Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fibers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Pressure-Driven Fiber-Optic Sensor for Online Corrosion Monitoring

For many industrial applications, corrosion is a life-limiting phenomenon and therefore requires careful consideration and rigorous experimental testing before structural materials can be reliably deployed, particularly in harsh chemical environments. The traditional approach to measuring corrosion requires exposing many samples to the intended environment and then extracting them individually at discrete intervals for postexposure characterization. This approach does not provide a high degree of temporal resolution, nor does it provide any real-time information regarding dynamic changes in corrosion rates. Additionally, developing an online corrosion monitor capable of surviving harsh chemical environments could provide valuable information regarding the structural health of components and changing process conditions that could accelerate corrosion. To this end, a corrosion sensor was developed based on a pressure-driven Fabry-Pérot cavity (FPC). This sensor uses a pressure control system to internally pressurize the FPC formed between the sensor’s housing and a metal-embedded singlemode optical fiber. Simultaneous measurement of the change in FPC length using low-coherence interferometry and the applied pressure enables the calculation of the relative changes in the sensor’s diaphragm thickness due to corrosion on its outer surface. Measurements were made in situ while actively corroding the sensor and were validated against surveillance specimens that were corroded simultaneously. The uncertainties in the measured corrosion were analyzed using error propagation of the uncertainties in the measured pressures and displacements and were found to be <1% of the initial diaphragm thickness.

42 ENGINEERING↗

Utah FORGE: Neubrex Well 16B(78)-32 Fiber Optics Reports - Stimulation and Circulation, 2024

This zip file contains reports discussing the use of fiber optics during well 16B(78)-32 stimulation and circulation tests in the summer of 2024. The reports cover the collection of strain rate and temperature change data during these well events. Theory, methods, and initial data visualizations are included in the reports, highlighting the value of these data types.

15 GEOTHERMAL ENERGY↗

Fiber Optic Distributed Acoustic Sensing in DFPS East Well

Fiber optic files in *.hdf format, acquired in the Devine Fracture Pilot Site East well, using Fotech interrogator. There was no change in channel spacing or acquisition settings during the project. Channel spacing is 0.68 m.

Electrically active proppant,Electromagnetic,Fiber↗

Literary review and modeling outlook for radiation damage in fused-silica optical fibers

The purpose of this document is to distill, from literature, the effects of radiation damage in fused-silica optical fibers. This information will be used to design a theoretical framework capable of predictive modeling that will be published elsewhere. By inspection of the relevant literature, the devised method is calculation of defect amorphous structures by molecular dynamic techniques, and computation of the macroscopic dielectric function using density functional theory. The dielectric function is then used to directly compute the transmittance of the core material before and after irradiation via solution of Maxwell’s equations in a homogeneous medium.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Laboratory and In-Pile Testing of a Fiber Optic Pressure Sensor

The development, testing and deployment of a fiber-optic-based extrinsic Fabry-Perot pressure sensor is discussed. The details of design and fabrication procedure is discussed and the methodology for design decisions is provided. Results from laboratory-based testing and calibration is provided as-well-as preliminary data from in-pile testing in the Transient Reactor Test Facility.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fe-Coated Optical Fiber for Distributed Corrosion Monitoring in Soil and Aqueous Environments

Natural gas pipeline corrosion represents a substantial cost and safety concern during normal operations. The effective and real-time monitoring of corrosion is important to detect and mitigate pipeline risks before corrosion-related catastrophic events happen. Here, we describe the use of iron (Fe) coated optical fiber sensors (OFS) for distributed corrosion monitoring where Fe acts as a corrosion proxy. By using an optical backscattering reflectometer (OBR), corrosion was monitored based on the increase in the backscattered intensity amplitude of the light being passed as Fe underwent corrosion. The Fe-coated OFSs were prepared with a film thickness between 25–225 nanometers (nm) by an electroless plating approach and corroded by a carbon dioxide (CO2)-saturated acidic electrolyte. The corrosion rate (CR) was approximately 2.5 millimeters (mm)/year for Fe with a film thickness of 30 nm and increased with film thickness. Backscattering-based CRs were supported by visible light transmission measurements, which have been previously demonstrated. Additionally, a correlation between the intermittent transmission and residual Fe film thickness during the corrosion of Fe was established. The corrosion was measurable out to > 100 meters (m), which is a significant improvement over our previous work, which showed corrosion sensing at < 10 m. The corrosion sensor was also tested in soil at > 1 foot depth.

corrosion↗

Hydrogen Detection via a Low-Cost Prototype Fiber-Optic Sensing System

The developed low-cost prototype sensing system successfully detects hydrogen concentrations across a wide range, demonstrating immediate feasibility for commercial deployment. Utilizing fiber-optic technology, the system delivers stable, reproducible performance from parts-per-million levels up to 100% pure H2 environments. Environmental and chemical cross-sensitivity evaluations confirm robust selectivity against methane and temperature changes, establishing its readiness for near-term commercialization.

