Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electronic noise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Single-Photon-Sensitive HgCdTe Avalanche Photodiode Detector

The purpose of this program was to develop single-photon-sensitive short-wavelength infrared (SWIR) and mid-wavelength infrared (MWIR) avalanche photodiode (APD) receivers based on linear-mode HgCdTe APDs, for application by NASA in light detection and ranging (lidar) sensors. Linear-mode photon-counting APDs are desired for lidar because they have a shorter pixel dead time than Geiger APDs, and can detect sequential pulse returns from multiple objects that are closely spaced in range. Linear-mode APDs can also measure photon number, which Geiger APDs cannot, adding an extra dimension to lidar scene data for multi-photon returns. High-gain APDs with low multiplication noise are required for efficient linear-mode detection of single photons because of APD gain statistics -- a low-excess-noise APD will generate detectible current pulses from single photon input at a much higher rate of occurrence than will a noisy APD operated at the same average gain. MWIR and LWIR electron-avalanche HgCdTe APDs have been shown to operate in linear mode at high average avalanche gain (M > 1000) without excess multiplication noise (F = 1), and are therefore very good candidates for linear-mode photon counting. However, detectors fashioned from these narrow-bandgap alloys require aggressive cooling to control thermal dark current. Wider-bandgap SWIR HgCdTe APDs were investigated in this program as a strategy to reduce detector cooling requirements.

Huntington, Andrew↗

The association of nonthermal electrons with non-flaring coronal transients

A close temporal and spatial association has been found between erupting filaments/coronal transients and radio noise storm continua. The three transients studied occurred away from active regions and are members of a class not usually accompanied by chromospheric emission. The data analyzed were from the S-054 soft X-ray telescope on Skylab and from one- and two-dimensional interferometers at meter and decameter wavelengths at Nancay and Clark Lake observatories. Calculations confirmed that observed microwave radiation from the transients is due to thermal bremsstrahlung. The results are consistent with an interpretation of heating of an increased amount of coronal plasma by nonthermal, 10-100 keV electrons. Three possibilities for the source of the material are described: (1) the filament material; (2) evaporation from the chromosphere or transition region; and (3) via a long-lived reconnection process.

Webb, D. F.↗

Multi-channel, multi-template event reconstruction for SuperCDMS data using machine learning

SuperCDMS SNOLAB uses kilogram-scale germanium and silicon detectors to search for dark matter. Each detector has Transition Edge Sensors (TESs) patterned on the top and bottom faces of a large crystal substrate, with the TESs electrically grouped into six phonon readout channels per face. Noise correlations are expected among a detector's readout channels, in part because the channels and their readout electronics are located in close proximity to one another. Moreover, owing to the large size of the detectors, energy deposits can produce vastly different phonon propagation patterns depending on their location in the substrate, resulting in a strong position dependence in the readout-channel pulse shapes. Both of these effects can degrade the energy resolution and consequently diminish the dark matter search sensitivity of the experiment if not accounted for properly. We present a new algorithm for pulse reconstruction, mathematically formulated to take into account correlated noise and pulse shape variations. This new algorithm fits N readout channels with a superposition of M pulse templates simultaneously - hence termed the N$\times$M filter. We describe a method to derive the pulse templates using principal component analysis (PCA) and to extract energy and position information using a gradient boosted decision tree (GBDT). We show that these new N$\times$M and GBDT analysis tools can reduce the impact from correlated noise sources while improving the reconstructed energy resolution for simulated mono-energetic events by more than a factor of three and for the 71Ge K-shell electron-capture peak recoils measured in a previous version of SuperCDMS called CDMSlite to $<$ 50 eV from the previously published value of $\sim$100 eV. These results lay the groundwork for position reconstruction in SuperCDMS with the N$\times$M outputs.

