Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flexible power generation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Business Models for Scaling Demand Flexibility Volume II – Customer relationship management strategies, challenges, and lessons learned from U.S. programs

Load growth at the grid edge is driving increased attention to the distribution system and its ability to enable customer technology adoption in an affordable and timely manner. Key industry stakeholders, including electric utilities and regulators, can benefit from strategies to manage and balance customer needs with infrastructure investments, such as demand flexibility. This report focuses on demand flexibility—the ability to reduce, shift, shed, generate, or modulate loads in response to building and grid needs—to reduce the need for costly grid upgrades by deferring investment needs and increase system reliability by shifting electricity usage during periods of high risk. Specifically, we focus on the emerging characteristics of business models for demand flexibility as a framework to understand how demand flexibility programs generate value. In this report, we focus on demand flexibility program customer relationship management strategies, which provide information on value creation and focus on ensuring customers can navigate programs smoothly. This report discusses the role of customer relationship management strategies in demand flexibility programs, characterizes customer relationship management strategies that can be considered during program design and implementation, identifies existing challenges to customer relationship management strategies, and describes lessons learned. This report is part of a series that includes reports on value propositions, stakeholder ecosystem management, and program life cycle.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Managing Solar Photovoltaic Integration in the Western United States: Resource Adequacy Considerations

This study examines the impact of reserve margin-based reliability assessment, as commonly used in capacity expansion models, on planning resource-adequate power systems under high penetrations of solar photovoltaics (PV). As a generation resource, PV is operationally different from the conventional dispatchable resources for which most capacity expansion models were designed. The question this study attempts to answer is whether large amounts of PV on a system (in this case, the Western Interconnection of North America) would bias the results of conventional reserve margin-based capacity expansion modeling towards an over- or under-provisioning of resource adequacy. This analysis used NREL’s Resource Planning Model (RPM) for capacity expansion modeling and NREL’s Probabilistic Resource Adequacy Suite (PRAS) for resource adequacy assessment. RPM uses a reserve margin requirement to enforce resource adequacy. PRAS, a collection of tools for studying the resource adequacy of power systems and the adequacy contributions of individual resources on a probabilistic basis, was used to compute multiple resource adequacy metrics across a number of simulated scenarios and system representations with differing regional detail. In all cases, including high PV penetrations (up to 33% annual generation from PV, interconnection-wide), RPM was able to produce resource-adequate systems as measured by normalized expected unserved energy and loss-of-load expectation results from PRAS. The accuracy of reserve margin approaches depends heavily on the underlying assumptions informing the capacity credit assigned to variable and energy-limited resources, particularly when such resources are abundant in the modeled system. RPM’s standard methodology for estimating variable and flexible resources’ capacity contributions, which is based on the top 100 hours of net load, did not appear to systematically undervalue or overvalue variable generation relative to a more rigorous equivalent firm capacity assessment using PRAS, although both over- and under-valuations were observed in specific scenarios. In the worst cases, the top 100 hour method underestimated the equivalent firm capacity of PV by two percentage points, and overestimated the equivalent firm capacity of PV by five percentage points. Calculating capacity contributions based on the top 10 hours of net load systematically underestimated equivalent firm capacities at more modest PV penetrations, but was often a better approximation of equivalent firm capacity than the existing 100-hour approach in scenarios with higher PV penetrations.

14 SOLAR ENERGY↗

From the Rocket Equation to Maxwell's Equations: Electrodynamic Tether Propulsion Nears Space Test

