Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “error detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Endurance Testing and Fabrication of Advanced 15-cm and 30-cm Carbon-Carbon Composite Grids

Two sets of carbon-carbon grids in a three-grid SAND configuration were endurance tested for 700 hours. Pre- and post test inspections employing electron microscope scans, x-ray fluorescence, grid mass loss measurements, and measurements of grid aperture diameters and thicknesses revealed an extraordinary low degree of erosion. No reduction in grid thicknesses was detectable within the margin of error of the measurements.

Carbon-Carbon↗

Understanding Relationships Between Satellite, Model, and Ground-Based Surface Temperature Characterizations From Overcast to Clear Conditions in Support of Satellite Remote Sensing of Clouds and Radiation

Accurate and consistent global estimates of cloud coverage and their properties are fundamental to long-term Earth radiation budget (ERB) monitoring efforts like the Clouds and the Earth’s Radiant Energy System (CERES) project. Cloud detection algorithms often apply thresholding approaches to identify where clouds occur by comparing satellite-measured radiances with those that are expected under cloud-free conditions. In addition, once a cloud is detected, the derivation of cloud optical and microphysical properties also requires knowledge of the background radiances below the cloud. In the infrared, knowledge of the surface emissivity and the expected skin temperature under both cloudy and cloud-free conditions is needed. These traits are generally well known over the oceans. Over land, however, comparisons between satellite-derived land surface temperature (LST) with that characterized in numerical weather analyses reveal large differences in many parts of the world, often exceeding 5 K, which can lead to significant satellite cloud detection and cloud property retrieval errors. Furthermore, clouds have a dramatic influence on the LST, and therefore characterization of that model parameter also depends on the capability of the model to accurately resolve clouds. Thus, the LST characterized in models is, at times, a poor approximation for what would otherwise be observed, thereby impeding accurate satellite cloud retrievals. As a result, we seek to develop a more robust method for estimating the LST required for satellite cloud characterizations. This effort is accomplished through a combination of surface emission/air temperature relationship studies in all-sky conditions using ground measurement stations, along with deep neural network (DNN) estimates of expected LST under overcast and cloud-free conditions. We demonstrate that substituting DNN-predicted LST for that generated by numerical models can mitigate model-inherent diurnal dependencies and reduce overall bias and uncertainty relative to satellite/ground observations by 0.5–4 K and 0.5–2 K, respectively. It is expected that this work will lead to improved satellite cloud retrievals that enhance ERB monitoring efforts.

B Scarino↗

Distribution power system fault control apparatus and method

A method includes detecting a fault in a grid coupled to a distribution power network, the distribution power network comprising a distribution feeder, a plurality of distributed energy resources (DERs) coupled to the distribution feeder and a reference point of applicability (RPA) associated with the plurality of DERs, and in response to detecting the fault, determining an error voltage at the RPA, converting the error voltage into an error signal, broadcasting the error signal to the plurality of DERs, and based on the error signal, reducing the error voltage at the RPA by injecting a plurality of currents from the plurality of DERs to the distribution feeder.

Cintuglu, Mehmet H.↗

In Situ Ion Counting for Improved Implanted Ion Error Rate and Silicon Vacancy Yield Uncertainty

An in situ counted ion implantation experiment improving the error on the number of ions required to form a single optically active silicon vacancy (SiV) defect in diamond 7-fold compared to timed implantation is presented. Here, traditional timed implantation relies on a beam current measurement followed by implantation with a preset pulse duration. It is dominated by Poisson statistics, resulting in large errors for low ion numbers. Instead, our in situ detection, measuring the ion number arriving at the substrate, results in a 2-fold improvement of the error on the ion number required to generate a single SiV compared to timed implantation. Through postimplantation analysis, the error is improved 7-fold compared to timed implantation. SiVs are detected by photoluminescence spectroscopy, and the yield of 2.98% is calculated through the photoluminescence count rate. Hanbury–Brown–Twiss interferometry is performed on locations potentially hosting single-photon emitters, confirming that 82% of the locations exhibit single photon emission statistics.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Rapid quantitative analysis of trace elements in plutonium alloys using a handheld laser-induced breakdown spectroscopy (LIBS) device coupled with chemometrics and machine learning

