Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “gain”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Relationship Between Latchup And Transistor Current Gain

Theoretical study takes new look at current-vs.-voltage behavior of silicon controlled rectifiers (SCR's), four-layer complementary metal oxide/semiconductor (CMOS) devices, and similar devices susceptible to latchup. For purposes of analysis, "latchup" denotes transition of such device from lower-current-conducting steady state to distinct higher-current-conducting steady state. Focuses upon conventional two-couple-transistor model of one-dimensional SCR. Although model gives oversimplified view of latchup in CMOS circuits, useful for qualitative predictions of electrical characteristics.

Edmonds, Larry D.↗

A non-Markovian model of avalanche gain statistics for a solid-state photomultiplier

A solid-state photomultiplier (SSPM) capable of continously detecting individual photons of wavelength between 0.4 and 28 microns has recently been disclosed (Petroff et al., 1987). The initial response of the SSPM to single photon is a fast, high-amplitude current pulse of between 10,000 and 100,000 electrons. A phenomenological model of the SSPM avalanche process is presented which successfully predicts the shape of the observed pulse-amplitude distribution by including small history-dependent effects on the carrier transport. The model clarifies the consequences of the electric field strength and the scattering of the electrons for the development of the avalanche in the SSPM.

Laviolette, Randall A.↗

Low-Noise, Long-Life, High-Gain Microchannel-Plate Glass

Dark noise reduced substantially without degrading other properties. Glass suitable for use as active material for microchannel plates (MCP's) free of constituents including significant amounts of radioactive isotopes.

Feller, W. Bruce↗

Small gain robustness issues in the p-integrator repetitive controller

The basic theory of the digital p-integrator controller is utilized to modify the command to a stable analog feedback control system in order to produce zero tracking error of a repetitive command. Mapping of continuous time poles and zeros to the images in the discrete time domain is performed. It is shown that for a pole excess of one, with p odd, the p-integrator learning controller will often produce a stable learning process, even for relatively large sample times. For a pole excess of two, a stable learning process can often be achieved for any p as long as the sample time is kept sufficiently short. Therefore, when the pole excess is zero and one utilizes the proper p-integrator controller with p odd, stable performance is often produced, even for relatively large sample times.

Longman, Richard W.↗

Channel assignments and array gain bounds for the Ka-band array feed compensation system

The performance of a real-time digital combining system for use with array feeds was considered previously. The purpose of the combining operation is to recover signal to noise ratio (SNR) losses due to antenna deformations and atmospheric effects. Previously, arbitrary signal powers and noise variances were assumed, but no attempt was made to match the receiver channels to the available signal powers. It is shown that for any signal power and noise variance distribution, a best channel assignment exists that maximizes the combined SNR in the limit of vanishingly small combining losses. This limit can be approached in practice by observing sufficiently many samples. Specific signal power and noise variance distributions are considered, and it is shown that even relatively noisy channels can be used effectively to recover SNR losses resulting from signals diverted out of a high-quality channel by antenna deformations.

Vilnrotter, V. A.↗

Experience gained in operation of the VLF ATD lightning location system

The United Kingdom (UK) Meteorological Office's Very Low Frequency (VLF) Arrival Time Difference (ATD) System for long-range location of lightning flashes started automatic international issue of lightning-location products on 17 Jun. 1988. Data from before and after this formal start-date were carefully scrutinized to judge performance. Techniques for estimating location accuracy include internal consistency and comparisons against other systems. Other areas studied were range (up to several thousand km); detection efficiency, saturation effects in active situations, and communication difficulties (for this redundant system); and spurious fix rate. Care was taken to assess the potential of the system, in addition to identifying the operational difficulties of the present implementation.

Lee, Anthony C. L.↗

Anomalous gain in an isotopically mixed CO2 laser and application to absolute wavelength calibration

Measurements are reported on a grating-tuned CO2 laser, containing an isotropic mixture of O-16C-12O-16, O-16C-12O-18, and O-18C-12O-18. The P6 and R14 lines of O-16C-12O-16 were found to have anomalously high intensities. These anomalies are produced by the near coincidence of the transition frequencies in two distinct isotopes, permitting them to act as a single indistinguishable population. These two lines can be used to identify the rotational quantum numbers in the P and R branch spectra, thereby permitting absolute wavelength calibration to be achieved.

Hewagama, Tilak↗

Gain, Level, And Exposure Control For A Television Camera

Automatic-level-control/automatic-gain-control (ALC/AGC) system for charge-coupled-device (CCD) color television camera prevents over-loading in bright scenes using technique for measuring brightness of scene from red, green, and blue output signals and processing these into adjustments of video amplifiers and iris on camera lens. System faster, does not distort video brightness signals, and built with smaller components.

Major, Geoffrey J.↗

Flight test of ARINC 741 configuration low gain SATCOM system on Boeing 747-400 aircraft

The Boeing company conducted a flight test of a SATCOM system similar to the ARINC 741 configuration on a production model 747-400. A flight plan was specifically designed to test the system over a wide variety of satellite elevations and aircraft attitudes as well as over land and sea. Interface bit errors, signal quality and aircraft position and navigational inputs were all recorded as a function of time. Special aircraft maneuvers were performed to demonstrate the potential for shadowing by aircraft structures. Both a compass rose test and the flight test indicated that shadowing from the tail is insignificant for the 747-400. However, satellite elevation angles below the aircraft horizon during banking maneuvers were shown to have a significant deleterious effect on SATCOM communications.

Murphy, Timothy A.↗

Explicit construction of quadratic Lyapunov functions for the small gain, positivity, circle, and Popov theorems and their application to robust stability

Lyapunov function proofs of sufficient conditions for asymptotic stability are given for feedback interconnections of bounded real and positive real transfer functions. Two cases are considered: (1) a proper bounded real (resp., positive real) transfer function with a bounded real (resp., positive real) time-varying memoryless nonlinearity; and (2) two strictly proper bounded real (resp., positive real) transfer functions. A similar treatment is given for the circle and Popov theorems. Application of these results to robust stability with time-varying bounded real, positive real, and sector-bounded uncertainty is discussed.

Haddad, Wassim M.↗

What do you gain from deconvolution? - Observing faint galaxies with the Hubble Space Telescope Wide Field Camera

We describe experiments with deconvolutions of simulations of deep HST Wide Field Camera images containing faint, compact galaxies to determine under what circumstances there is a quantitative advantage to image deconvolution, and explore whether it is (1) helpful for distinguishing between stars and compact galaxies, or between spiral and elliptical galaxies, and whether it (2) improves the accuracy with which characteristic radii and integrated magnitudes may be determined. The Maximum Entropy and Richardson-Lucy deconvolution algorithms give the same results. For medium and low S/N images, deconvolution does not significantly improve our ability to distinguish between faint stars and compact galaxies, nor between spiral and elliptical galaxies. Measurements from both raw and deconvolved images are biased and must be corrected; it is easier to quantify and remove the biases for cases that have not been deconvolved. We find no benefit from deconvolution for measuring luminosity profiles, but these results are limited to low S/N images of very compact (often undersampled) galaxies.

Schade, David J.↗

Some results gained from JAPE: An overview

During JAPE, a variety of sound propagation experiments were conducted including long range measurements and investigations of the masking of sound by natural barriers. An overview of the measurements is given. A comparison between measured SPL's and theoretical estimates is presented.

Becker, Gunnar R.↗