Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “failure reports”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Enhancing fatigue life by ductile-transformable multicomponent B2 precipitates in a high-entropy alloy

Catastrophic accidents caused by fatigue failures often occur in engineering structures. Thus, a fundamental understanding of cyclic-deformation and fatigue-failure mechanisms is critical for the development of fatigue-resistant structural materials. Here we report a high-entropy alloy with enhanced fatigue life by ductile-transformable multicomponent B2 precipitates. Its cyclic-deformation mechanisms are revealed by real-time in-situ neutron diffraction, transmission-electron microscopy, crystal-plasticity modeling, and Monte-Carlo simulations. Multiple cyclic-deformation mechanisms, including dislocation slips, precipitation strengthening, deformation twinning, and reversible martensitic phase transformation, are observed in the studied high-entropy alloy. Its improved fatigue performance at low strain amplitudes, i.e., the high fatigue-crack-initiation resistance, is attributed to the high elasticity, plastic deformability, and martensitic transformation of the B2-strengthening phase. This study shows that fatigue-resistant alloys can be developed by incorporating strengthening ductile-transformable multicomponent intermetallic phases.

36 MATERIALS SCIENCE↗

Interdiffusion Behavior of Al-Rich Oxidation Resistant Coatings on Ferritic-Martensitic Alloys

We investigated interdiffusion of thin Al-rich coatings synthesized by chemical vapor deposition (CVD) and pack cementation on 9Cr ferritic–martensitic alloys in the temperature range of 650–700°C. The compositional changes after long-term exposures in laboratory air and air + 10 vol% H 2 O were examined experimentally. Interdiffusion was modeled by a modified coating oxidation and substrate interdiffusion model (COSIM) program. The modification enabled the program to directly input the concentration profiles of the as-deposited coating determined by electron probe microanalysis (EPMA). Reasonable agreement was achieved between the simulated and experimental Al profiles after exposures. Moreover, the model was also applied to predict coating lifetime at 650–700°C based on a minimum Al content (Cb) required at the coating surface to re-form protective oxide scale. In addition to a C b value established from the failure of a thin CVD coating at 700°C, values reported for slurry aluminide coatings were also included in lifetime predictions.

36 MATERIALS SCIENCE↗

Influence of Initial fabric and water-wetting on particle fracture and force chain evolution in natural silica sand

Particle fracture has a significant influence on the engineering behavior of granular materials. However, the combined influence of the initial fabric and wetting on particle fracture and force chain evolution in granular materials, particularly in sands, remains insufficiently explored in the current literature. Here, in this paper, one-dimensional (1D) confined compression experiments were conducted on dry and wet specimens, and particle-level fracture was captured using three-dimensional (3D) in-situ Synchrotron Micro-Computed Tomography (SMT). A quantitative assessment of particle fracture revealed that wet specimens, which have disturbed fabric, exhibited a higher fracture percentage in comparison to dry specimens. Complementary 3D finite element (FE) simulations were performed using dry and wet (only solid fabric was considered and the influence of pore water is not considered) sand assemblies to assess interparticle contact forces and particle-scale stress distributions within the specimens. Force chain analysis was subsequently conducted, encompassing quantification of interparticle forces, characterization of force network structures, and monitoring the dynamic evolution of force chains under different strain levels. The results show that the specimens with disturbed fabric led to a more dynamic and less persistent force network, more fabric instability, and thus more reorganization of force chain structures. In addition, the frequent rearrangement of the force network in the presence of water (with reduced inter-particle contact friction) likely exacerbates localized stress concentrations, promoting failure in previously unengaged or weakly connected particles. The results reported in this paper offer a new insight into how the initial fabric and wetting cause different fracture behavior. The findings can also pave the way for more in-depth future investigations into the mechanics governing particle fracture in granular assemblies.

