Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flow meter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Experimental and Computational Evaluation of Flush-Mounted, S-Duct Inlets

A new high Reynolds number test capability for boundary layer ingesting inlets has been developed for the NASA Langley Research Center 0.3-Meter Transonic Cryogenic Tunnel. Using this new capability. an experimental investigation of four S-duct inlet configurations was conducted. A computational study of one of the inlets was also conducted using a Navier-Stokes solver. The objectives of this investigation were to: 1) develop a new high Reynolds number inlet test capability for flush-mounted inlets; 2) provide a database for CFD tool validation; 3) evaluate the performance of S-duct inlets with large amounts of boundary layer ingestion; and 4) provide a baseline inlet for future inlet flow-control studies. Tests were conducted at Mach numbers from 0.25 to 0.83. Reynolds numbers (based on duct exit diameter) from 5.1 million to a full-scale value of 13.9 million, and inlet mass-flow ratios from 0.39 to 1.58 depending on Mach number. Results of the experimental study indicate that inlet pressure recovery generally decreased and inlet distortion generally increased with increasing Mach number. Except at low Mach numbers, increasing inlet mass-flow increased pressure recovery and increased distortion. Increasing the amount of boundary layer ingestion or ingesting a boundary layer with a distorted profile decreased pressure recovery and increased distortion. Finally, increasing Reynolds number had almost no effect on inlet distortion but increased inlet recovery by about one-half percent at a Mach number near cruise. The computational results captured the inlet pressure recovery and distortion trends with Mach number and inlet mass-flow well: the reversal of the pressure recovery trend with increasing inlet mass-flow at low and high Mach numbers was predicted by CFD. However, CFD results were generally more pessimistic (larger losses) than measured experimentally.

Berrier, Bobby L.↗

Performance of LI-1542 reusable surface insulation system in a hypersonic stream

The thermal and structural performance LI-1542 reusable surface insulation (RSI) tiles was investigated. The test panel was designed to represent part of the surface structure on a space shuttle orbiter fuselage along a 1250 K isotherm. Aerothermal tests were conducted at a free-stream Mach number of 6.6, a total temperature of 1820 K, Reynolds numbers of 2 millon and 5 million per meter, and dynamic pressures of 26 and 65 kPa. The RSI tiles demonstrated good thermal protection and structural integrity. High temperatures were caused by misalinement in tile height, offset the tile longitudinal alinement, and leakage around thermal seals when differential pressure existed across the panel. The damage tolerance of LI-1542 RSI appeared high. The tile coating crazed early in the test program, but this did not effect the tile integrity. Erosion of the tile edges occurred at forward-facing steps and at the ends of longitudinal gaps because of particle impacts and flow shear.

Hunt, L. R.↗

Coaxial Rotor CFD Validation and ML Surrogate Model Generation

A fixed-pitch speed-controlled coaxial rotor system was tested in the NASA Langley Transonic Dynamics Tunnel in September 2022. The rotors have a diameter of 1.35 meters and an inter-rotor spacing of 25% of the diameter. Though this test was focused on the NASA New Frontiers Dragonfly mission, the resulting dataset is relevant to a wide array of applications of multirotor vehicles, especially those using fixed-pitch variable-speed rotors. Most notably beyond Dragonfly, perhaps, is the application of coaxial rotor pair configurations for eVTOL and Urban Air Mobility (UAM) aircraft. This work provides a thorough CFD validation study quantifying coaxial rotor performance estimation with accuracy on order 5-10% using an efficient hybrid BEMT-URANS flow solver over a wide range of operating conditions. This accuracy was achieved using novel approaches for the construction of both the C81 airfoil performance lookup tables and the BEMT rotor model. These novel approaches are combined with advanced scripting to further accelerate the commercial off-the-shelf CFD solver on GPU accelerated machines. Finally, the development of machine learning surrogate models is presented to produce highly efficient and accurate rotor performance predictions for fixed-pitch variable-speed multirotor aircraft over the complete flight regime including scout, cruise, climb, descent, as well as limiting cases of vortex-ring and windmill-brake states.

