Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “error localization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Evaluation of Matrix9 silicon photomultiplier array for small-animal PET

Purpose: The MatrixSL-9-30035-OEM (Matrix9) from SensL is a large-area silicon photomultiplier (SiPM) photodetector module consisting of a 3 × 3 array of 4 × 4 element SiPM arrays (total of 144 SiPM pixels) and incorporates SensL’s front-end electronics board and coincidence board. Each SiPM pixel measures 3.16 × 3.16 mm{sup 2} and the total size of the detector head is 47.8 × 46.3 mm{sup 2}. Using 8 × 8 polished LSO/LYSO arrays (pitch 1.5 mm) the performance of this detector system (SiPM array and readout electronics) was evaluated with a view for its eventual use in small-animal positron emission tomography (PET). Methods: Measurements of noise, signal, signal-to-noise ratio, energy resolution, flood histogram quality, timing resolution, and array trigger error were obtained at different bias voltages (28.0–32.5 V in 0.5 V intervals) and at different temperatures (5 °C–25 °C in 5 °C degree steps) to find the optimal operating conditions. Results: The best measured signal-to-noise ratio and flood histogram quality for 511 keV gamma photons were obtained at a bias voltage of 30.0 V and a temperature of 5 °C. The energy resolution and timing resolution under these conditions were 14.2% ± 0.1% and 4.2 ± 0.1 ns, respectively. The flood histograms show that all the crystals in the 1.5 mm pitch LSO array can be clearly identified and that smaller crystal pitches can also be resolved. Flood histogram quality was also calculated using different center of gravity based positioning algorithms. Improved and more robust results were achieved using the local 9 pixels for positioning along with an energy offset calibration. To evaluate the front-end detector readout, and multiplexing efficiency, an array trigger error metric is introduced and measured at different lower energy thresholds. Using a lower energy threshold greater than 150 keV effectively eliminates any mispositioning between SiPM arrays. Conclusions: In summary, the Matrix9 detector system can resolve high-resolution scintillator arrays common in small-animal PET with adequate energy resolution and timing resolution over a large detector area. The modular design of the Matrix9 detector allows it to be used as a building block for simple, low channel-count, yet high performance, small animal PET or PET/MRI systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Strict Convexity of the Free Energy of the Canonical Ensemble Under Decay of Correlations

We consider a one-dimensional lattice system of unbounded, real-valued spins. We allow arbitrary strong, attractive, nearest-neighbor interaction. We show that the free energy of the canonical ensemble (ce) converges uniformly in C{sup 2} to the free energy of the grand ce (gce). The error estimates are quantitative. A direct consequence is that the free energy of the ce is uniformly strictly convex for large systems. Another consequence is a quantitative local Cramér theorem which yields the strict convexity of the coarse-grained Hamiltonian. With small adaptations, the argument could be generalized to systems with finite-range interaction on a graph, as long as the degree of the graph is uniformly bounded and the associated gce has uniform decay of correlations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

End-to-end test of spatial accuracy in Gamma Knife treatments for trigeminal neuralgia