Finite element analysis↗

Stereotactic Body Radiotherapy for Lesions of the Spine and Paraspinal Regions

Purpose: To describe our experience and clinical strategy for stereotactic body radiotherapy (SBRT) of spinal lesions. Methods and Materials: Thirty-two patients with 33 spinal lesions underwent computed tomography-based simulation while free breathing. Gross/clinical target volumes included involved portions of the vertebral body and paravertebral/epidural tumor. Planning target volume (PTV) expansion was 6 mm axially and 3 mm radially; the cord was excluded from the PTV. Biologic equivalent dose was calculated using the linear quadratic model with {alpha}/{beta} = 3 Gy. Treatment was linear accelerator based with on-board imaging; dose was adjusted to maintain cord dose within tolerance. Survival, local control, pain, and neurologic status were monitored. Results: Twenty-one patients are alive at 1 year (median survival, 14 months). Median follow-up is 6 months for all patients (7 months for survivors). Mean previous radiotherapy dose to 22 patients was 35 Gy, and median interval was 17 months. Renal (31%), breast, and lung (19% each) were the most common histologic sites. Three SBRT fractions (range, one to four fractions) of 7 Gy (range, 5-16 Gy) were delivered. Median cord and target biologic equivalent doses were 70 Gy{sub 3} and 34.3 Gy{sub 10}, respectively. Thirteen patients reported complete and 17 patients reported partial pain relief at 1 month. There were four failures (mean, 5.8 months) with magnetic resonance imaging evidence of in-field progression. No dosimetric parameters predictive of failure were identified. No treatment-related toxicity was seen. Conclusions: Spinal SBRT is effective in the palliative/re-treatment setting. Volume expansion must ensure optimal PTV coverage while avoiding spinal cord toxicity. The long-term safety of spinal SBRT and the applicability of the linear-quadratic model in this setting remain to be determined, particularly the time-adjusted impact of prior radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

RTOG 0417: Efficacy of Bevacizumab in Combination With Definitive Radiation Therapy and Cisplatin Chemotherapy in Untreated Patients With Locally Advanced Cervical Carcinoma

Purpose: Radiation Therapy Oncology Group 0417 was a phase II study that explored the safety and efficacy of the addition of bevacizumab to chemoradiation therapy. The safety results have been previously reported. Herein we report the secondary efficacy endpoints of overall survival (OS), locoregional failure (LRF), para-aortic nodal failure (PAF), distant failure (DF), and disease-free survival (DFS). Methods and Materials: Eligible patients with bulky Stage IB-IIIB disease were treated with once-weekly cisplatin (40 mg/m{sup 2}) chemotherapy and standard pelvic radiation therapy and brachytherapy. Bevacizumab was administered at 10 mg/kg intravenously every 2 weeks for 3 cycles during chemoradiation. For OS, failure was defined as death of any cause and was measured from study entry to date of death. LRF was defined as any failure in the pelvis. PAF was defined as any para-aortic nodal failure. DF was analyzed both including and excluding PAF. DFS was measured from study entry to date of first LRF. DF was measured with or without PAF or death. OS and DFS were estimated by the Kaplan-Meier method, and LRF and DF rates were estimated by the cumulative incidence method. Results: 49 eligible patients from 28 institutions were enrolled between 2006 and 2009. The median follow-up time was 3.8 years (range, 0.8-6.0 years). The surviving patients had a median follow-up time of 3.9 years (range, 2.1-6.0 years). Most patients had tumors of International Federation of Gynecology and Obstetrics Stage IIB (63%), and 80% were squamous. The 3-year OS, DFS, and LRF were 81.3% (95% confidence interval [CI], 67.2%-89.8%), 68.7% (95% CI, 53.5%-79.8%), and 23.2% (95% CI, 11%-35.4%), respectively. The PAF, DF without PAF, and DF with PAF at 3 years were 8.4% (95% CI, 0.4%-16.3%), 14.7% (95% CI, 4.5%-24.9%), and 23.1% (95% CI 11.0%-35.2%), respectively. Conclusion: In this study, bevacizumab in combination with standard pelvic chemoradiation therapy for locally advanced cervical cancer showed efficacy results that are promising and may warrant further investigation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