Coaxial↗

Turbulence characteristics of compressor discharge flows

Turbulence measurements were conducted in a large gas turbine engine (JT9D) at the entrance to the diffuser duct, joining the compressor discharge to the combustor inlet. Hot film probe and hot wire probe measurements were obtained at temperatures from 450K (350F) (idle) to 608K (635F) (rich approach). At I.D. (25 percent span) and mid-span locations, the turbulence intensity increased slightly from 6 + or - percent at idle condition to 7 or - 1 percent at rich approach. At O.D. (75 percent span) the turbulent intensity increased more rapidly, from 7.5 + or - 0.5 percent at idle to 15 + or - 0.5 percent at rich approach. The spectra showed turbulent energy distributed uniformly over a 0.1 to 5 KHz bandwidth (down 3db) at all operating conditions, corresponding to random turbulence with velocity wave lengths of 2 cm to 1 meter travelling at the mean velocity of 100 m/sec. Tests results are given in tables and graphs.

Grant, H. P.↗

Mars - Wind streak production as related to obstacle type and size

The characteristics of wind streaks associated with Martian craters and hills in the size range of 100 m to 80 km (corresponding to obstacle heights of a few to several hundred meters) have been analyzed from Viking Orbiter images. Both dark erosional and bright depositional streaks form over the entire obstacle size range, but there are preferred obstacle sizes for producing streaks. Bright streaks form more readily in association with relatively smaller obstacles than do dark streaks. Small obstacles produce both types of streaks more effectively than do large ones. Hills produce streaks as effectively as do craters of comparable height. Alternative explanations of bright streak formation are evaluated in terms of their ability to account for these observations. The most satisfactory models invoke blocking of atmospheric flow downwind of an obstacle and consequent deposition of dust within the sheltered zone.

Lee, S. W.↗

An Iron-Rain Model for Core Formation on Asteroid 4 Vesta

Asteroid 4 Vesta is differentiated into a crust, mantle, and core, as demonstrated by studies of the eucrite and diogenite meteorites and by data from NASA's Dawn spacecraft. Most models for the differentiation and thermal evolution of Vesta assume that the metal phase completely melts within 20 degrees of the eutectic temperature, well before the onset of silicate melting. In such a model, core formation initially happens by Darcy flow, but this is an inefficient process for liquid metal and solid silicate. However, the likely chemical composition of Vesta, similar to H chondrites with perhaps some CM or CV chondrite, has 13-16 weight percent S. For such compositions, metal-sulfide melting will not be complete until a temperature of at least 1350 degrees Centigrade. The silicate solidus for Vesta's composition is between 1100 and 1150 degrees Centigrade, and thus metal and silicate melting must have substantially overlapped in time on Vesta. In this chemically and physically more likely view of Vesta's evolution, metal sulfide drops will sink by Stokes flow through the partially molten silicate magma ocean in a process that can be envisioned as "iron rain". Measurements of eucrites show that moderately siderophile elements such as Ni, Mo, and W reached chemical equilibrium between the metal and silicate phases, which is an important test for any Vesta differentiation model. The equilibration time is a function of the initial metal grain size, which we take to be 25-45 microns based on recent measurements of H6 chondrites. For these sizes and reasonable silicate magma viscosities, equilibration occurs after a fall distance of just a few meters through the magma ocean. Although metal drops may grow in size by merger with other drops, which increases their settling velocities and decreases the total core formation time, the short equilibration distance ensures that the moderately siderophile elements will reach chemical equilibrium between metal and silicate before metal drop merger becomes important. In this model, there must be at least 30 percent melting of the silicate phase when metal melting is complete, corresponding to a crust thickness of at least 30 kilometers on Vesta, consistent with Dawn gravity observations. Greater degrees of silicate melting and a correspondingly thicker crust are possible if Vesta accreted sufficiently rapidly.

Kiefer, Walter S.↗

A fan pressure ratio correlation in terms of Mach number and Reynolds number for the Langley 0.3 meter transonic cryogenic tunnel

Calibration data for the two dimensional test section of the Langley 0.3 Meter Transonic Cryogenic Tunnel were used to develop a Mach number-Reynolds number correlation for the fan pressure ratio in terms of test section conditions. Well established engineering relationships combined to form an equation which is functionally analogous to the correlation. A geometric loss coefficient which is independent of Reynolds number or Mach number was determined. Present and anticipated uses of this concept include improvement of tunnel control schemes, comparison of efficiencies for operationally similar wind tunnels, prediction of tunnel test conditions and associated energy usage, and determination of Reynolds number scaling laws for similar fluid flow systems.