Purpose: Spatial accuracy is most crucial when small targets like the trigeminal nerve are treated. Although current quality assurance procedures typically verify that individual apparatus, like the MRI scanner, CT scanner, Gamma Knife, etc., are meeting specifications, the cumulative error of all equipment and procedures combined may exceed safe margins. This study uses an end-to-end approach to assess the overall targeting errors that may have occurred in individual patients previously treated for trigeminal neuralgia. Methods: The trigeminal nerve is simulated by a 3 mm long, 3.175 mm (1/8 in.) diameter MRI-contrast filled cavity embedded within a PMMA plastic capsule. The capsule is positioned within the head frame such that the location of the cavity matches the Gamma Knife coordinates of an arbitrarily chosen, previously treated patient. Gafchromic EBT2 film is placed at the center of the cavity in coronal and sagittal orientations. The films are marked with a pinprick to identify the cavity center. Treatments are planned for radiation delivery with 4 mm collimators according to MRI and CT scans using the clinical localizer boxes and acquisition protocols. Shots are planned so that the 50% isodose surface encompasses the cavity. Following irradiation, the films are scanned and analyzed. Targeting errors are defined as the distance between the pinprick, which represents the intended target, and the centroid of the 50% isodose line, which is the center of the radiation field that was actually delivered. Results: Averaged over ten patient simulations, targeting errors along the x, y, and z coordinates (patient’s left-to-right, posterior-to-anterior, and head-to-foot) were, respectively, −0.060 ± 0.363, −0.350 ± 0.253, and 0.348 ± 0.204 mm when MRI was used for treatment planning. Planning according to CT exhibited generally smaller errors, namely, 0.109 ± 0.167, −0.191 ± 0.144, and 0.211 ± 0.094 mm. The largest errors along individual axes in MRI- and CT-planned treatments were, respectively, −0.761 mm in the y-direction and 0.428 mm in the x-direction, well within safe limits. Conclusions: The highly accurate dose delivery was possible because the Gamma Knife, MRI scanner, and other equipment performed within tight limits and scans were acquired using the thinnest slices and smallest pixel sizes available. Had the individual devices performed only near the limits of their specifications, the cumulative error could have left parts of the trigeminal nerve undertreated. The presented end-to-end test gives assurance that patients had received the expected high quality treatment. End-to-end tests should become part of clinical practice.

60 APPLIED LIFE SCIENCES↗

Dosimetric Impact of Intrafractional Patient Motion in Pediatric Brain Tumor Patients

The purpose of this study was to determine the dosimetric consequences of intrafractional patient motion on the clinical target volume (CTV), spinal cord, and optic nerves for non-sedated pediatric brain tumor patients. The patients were immobilized for treatment using a customized thermoplastic full-face mask and bite-block attached to an array of reflectors. The array was optically tracked by infra-red cameras at a frequency of 10 Hz. Patients were localized based on skin/mask marks and weekly films were taken to ensure proper setup. Before each noncoplanar field was delivered, the deviation from baseline of the array was recorded. The systematic error (SE) and random error (RE) were calculated. Direct simulation of the intrafractional motion was used to quantify the dosimetric changes to the targets and critical structures. Nine patients utilizing the optical tracking system were evaluated. The patient cohort had a mean of 31 {+-} 1.5 treatment fractions; motion data were acquired for a mean of 26 {+-} 6.2 fractions. The mean age was 15.6 {+-} 4.1 years. The SE and RE were 0.4 and 1.1 mm in the posterior-anterior, 0.5 and 1.0 mm in left-right, and 0.6 and 1.3 mm in superior-inferior directions, respectively. The dosimetric effects of the motion on the CTV were negligible; however, the dose to the critical structures was increased. Patient motion during treatment does affect the dose to critical structures, therefore, planning risk volumes are needed to properly assess the dose to normal tissues. Because the motion did not affect the dose to the CTV, the 3-mm PTV margin used is sufficient to account for intrafractional motion, given the patient is properly localized at the start of treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Machine learning of molecular properties: Locality and active learning

In recent years, the machine learning techniques have shown great potent1ial in various problems from a multitude of disciplines, including materials design and drug discovery. The high computational speed on the one hand and the accuracy comparable to that of density functional theory on another hand make machine learning algorithms efficient for high-throughput screening through chemical and configurational space. However, the machine learning algorithms available in the literature require large training datasets to reach the chemical accuracy and also show large errors for the so-called outliers—the out-of-sample molecules, not well-represented in the training set. In the present paper, we propose a new machine learning algorithm for predicting molecular properties that addresses these two issues: it is based on a local model of interatomic interactions providing high accuracy when trained on relatively small training sets and an active learning algorithm of optimally choosing the training set that significantly reduces the errors for the outliers. We compare our model to the other state-of-the-art algorithms from the literature on the widely used benchmark tests.