Here, we present the first reported quantification of trace elements in plutonium via a portable laser-induced breakdown spectroscopy (LIBS) device and demonstrate the use of chemometric analysis to enhance the handheld device's sensitivity and precision. Quantification of trace elements such as iron and nickel in plutonium metal via LIBS is a challenging problem due to the complex nature of the plutonium optical emission spectra. While rapid analysis of plutonium alloys has been demonstrated using portable LIBS devices, such as the SciAps Z300, their detection limits for trace elements are severely constrained by their achievable pulse power and length, light collection optics, and detectors. In this paper, analytical methods are evaluated as a means to circumvent the detection constraints. Three chemometric methods often used in analytical spectroscopy are evaluated; principal component regression, partial least-squares regression, and artificial neural networks. These models are evaluated based on goodness-of-fit metrics, root mean-squared error, and their achievable limits of detection (LoDs). Partial least squares proved superior for determining content of iron and nickel in plutonium metal, yielding LoDs of 15 and 20 ppm, respectively. These results of identifying the undesirable trace elements in plutonium components are critical for applications such as fabricating radioisotope thermoelectric generators or nuclear fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Smart Methane Emission Detection System Development (Final Report)

Working with the Department of Energy’s National Energy Technology Laboratory, Southwest Research Institute® (SwRI®) developed a system to identify methane leaks reliably, accurately, and autonomously at critical midstream sections of the natural gas distribution network in real- time for the purpose of mitigating methane emissions using Optical Gas Imaging (OGI) cameras. SwRI’s Smart Leak Detection – Methane (SLED/M) adds a high degree of automation to the process of methane leak detection to minimize sources of human error, minimize response time to a leak event, and maximize midstream visibility. Furthermore, SwRI has been working towards integrating Quantitative OGI (QOGI) capabilities into this existing technology. By leveraging Deep Learning, SwRI now has the capability to estimate fugitive emission leak rates quickly and reliably, which allows operators to detect emissions, quantify leak rate, prioritize repairs, and validate the repairs in a single instrument. The next generation QOGI technology leverages the same cameras used in Leak Detection and Repair (LDAR) programs, with improvements in safety and speed for traditional quantification-based repairs, ultimately leading to less overhead cost for the operators. The goals for this research were to develop two types of models with the following goals: 1. Run in real-time on the edge (≥ 12 Hz) 2. Classification: Achieve less than 5% false positive detection 3. Classification: Achieve ≥ 95% methane plume detection rate 4. Regression: achieve ≤ 10 standard cubic feet per hour (scfh) prediction > 70% of the time In order to achieve these results, multiple infrared (IR) and other sensors were investigated in tandem with the midwave IR (MWIR) OGI to provide additional information to train the underlying models. Information on atmospheric conditions including humidity, temperature, pressure, and solar radiation was provided by a weather station. Several machine learning and deep learning architectures and methods, including looking at quantized classification networks and regressions networks, were explored. As further data was collected, curated, and labeled, it allowed for more refined regressive networks to be adequately trained, leading to better insight into the true flow rates being observed. An important valuable deliverable of this research effort was the development of an advanced network which underwent multiple iterations capable of giving a continuous output. The current network has a predicted mean average percentage error (MAPE) of 12.3% just outside our target goal of 10.00%, but an accuracy of 97.78% at ±50 scfh, well within the overall goal for the Department of Energy (DOE) program. Upon closer inspection, it was observed that more than 10% of datapoints contributing to the MAPE predictions were the result of low flow rate predictions and are beyond the sensitivity of instrument measurement as a result of normal operational variation and noise.