Lawing, P. L.↗

Onset of condensation effects as detected by total pressure probes in the Langley 0.3-meter transonic cryogenic tunnel

Total pressure probes mounted in the test section of a 0.3 meter transonic cryogenic tunnel were used to detect the onset of condensation effects for free stream Mach numbers of 0.50, 0.75, 0.85, and 0.95 and for total pressure between one and five atmospheres. The amount of supercooling was found to be about 3 K and suggests that condensation was occurring on pre-existing liquid nitrogen droplets resulting from incomplete evaporation of the liquid nitrogen injected to cool the tunnel. The liquid nitrogen injection process presently being used for the 0.3 m tunnel was found to result in a wide spectrum of droplet sizes being injected into the flow. Since the relatively larger droplets took much more time to evaporate than the more numerous smaller droplets, the larger ones reached the test section first as the tunnel operating temperature was reduced. However, condensation effects in the test section were not immediately measurable because there was not a sufficient number of the larger droplets to have an influence on the thermodynamics of the flow.

Hall, R. M.↗

Electrodynamics payloads for small rockets

Totally integrated design facilitates electrical cleanliness and light weight, which are necessary in subsonic parachute-borne payloads for electrodynamics investigations. 'Blunt' probes measure ion conductivity, as do Gerdien condensers. Recent finite-element computer analyses combining flow and electrodynamics have resolved problems in determining ion densities and mobilities from Gerdien data. Three-axis electric fields are measured with deployable boom-mounted electrodes from dc through VLF. Splitting the cylindrical payload with an insulator and measuring the current between halves has provided a vertical Maxwell current detector mechanically rigid enough to measure, at ELF, energy related to coupling. A nose tip 'Smith' probe turbulence measurement is usually performed on ascent. Other instrumentation, such as photo-ionization sources and X-ray detectors, can also be included. These electrodynamic measurement payloads are about one meter in length and have a mass of about 9 kg. They can be launched with an Orion-class or smaller vehicle.

Croskey, C. L.↗

Magnetic and Langmuir Probe Measurements on the Plasmoid Thruster Experiment (PTX)

The Plasmoid Thruster Experiment (PTX) operates by inductively producing plasmoids in a conical theta-pinch coil and subsequently ejecting them at high velocity. An overview of PTX is described in a companion paper. The shape and magnetic field structure of the translating plasmoids will be measured with of an array of inductive magnetic field probes. Six sets of two B-dot probes (for a total of twelve probes) have been constructed for measuring B(sub z) and B(sub theta), the axial and azimuthal components of the magnetic field. The probes were calibrated with a Helmholtz coil, driven alternately by a high-voltage pulser or a signal generator. The probes are wound on a G-10 form, and have an average (calibrated) NA of 9.37 x 10(exp -5) square meters, where N is the number of turns and A is cross-sectional area. The frequency response of the probes was measured over the range from 1 kHz to 10 MHZ. The electron number density n(sub e), electron temperature T(sub e) and velocity v will be determined from measurements taken with a quadruple Langmuir probe, situated in the exhaust chamber. Three of the four probes on the quadruple probe sample the current-voltage characteristic, and from this yield measurements of T(sub e) and n(sub e). The fourth probe provides a measurement of plasma flow velocity. A 6-inch long alumina rod, hollowed with four holes to house the probe wires, is being used to construct the quadruple probe. A variety of propellants will be used, including hydrogen, nitrogen and argon. From the measurements of the plasmoid mass, density, temperature, and velocity, the basic propulsion characteristics of PTX will be evaluated.

Koelfgen, Syri J.↗

Fluvial to Lacustrine Facies Transitions in Gale Crater, Mars

NASA's Curiosity rover has documented predominantly fluvial sedimentary rocks along its path from the landing site to the toe of the Peace Vallis alluvial fan (0.5 km to the east) and then along its 8 km traverse across Aeolis Palus to the base of Aeolis Mons (Mount Sharp). Lacustrine facies have been identified at the toe of the Peace Vallis fan and in the lowermost geological unit exposed on Aeolis Mons. These two depositional systems provide end members for martian fluvial/alluvial-lacustrine facies models. The Peace Vallis system consisted of an 80 square kilometers alluvial fan with decimeter-thick, laterally continuous fluvial sandstones with few sedimentary structures. The thin lacustrine unit associated with the fan is interpreted as deposited in a small lake associated with fan runoff. In contrast, fluvial facies exposed over most of Curiosity's traverse to Aeolis Mons consist of sandstones with common dune-scale cross stratification (including trough cross stratification), interbedded conglomerates, and rare paleochannels. Along the southwest portion of the traverse, sandstone facies include south-dipping meter-scale clinoforms that are interbedded with finer-grained mudstone facies, interpreted as lacustrine. Sedimentary structures in these deposits are consistent with deltaic deposits. Deltaic deposition is also suggested by the scale of fluvial to lacustrine facies transitions, which occur over greater than 100 m laterally and greater than 10 m vertically. The large scale of the transitions and the predicted thickness of lacustrine deposits based on orbital mapping require deposition in a substantial river-lake system over an extended interval of time. Thus, the lowermost, and oldest, sedimentary rocks in Gale Crater suggest the presence of substantial fluvial flow into a long-lived lake. In contrast, the Peace Vallis alluvial fan onlaps these older deposits and overlies a major unconformity. It is one of the youngest deposits in the crater, and requires only short-lived, transient flows.