The US space program is facing a growing challenge to its decades-long, global leadership position, as current launch costs consume valuable resources and limit achievements in science, exploration, and commercial development. More than 40% of projected launches over the next 10 years have payloads with intended destinations beyond low-Earth orbit. Therefore, more cost-effective upper stages and on-board propulsion systems are critical elements in reducing total space transportation costs. A new type of space propulsion, using electrodynamic tethers, may be capable of performing multiple sequential missions without resupply and have a potential usable lifetime of several years. They may provide an in-space infrastructure that has a very low life cycle cost and greatly enhanced mission flexibility, thus supporting the goal of reducing the cost of access to space. Electrodynamic tether thrusters work by virtue of the force the Earth's magnetic field exerts on a wire carrying an electrical current. The effect is the basis for electric motors and generators. The Propulsive Small Expendable Deployer System (ProSEDS) experiment, planned for launch in the summer of 2000, will demonstrate the use electrodynamic tether thrust by lowering the altitude of a Delta-H rocket's upper stage on which it will be flying. Applications of the technology include a passive deorbit system for spacecraft at their end-of-life, reusable Orbit Transfer Vehicles, propellantless reboost of the International Space Station, and propulsion and power generation for future missions to Jupiter.

Johnson, Les↗

Europa Mission Configuration Update to Accommodate Maturing Instrument Designs

A mission to Jupiter’s moon, Europa has been of interest to NASA and JPL since the Galileo mission's magnetometer data predicted the presence of a subsurface ocean. The planned Europa mission would be equipped with a suite of instruments to perform both remote and in-situ sensing, the scope of which ranges from gravity science to characterizing the surface composition, with one of the objectives being to confirm the existence of the subsurface ocean. As the selected instruments mature, the challenge has been to select and refine a spacecraft configuration that is flexible enough to accommodate these changes without degrading the scientific capability of the spacecraft. An increase in instrument volume and power have prompted the growth of spacecraft engineering subsystems, which include the solar arrays and the avionics module. These changes have the potential to cause obstructions to the instrument fields of view, stray light keep-out-zones, and thermal radiative fields of view. Many of these criteria are addressed by the implementation of a dedicated instrument platform. Payloads that are unique to the Europa mission require new approaches to instrument accommodation, such as coupling the ice penetrating radar's radiating elements to the solar array. This paper will discuss these accommodation strategies for the Europa spacecraft to generate a new baseline design.

Gentile, Matthew↗

A 1.2-V 6-GHz Dual-Path Charge-Pump PLL Frequency Synthesizer for Quantum Control and Readout in CMOS 65-nm Process

This paper presents a low jitter dual-path chargepump phase locked loop (PLL) synthesizer in a CMOS 65-nm process for quantum readout applications. The PLL incorporates a programmable dual chargepump and a loop filter with both proportional and integral paths that can be driven independently providing flexible control of the loop bandwidth to achieve low jitter performance. The design is implemented at 300 K and critical blocks like voltage-controlled oscillator (VCO) and chargepump (CP) are analyzed at 77 K based on the characterized results. The LC-VCO is realized with the class-C NMOS only architecture with 5-bit coarse control and quadrature signals are generated with poly phase filter. The VCO is designed with the tuning range of 1 GHz around the center frequency of 6 GHz with Phase Noise of -123 dBc/Hz and -132 dBc/Hz at 1MHz offset at 300 K and 77 K temperature. The simulated PLL rms jitter is 125 fs at 6 GHz with a power consumption of 8 mW at the 1.2 V power supply.

47 OTHER INSTRUMENTATION↗

Voltage Optimization

Voltage optimization refers to a volt-var optimization technique which was originally designed to minimize energy consumption and improve end-use efficiency on the distribution system. This reduces source voltage at a substation, which lowers generation demand, reduces system losses, and improves system stability. This has been the conventional implementation of voltage optimization: focusing on regulation of voltages throughout the distribution system via coordinated adjustments of load tap changers, line-voltage regulators, switched shunt compensation, and the targeted placement of new shunt compensation. These methods have received increased focus following a growth in distributed-energy resources (DERs) interconnecting at the distribution level, given their developing capability to participate in voltage regulation. This is paired with the intermittency challenges they pose, load imbalances, and voltage fluctuations. Voltage optimization has long been an area of extensive research within the distribution system, with various strategies and philosophies demonstrating a range of effects. The conventional focus on the distribution system owes to the typical operation of transmission systems, which assumes firm local resources and flows strictly from generation resources to loads. The strategies employed in distribution have also been optimized for this typically radial configuration and operation of the distribution system.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Rethinking the Price Formation Problem–Part 2: Rewarding Flexibility and Managing Price Risk