Gubaev, Konstantin (ORCID:0000000326128515)↗

Multivariate analysis of gamma spectra to characterize used nuclear fuel

Abstract—The Multi-Isotope Process (MIP) Monitor provides an efficient approach to monitoring the process conditions in used nuclear fuel reprocessing facilities to support process verification and validation. The MIP Monitor applies multivariate analysis to gamma spectroscopy of reprocessing streams in order to detect small changes in the gamma spectrum, which may indicate changes in process conditions. This research extends the MIP Monitor by characterizing a used fuel sample after initial dissolution according to the type of reactor of origin (pressurized or boiling water reactor), initial enrichment, burn up, and cooling time. Simulated gamma spectra were used to develop and test three fuel characterization algorithms. The classification and estimation models employed are based on the partial least squares regression (PLS) algorithm. A PLS discriminate analysis model was developed which perfectly classified reactor type. Locally weighted PLS models were fitted on-the-fly to estimate continuous fuel characteristics. Burn up was predicted within 0.1% root mean squared percent error (RMSPE) and both cooling time and initial enrichment within approximately 2% RMSPE. This automated fuel characterization can be used to independently verify operator declarations of used fuel characteristics and inform the MIP Monitor anomaly detection routines at later stages of the fuel reprocessing stream to improve sensitivity to changes in operational parameters and material diversions.

Multivariate Analysis for Characterization of Used↗

Low-complexity atlas-based prostate segmentation by combining global, regional, and local metrics

Purpose: To improve the efficiency of atlas-based segmentation without compromising accuracy, and to demonstrate the validity of the proposed method on MRI-based prostate segmentation application. Methods: Accurate and efficient automatic structure segmentation is an important task in medical image processing. Atlas-based methods, as the state-of-the-art, provide good segmentation at the cost of a large number of computationally intensive nonrigid registrations, for anatomical sites/structures that are subject to deformation. In this study, the authors propose to utilize a combination of global, regional, and local metrics to improve the accuracy yet significantly reduce the number of required nonrigid registrations. The authors first perform an affine registration to minimize the global mean squared error (gMSE) to coarsely align each atlas image to the target. Subsequently, atarget-specific regional MSE (rMSE), demonstrated to be a good surrogate for dice similarity coefficient (DSC), is used to select a relevant subset from the training atlas. Only within this subset are nonrigid registrations performed between the training images and the target image, to minimize a weighted combination of gMSE and rMSE. Finally, structure labels are propagated from the selected training samples to the target via the estimated deformation fields, and label fusion is performed based on a weighted combination of rMSE and local MSE (lMSE) discrepancy, with proper total-variation-based spatial regularization. Results: The proposed method was applied to a public database of 30 prostate MR images with expert-segmented structures. The authors’ method, utilizing only eight nonrigid registrations, achieved a performance with a median/mean DSC of over 0.87/0.86, outperforming the state-of-the-art full-fledged atlas-based segmentation approach of which the median/mean DSC was 0.84/0.82 when applying to their data set. Conclusions: The proposed method requires a fixed number of nonrigid registrations, independent of atlas size, providing desirable scalability especially important for a large or growing atlas. When applied to prostate segmentation, the method achieved better performance to the state-of-the-art atlas-based approaches, with significant improvement in computation efficiency. The proposed rationale of utilizing jointly global, regional, and local metrics, based on the information characteristic and surrogate behavior for registration and fusion subtasks, can be extended naturally to similarity metrics beyond MSE, such as correlation or mutual information types.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimization-based, property-preserving algorithm for passive tracer transport

Here we present a new optimization-based property-preserving algorithm for passive tracer transport. The algorithm utilizes a semi-Lagrangian approach based on incremental remapping of the mass and the total tracer. However, unlike traditional semi-Lagrangian schemes, which remap the density and the tracer mixing ratio through monotone reconstruction or flux correction, we utilize an optimization-based remapping that enforces conservation and local bounds as optimization constraints. In so doing we separate accuracy considerations from preservation of physical properties to obtain a conservative, second-order accurate transport scheme that also has a notion of optimality. Moreover, we prove that the optimization-based algorithm preserves linear relationships between tracer mixing ratios. We illustrate the properties of the new algorithm using a series of standard tracer transport test problems in a plane and on a sphere.

