Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flow test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Flow and Heat Transfer Tests in New Loop at 2757 kPa (400 psi)

A helium flow and heat transfer experiment has been designed for the new helium flow loop facility at LANL. This new facility is centered on an Aerzen GM 12.4 Root’s blower, selected for operation at higher pressure, up to 2757 kPa, and mass flow rate, up to 400 g/s. This replaces the previous Tuthill PD plus 3206 blower and loop limited to 2067 kPa (300 psi) and 100 g/s. The resistively heated test piece is comprised of 7 electric heaters with embedded thermocouples. The plant design for the Mo100 to Mo99 targets requires sharp bends and geometry changes in the helium flow tube immediately before and after the target. An idealized fully developed flow configuration with straight entry and exit will be tested and compared with an option that employs rectangular tubing to make the bend at a radius consistent with and practical for the actual plant design. The current plant design, with circular tubing and a sudden contraction to rectangular just prior to target entrance, will also be tested. This requires some modification of the test piece, as described in the report.

42 ENGINEERING↗

Flow Characterization of the NASA Langley Unitary Plan WindTunnel, Test Section 2: Computational Results

Flow in the empty Unitary Planform Wind Tunnel at the NASA Langley Research Center issimulated with computational fluid dynamics methods. The objectives are to assess CFD’s truepredictive capability and to generate flow-field maps upstream of the tunnel’s test section foruse in associated vehicle tests. Multiple CFD solvers, grid adaption methods, and turbulencemodels are used by five teams doing the simulations. The simulation domain is as large aspractical: from the start of the settling chamber, just downstream of the last set of turningvanes, to well downstream of the test section. Simulations are done at three Mach numbers andseveral Reynolds numbers that cover most of the tunnel’s operating range. The sensitivity ofthe CFD solutions to simulation process details, including turbulence model, spatial resolutionand settling-chamber inflow velocity profile, is characterized. Significant sensitivities in somedetails of the predicted test section flow are described. CFD predicts that details of flow inthe settling chamber can affect the flow in the test section. Turning of the flow through thetunnel contraction and past nozzle-block hardware generates streamwise vortices, some ofwhich survive into the core of the test section, principally at low Mach number. Preliminarycomparisons to experimental measurements are given. The major flow characteristics andthe dynamical vortices predicted by CFD exist in the experiment. Several details in CFD andexperiment are observed to differ, including the effects of the vortices and features that appearto be Mach waves in the test section. Sensitivity to grid resolution and turbulence modelingis noted in the vortices; no potential cause for the differences in Mach waves has yet beenidentified in the CFD sensitivity studies.

wind tunnel↗

Pressure Drop Across Woven Screens Under Uniform and Nonuniform Flow Conditions

Tests were conducted to determine the experimental pressure drop and velocity data for water flowing through woven screens. The types of materials used are dutch twill and square weave fabrics. Pressure drop measures were made at four locations in a rectangular channel. The data are presented as change in pressure compared with the average entry velocity and the numerical relationship is determined by dividing the volumetric flow rate by the screen area open to flow. The equations of continuity and momentum are presented. A computer program listing an extension of a theoretical model and data from that computer program are included.

Ludewig, M.↗

Transport models of the turbulent velocity-temperature products for computations of recirculating flows

Performance tests of the third-order turbulence closure for predictions of separating and recirculating flows in backward-facing steps were studied. Computations of the momentum and temperature fields in the flow domain being considered entail the solution of time-averaged transport equations containing the second-order turbulent fluctuating products. The triple products, which are responsible for the diffusive transport of the second-order products, attain greater significance in separating and reattaching flows. The computations are compared with several algebraic models and with the experimental data. The prediction was improved considerably, particularly in the separated shear layer. Computations are further made for the temperature-velocity double products and triple products. Finally, several advantages were observed in the usage of the transport equations for the evaluation of the turbulence triple products; one of the most important features is that the transport model can always take the effects of convection and diffusion into account in strong convective shear flows such as reattaching separated layers while conventional algebraic models cannot account for these effects in the evaluation of turbulence variables.