IMPROVING THE ACCURACY OF COMPOSITE METHODS: A G4MP2 METHOD WITH G4-LIKE ACCURACY AND IMPLICATIONS FOR MACHINE LEARNING

G4MP2 theory has proven to be a reliable and accurate quantum chemical composite method for the calculation of molecular energies using an approximation based on second-order perturbation theory to lower computational costs compared to G4 theory. However, it has been found to have significantly increased errors when applied to larger organic molecules with 10 or more nonhydrogen atoms. We report here on an investigation of the cause of the failure of G4MP2 theory for such larger molecules. One source of error is found to be the "higher-level correction (HLC)", which is meant to correct for deficiencies in correlation contributions to the calculated energies. This is because the HLC assumes that the contribution is independent of the element and the type of bonding involved, both of which become more important with larger molecules. We address this problem by adding an atom-specific correction, dependent on atom type but not bond type, to the higher-level correction. We find that a G4MP2 method that incorporates this modification of the higher-level correction, referred to as G4MP2A, becomes as accurate as G4 theory (for computing enthalpies of formation) for a test set of molecules with less than 10 nonhydrogen atoms as well as a set with 10-14 such atoms, the set of molecules considered here, with a much lower computational cost. The G4MP2A method is also found to significantly improve ionization potentials and electron affinities. Finally, we implemented the G4MP2A energies in a machine learning method to predict molecular energies.

Dandu, Naveen↗

Reliable LED Lighting Technologies: Key Factors and Procurement Guidance

Abstract— Lighting systems have the ability to transform the economic and educational infrastructure of disadvantaged communities, and eradicating “light poverty” has become one of the primary goals of the International Year of Light 2015. Solid-state lighting (SSL) technology, based on light-emitting diode (LED) light sources, has emerged as the next generation of lighting technology, with a current global market penetration of roughly 5%. This paper will report on recent research on understanding SSL lighting system reliability (failure modes, environmental stressors, electrical power quality); discuss the implications of SSL technology reliability for providing lighting services; and suggest practical approaches to ensure SSL reliability to benefit humanity. Among the key findings from this work is that LED sources can be extremely reliable, withstanding a broad range of environmental stresses without failure. Nonetheless, SSL lighting systems can have a negative impact on electrical power reliability, as well as on the affordability of lighting services, without attention to the quality of the accompanying power infrastructure. It is therefore critical to ensure that the performance of the power supply electronics used in lighting systems is matched to the quality of the power source, when evaluating energy efficient lighting choices.

Davis, Lynn↗

What Caused the Lead burn-out in Spectrometer Magnet 2B

The spectrometer solenoids are supposed to be the first magnets installed in the MICE Cooling Channel. The results of the test of Spectrometer Magnet 2B are reported in a previous MICE Note. Magnet 2B was tested with all five coils connected in series. The magnet failed because a lead to coil M2 failed before it could be trained to its full design current of 275 A. First, this report describes the condition of the magnet when the lead failure occurred. The lead that failed was between the cold mass feed-through and the heavy lead that connected to coil M2 and the quench protection diodes. It is believed that the lead failed because the minimum propagation zone (MPZ) length was too short. The quench was probably triggered by lead motion in the field external to the magnet center coil. The effect of heat transfer on quench propagation and MPZ length is discussed. The MPZ length is compared for a number of cases that apply to the spectrometer solenoid 2B as built and as it has been repaired. The required heat transfer coefficient for cryogenic stability and the quench propagation velocity along the leads are compared for various parts of the Magnet leads inside the cold mass cryostat. The effect of the insulation on leads on heat transfer is and stability is discussed.