Sumner, Dawn Y.↗

Unsteady fan blade pressure and acoustic radiation from a JT15D-1 turbofan engine at simulated forward speed

Tests have been conducted on a JT15D-1 turbofan engine both statically and at simulated forward speed in the Ames 12 x 24 Meter Wind Tunnel. Both far-field acoustic data and unsteady pressure data from transducers mounted on the fan blades were acquired. Results showed a sound power reduction of about 10 dB in the far-field acoustic levels with simulated forward speed over those measured without forward speed. Blade mounted transducer results showed rotor-turbulence interaction dominated the noise field at very low speeds while an interaction between the rotor and internal struts dominated at higher speeds. Results are presented to show the effects of varying engine rpm, changing the angle-of-attack of the engine inlet to tunnel flow and mounting an aircraft wing to simulate an installation condition on an actual aircraft.

Preisser, J. S.↗

Subsonic balance and pressure investigation of a 60 deg delta wing with leading edge devices

Low supersonic wave drag makes the thin highly swept delta wing the logical choice for use on aircraft designed for supersonic cruise. However, the high-lift maneuver capability of the aircraft is limited by severe induced-drag penalties attributed to loss of potential flow leading-edge suction. This drag increase may be alleviated through leading-edge flow control to recover lost aerodynamic thrust through either retention of attached leading-edge flow to higher angles of attack or exploitation of the increased suction potential of separation-induced vortex flow. A low-speed wind-tunnel investigation was undertaken to examine the high-lift devices such as fences, chordwise slots, pylon vortex generators, leading-edge vortex flaps, and sharp leading-edge extensions. The devices were tested individually and in combinations in an attempt to improve high-alpha drag performance with a minimum of low-alpha drag penalty. This report presents an analysis of the force, moment, and static pressure data obtained in angles of attack up to 23 deg, at Mach and Reynolds numbers of 0.16 and 3.85 x 10 to the 6th power per meter, respectively. The results indicate that all the devices produced drag and longitudinal/lateral stability improvements at high lift with, in most cases, minor drag penalties at low angles of attack.

Tingas, S. A.↗

A description of the active and passive sidewall-boundary-layer removal systems of the 0.3-meter transonic cryogenic tunnel

Results are presented for an operational checkout and shakedown of the active sidewall-boundary-layer removal system newly installed in the Langley 0.3-meter Transonic Cryogenic Tunnel (0.3-m TCT). Prior to the installation of this active removal system, the sidewall-boundary layer was removed passively by exhausting directly to the atmosphere (i.e., no reinjection). With the active removal system using the reinjection compressor, the removal capability is greatly expanded to cover the entire operating envelope of the 0.3-m TCT. Details of the active removal system are presented including the compressor reinjection circuit, the compressor pressure ratio/surge control, and the compressor recirculation loop. The control logic and features of the compressor surge control are explained. Initial tests covering critical operating conditions show mass flow removal rates of about 5 percent at lower Mach numbers can be obtained with the active system. Measured performance characteristics of the compressor are presented. As part of the validation of the active system, limited airfoil tests were made using the new system.

Johnson, C. B.↗

Evaluation of Flush-Mounted, S-Duct Inlets With Large Amounts of Boundary Layer Ingestion