Amano, R. S.↗

The Design and Use of Calorimeters For Characterization of High-Enthalpy Flows in Arc-Heated Test Facilities

High-enthalpy, arc-heated flows used for aerothermal testing present a challenging environment for flow characterization. This paper describes the design and use of cooled dwell probes used for heat-transfer and pressure characterization of the NASA and United States Department of Defense (DoD) arc facilities located at Moffett Field, CA, and Arnold Air Force Base, TN. Dwell calorimeters designed, fabricated, and tested by Thermal Technologies, Inc. (TTI) in the NASA IHF and the USAF H1 and H2 arc test facilities provide heat flux and pressure data with excellent repeatability. These calorimeters use standard Gardon calorimeter gages and pressure ports with unique cooling systems enabling them to withstand the severe arc-heated environments for durations sufficient for acquisition of steady-state data. The TTI probes have proven very robust in the extreme aerothermal environments of these facilities. This paper provides an overview of calorimeter instruments typically used in arc facilities, discusses design features of the TTI dwell probes, presents selected data acquired by the TTI calorimeters, and provides comparisons with data acquired from using measurement techniques.

D Mark Smith↗

A Report on Superfluid Helium Flow Through Porous Plugs for Space Science Applications

As a background for the study of the nature of superfluid helium flow through porous plugs for other space science uses, preliminary tests on various plugs of a given material, diameter, height, and filtration grade have been performed. Two characteristics of the plugs, pore size and number of channels, have been determined by the bubble test and warm flow test of helium gas through the plugs, respectively. Tests on the flow of He II through the plugs have also been performed. An obvious feature of the results of these tests is that for isothermal measurements of pressure versus mass flow rate below approximately 2.10 K, the flow is separated into two different regimes, indicative of the occurrence of a critical phenomenon.

Mason, F. C.↗

Generating high Reynolds-number flows.

Present test facilities are seriously limited regarding investigations involving high Reynolds numbers due to financial considerations. Quasi-steady testing facilities offer a practical immediate solution to the problem of high-Re testing. A familiar example is the blowdown wind tunnel, but even more flexibility and economy may be provided by using shock-tube devices. The Ludwieg tube is the shock-tube device most often proposed as a means of generating high-Re flows. Two-stage nozzles may be used with a Ludwieg tube. Quasi-steady facilities will be useful only if the available test time exceeds that required to establish steady flow.

Russell, D. A.↗

Short-duration, transonic flow, variable-porosity test section

Short-duration test facility obtains extremely high Reynolds number flows in subsonic, transonic, and supersonic speed ranges, and aids in solving Reynolds number-dependent aerodynamic and thermodynamic problems in design and testing of large, high speed vehicles. The modified blowdown wind tunnel avoids data confusion and aerodynamic noise.

Davis, J. W.↗

Operational evaluation of a proppeller test stand in the quiet flow facility at Langley Research Center

Operational proof tests of a propeller test stand (PTS) in a quiet flow facility (QFF) are presented. The PTS is an experimental test bed for acoustic propeller research in the quiet flow environment of the QFF. These proof tests validate thrust and torque predictions, examine the repeatability of measurements on the PTS, and determine the effect of applying artificial roughness to the propeller blades. Since a thrusting propeller causes an open jet to contract, the potential flow core was surveyed to examine the magnitude of the contraction. These measurements are compared with predicted values. The predictions are used to determine operational limitations for testing a given propeller design in the QFF.