fiber-optic H2 sensor↗

Fiber-Optic Raman Probe for On-line EAF Slag Analysis

Here, in Electric Arc Furnace (EAF) steelmaking, the push for improved efficiency requires accurate analysis of the chemical composition of its slag system to control slag foaming, provide refractory protection, and maintain high furnace iron yield. Therefore, the ability to obtain real-time slag chemistry data would provide a useful tool to improve the control and efficiency of the process. The work reported here aims to assess the structure and chemistry of EAF slags at high temperatures using a portable fiber-optic Raman probe. As a result, the ability to relate Raman spectra peaks to chemistry and structure is demonstrated in experimental result with EAF slags at 1550°C.

47 OTHER INSTRUMENTATION↗

Enhanced Bottom Anode Monitoring in DC Electric Arc Furnaces Using Fiber-Optic Sensors

A pin style bottom anode employs conductive steel rods that serve as the pathway for the high electrical power through rammed refractory at the bottom of a DC Electric Arc Furnace (EAF). Anode wear during operation is important to monitor, as anode replacement is expensive and impacts EAF productivity. Liquid steel penetration into the un-sintered refractory layer can result from rapid electrical power ramp-up, dips in furnace temperature, or operating the anode for too long between EAF campaigns. In extreme cases, the liquid steel may penetrate the bottom of the furnace when anode wear progresses too close to the bottom shell, which is extremely dangerous and must be avoided. The current state of the art for monitoring bottom anode wear employs thermocouples imbedded in the anode pins at points in the anode. However, this approach is not sensitive enough to detect localized damage to the anode, especially when cracking occurs. Here, the present work utilizes fiber optic sensors to monitor the health of the anode, by creating a real-time spatially distributed temperature map of the anode. Unlike the traditional thermocouples, these sensors can be mounted at significantly greater depths, provide distributed temperature measurements, and can withstand temperatures of up to 900°C. Additionally, they are able to perform temperature measurements with a spatial resolution of 1.3 mm at a 5 Hz acquisition rate, providing unprecedented high-density real time monitoring of anode health and increasing the efficiency, and safety of EAF operation.

Bottom Anode↗

Dynamic Heat Flow and Current Distribution Analysis in the Bottom Anode of an Electric Arc Furnace Using Fiber-Optic Sensors

A reliable method for monitoring bottom anode wear during DC Electric Arc Furnace (DC-EAF) operation is of critical importance for safe and efficient steel production. Underestimation of bottom wear poses a serious safety risk that must be avoided, while overestimation of bottom wear also poses challenges, as premature anode replacement is expensive and affects EAF productivity. Previously, we demonstrated that fiber-optic sensors can be successfully deployed to create a spatially distributed temperature map to monitor the health of the anode. The present work explores the heat flow and current density distribution in bottom anode pins to predict bottom wear, steel penetration events, and monitor refractory erosion. Small dynamic variations in pin temperature induced by joule heating during arcing also provide a means to observe local current flows in each pin. When mapped, these measurements provide a real-time view of the non-uniform and dynamic current flow in the bottom anode during EAF operation that can affect bottom wear.

Bottom Anode↗

The Effect of a Carbon Fiber Layer Between the Cathode and the Current Collector on Battery Cell Performance

Contact resistance between the cathode active material (CAM) and the Al current collector can be reduced by applying carbon coatings to the Al current collector surface. However, this process requires an additional step of carbon layer coating on the current collector, which increases both manufacturing costs and processing time. In the present work, an interlayer of continuous unsized carbon fibers aligned in one direction (CF interlayer), is introduced between the Al current collector and the NMC811 cathode during cathode deposition on the Al current collector. This single-step approach eliminates the need for the additional carbon layer coating on the current collector. Additionally, this approach removes the use of toxic solvents and insulative polymers used for making the carbon coating. The CF interlayer improves the rate capability at higher C-rates. The CF interlayer lowers the contact resistance between the cathode particles and the current collector while improving the activation energy of charge transfer. The peel test showed that the CF interlayer does not affect the adhesion strength of the cathode layer with the current collector.