Albakry, M. F. [British Columbia U.; TRIUMF]↗

Quantum Interferometry

Recently, several researchers, including yours truly, have been able to demonstrate theoretically that quantum photon entanglement has the potential to also revolutionize the entire field of optical interferometry, by providing many orders of magnitude improvement in interferometer sensitivity. The quantum entangled photon interferometer approach is very general and applies to many types of interferometers. In particular, without nonlocal entanglement, a generic classical interferometer has a statistical-sampling shot-noise limited sensitivity that scales like 1/Sqrt[N], where N is the number of particles (photons, electrons, atoms, neutrons) passing through the interferometer per unit time. However, if carefully prepared quantum correlations are engineered between the particles, then the interferometer sensitivity improves by a factor of Sqrt[N] (square root of N) to scale like 1/N, which is the limit imposed by the Heisenberg Uncertainty Principle. For optical (laser) interferometers operating at milliwatts of optical power, this quantum sensitivity boost corresponds to an eight-order-of-magnitude improvement of signal to noise. Applications are to tests of General Relativity such as ground and orbiting optical interferometers for gravity wave detection, Laser Interferometer Gravity Observatory (LIGO) and the European Laser Interferometer Space Antenna (LISA), respectively.

Dowling, Jonathan P.↗

Low power implementation of high frequency SiPM readout for Cherenkov and scintillation detectors in TOF-PET

State-of-the-art (SoA) electronic readout for silicon photomultiplier (SiPM)-based scintillation detectors that demonstrate experimental limits in achievable coincidence time resolution (CTR) leverage low noise, high frequency signal processing to facilitate a single photon time response that is near the limit of the SiPMs architecture. This readout strategy can optimally exploit fast luminescence and prompt photon populations, and promising measurements show detector concepts employing this readout can greatly advance PET detector CTR, relative to SoA in clinical systems. However, the technique employs power hungry components which make the electronics chain impractical for channel-dense time-of-flight (TOF)-PET detectors. We have developed and tested a low noise and high frequency readout circuit which is performant at low power and consists of discrete elements with small footprints, making it feasible for integration into TOF-PET detector prototypes. A 3 × 3 mm 2 Broadcom SiPM with this readout chain exhibited sub-100 ps single photon time resolution at 10 mW of power consumption, with a relatively minor performance degradation to 120 ± 2 ps FWHM at 5 mW. CTR measurements with 3 × 3 × 20 mm 3 LYSO and fast LGSO scintillators demonstrated 127 ± 3 ps and 113 ± 2 ps FWHM at optimal power operation and 133 ± 2 ps and 121 ± 3 ps CTR at 5 mW. BGO crystals 3 × 3 × 20 mm 3 in size show 271 ± 5 ps FWHM CTR (1174 ± 14 ps full-width-at-tenth-maximum (FWTM)) at optimal power dissipation and 289 ± 8 ps (1296 ± 33 ps FWTM) at 5 mW. The compact and low power readout topology that achieves this performance thereby offers a platform to greatly advance PET system CTR and also opportunities to provide high performance TOF-PET at reduced material cost.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The influence of secondary electron yield uncertainty on the single-sided multipacting in dielectrics

Multipacting is an electrical discharge caused by the emission of secondary electrons which can occur in vacuum radio frequency systems. Generally multipacting is highly undesirable obstacle, which increases the noise level as well as the return loss of radio frequency systems. Therefore, a prediction of multipacting is necessary to avoid it during radio frequency system design. In this regard, the accurate evaluation of the factors that affect multipacting is required. One of the critical factors determining the multipacting development is the secondary electron yield of the material. In practice the emission properties of materials are not known very accurately. There are uncertainties in the measured values of this yield. In this paper, the generalized Polynomial Chaos (gPC) method is used to quantify uncertainty of the secondary electron yield. This method is verified by Monte Carlo simulation. The effect of uncertainty for two secondary electron yield parameters is then investigated on the multipacting using gPC method.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Changes in electric field noise due to thermal transformation of a surface ion trap

Here, we aim to illuminate how the microscopic properties of a metal surface map to its electric field noise characteristics. In our system, prolonged heat treatments of a metal film can induce a rise in the magnitude of the electric field noise generated by the surface of that film. We refer to this heat-induced rise in noise magnitude as a thermal transformation. The underlying physics of this thermal transformation process is explored through a series of heating, milling, and electron treatments performed on a single surface ion trap. Between these treatments, 40 Ca + ions trapped 70 μm above the surface of the metal are used as detectors to monitor the electric field noise at frequencies close to 1 MHz. An Auger spectrometer is used to track changes in the composition of the contaminated metal surface. With these tools we investigate contaminant deposition, chemical reactions, and atomic restructuring as possible drivers of thermal transformations.

