each on-board instrument. Using a Three Mirror Anastigmat (TMA) optical design, the Wide-Field Channel (WFC) provides ~1/3-square degree of instantaneous field coverage at 0.11 arcsecond pixel scale. The WFC as-built predictive analysis anticipates near diffraction-limited imaging over a focal plane of 300.8 million pixels, operating in seven panchromatic bands between 0.48 - 2.0μm, or a 1-octive multi-spectral imaging mode from ~0.95-1.93μm. The IOA provides the Coronagraph Instrument (CGI) a collimated beam with very specific wavefront constraints. We present configuration changes since 2013 that improved interfaces, improved testability, and reduced technical risk. We provide an overview of our Integrated Modeling results, performed at an unprecedented level for a phase-A study, to illustrate performance margins with respect to static wavefront error, jitter, and thermal drift.

Dark Energy↗

Preliminary Design and Analysis of the GIFTS Instrument Pointing System

The Geosynchronous Imaging Fourier Transform Spectrometer (GIFTS) Instrument is the next generation spectrometer for remote sensing weather satellites. The GIFTS instrument will be used to perform scans of the Earth s atmosphere by assembling a series of field-of- views (FOV) into a larger pattern. Realization of this process is achieved by step scanning the instrument FOV in a contiguous fashion across any desired portion of the visible Earth. A 2.3 arc second pointing stability, with respect to the scanning instrument, must be maintained for the duration of the FOV scan. A star tracker producing attitude data at 100 Hz rate will be used by the autonomous pointing algorithm to precisely track target FOV s on the surface of the Earth. The main objective is to validate the pointing algorithm in the presence of spacecraft disturbances and determine acceptable disturbance limits from expected noise sources. Proof of concept validation of the pointing system algorithm is carried out with a full system simulation developed using Matlab Simulink. Models for the following components function within the full system simulation: inertial reference unit (IRU), attitude control system (ACS), reaction wheels, star tracker, and mirror controller. With the spacecraft orbital position and attitude maintained to within specified limits the pointing algorithm receives quaternion, ephemeris, and initialization data that are used to construct the required mirror pointing commands at a 100 Hz rate. This comprehensive simulation will also aid in obtaining a thorough understanding of spacecraft disturbances and other sources of pointing system errors. Parameter sensitivity studies and disturbance analysis will be used to obtain limits of operability for the GIFTS instrument. The culmination of this simulation development and analysis will be used to validate the specified performance requirements outlined for this instrument.

Zomkowski, Paul P.↗

The QUIET Instrument

The Q/U Imaging ExperimenT (QUIET) is designed to measure polarization in the Cosmic Microwave Background, targeting the imprint of inflationary gravitational waves at large angular scales ( approx 1 deg.) . Between 2008 October and 2010 December, two independent receiver arrays were deployed sequentially on a 1.4 m side-fed Dragonian telescope. The polarimeters which form the focal planes use a highly compact design based on High Electron Mobility Transistors (HEMTs) that provides simultaneous measurements of the Stokes parameters Q, U, and I in a single module. The 17-element Q-band polarimeter array, with a central frequency of 43.1 GHz, has the best sensitivity (69 micro Ks(exp 1/2)) and the lowest instrumental systematic errors ever achieved in this band, contributing to the tensor-to-scalar ratio at r < 0.1. The 84-element W-band polarimeter array has a sensitivity of 87 micro Ks(exp 1/2) at a central frequency of 94.5 GHz. It has the lowest systematic errors to date, contributing at r < 0.01 (QUIET Collaboration 2012) The two arrays together cover multipoles in the range l approximately equals 25-975 . These are the largest HEMT-ba.sed arrays deployed to date. This article describes the design, calibration, performance of, and sources of systematic error for the instrument,

Gaier, T.↗