25 ENERGY STORAGE↗

Mitigation of Galvanic Corrosion in Bolted Joint of AZ31B and Carbon Fiber-Reinforced Composite Using Polymer Insulation

The use of polymer insulation to mitigate galvanic corrosion was examined for bolted joints of AZ31B Mg alloy and carbon fiber-reinforced composite. To assess the corrosion behaviors of bolted joints with and without polymer insulation, solution immersion and salt spray exposure (ASTM B117) tests were conducted, and the corrosion depths and volumes were determined for the joint specimens after the tests. The polymer-insulated bolted joints exhibited much lower corrosion depths and volumes, highlighting the effective mitigation of galvanic corrosion. The reductions of joint strength in the post-corrosion joint specimens were relatively small (up to ~10%) in the polymer-insulated group but greater (up to 90%) in the group with no insulation. Cross-sectional characterization of post-corrosion joints with polymer insulation revealed local pits developed on AZ31B under galvanic influence, indicating that limited galvanic attack (that did not decrease the joining integrity significantly) could still occur during a long salt spray exposure (~1264 h) owing to the permeation of an aqueous corrosive medium.

36 MATERIALS SCIENCE↗

Flue Gas Desulfurization (FGD) Wastewater Treatment Using Polybenzimidazole (PBI) Hollow Fiber (HF) Membranes

Polybenzimidazole (PBI) hollow fiber membranes were used to treat flue gas desulfurization (FGD) wastewater (WW) from a coal fired power plant. Membranes were tested using both single salt solutions and real FGD WW. The PBI membranes showed >99% rejection for single salt solutions of NaCl, MgCl2, CaSO4, and CaCl2 at approximately 2000 PPM (parts per million). The membranes also showed >97% rejection for FGD WW concentrations ranging from 6900 to 14,400 PPM total dissolved solids (TDS). The pH of the FGD WW was adjusted between 3.97–8.20, and there was an optimal pH between 5.31 and 7.80 where %rejection reached a maximum of >99%. The membranes were able to operate stably up to 50 °C, nearly doubling the water flux as compared to room temperature, and while maintaining >98% salt rejection.

activation energy↗

Sequestering Rare Earth Elements and Precious Metals from Seawater Using a Highly Efficient Polymer Adsorbent Derived from Acrylic Fiber

An amidoxime and carboxylate containing polymer adsorbent derived from acrylic fiber has shown extremely high efficiencies for extracting critical materials and precious metals from seawater. Among 50 extractable elements, the lanthanides, cobalt, and palladium were ranked near the top with KD values in the order of 107, about an order of magnitude higher than that of uranium. The KD value of the lanthanides increased linearly with the atomic number indicating charge density is a factor controlling trivalent lanthanide extractability in seawater. The data given in this report provides crucial information regarding the strategies of ocean mining of critical materials and precious metals.

36 MATERIALS SCIENCE↗

Active Compensation of Radiation Effects on Optical Fibers for Sensing Applications

Neutron and gamma irradiation is known to compact silica, resulting in macroscopic changes in refractive index (RI) and geometric structure. The change in RI and linear compaction in a radiation environment is caused by three well-known mechanisms: (i) radiation-induced attenuation (RIA), (ii) radiation-induced compaction (RIC), and (iii) radiation-induced emission (RIE). These macroscopic changes induce errors in monitoring physical parameters such as temperature, pressure, and strain in optical fiber-based sensors, which limit their application in radiation environments. We present a cascaded Fabry–Perot interferometer (FPI) technique to measure macroscopic properties, such as radiation-induced change in RI and length compaction in real time to actively account for sensor drift. The proposed cascaded FPI consists of two cavities: the first cavity is an air cavity, and the second is a silica cavity. The length compaction from the air cavity is used to deduce the RI change within the silica cavity. We utilize fast Fourier transform (FFT) algorithm and two bandpass filters for the signal extraction of each cavity. Inclusion of such a simple cascaded FPI structure will enable accurate determination of physical parameters under the test.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Synthetic Pathway for Producing Carbon Dots for Detecting Iron Ions Using a Fiber Optic Spectrometer

Iron detection is of growing importance in the critical minerals sector, where unwanted iron ions are typically removed during the processing of target critical metals. The ideal sensor should utilize inexpensive, scalable materials along with a low-cost, robust, and easy-to-use analysis platform. Here, we demonstrate a simple acid–base synthesis of luminescent iron-responsive carbon dots by reacting ethanolamine, phosphoric acid, and m-phenylenediamine. The carbon dots exhibit selective, iron-specific emission quenching, with the ability to detect part-per-billion levels of iron ions even in 0.1 M HCl. After benchmarking the purified materials using a commercial spectrometer, a “low-cost” process is demonstrated in which carbon dots with minimal purification are coupled with a portable fiber-optic spectrometer for analyzing iron content. Carbon dot-coated paper strips are also evaluated as another convenient platform for iron analysis. Taken together, the sensing material and platforms demonstrated here are well-suited for detecting trace quantities of iron in environmentally relevant conditions, with potential applications in tracking iron removal processes during critical mineral production as one exciting area of interest.

acid mine draining↗