36 MATERIALS SCIENCE↗

Excitation of low-frequency waves by auroral electron beams

The electron distribution functions measured by the Dynamics Explorer 1 satellite during an auroral pass in 1981 are used in a linear instability analysis of low-frequency electromagnetic and electrostatic waves near and below the hydrogen gyrofrequency. It is suggested that the low-frequency electric and magnetic noise in the auroral zone might be explained by O and H electromagnetic ion cyclotron waves excited by energetic electron beams. An instability analysis suggests that upward and downward streaming electrons throughout the central plasma sheet region provide the free energy for heating oxygen ion through oxygen electrostatic ion cyclotron waves.

Lin, C. S.↗

Low Noise Camera for Suborbital Science Applications

Low-cost, commercial-off-the-shelf- (COTS-) based science cameras are intended for lab use only and are not suitable for flight deployment as they are difficult to ruggedize and repackage into instruments. Also, COTS implementation may not be suitable since mission science objectives are tied to specific measurement requirements, and often require performance beyond that required by the commercial market. Custom camera development for each application is cost prohibitive for the International Space Station (ISS) or midrange science payloads due to nonrecurring expenses (~$2,000 K) for ground-up camera electronics design. While each new science mission has a different suite of requirements for camera performance (detector noise, speed of image acquisition, charge-coupled device (CCD) size, operation temperature, packaging, etc.), the analog-to-digital conversion, power supply, and communications can be standardized to accommodate many different applications. The low noise camera for suborbital applications is a rugged standard camera platform that can accommodate a range of detector types and science requirements for use in inexpensive to mid range payloads supporting Earth science, solar physics, robotic vision, or astronomy experiments. Cameras developed on this platform have demonstrated the performance found in custom flight cameras at a price per camera more than an order of magnitude lower.

Hyde, David↗

Plasma waves in the range of the lower hybrid frequency - ISEE 1 and 2 observations at the earth's bow shock

This report presents a characterization of plasma wave noise in the range of the lower hybrid frequency associated with 65 crossings of earth's bow shock observed by the ISEE 1 and 2 satellites. Wave growth generally becomes detectable at the upstream edge of the shock foot, increases at the upstream edge of the shock ramp, peaks within the ramp, and then quickly decays to steady downstream values. The upstream extent of the noise is on the same order as that of specularly reflected gyrating ions. Similar profiles were observed in subcritical and supercritical shocks, and no special behavior was associated with the first critical Mach number. Spectra in the foot and ramp were similar in shape, although the noise was 1 to 2 orders of magnitude more intense in the shock ramps than in the feet. Electric field intensities are positively correlated with solar wind speed and inversely related to electron beta and Mach number. Magnetic components are positively correlated with Mach number and beta. The results are generally consistent with suggestions that the noise consists of lower hybrid waves driven by reflected gyrating ions in the foot, and by additional instabilities, such as the cross-field current, in the shock ramp.

Mellott, M. M.↗

Low Frequency Interstellar Scattering and Pulsar Observations

Radio astronomy at frequencies from 2 to 30 MHz challenges time tested methods for extracting usable information from observations. One fundamental reason for this is that propagation effects due to the magnetoionic ionosphere, interplanetary medium, and interstellar matter (ISM) increase strongly with wavelength. The problems associated with interstellar scattering off of small scale irregularities in the electron density are addressed. What is known about interstellar scattering is summarized on the basis of high frequency observations, including scintillation and temporal broadening of pulsars and angular broadening of various galactic and extragalactic radio sources. Then those high frequency phenomena are addressed that are important or detectable at low frequencies. The radio sky becomes much simpler at low frequencies, most pulsars will not be seen as time varying sources, intensity variations will be quenched or will occur on time scales much longer than a human lifetime, and many sources will be angularly broadened and/or absorbed into the noise. Angular broadening measurements will help delineate the galactic distribution and power spectrum of small scale electron density irregularities.