Block, P. J. W.↗

Assessment of Flow-Enhanced Electrochemical Sensor Testing and Deployments for MSRs

This report serves as the deliverable for Milestone M3RS-23AN0401061 that is part of Work Package RS-23AN040106 (Flow Enhanced Sensors for MSRs – ANL). The goal of this milestone was to determine performance of the flow enhanced electrochemical sensor (FEES) and modular flow instrumentation testbed (MFIT) in safeguards relevant scenarios. Flow enhanced electrochemical sensors are a type of electroanalytical sensor that has been developed at Argonne National Laboratory to be installed directly into MSR flow conduits to make measurements of the salt composition. These sensors represent a significant improvement in capabilities compared to earlier electroanalytical sensors that instead can only be operated in quiescent conditions. Previous work has focused on testing of the FEES in flowing conditions provided by the MFIT to assess the accuracy and precision of the sensor measurements. To further improve this capability, in FY23 we undertook a campaign of safeguards relevant scenarios in molten salt containing a range of uranium chloride concentrations (0 to 3 wt%). All the testing carried out in FY23 was aided by a control system designed to automatically actuate flow conditions and collect data. This new automation system is estimated to have increased experimental throughput by a factor of four and enabled testing in a variety of complex conditions. The advancements in throughput and repeatability led to improved quantification of actinide concentrations using the in-flow sensors, with a reduction of the mean absolute relative error from 5.6% in FY22 to 3.1% in FY23. In addition to safeguards scenarios run in the MFIT, FY23 work included deployment of a FEES at a partner institution where it will be tested in a flowing salt loop. The FEES was successfully integrated into that loop and is being tested prior to loop startup. In FY23, work also continued on the smaller flow system that we have named the mini-MFIT. This smaller system is capable of rapid prototyping of new sensor designs prior to installation in the larger MFIT radiological flow system. Work was carried out to test this new system in non-radiological molten salts in a separate glovebox. This work is helping us to enhance the accuracy of our salt monitoring capabilities through the integration of multiple types of sensors. The high degree of accuracy required by 10 CFR 74 represents a significant challenge, and further design evolution and integration of the sensors into multimodal sensing frameworks will be needed to further push the measurement accuracy to the needed level.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The state of the art of conventional flow visualization techniques for wind tunnel testing

Conventional wind tunnel flow visualization techniques which consist of surface flow methods, tracers, and optical methods are presented. Different surface flow methods are outlined: (1) liquid films (oil and fluorescent dye and UV lighting, renewable film via porous dispenser in model, volatile carrier fluid, cryogenic colored oil dots, oil film interferometry); (2) reactive surface treatment (reactive gas injection, reversible dye); (3) transition and heat transfer detectors (evaporation, sublimation, liquid crystals, phase change paints, IR thermography); and (4) tufts (fluorescent mini tufts, cryogenic suitability). Other methods are smoke wire techniques, vapor screens, and optical methods.

Settles, G. S.↗

Assessment of Flow-Enhanced Electrochemical Sensor Testing and Deployments

The goal of our activities in FY24 was to enable advanced materials accountancy for molten salt reactors (MSRs) through the development and optimization of robust flow-enhanced electrochemical sensors (FEES) using a safeguards-focused sensor testing platform called the modular flow instrumentation testbed (MFIT). Flow-enhanced electrochemical sensors are a type of electroanalytical sensor that have been developed at Argonne National Laboratory to be installed directly into MSR flow conduits to make measurements of the salt composition. These sensors represent a significant improvement in capabilities compared to earlier electroanalytical sensors that instead can only be operated in quiescent conditions. Previous work has focused on testing of the FEES in flowing conditions provided by the MFIT to assess the accuracy and precision of the sensor measurements. This year, the FEES technical readiness was increased by (1) demonstrating the use of optimized sensor techniques to achieve measurements in very high-concentration MSR-relevant salts, (2) leveraging new multimodal sensors and automation approaches to reduce measurement uncertainties, and (3) fabricating and deploying sensors to industrial partners to improve their ability to make measurements in challenging environments. Additionally, we also ran the sensors during complex system operations involving combined flow and purification activities to demonstrate safeguards-relevant measurements during online processing for MSRs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

An experimental investigation of end treatments for nonreturn wind tunnels

The results of a series of flow quality and performance tests on several inlet and exit configurations for nonreturn wind tunnels are presented. Test section flow angularities, local dynamic pressure variations, and total-pressure-loss variations are presented as functions of wind-to-test-section dynamic pressure ratio. The results show that a nonreturn wind tunnel should have end treatments with three characteristics: (1) a vertical exit system, (2) a horizontal inlet system, and (3) an area of protected enclosure at the inlet. Inlet and exhaust treatments were developed that produced good aerodynamic flow qualities with low power penalties.