03 NATURAL GAS↗

Smart Methane Emission Detection System Development (Final Report)

Working with the Department of Energy's National Energy Technology Laboratory, Southwest Research Institute® (SwRI®) developed a system to identify methane leaks reliably, accurately, and autonomously at critical midstream sections of the natural gas distribution network in real-time for the purpose of mitigating methane emissions using Optical Gas Imaging (OGI) cameras. SwRI's Smart Leak Detection – Methane (SLED/M) adds a high degree of automation to the process of methane leak detection to minimize sources of human error, minimize response time to a leak event, and maximize midstream visibility. Furthermore, SwRI has been working towards integrating Quantitative OGI (QOGI) capabilities into this existing technology. By leveraging Deep Learning, SwRI now has the capability to estimate fugitive emission leak rates quickly and reliably, which allows operators to detect emissions, quantify leak rate, prioritize repairs, and validate the repairs in a single instrument. The next generation QOGI technology leverages the same cameras used in Leak Detection and Repair (LDAR) programs, with improvements in safety and speed for traditional quantification-based repairs, ultimately leading to less overhead cost for the operators. The goals for this research were to develop two types of models with the following goals: Run in real-time on the edge (≥ 12 Hz), Classification: Achieve less than 5% false positive detection, Classification: Achieve ≥ 95% methane plume detection rate, Regression: achieve ≤ 10 standard cubic feet per hour (scfh) prediction > 70% of the time. In order to achieve these results, multiple infrared (IR) and other sensors were investigated in tandem with the midwave IR (MWIR) OGI to provide additional information to train the underlying models. Information on atmospheric conditions including humidity, temperature, pressure, and solar radiation was provided by a weather station. Several machine learning and deep learning architectures and methods, including looking at quantized classification networks and regressions networks, were explored. As further data was collected, curated, and labeled, it allowed for more refined regressive networks to be adequately trained, leading to better insight into the true flow rates being observed. An important valuable deliverable of this research effort was the development of an advanced network which underwent multiple iterations capable of giving a continuous output. The current network has a predicted mean average percentage error (MAPE) of 12.3% just outside our target goal of 10.00%, but an accuracy of 97.78% at ±50 scfh, well within the overall goal for the Department of Energy (DOE) program. Upon closer inspection, it was observed that more than 10% of datapoints contributing to the MAPE predictions were the result of low flow rate predictions and are beyond the sensitivity of instrument measurement as a result of normal operational variation and noise.

03 NATURAL GAS↗

Validation of ISCCP cloud detections

This paper describes the validation of the International Satellite Cloud Climatology project (ISCCP)cloud detections by verifying the accuracy of the infrared clear-sky radiances. Comparison of retrieved surface temperatures to other measurements shows that bias errors are less than 2 K and random errors are about 2 K for sea surface (monthly means at 280-km scales) and that bias errors are less than 2 K and random errors are about 4 K for land surfaces (3 hourly at 280-km scales). Bias errors over a few persistently cloudy locations are sometimes -(2-4) K and over winter sea ice may be about +2 K. Surface reflectances are confirmed to be within 3% of other measurements and models for ocean, except for sun glint geometries, and to be within 3%-5% for land surfaces. Sufficiently accurate validation data are not avilable for visible reflectances of sea ice and snow-covered land, but some tests of specific cases suggest that errors are approximately 10%. These errors in clear-sky radiances suggest uncertainties in the ISCCP cloud detections of about 10% with a small (3%-6%) negative bias over land. Some specific regions exhibit both larger rms uncertainties and somewhat larger biases in cloud amount approaching 10%. ISCCP cloud detections are more in error over the polar regions than anywhere else. Based on comparisons with an anlysis of radiances measured at other wavelengths, the ISCCP analysis appears to miss 15%-25% of the clouds in summer but only 5%-10% of the winter clouds.

Rossow, William B.↗

The Role of Fire in Global Forest Loss Dynamics

Fires, among other forms of natural and anthropogenic disturbance, play a central role in regulating the location, composition and biomass of forests. Understanding the role of fire in global forest loss is crucial in constraining land-use change emissions and the global carbon cycle. We analysed the relationship between forest loss and fire at 500 m resolution based on satellite-derived data for the 2003–2018 period. Satellite fire data included burned area and active fire detections, to best account for large and small fires, respectively. We found that, on average, 38 ± 9% (± range) of global forest loss was associated with fire, and this fraction remained relatively stable throughout the study period. However, the fraction of fire-related forest loss varied substantially on a regional basis, and showed statistically significant trends in key tropical forest areas. Decreases in the fraction of fire-related forest loss were found where deforestation peaked early in our study period, including the Amazon and Indonesia while increases were found for tropical forests in Africa. The inclusion of active fire detections accounted for 41%, on average, of the total fire-related forest loss, with larger contributions in small clearings in interior tropical forests and human-dominated landscapes. Comparison to higher-resolution fire data with resolutions of 375 and 20 m indicated that commission errors due to coarse resolution fire data largely balanced out omission errors due to missed small fire detections for regional to continental-scale estimates of fire-related forest loss. Besides an improved understanding of forest dynamics, these findings may help to refine and separate fire-related and non-fire-related land-use change emissions in forested ecosystems.