97 MATHEMATICS AND COMPUTING↗

A Two-Level Model Predictive Control-Based Approach for Building Energy Management including Photovoltaics, Energy Storage, Solar Forecasting and Building Loads

This paper uses a two-level model predictive control-based approach for the coordinated control and energy management of an integrated system that includes photovoltaic (PV) generation, energy storage, and building loads. Novel features of the proposed local controller include (1) the ability to simultaneously manage building loads and energy storage to achieve different operational objectives such as energy efficiency, economic cost efficiency, demand response and grid optimization through the design of specific power trajectory tracking performance functionals, (2) an energy trim function that minimizes the impact of solar forecasting errors on system performance, and (3) the design of a state of charge controller that uses day-ahead forecast of solar power and building loads to intialize energy storage at the start of each day. The local controller is tested in simulation using an exemplary system with PV generation, energy storage and dispatchable building loads. Two sample days with different PV forecasts and multiple case scenarios are considered, and the performance of the algorithm in managing the real and reactive net building load trajectories and the ramp rate of PV injections into the utility network are evaluated. The simulations are based on actual forecasted and measured PV data, and the results show that the local controller meets the tracking requirements for real and reactive power within the operating constraints of the building.

14 SOLAR ENERGY↗

Tripartite entanglement in qudit stabilizer states and application in quantum error correction

Consider a stabilizer state on n qudits, each of dimension D with D being a prime or squarefree integer, divided into three mutually disjoint sets or parts. Generalizing a result of Bravyi et al.[J. Math. Phys. 47, 062106 (2006)] for qubits (D=2), we show that up to local unitaries, the three parts of the state can be written as tensor product of unentangled signle-qudit states, maximally entangled Einstein-Podolsky-Rosen (EPR) pairs, and tripartite Greenberger-Horne-Zeilinger (GHZ) states. We employ this result to obtain a complete characterization of the properties of a class of channels associated with stabilizer error-correcting codes, along with their complementary channels.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantitative assessment of eddy viscosity rans models for turbulent mixed convection in a differentially heated plane channel

Turbulent mixed convection between two vertical, infinite parallel plates at different temperatures is studied using various two-equation turbulence models. The numerical simulations are performed at a turbulent Reynolds number of Re τ = 150 and a Grashof number of Gr = 9.6 × 10 5 . Comparisons are made against the highly trusted DNS results. Consistent with the DNS approach, the current simulations are performed using constant properties and the Boussinesq approximation to predict the influence of buoyancy. Previous studies have provided assessments of two-equation turbulence models for various scenarios, but often rely on a qualitative “eye” test in order to determine the most appropriate model to predict a given flow. This study aims to provide a new form of quantitative assessment that accounts for both the physics captured by the turbulence model as well as the magnitude of the system response quantities (SRQ) using a modified symmetric mean absolute percent error (SMAPE) method. This method is designed to be approachable to researchers at any level and can be applied to system response quantities from multiple research fields. Uncertainty quantification is also performed to determine the discretization error for each turbulence model. Recommendations are made as to which turbulence models best capture the physics – hydrodynamically and thermally – using both local and global validation metrics. Lastly, a sensitivity analysis is performed on the damping functions used in the most accurate models. This underpins the potential of model developments and adjustments most worth pursuing for buoyant flows. Finally, this framework provides a more physics-based comparative analysis of the selected turbulence models.

42 ENGINEERING↗

Stochastic modeling of evaporating sprays within a consistent hybrid joint PDF framework

In the present study, a framework for modeling two-phase evaporating flow is presented, which employs an Eulerian-Lagrangian-Lagrangian approach. For the continuous phase, a joint velocity-composition probability density function (PDF) method is used. Opposed to other approaches, such PDF methods require no modeling for turbulent convection and chemical source terms. For the dispersed phase, the PDF of velocity, diameter, temperature, seen gas velocity and seen gas composition is calculated. This provides a unified formulation, which allows to consistently address the different modeling issues associated with such a system. Because of the high dimensionality, particle methods are employed to solve the PDF transport equations. To further enhance computational efficiency, a local particle time-stepping algorithm is implemented and a particle time-averaging technique is employed to reduce statistical and bias errors. In comparison to previous studies, a significantly smaller number of droplet particles per grid cell can be employed for the computations, which rely on two-way coupling between the droplet and gas phases. The framework was validated using established experimental data and a good overall agreement can be observed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Eulerian finite element simulations of the drop weight impact test with a dislocation Density-based continuum model