Cordes, James M.↗

Three MMIC Amplifiers for the 120-to-200 GHz Frequency Band

Closely following the development reported in the immediately preceding article, three new monolithic microwave integrated circuit (MMIC) amplifiers that would operate in the 120-to-200-GHz frequency band have been designed and are under construction at this writing. The active devices in these amplifiers are InP high-electron-mobility transistors (HEMTs). These amplifiers (see figure) are denoted the LSLNA150, the LSA200, and the LSA185, respectively. Like the amplifiers reported in the immediately preceding article, the LSLNA150 (1) is intended to be a prototype of low-noise amplifiers (LNAs) to be incorporated into spaceborne instruments for sensing cosmic microwave background radiation and (2) has potential for terrestrial use in electronic test equipment, passive millimeter-wave imaging systems, radar receivers, communication receivers, and systems for detecting hidden weapons. The HEMTs in this amplifier were fabricated according to 0.08- m design rules of a commercial product line of InP HEMT MMICs at HRL Laboratories, LLC, with a gate geometry of 2 fingers, each 15 m wide. On the basis of computational simulations, this amplifier is designed to afford at least 15 dB of gain, with a noise figure of no more than about 6 dB, at frequencies from 120 to 160 GHz. The measured results of the amplifier are shown next to the chip photo, with a gain of 16 dB at 150 GHz. Noise figure work is ongoing. The LSA200 and the LSA185 are intended to be prototypes of transmitting power amplifiers for use at frequencies between about 180 and about 200 GHz. These amplifiers have also been fabricated according to rules of the aforesaid commercial product line of InP HEMT MMICs, except that the HEMTs in these amplifiers are characterized by a gate geometry of 4 fingers, each 37 m wide. The measured peak performance of the LSA200 is characterized by a gain of about 1.4 dB at a frequency of 190 GHz; the measured peak performance of the LSA185 is characterized by a gain of about 2.7 dB at a frequency of 181 GHz. The measured gain results of each chip are shown next to their respective photos.

Samoska, Lorene↗

Hybrid analog/digital, large format, photon counting detectors for astronomy

The development of a new microchannel plate photon-counting detector with an analog readout method based on a resistive anode is reported. This detector exhibits extremely high, stable electron gains of 10 to the 8th. At this gain, the spatial resolution is no longer primarily limited by the noise of the resistive anode, so that digital methods of readout, such as discrete conductors, lose their advantage. These detectors can be readily scaled to 40 mm and 70 mm formats to match plate scales of 2-m (and larger) telescopes. New, high speed digital electronics fully exploit the high spatial and time resolution made possible by gains of this level. Analysis of the theoretical performance of this detector shows that the major limitation to the spatial resolution is the proximity focus of the photocathode and the first microchannel plate. The detector has been mated to an echelle spectrograph developed.

Crocker, J.↗

W-band system-on-chip electron cyclotron emission imaging system on DIII-D

Monolithic, millimeter wave “system-on-chip” (SoC) technology has been employed in heterodyne receiver integrated circuit radiometers in a newly developed Electron Cyclotron Emission Imaging (ECEI) system on the DIII-D tokamak for 2D electron temperature profile and fluctuation evolution diagnostics. Here, a prototype module operating in E-band (72-80 GHz) was first employed in a 2 x 10 element array that demonstrated significant improvements over the previous quasi-optical Schottky diode mixer arrays during the 2018 operational campaign of the DIII-D tokamak. For compatibility with International Thermonuclear Experimental Reactor (ITER) relevant scenarios on DIII-D, the SoC ECEI system was upgraded with 20 horn-waveguide receiver modules. Each individual module contains a University of California at Davis designed W-band (75 -110 GHz) receiver die that integrates a broadband low noise amplifier (LNA), a double balanced down-converting mixer, and a x4 multiplier on the local oscillator (LO) chain. A x2 multiplier and two IF amplifiers are packaged and selected to further boost the signal strength as well as downconvert the signal frequency. The upgraded W-band array exhibits > 30 dB additional gain and 20x improvement in noise temperature comparing with the previous Schottky diode radio frequency (RF) mixer input systems; an internal 8 times multiplier chain is used to bring down the LO frequency below 12 GHz, thereby obviating the need for a large aperture for quasi-optical LO coupling and replacing it with coaxial connectors. The horn-waveguide shielding housing avoids out-of-band noise interference on each individual module. The upgraded ECEI system plays an important role for absolute electron temperature evolution and fluctuation measurements for edge and core region transport physics studies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Solution-phase sample-averaged single-particle spectroscopy of quantum emitters with femtosecond resolution