42 ENGINEERING↗

Update on Common-Cause Failure Experience and Mitigation Practices

Experience in other industries has shown that digital technology can provide substantial benefits in terms of performance and reliability. However, the U.S. nuclear power industry has been slow to adopt the technology extensively in its instrumentation and control (I&C) applications because of inhibiting factors such as regulatory uncertainty, insufficient technological experience base, implementation complexity, limited availability of nuclear-qualified products and vendors, and inadequate definition of modernization cost recapture. Although there have been examples of digital technology usage in the nuclear power industry, challenges to the qualification of digital technology for high-integrity nuclear power plant (NPP) applications have severely constrained more widespread progress in achieving the benefits that are possible through the transition to digital. The U.S. Department of Energy (DOE) Office of Nuclear Energy (NE) established the Advanced Sensors and Instrumentation (ASI) technology area under the Nuclear Energy Enabling Technologies (NEET) Program to coordinate the instrumentation and controls (I&C) research across DOE NE and to identify and lead efforts to address common needs. As part of the NEET ASI research program, the Digital Technology Qualification project was established. Under this project, the Oak Ridge National Laboratory (ORNL) is leading the investigation into mitigation of digital common-cause failure (CCF) vulnerabilities for nuclear-qualified applications. This technical report documents updated and expanded findings from research activities by ORNL. Specifically, the report describes CCF experience in the nuclear and nonnuclear industries, identifies the state of the practice for CCF mitigation through key examples, and presents conclusions from the determination of knowledge gaps.

Wood, Richard Thomas↗

CCF Parameter Estimations, 2020 Update

This report documents the quantitative results of the common-cause failure (CCF) data collection effort (which included data through 2020) and summarizes the results of the parameter estimation quantification process performed on CCF data in the U.S. Nuclear Regulatory Commission (NRC) CCF database. This is the 2020 update to NUREG/CR-5497, updating data and parameter estimations for CCFs. This release, CCF Parameter Estimation 2020, reflects the CCF data contained within the CCF database, https://rads.inl.gov/Pages/CCF.aspx, by executing (in August 2021) the CCF query rules in the folder SPAR Rules 2020. The data covers the period from 1/1/2006 to 12/31/2020, the most recent 15-year period in which data are available. The use of the most recent rolling 15-year data in parameter estimation differs from previous updates, in which 1/1/1997 was used as the starting date (e.g., 1/1/1997 to 12/31/2015 for the 2015 update, 1/1/1997 to 12/31/2012 for the 2012 update). The new date range (i.e., the most recent 15-year period), was selected for this CCF update so as to be consistent with the date range chosen for the component reliability parameter estimation, and with the effort to include sufficient data for analysis while simultaneously reflecting the most recent industry performance. These results are appropriate for use in probabilistic risk assessment (PRA) studies, including the Standardized Plant Analysis Risk (SPAR) models of commercial nuclear power plants (NPPs) in the U.S. This update may be referred as: U.S. Nuclear Regulatory Commission, "CCF Parameter Estimations, 2020 Update," https://nrcoe.inl.gov/publicdocs/CCF/ccfparamest2020.pdf, November 2021.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Experiment D012: Astronaut maneuvering unit

All astronaut maneuvering unit systems used during the Gemini 9 mission were in an acceptable condition for flight when the evaluation was terminated. Some difficulty was experienced with reception of the voice signal by the command pilot. All of the donning provisions are apparently practical in the orbital environment; however, the donning activities were more difficult to perform than had been experienced in the one-g and zero-g training exercises. Lighting was marginal because of the failure of one adapter floodlight and one penlight. The crewmembers reported a tendency for the extravehicular activity pilot and any loose equipment to move outward from the earth relative to the spacecraft. This tendency affected activities at a work station and maneuvering in an extravehicular environment.

Vanschaik, P. N.↗

The interstellar medium in the line of sight to X Persei and 3U 0352+30

The X-ray absorption column of 3U 0352+30 obtained with the Copernicus X-ray telescopes is compared with the atomic and molecular hydrogen column densities in the line of sight to X Per, as measured with the Copernicus ultraviolet telescopes, and with the visible reddening of X Per, by means of reddening/X-ray absorption-column relationships. The results are consistent with both the star and X-ray source being equidistant. When comparing X-ray absorbing column densities with those derived by other means, it is necessary to include the effects of molecular hydrogen in the line of sight to X Per and, in particular, the related number of medium-weight elements. It is suggested that failure to do this in previous work may account for reported discrepancies between the X-ray and radio column densities to the Crab Nebula and other sources. The far-ultraviolet extinction curve of X Per is presented.