A new high Reynolds number test capability for boundary layer ingesting inlets has been developed for the NASA Langley Research Center 0.3-Meter Transonic Cryogenic Tunnel. Using this new capability, an experimental investigation of four S-duct inlet configurations with large amounts of boundary layer ingestion (nominal boundary layer thickness of about 40% of inlet height) was conducted at realistic operating conditions (high subsonic Mach numbers and full-scale Reynolds numbers). The objectives of this investigation were to 1) develop a new high Reynolds number, boundary-layer ingesting inlet test capability, 2) evaluate the performance of several boundary layer ingesting S-duct inlets, 3) provide a database for CFD tool validation, and 4) provide a baseline inlet for future inlet flow-control studies. Tests were conducted at Mach numbers from 0.25 to 0.83, Reynolds numbers (based on duct exit diameter) from 5.1 million to a fullscale value of 13.9 million, and inlet mass-flow ratios from 0.39 to 1.58 depending on Mach number. Results of this investigation indicate that inlet pressure recovery generally decreased and inlet distortion generally increased with increasing Mach number. Except at low Mach numbers, increasing inlet mass-flow increased pressure recovery and increased distortion. Increasing the amount of boundary layer ingestion (by decreasing inlet throat height and increasing inlet throat width) or ingesting a boundary layer with a distorted profile decreased pressure recovery and increased distortion. Finally, increasing Reynolds number had almost no effect on inlet distortion but increased inlet recovery by about one-half percent at a Mach number near cruise.

Berrier, Bobby L.↗

Wall adjustment strategy software for use with the NASA Langley 0.3-meter transonic cryogenic tunnel adaptive wall test section

The Wall Adjustment Strategy (WAS) software provides successful on-line control of the 2-D flexible walled test section of the Langley 0.3-m Transonic Cryogenic Tunnel. This software package allows the level of operator intervention to be regulated as necessary for research and production type 2-D testing using and Adaptive Wall Test Section (AWTS). The software is designed to accept modification for future requirements, such as 3-D testing, with a minimum of complexity. The WAS software described is an attempt to provide a user friendly package which could be used to control any flexible walled AWTS. Control system constraints influence the details of data transfer, not the data type. Then this entire software package could be used in different control systems, if suitable interface software is available. A complete overview of the software highlights the data flow paths, the modular architecture of the software and the various operating and analysis modes available. A detailed description of the software modules includes listings of the code. A user's manual is provided to explain task generation, operating environment, user options and what to expect at execution.

Wolf, Stephen W. D.↗

Preliminary cryogenic performance of the Shuttle Infrared Telescope Facility

The Shuttle Infrared Telescope Facility (SIRTF) is a cryogenically cooled telescope in the one-meter aperture class designed for sensing in the infrared from 2-200 microns. This facility is designed to be flown many times on the Space Shuttle with varying instrument complements. All components of the SIRTF within the field of view of the optics are cryogenically cooled. The primary coolant is supercritical helium which is stored in an external tank and routed through the telescope - cooling the instruments first, then the optical components and finally the baffles. For detector cooling below 6K small reservoirs of superfluid helium (He II) are provided. The SIRTF cryogenic system is designed to automatically control the tank pressure and telescope flow rates during prelaunch operations and flight as well as meet the Space Shuttle environmental and safety requirements. Temperatures maintained in the telescope are a function of instrument operation, design, energy dissipation, and telescope pointing angle. By control of the cryogen flow rate any selected instrument temperature can be maintained within fixed limits, and the critical secondary mirror can be maintained below 10K throughout a 14-day mission. Instrument thermal design is a critical factor in the maintenance of proper temperature differences in the experiment package. Design of a cryogenic telescope for space use presents many problems which do not exist in earth based systems. The limited opportunity for servicing, the restricted coolant supply, and the remote instrumentation and control all provide new considerations for the instrument and system designers.

Gier, H. L.↗

Free stream noise and transition measurements in a Mach 3.5 pilot quiet tunnel

Free stream fluctuating pressures are determined from hot-wire measurements in a Mach 3.5 pilot quiet nozzle over a unit Reynolds number range from 10-60 million per meter. Further, the transition Reynolds numbers on a sharp tip 5 degree half-angle cone at zero angle of attack are obtained over the same range of unit Reynolds numbers from equilibrium temperature measurements on the cone. Results show that the nozzle provides noise levels in the upstream regions of the test rhombus that are substantially lower than in conventional nozzles. The normalized rms levels of the fluctuating static pressures are found to vary from extremely low values of less than 0.03% up to about 0.8% depending on the unit Reynolds number, the axial location in the test rhombus, and the bleed slot flow. By opening the boundary-layer bleed flow, the wall boundary layers over upstream regions of the nozzle become laminar and the absence of high frequency radiated noise then results in cone transition Reynolds numbers that are in the range of free-flight data. As the unit Reynolds numbers are increased, the nozzle wall boundary layers become transitional and turbulent, and the noise increases to peak levels of about 0.5% with significant energy up to 150 KHz. The cone transition Reynolds numbers then decrease to values that are in the range of those measured in conventional wind tunnels.

Beckwith, I. E.↗