During a drop weight impact test, the kinetic energy of the falling weight is transferred into the sample resting on the anvil. The plastic deformation in the sample is an important mechanism for the dissipation of the input kinetic energy. We use Eulerian finite element analysis to simulate the deformation and temperature evolution in a 1,3,5-trinitro-1,3,5-triazine (RDX) sample consisting of multiple crystals. In Eulerian finite element simulations, the mesh moves relative to the material. After every change of position between the mesh and the material, the state variables are interpolated to the new mesh position, i.e., advection. In an effort to reduce the advection errors, we use a rate form of a dislocation density-based continuum model by Luscher et al. Here, the simulations predict localization of plastic deformation, and plastic dissipation as a significant source of heat generation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Exploring and enhancing the accuracy of interior-scaled Perdew–Zunger self-interaction correction

The Perdew–Zunger self-interaction correction (PZ-SIC) improves the performance of density functional approximations for the properties that involve significant self-interaction error (SIE), as in stretched bond situations, but overcorrects for equilibrium properties where SIE is insignificant. This overcorrection is often reduced by local scaling self-interaction correction (LSIC) of the PZ-SIC to the local spin density approximation (LSDA). Here, we propose a new scaling factor to use in an LSIC-like approach that satisfies an additional important constraint: the correct coefficient of the atomic number Z in the asymptotic expansion of the exchange–correlation (xc) energy for atoms. LSIC and LSIC+ are scaled by functions of the iso-orbital indicator z σ , which distinguishes one-electron regions from many-electron regions. LSIC+ applied to the LSDA works better for many equilibrium properties than LSDA-LSIC and the Perdew, Burke, and Ernzerhof generalized gradient approximation (GGA), and almost close to the strongly constrained and appropriately normed (SCAN) meta-GGA. LSDA-LSIC and LSDA-LSIC+, however, fail to predict interaction energies involving weaker bonds, in sharp contrast to their earlier successes. It is found that more than one set of localized SIC orbitals can yield a nearly degenerate energetic description of the same multiple covalent bond, suggesting that a consistent chemical interpretation of the localized orbitals requires a new way to choose their Fermi orbital descriptors. To make a locally scaled down SIC to functionals beyond the LSDA requires a gauge transformation of the functional’s energy density. Here, the resulting SCAN-sdSIC, evaluated on SCAN-SIC total and localized orbital densities, leads to an acceptable description of many equilibrium properties including the dissociation energies of weak bonds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Understanding the chemical bonding of ground and excited states of HfO and HfB with correlated wavefunction theory and density functional approximations

Knowledge of the chemical bonding of HfO and HfB ground and low-lying electronic states provides essential insights into a range of catalysts and materials that contain Hf–O or Hf–B moieties. Here, we carry out high-level multi-reference configuration interaction theory and coupled cluster quantum chemical calculations on these systems. We compute full potential energy curves, excitation energies, ionization energies, electronic configurations, and spectroscopic parameters with large quadruple-ζ and quintuple-ζ quality correlation consistent basis sets. We also investigate equilibrium chemical bonding patterns and effects of correlating core electrons on property predictions. Differences in the ground state electron configuration of HfB(X 4 Σ - ) and HfO(X 1 Σ + ) lead to a significantly stronger bond in HfO than HfB, as judged by both dissociation energies and equilibrium bond distances. We extend our analysis to the chemical bonding patterns of the isovalent HfX (X = O, S, Se, Te, and Po) series and observe similar trends. We also note a linear trend between the decreasing value of the dissociation energy (D e ) from HfO to HfPo and the singlet–triplet energy gap (ΔE S–T ) of the molecule. Finally, we compare these benchmark results to those obtained using density functional theory (DFT) with 23 exchange–correlation functionals spanning multiple rungs of “Jacob’s ladder.” When comparing DFT errors to coupled cluster reference values on dissociation energies, excitation energies, and ionization energies of HfB and HfO, we observe semi-local generalized gradient approximations to significantly outperform more complex and high-cost functionals.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SENSITIVITY OF BLIND PULSAR SEARCHES WITH THE FERMI LARGE AREA TELESCOPE