Dan van Wees↗

Autonomous Phase Retrieval Calibration

The Palomar Adaptive Optics System actively corrects for changing aberrations in light due to atmospheric turbulence. However, the underlying internal static error is unknown and uncorrected by this process. The dedicated wavefront sensor device necessarily lies along a different path than the science camera, and, therefore, doesn't measure the true errors along the path leading to the final detected imagery. This is a standard problem in adaptive optics (AO) called "non-common path error." The Autonomous Phase Retrieval Calibration (APRC) software suite performs automated sensing and correction iterations to calibrate the Palomar AO system to levels that were previously unreachable.

Estlin, Tara A.↗

Follow-up observations for IceCube-170922A: Detection of rapid near-infrared variability and intensive monitoring of TXS 0506+056

Abstract We present our follow-up observations to search for an electromagnetic counterpart of the IceCube high-energy neutrino IceCube-170922A. Monitoring observations of a likely counterpart, TXS 0506+056, are also described. First, we quickly took optical and near-infrared images of seven flat-spectrum radio sources within the IceCube error region right after the neutrino detection and found a rapid flux decline of TXS 0506+056 in Kanata/HONIR J-band data. Motivated by this discovery, intensive follow-up observations of TXS 0506+056 were continuously performed, including our monitoring imaging observations, spectroscopic observations, and polarimetric observations in optical and near-infrared wavelengths. TXS 0506+056 showed a large-amplitude (∼1.0 mag) variability in a time scale of several days or longer, although no significant variability was detected in a time scale of a day or shorter. TXS 0506+056 also showed a bluer-when-brighter trend in optical and near-infrared wavelengths. Structure functions of the variabilities were examined and indicate that TXS 0506+056 is not a special blazar in terms of optical variability. Polarization measurement results of TXS 0506+056 are also discussed.

(galaxies:) BL Lacertae objects: general↗

Smart Methane Emission Detection System Development Final Report

Working with the Department of Energy's National Energy Technology Laboratory, Southwest Research Institute® (SwRI®) developed a system to identify methane leaks reliably, accurately, and autonomously at critical midstream sections of the natural gas distribution network in real- time for the purpose of mitigating methane emissions using Optical Gas Imaging (OGI) cameras. SwRI's Smart Leak Detection – Methane (SLED/M) adds a high degree of automation to the process of methane leak detection to minimize sources of human error, minimize response time to a leak event, and maximize midstream visibility. Furthermore, SwRI has been working towards integrating Quantitative OGI (QOGI) capabilities into this existing technology. By leveraging Deep Learning, SwRI now has the capability to estimate fugitive emission leak rates quickly and reliably, which allows operators to detect emissions, quantify leak rate, prioritize repairs, and validate the repairs in a single instrument. The next generation QOGI technology leverages the same cameras used in Leak Detection and Repair (LDAR) programs, with improvements in safety and speed for traditional quantification-based repairs, ultimately leading to less overhead cost for the operators.