Eckert, W. T.↗

Particle Vertical Mixing and Horizontal Conveyance Within an Ambient Temperature Fluidized Bed

Previous studies have shown the advantages of particle-to-sCO2 fluidized bed (FB) heat exchangers, which include high heat transfer coefficients, low material cost, and the ability to horizontally convey solid particles. This paper outlines the design and testing of a compact cold flow FB test apparatus to characterize horizontal conveyance through convolutions within a 100 kWth FB heat exchanger design. Horizontal conveyance is an advantage in FBs because it enables more compact designs for heat exchangers. Two mass flow rates, 0.5 & 1 kg/s, at the inlet & outlet of the FB. To determine consistency of the flow rates, Student’s t-tests were used to assess whether the inlet & outlet values were statistically similar. The mass flow rate exiting the bed was statistically similar to the flow rate entering the bed for both cases, but each case featured a wider range and standard deviation. The range and standard deviation of the 1 kg/s flow rate was 0.69-1.23 kg/s and 0.12 kg/s respectively, and the 0.5 kg/s test featured a range and standard deviation of 0.37-0.73 kg/s and 0.09 kg/s, respectively. These measurements provide confidence that large-scale designs can successfully horizontally convey particles at ````~1.5x minimum fluidization velocity (U­mf) without significant variation in flow rate. A method to characterize the degree of particle vertical mixing and bubble frequency within the FB is also introduced. By using a high-resolution camera together with particle velocimetry, particle motion in the X and Y directions can be estimated to assess bed mixing and bubble frequency.

Khalaf, Jawad↗

On Characterization of Flow Disturbances in Arc-Jet Testing

This paper reports computational simulations and analysis of flow characterization tests in high enthalpy arc-jet facilities at NASA Ames Research Center. Flow disturbances and their characterization are presented through case studies, and their implications for testing are discussed. The case studies include free-jet test configurations from three different arc heaters and nozzles: the 60-MW IHF 30-inch conical nozzle, the 10-MW TP3 15-inch conical nozzle, and the 20-MW AHF 12-inch conical nozzle. For all cases, test articles are placed in the jet exiting the conical nozzle, and the existence of a flow disturbance is confirmed through flow survey data using pitot pressure and heat flux probes and accompanying analysis. The paper focuses on cases where the effects of the disturbances on test article surface quantities are important. The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzles and test box, including the models tested. Comparisons of computations with the experimental measurements are presented. The computations that reproduce the probe sweep data approximately are essential to interpret the arc-jet test data accurately, while providing insights into several observed calorimeter anomalies caused by flow disturbances.

Arc-jet testing↗

On Characterization of Flow Disturbances in Arc-Jet Testing

This paper reports computational simulations and analysis of flow characterization tests in high enthalpy arc-jet facilities at NASA Ames Research Center. Flow disturbances and their characterization are presented through case studies, and their implications for testing are discussed. The case studies include free-jet test configurations from three different arc heaters and nozzles: the 60-MW IHF 30-inch conical nozzle, the 10-MW TP3 15-inch conical nozzle, and the 20-MW AHF 12-inch conical nozzle. For all cases, test articles are placed in the jet exiting the conical nozzle, and the existence of a flow disturbance is confirmed through flow survey data using pitot pressure and heat flux probes and accompanying analysis. The paper focuses on cases where the effects of the disturbances on test article surface quantities are important. The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzles and test box, including the models tested. Comparisons of computations with the experimental measurements are presented. The computations that reproduce the probe sweep data approximately are essential to interpret the arc-jet test data accurately, while providing insights into several observed calorimeter anomalies caused by flow disturbances.

Arc-jet testing↗