Here, the development of many optical quantum technologies depends on the availability of solid-state single quantum emitters with near-perfect optical coherence. However, a standing issue that limits systematic improvement is the significant sample heterogeneity and lack of mechanistic understanding of microscopic energy flow at the single emitter level and ultrafast timescales. Here we develop solution-phase single-particle pump-probe spectroscopy with photon correlation detection that captures sample-averaged dynamics in single molecules and/or defect states with unprecedented clarity at femtosecond resolution. We apply this technique to single quantum emitters in two-dimensional hexagonal boron nitride, which suffers from significant heterogeneity and low quantum efficiency. From millisecond to nanosecond timescales, the translation diffusion, metastable-state-related bunching shoulders, rotational dynamics, and antibunching features are disentangled by their distinct photon-correlation timescales, which collectively quantify the normalized two-photon emission quantum yield. Leveraging its femtosecond resolution, spectral selectivity and ultralow noise (two orders of magnitude improvement over solid-state methods), we visualize electron-phonon coupling in the time domain at the single defect level, and discover the acceleration of polaronic formation driven by multi-electron excitation. Corroborated with results from a theoretical polaron model, we show how this translates to sample-averaged photon fidelity characterization of cascaded emission efficiency and optical decoherence time. Our work provides a framework for ultrafast spectroscopy in single emitters, molecules, or defects prone to photoluminescence intermittency and heterogeneity, opening new avenues of extreme-scale characterization and synthetic improvements for quantum information applications.

36 MATERIALS SCIENCE↗

RapidEELS: machine learning for denoising and classification in rapid acquisition electron energy loss spectroscopy

Recent advances in detectors for imaging and spectroscopy have afforded in situ, rapid acquisition of hyperspectral data. While electron energy loss spectroscopy (EELS) data acquisition speeds with electron counting are regularly reaching 400 frames per second with near-zero read noise, signal to noise ratio (SNR) remains a challenge owing to fundamental counting statistics. In order to advance understanding of transient materials phenomena during rapid acquisition EELS, trustworthy analysis of noisy spectra must be demonstrated. In this study, we applied machine learning techniques to denoise high frame rate spectra, benchmarking with slower frame rate “ground truths”. The results provide a foundation for reliable use of low SNR data acquired in rapid, in-situ spectroscopy experiments. Such a tool-set is a first step toward both automation in microscopy as well as use of these methods to interrogate otherwise poorly understood transformations.

36 MATERIALS SCIENCE↗

Dynamic Focusing to Suppress Emittance Transfer in Crab-Crossing Flat Beam Collisions

Flat hadron beam collisions, though expected to enhance peak luminosity by about an order of magnitude, have not yet been demonstrated. We identify a new mechanism in which the hourglass-induced synchrobetatron resonance, when coupled to unavoidable machine fluctuations, drives emittance transfer and degrades the flat-beam condition. This effect becomes a critical limitation for maintaining flat hadron beams on operational timescales. Using Electron-Ion Collider (EIC) parameters, we show that it imposes stringent tolerances on machine noise. We further demonstrate that a dynamic focusing scheme, implemented by combining sextupoles with crab cavities, suppresses the resonance and relaxes these constraints, providing a practical path toward robust flat-beam collisions in future lepton-hadron colliders.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Model-based Reconstruction for Single Particle Cryo-Electron Microscopy

Single particle cryo-electron microscopy is a vital tool for 3D characterization of protein structures. A typical workflow involves acquiring projection images of a collection of randomly oriented particles, picking and classifying individual particle projections by orientation, and finally using the individual particle projections to reconstruct a 3D map of the electron density profile. The reconstruction is challenging because of the low signal-to-noise ratio of the data, the unknown orientation of the particles, and the sparsity of data especially when dealing with flexible proteins where there may not be sufficient data corresponding to each class to obtain an accurate reconstruction using standard algorithms. In this paper we present a model-based image reconstruction technique that uses a regularized cost function to reconstruct the 3D density map by assuming known orientations for the particles. Our method casts the reconstruction as minimizing a cost function involving a novel forward model term that accounts for the contrast transfer function of the microscope, the orientation of the particles and the center of rotation offsets. We combine the forward model term with a regularizer that enforces desirable properties in the volume to be reconstructed. Using simulated data, we demonstrate how our method can significantly improve upon the typically used approach.

Venkatakrishnan, Singanallur↗