In this study, part 1 of this two-part paper describes the impact that uncertainty has on the design and analysis of price formation policies in the non-convex auctions conducted by U.S. wholesale electricity market operators. Using first a toy model and then a large-scale test system, Part 2 demonstrates the difference in prices under the idealized benchmark of ex ante convex hull pricing defined in Part 1 versus existing methods, in particular documenting the potential for suppression of volatility and therefore under-compensation of flexibility by existing methods. The examples highlight that inefficient spot price formation can induce inefficient forward commitments of generators, necessitating out-of-market intervention to restore a reliable and efficient operating plan.Given the potential side effects of existing policies for investment and operation, we suggest two elements in a reoriented approach to the price formation problem: first ensuring that prices exhibit full-strength volatility, and second ensuring that risk-averse market participants have sufficient ability to manage this volatility.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Laser-assisted high-energy proton pulse extraction for feasibility study of co-located muon source at the SNS

Here, we have experimentally demonstrated the first non-intrusive 1-GeV proton beam extraction for the generation of muons with a temporal structure optimized for Muon Spin Relaxation/Rotation/Resonance (μSR) applications. The proton pulses are extracted based on the laser neutralization of 1 GeV hydrogen ion (H - ) beam in the high energy beam transport of the Spallation Neutron Source (SNS) accelerator. The maximum flux of the extracted proton beam based on laser neutralization causes only 0.2% reduction of the total proton beam used for neutron production, a marked difference from the 20% reduction at other co-located muon and neutron facilities, and thus the proposed method will result in negligible impact on the SNS operation. This paper describes the development of a fiber/solid-state hybrid laser system that has high flexibility of pulse structure and output power, initial experiments on laser neutralization of beam and separation of H 0 beam from the existing SNS accelerator beam line, conversion of H 0 to proton at the SNS linac dump, and measurement results of 30 ns/50 kHz proton pulses. This system conclusively demonstrates the feasibility of laser-based proton beam extraction to power a world-leading μSR facility at the SNS.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tri-Level Scheduling Model Considering Residential Demand Flexibility of Aggregated HVACs and EVs Under Distribution LMP

Residential loads, especially heating, ventilation and air conditioners (HVACs) and electric vehicles (EVs), have great potentials to provide demand flexibility which is an attribute of grid-interactive efficient buildings (GEB). Under this new paradigm, first, EV and HVAC aggregator models are developed in this paper to represent the fleet of GEBs, in which the aggregated parameters are obtained based on a new approach of data generation and least squares parameter estimation (DG-LSPE), which can deal with heterogeneous HVACs. Then, a tri-level bidding and dispatching framework is established based on competitive distribution operation with distribution locational marginal price (DLMP). Furthermore, the first two levels form a bilevel model to optimize the aggregators’ payment and to represent the interdependency between load aggregators and the distribution system operator (DSO) using DLMP, and the third level is to dispatch the optimal load aggregation to all residents by the proposed priority list-based demand dispatching algorithm. Finally, case studies on a modified IEEE 33-Bus system illustrate three main technical reasons of payment reduction due to demand flexibility: load shift, DLMP step changes, and power losses. They can be used as general guidelines for better decision-making for future planning and operation of demand response programs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

OpenMC

OpenMC is an open source, community-developed framework for performing Monte Carlo particle transport calculations.It is capable of simulating neutron and photon transport below ~50 MeV and also includes a model for bremsstrahlung production of photons by electrons/positrons. Fixed source, k-eigenvalue, and subcritical multiplication problems can be solved. Problem geometries can be modeled either using constructive solid geometry or a CAD representation. A flexible and efficient tally system enables a wide variety of physical quantities to be tallied and analyzed. OpenMC can run in parallel using a hybrid MPI and OpenMP programming model and has been extensively tested on leadership class supercomputers. A built-in Bateman equation solver enables the modeling of material composition changes due to irradiation. One of the unique features of OpenMC is its rich, extensible Python and C/C++ programming interfaces that enable programming pre- and post-processing, multigroup cross section generation, workflow automation, multiphysics coupling, and the visualization of geometry and tally results. In addition to the core Monte Carlo transport solver and associated APIs, OpenMC includes a Python-based nuclear data interface that enables power users to inspect, modify,and perform various types of nuclear data processing on ENDF, ACE, and OpenMC¿s native HDF5 files