We quantitatively establish the sensitivity to the detection of young to middle-aged, isolated, gamma-ray pulsars through blind searches of Fermi Large Area Telescope (LAT) data using a Monte Carlo simulation. We detail a sensitivity study of the time-differencing blind search code used to discover gamma-ray pulsars in the first year of observations. We simulate 10,000 pulsars across a broad parameter space and distribute them across the sky. We replicate the analysis in the Fermi LAT First Source Catalog to localize the sources, and the blind search analysis to find the pulsars. We analyze the results and discuss the effect of positional error and spin frequency on gamma-ray pulsar detections. Finally, we construct a formula to determine the sensitivity of the blind search and present a sensitivity map assuming a standard set of pulsar parameters. The results of this study can be applied to population studies and are useful in characterizing unidentified LAT sources.

79 ASTRONOMY AND ASTROPHYSICS↗

Testing Lithium-Ion Battery with the Internal Reference Electrode: An Insight into the Blocking Effect

Long-term stability of reference electrode is a major issue in lithium-ion batteries. A composite Ni-Li reference electrode (RE) with a longer lifetime than traditional Cu-wire Li reference electrodes is proposed in this study. However, the larger size of the Ni-Li RE creates a blocking effect when positioned internally in the battery. The blocking effect manifests as an abnormal feature in the measured electrode potential. A two-dimensional (2D) finite element model of the cell with an internal RE is constructed to investigate the mechanism of the blocking effect. The internal RE blocks the path of local current flow in the electrolyte, and decreases the electrochemical reaction rate of particles in the anode and cathode, leading to measurement errors. Characteristic lengths of RE and applied currents were examined as parameters in the finite element model to determine their effect on the magnitude of error. A useful guide is provided for proper selection of size of RE and applied current in dynamic tests of lithium-ion batteries.

2-D finite element model↗

A Study on Target Positioning Error and Its Impact on Dose Variation in Image-Guided Stereotactic Body Radiotherapy for the Spine

Purpose: To investigate the amount of target positioning error and evaluate its dosimetric impact during image-guided stereotactic body radiotherapy for single-fraction spine treatment. Methods and Materials: A prescription dose of 15 Gy and five to nine coplanar intensity-modulated beams were used. The patient was immobilized with a custom-fit vacuum mold, and the target was localized with a volumetric cone-beam CT image. A robotic couch with six degrees of freedom was used for target adjustment. For evaluation a cone-beam CT image was obtained at the end of treatment. Both target positioning error and its dosimetric impact were investigated for the first 9 cases. Results: For cases studied, translational errors were 0.9 {+-} 0.5 mm (lateral), 1.2 {+-} 0.9 mm (longitudinal), 0.7 {+-} 0.6 mm (vertical), and 1.8 {+-} 1.0 mm (vector), and rotational errors were 1.6 deg. {+-} 1.3 deg. (pitch), 0.8 deg. {+-} 0.9 deg. (roll), and 0.8 deg. {+-} 0.4{sup o} (yaw). For the clinical target volume, D{sub 95} (dose to 95% of target volume), D{sub 90}, D{sub max}, and D{sub mean} were evaluated. Only 1 case showed significant dose variations, reaching up to 18% in D{sub 95}. The spinal cord dose was evaluated by observing D{sub 0.1} (dose to 0.1 cm{sup 3}), D{sub 0.5}, D{sub 1.0}, and D{sub max}. Although 1 case showed a dose change reaching up to 30% in D{sub max}, cord dose was within the planning tolerance limit in all but 2 cases (3% higher in one and 0.4% higher in the other). Conclusion: The implemented image-guided stereotactic body radiotherapy provides precise target localization. However, despite reasonably precise spatial precision, dosimetric perturbation can be significant because of both extremely steep dose gradients and close distances between the target and the spinal cord.

62 RADIOLOGY AND NUCLEAR MEDICINE↗