03 NATURAL GAS↗

Sampling Technique for Robust Odorant Detection Based on MIT RealNose Data

This technique enhances the detection capability of the autonomous Real-Nose system from MIT to detect odorants and their concentrations in noisy and transient environments. The lowcost, portable system with low power consumption will operate at high speed and is suited for unmanned and remotely operated long-life applications. A deterministic mathematical model was developed to detect odorants and calculate their concentration in noisy environments. Real data from MIT's NanoNose was examined, from which a signal conditioning technique was proposed to enable robust odorant detection for the RealNose system. Its sensitivity can reach to sub-part-per-billion (sub-ppb). A Space Invariant Independent Component Analysis (SPICA) algorithm was developed to deal with non-linear mixing that is an over-complete case, and it is used as a preprocessing step to recover the original odorant sources for detection. This approach, combined with the Cascade Error Projection (CEP) Neural Network algorithm, was used to perform odorant identification. Signal conditioning is used to identify potential processing windows to enable robust detection for autonomous systems. So far, the software has been developed and evaluated with current data sets provided by the MIT team. However, continuous data streams are made available where even the occurrence of a new odorant is unannounced and needs to be noticed by the system autonomously before its unambiguous detection. The challenge for the software is to be able to separate the potential valid signal from the odorant and from the noisy transition region when the odorant is just introduced.

Duong, Tuan A.↗

Spectral Properties and Coding Transitions of Haar-Random Quantum Codes

A quantum error-correcting code with a nonzero error threshold undergoes a mixed-state phase transition when the error rate reaches that threshold. We explore this phase transition for Haar-random quantum codes, in which the logical information is encoded in a random subspace of the physical Hilbert space. We focus on the spectrum of the encoded system density matrix as a function of the rate of uncorrelated, single-qudit errors. For low error rates, this spectrum consists of well-separated bands, representing errors of different weights. As the error rate increases, the bands for high-weight errors merge. The evolution of these bands with increasing error rate is well described by a simple analytic ansatz. Using this ansatz, as well as an explicit calculation, we show that the threshold for Haar-random quantum codes saturates the hashing bound, and thus coincides with that for random stabilizer codes. For error rates that exceed the hashing bound, typical errors are uncorrectable, but postselected error correction remains possible until a much higher detection threshold. Postselection can in principle be implemented by projecting onto subspaces corresponding to low-weight errors, which remain correctable past the hashing bound.

decoherence↗

Monitoring of Ionic Silver Biocide with Capacitively-Coupled Contactless Conductivity Detection (C4D)

Monitoring of biocide dosing in spacecraft potable water systems is desirable to ensure dosing system operation and resultant microbial control. Electrolytic conductivity is linearly related to the concentration ionic silver (Ag+, the baseline biocide for future NASA missions) chemically dosed into highly purified water, and could serve as a proxy measurement. Traditional conductivity cells rely on immersed metal or graphite electrodes, which may potentially be subject to significant current-induced or auto-galvanic deposition of Ag+. Furthermore, oxide fouling may potentially induce measurement errors. Capacitively-coupled contactless conductivity detection (C4D) is a promising alternative. C4D uses electrodes placed outside an inert, non-conductive flow path, potentially mitigating such problems. We identified and purchased a commercial C4D system with claimed performance (conductivity range: 20 nS/cm to 4 µS/cm) appropriate for this application. We characterized the instrument’s performance with conductivity standards and Ag+ solutions. We began investigations considering practical and long-term detector operation, including potential current-induced deposition of conductive deposits at the tubing wall. In addition, we designed a side-stream flow system to provide liquid flow through the narrow tubing (1/16” outer diameter) required by the detector and characterized the performance of the combined C4D detector/flow system. Finally, we completed theoretical modeling of expected conductivity change with multiple dosing techniques and water chemistries.

Lance Dean Delzeit↗

Effect of model uncertainty on failure detection - The threshold selector

The performance of all failure detection, isolation, and accomodation (DIA) algorithms is influenced by the presence of model uncertainty. A unique framework is presented to incorporate a knowledge of modeling error in the analysis and design of failure detection systems. The tools being used are very similar to those in robust control theory. A concept is introduced called the threshold selector, which is a nonlinear inequality whose solution defines the set of detectable sensor failure signals. The threshold selector represents an innovative tool for analysis and synthesis of DIA algorithms. It identifies the optimal threshold to be used in innovations-based DIA algorithms. The optimal threshold is shown to be a function of the bound on modeling errors, the noise properties, the speed of DIA filters, and the classes of reference and failure signals. The size of the smallest detectable failure is also determined. The results are applied to a multivariable turbofan jet engine example, which demonstrates improvements compared to previous studies.

Emami-Naeini, Abbas↗