ROMANO, PaulK.↗

Efficient Refrigerated Display Cases - Can They Flex Their Power? Preprint

Refrigerated display cases are widely-used, critical equipment in supermarkets for maintaining product safety and quality. Energy-efficient medium temperature liquid-cooled refrigerated display cases can save 25-70% of the total supermarket energy, according to manufacturers. Traditionally, cases operate by maintaining a temperature around a user-input setpoint that is dependent on the product in the case. Although cases are major electrical energy consumers, they are hardly ever considered for implementing load-flexibility strategies. With added load-flexibility capabilities, refrigerated display cases can shed (reduce), or shift (by adding and subsequently shedding) load. Supermarkets can reduce their energy costs and enhance electric grid integrity by implementing these smart load-flexibility control strategies. Advanced controls can also enable load-shifting to coincide with optimum periods of renewable energy generation. This will further improve operational costs and reduce greenhouse gas emissions without compromising food safety and quality. In this research, we have evaluated the energy savings of liquid-cooled medium temperature display cases and developed load flexibility strategies leveraging an advanced controls system, a variable speed compressor, and heat rejection via a water-cooled condenser. This study further assessed the impact of load flexibility strategies in a controlled environment chamber for a single refrigerated display case.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Agent-Based Distributed Energy Resources for Supporting Intelligence at the Grid Edge

This article proposes a novel multi-agent framework that can link various forms of resources and power electronic systems into distributed energy resources (DER). The proposed multiagent architecture can also integrate DERs to a central controller for optimization and control to support the grid. To demonstrate the flexibility of this novel framework, the developed agent system is applied to a set of end-use systems. Furthermore, the agent framework is validated in hardware using controller-hardware-in-the-loop simulation platform.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advanced Micro Combined Heat and Power Device

U.S. buildings account for approximately 40% of total U.S. energy consumption and 75% of electricity use, emphasizing the need for efficient, resilient, and secure energy solutions. Micro-combined heat and power (micro-CHP) systems provide an effective approach by simultaneously generating electricity and recovering waste heat for thermal use. However, current commercial micro-CHPs face challenges in achieving higher efficiency, lower emissions, and reduced cost. To address these limitations, a novel micro-CHP prototype powered by a unique opposed-piston four-stroke (OP4S) engine was developed. The OP4S features a simplified, low-cost design with reduced heat losses and dual-piston operation that enables higher thermal efficiency. Experimental results demonstrated up to 35.2% AC electrical efficiency under lean combustion, surpassing the best-performing ICE-based micro-CHPs reported publicly. In addition, the micro-CHP enables a total CHP efficiency exceeding 93%. The prototype operates reliably for over 600 hours, providing flexible and efficient thermal and electrical outputs. This novel OP4S-based micro-CHP offers a resilient, low-cost, and energy-efficient solution suitable for residential, light commercial, and remote community applications across diverse climate zones.

Gao, Zhiming [ORNL] (ORCID:0000000271397995)↗

Hybridization Assessment of Trybrid Pumped Storage Hydropower System—Part 1: A Case Study of Corral Summit