Mason, K. O.↗

An experiment in software reliability

The results of a software reliability experiment conducted in a controlled laboratory setting are reported. The experiment was undertaken to gather data on software failures and is one in a series of experiments being pursued by the Fault Tolerant Systems Branch of NASA Langley Research Center to find a means of credibly performing reliability evaluations of flight control software. The experiment tests a small sample of implementations of radar tracking software having ultra-reliability requirements and uses n-version programming for error detection, and repetitive run modeling for failure and fault rate estimation. The experiment results agree with those of Nagel and Skrivan in that the program error rates suggest an approximate log-linear pattern and the individual faults occurred with significantly different error rates. Additional analysis of the experimental data raises new questions concerning the phenomenon of interacting faults. This phenomenon may provide one explanation for software reliability decay.

Dunham, J. R.↗

Reliability issues in active control of large flexible space structures

Efforts in this reporting period were centered on four research tasks: design of failure detection filters for robust performance in the presence of modeling errors, design of generalized parity relations for robust performance in the presence of modeling errors, design of failure sensitive observers using the geometric system theory of Wonham, and computational techniques for evaluation of the performance of control systems with fault tolerance and redundancy management

Vandervelde, W. E.↗

Expert System for UNIX System Reliability and Availability Enhancement

Highly reliable and available systems are critical to the airline industry. However, most off-the-shelf computer operating systems and hardware do not have built-in fault tolerant mechanisms, the UNIX workstation is one example. In this research effort, we have developed a rule-based Expert System (ES) to monitor, command, and control a UNIX workstation system with hot-standby redundancy. The ES on each workstation acts as an on-line system administrator to diagnose, report, correct, and prevent certain types of hardware and software failures. If a primary station is approaching failure, the ES coordinates the switch-over to a hot-standby secondary workstation. The goal is to discover and solve certain fatal problems early enough to prevent complete system failure from occurring and therefore to enhance system reliability and availability. Test results show that the ES can diagnose all targeted faulty scenarios and take desired actions in a consistent manner regardless of the sequence of the faults. The ES can perform designated system administration tasks about ten times faster than an experienced human operator. Compared with a single workstation system, our hot-standby redundancy system downtime is predicted to be reduced by more than 50 percent by using the ES to command and control the system.

Xu, Catherine Q.↗

Novel composites for wing and fuselage applications

Probabilistic predictions based on the IPACS code are presented for the material and structural response of unnotched and notched, IM6/3501-6 Gr/Ep laminates. Comparisons of predicted and measured modulus and strength distributions are given for unnotched unidirectional, cross-ply and quasi-isotropic laminates. The predicted modulus distributions were found to correlate well with the test results for all three unnotched laminates. Correlations of strength distributions for the unnotched laminates are judged good for the unidirectional laminate and fair for the cross-ply laminate, whereas the strength correlation for the quasi-isotropic laminate is judged poor because IPACS did not have a progressive failure capability at the time this work was performed. The report also presents probabilistic and structural reliability analysis predictions for the strain concentration factor (SCF) for an open-hole, quasi-isotropic laminate subjected to longitudinal tension. A special procedure was developed to adapt IPACS for the structural reliability analysis. The reliability results show the importance of identifying the most significant random variables upon which the SCF depends, and of having accurate scatter values for these variables.

Sobel, L. H.↗

Shuttle Ground Support Equipment (GSE) T-0 Umbilical to Space Shuttle Program (SSP) Flight Elements Consultation

The NASA Engineering and Safety Center (NESC) was tasked with assessing the validity of an alternate opinion that surfaced during the investigation of recurrent failures at the Space Shuttle T-0 umbilical interface. The most visible problem occurred during the Space Transportation System (STS)-112 launch when pyrotechnics used to separate Solid Rocket Booster (SRB) Hold-Down Post (HDP) frangible nuts failed to fire. Subsequent investigations recommended several improvements to the Ground Support Equipment (GSE) and processing changes were implemented, including replacement of ground-half cables and connectors between flights, along with wiring modifications to make critical circuits quad-redundant across the interface. The alternate opinions maintained that insufficient data existed to exonerate the design, that additional data needed to be gathered under launch conditions, and that the interface should be further modified to ensure additional margin existed to preclude failure. The results of the assessment are contained in this report.

Wilson, Timmy R.↗