This report is a part of the deliverables for technical assistance provided to Cat Creek Energy for the Coral Summit Trybrid (Triple Hybrid-Pumped Storage Hydropower, Battery Energy Storage System, and photovoltaic solar energy) energy project. This report explores the operational benefits and challenges of hybridizing an open loop PSH (200MW) located at Mackay, Custer County, Idaho with solar PV (Ground mount 300MW and floating 40MW) and battery (720MWhr). This document reports two activities performed as a part of the hybridization assessment task 1) optimal resource allocation and energy management strategy, and 2) power quality and reliability assessment. From optimal resource allocation and energy management strategy (activity 1), the following key findings can be observed: • Conventional PSH (CPSH) with two reversible pump turbines and separate penstocks can provide required flexibility equivalent to that from two ternary PSH with separate penstock. With single unit CPSH, upper reservoir head cannot be maintained accurately, the variation of water level is rapid and pump mode flexibility is not available. These disadvantages can be overcome by single unit TPSH. However, using two CPSH units with separate penstocks also overcome these disadvantages with the formation of the hydraulic short circuit between two conventional units. • Flooding of the lower reservoir is a severe concern when considering continuous operation for black start. This limits the duration of continuous operation from PSH alone to around 50 hours. Due to the complementary PV and battery action, the duration of continuous operation and smooth power output can be extended. • An optimization problem is framed that maximizes the power output on an hourly basis while minimizing constraint violations and respecting seasonal variations of solar PV and load profiles . Two value streams, arbitrage and baseload generation are served by this profile. It was uncovered that for smooth power output during regular operation, PV curtailment will be required, or the battery capacity needs to be increased above 90MW to accommodate additional PV. From power quality and reliability assessment (activity 2) the following takeaway points can be observed: • The Trybrid, when integrated at the Lost River bus, and limited to 250MW in generation mode and -150MW in the pump mode, causes no violation of voltage or flow.

13 - HYDRO ENERGY↗

Pressurized Lunar Rover (PLR)

The objective of this project was to design a manned pressurized lunar rover (PLR) for long-range transportation and for exploration of the lunar surface. The vehicle must be capable of operating on a 14-day mission, traveling within a radius of 500 km during a lunar day or within a 50-km radius during a lunar night. The vehicle must accommodate a nominal crew of four, support two 28-hour EVA's, and in case of emergency, support a crew of six when near the lunar base. A nominal speed of ten km/hr and capability of towing a trailer with a mass of two mt are required. Two preliminary designs have been developed by two independent student teams. The PLR 1 design proposes a seven meter long cylindrical main vehicle and a trailer which houses the power and heat rejection systems. The main vehicle carries the astronauts, life support systems, navigation and communication systems, lighting, robotic arms, tools, and equipment for exploratory experiments. The rover uses a simple mobility system with six wheels on the main vehicle and two on the trailer. The nonpressurized trailer contains a modular radioisotope thermoelectric generator (RTG) supplying 6.5 kW continuous power. A secondary energy storage for short-term peak power needs is provided by a bank of lithium-sulfur dioxide batteries. The life support system is partly a regenerative system with air and hygiene water being recycled. A layer of water inside the composite shell surrounds the command center allowing the center to be used as a safe haven during solar flares. The PLR 1 has a total mass of 6197 kg. It has a top speed of 18 km/hr and is capable of towing three metric tons, in addition to the RTG trailer. The PLR 2 configuration consists of two four-meter diameter, cylindrical hulls which are passively connected by a flexible passageway, resulting in the overall vehicle length of 11 m. The vehicle is driven by eight independently suspended wheels. The dual-cylinder concept allows articulated as well as double Ackermann steering. The primary power of 8 kW is supplied by a dynamic isotope system using a closed Brayton cycle with a xenon-hydrogen mixture as the working fluid. A sodium-sulfur battery serves as the secondary power source. Excess heat produced by the primary power system and other rover systems is rejected by radiators located on the top of the rear cylinder. The total mass of the PLR 2 is 7015 kg. Simplicity and low total weight have been the driving principles behind the design of PLR 1. The overall configuration consists of a 7-m-long, 3-m-diameter cylindrical main vehicle and a two-wheeled trailer. The cylinder of the main body is capped by eight-section, faceted, semi-hemispherical ends. The trailer contains the RTG power source and is not pressurized. The shell of the main body is constructed of a layered carbon fiber/foam/Kevlar sandwich structure. Included in the shell is a layer of water for radiation protection. The layer of water extends from the front of the rover over the crew compartment and creates a safe haven for the crew during a solar flare-up. The carbon fiber provides the majority of the strength and stiffness and the Kevlar provides protection from micrometeoroids. The Kevlar is covered with a gold foil and multi-layer insulation (MLI) to reduce radiation degradation and heat transfer through the wall. A thin thermoplastic layer seals the fiber and provides additional strength.

Creel, Kenneth↗

Hierarchical Control and Stability Analysis for a Nonisolated Grid-Tied DC Energy Router Integrating Energy Storage and Partial Distributed Generation

This article proposes a nonisolated dc converter-based energy router (dc-ER) and its operating strategy. Here, the intent is to integrate energy storage (ES), distributed generation (DG), local load, and dc power grid in an autonomous and more efficient way. The ES/DG power ports are coupled with each other in partial-type connections, which obtains higher voltage supply gain and direct input–output power transmission. High-voltage supply gain allows a wide solar power tracking range and the possibility of optimal battery charging/discharging. Direct input–output power transmission improves the energy conversion efficiency. In this article, the operating modes of dc-ER are first analyzed, followed by the optimal hardware design counting the DG current ripple minimization and the limitation caused by the power flow direction. Second, the mathematical model of dc-ER is deduced. The hierarchical control is then proposed to manage port energy in a flexible manner. The stability is analyzed by using impedance modeling. Finally, experimental and simulation results verify the superiorities of the proposed topology in terms of flexible operating mode transition and high-power conversion efficiency.

25 ENERGY STORAGE↗

Business Models for Scaling Demand Flexibility Volume IV – Program life cycle challenges and lessons learned from U.S. programs

Load growth at the grid edge is driving increased attention to the distribution system and its ability to enable customer technology adoption in an affordable and timely manner. Key industry stakeholders, including electric utilities and regulators, can benefit from strategies to manage and balance customer needs with infrastructure investments, such as demand flexibility. This report focuses on demand flexibility—the ability to reduce, shift, shed, generate, or modulate loads in response to building and grid needs—to reduce the need for costly grid upgrades by deferring investment needs and increase system reliability by shifting electricity usage during periods of high risk. Specifically, we focus on the emerging characteristics of business models for demand flexibility as a framework to understand how demand flexibility programs generate value. In this report, we focus on the life cycle of demand flexibility programs, which provides information on value creation and describes the various deployment phases program implementers navigate from initial program conceptualization through to program expansion and replication to new customer segments and regions. This report characterizes the key phases of the demand flexibility program life cycle, identifies existing challenges across the program deployment phases, and describes lessons learned. This report is part of a series that includes reports on customer relationship management strategies, stakeholder ecosystem management, and program life cycle.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Energy Flexibility-Environmental Outcomes Tradeoffs Workshop Report and Research Roadmap

The U.S. Department of Energy (DOE) and Norway’s Royal Ministry of Petroleum and Energy signed an Annex to a previously signed memorandum of understanding (MOU) in February 2020 to collaborate on hydropower research and development (R&D). This MOU Annex has brought together the DOE’s Office of Energy Efficiency and Renewable Energy Water Power Technology Office and the Norwegian Research Center for Hydropower Technology (HydroCen) to plan and coordinate hydropower R&D activities to increase our understanding of hydropower’s role in the future energy grid and how to minimize and mitigate the subsequent environmental impacts. As part of this MOU Annex, hydropower researchers from the U.S. and Norway have come together to conduct collaborative research on hydropower markets and value, hydropower plant capabilities and constraints, monitoring and control technologies, environmental design solutions, environmental impacts and tradeoffs, flexible operation and planning, and technology innovations. This report presents background information on hydropower environmental regulation in the U.S. and Norway and summarizes content and conclusions from this series of two, three-hour workshops on hydropower generation flexibility and environmental outcomes, that included structured discussions used to identify research priorities and collaborative research opportunities.

13 HYDRO ENERGY↗