Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electronic filters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Interplanetary Microlaser Transponders

The feasibility of an asynchronous (i.e. independently firing) interplanetary laser transponder, capable of ranging between Earth and Mars and using the automated SLR2000 Satellite Laser Ranging (SLR) system as an Earth base station, has been suggested. Since that time, we have received a small amount of discretionary funding to further explore the transponder concept and to develop and test an engineering breadboard. Candidate operational scenarios for acquiring and tracking the opposite laser terminal over interplanetary distances have been developed, and breadboard engineering parameters were chosen to reflect the requirements of an Earth-Mars link Laboratory tests have been devised to simulate the Earth- Mars link between two independent SLR2000 transceivers and to demonstrate the transfer of range and time in single photon mode. The present paper reviews the concept of the asynchronous microlaser transponder, the transponder breadboard design, an operational scenario recently developed for an asteroid rendezvous, and the laboratory test setup. The optical head of the transponder breadboard fits within a cylinder roughly 15 cm in diameter and 32 cm in length and is mounted in a commercial two axis gimbal driven by two computer-controlled stepper motors which allows the receiver optical axis to be centered on a simulated Earth image. The optical head is built around a small optical bench which supports a 14.7 cm diameter refractive telescope, a prototype 2 kHz SLR2000 microlaser transmitter, a quadrant microchannel plate photomultiplier (MCP/PMT), a CCD array camera, spatial and spectral filters, assorted lenses and mirrors, and protective covers and sun shields. The microlaser is end-pumped by a fiber-coupled diode laser array. An annular mirror is employed as a passive transmit/receive (T/R) switch in an aperture-sharing arrangement wherein the transmitted beam passes through the central hole and illuminates only the central 2.5 cm of the common telescope (adequate to achieve a 10 arcsecond full laser beam divergence) while the receiver uses the remainder of the 14.7 cm aperture. Additional electronic instrumentation includes the diode pump array and associated heat sink and current drivers, rubidium frequency standard, timing distribution module, range gate generator, a recently developed all-digital correlation range receiver, and system computer. Acquisition of the opposite transponder terminal requires a search within a three-dimensional volume determined by the initial pointing uncertainty and a maximum 500 microsecond uncertainty in the laser time of fire at the opposite terminal for totally uncorrelated Earth and spacecraft clocks. The angular search is aided by a sensitive CCD array capable of imaging the Earth, Moon, and surrounding stars within the nominal + 0.5 degree cone of uncertainty associated with the initial pointing of a spacecraft body or microwave communications dish.

Degnan, John J.↗

Trace Chemical Detection Using Intercalated MXenes as a Signal Enhancing Substrate in Optical Probes

MXenes are 2D materials composed of layered transition metal nitrides or carbides. These materials are synthesized by HF exfoliation from MAX phases (Ti{sub 3}AlC{sub 2}). The 2D nanomaterial was synthesized by the removal of the 'A' element, resulting in a Mxene product (Ti{sub 3}C{sub 2}). MXenes have the general formula M{sub n+1}X{sub n}T{sub x}, where M is an early transition metal, X is Carbon and/or Nitrogen, and T accounts for surface terminated functional groups such as Fluoride, hydroxyl, and oxygen. These materials have very unique properties, similar to graphene, that allows them to be applied in a variety of trace detection techniques including surface-enhanced Raman spectroscopy (SERS). MXenes have also been demonstrated to selectively uptake uranyl ion, UO{sub 2}{sup 2+}. If this property can be combined with SERS or fluorescence detection, it may be possible to use MXenes as the basis for an alternative method to kinetic phosphorescence analysis (KPA) for trace uranyl measurements. Objectives: To confirm that MXene Nano materials are suitable substrates for SERS and sensor development by enhancing Raman signaling. To determine if certain MXene preparation methods yield materials that are more suitable for trace sensing methods. To determine uranyl uptake properties of these MXene materials and test them for analytical signals. Sample Preparation: Preparation of Ti{sub 3}C{sub 2}MXene (at FSU). MXenes were prepared by etching Al from Ti{sub 3}AlC{sub 2} (MAX phase)material. Two etching techniques yield different MXene products: LiF/HCl: Milder reaction, larger MXene flakes. HF: Harsher reaction, smaller flakes, larger layer separation. Products washed to remove etchant, vacuum filtered, and dried. Dried MXene flakes are air-stable. Film preparation for sensor testing (at SRNL): Suspend powder in diH{sub 2}O, purge with Ar, sonicate for 30 min. Centrifuge and collect supernate with suspended particles. Observed LiF-etched Mxene yielded a higher density of particles and darker collected solution. Drop-cast (4 ml) supernate onto slides and dried with Ar. For Rhodamine B (RhB) testing, drop-cast 4 ml drops onto Mxene spots and dried with Ar. Scanning Electron Microscopy conditions: 10 kV Beam energy, high vacuum; Working distance of 8 mm; beam penetration depth appx. 4 microns, beam spot size appx. 2 nanometers. Results: Detection of aluminum correlates with bright spots on image. Presence of aluminum shows that LiF/HCl etching was less thorough than HF etching. Trace Cl detection in LiF images suggests incomplete rinsing. HF has smaller feature size, more layer structure, and increased homogeneity, consistent with expectations. Macroscopic Raman spectroscopy measurements: 532 nm excitation, ∼50 mW with a ∼100 micron spot size (InPhotonics RPB probe). Kaiser Optical Holospec f/1.8 spectrometer with cooled (-60 deg.C) Andor iDus OE420 CCD. LiF 1x supernate showed good signal for trace measurements of Rhodamine B. HF and 1/4x LiF supernates showed little Mxene or Rhodamine B signal. Low deposition densities led to excess background signal from glass slides. For LiF film, response is linear with Rhodamine B concentration over range tested. Will retest with Raman microscope (∼1 micron spot size) to characterize SERS of more dilute LiF and HF etched Mxenes. Conclusions: The LiF etched material was more suitable for macroscopic SERS measurements because it was more concentrated, resulting in a thicker film than the HF etched Mxene and diluted LiF sample. However, the other materials may give greater SERS enhancements, which we hope to determine from measurements with the Raman microscope. From characterization with SEM we concluded that the HF etched Mxene is more uniform/homogenous and has smaller particle size than the LiF etched Mxene. There is still aluminum present in both samples indicating that etching wasn't complete, but the removal of the aluminum was more efficient in the HF method. Path Forward: Observe SERS with Raman microscopy, to obtain better signals for the more diluted samples and be able to compare enhancement effects for the different MXenes. Characterize uranyl sorption into MXene films and test Raman and fluorescence signals. Revisit the etching conditions to improve removal of aluminum. FSU and SRNL will continue to collaborate to create and characterize different Mxene materials and test their usefulness for sensor applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Demonstration of a laser-driven, narrow spectral bandwidth x-ray source for collective x-ray scattering experiments

X-ray Thomson scattering (XRTS) is a powerful diagnostic technique that involves an x-ray source interacting with a dense plasma sample, resulting in a spectrum of elastically and inelastically scattered x-rays. Depending on the plasma conditions, one can measure a range of parameters from the resulting spectrum, including plasma temperature, electron density, and ionization state. To achieve sensitivity to collective electron oscillations, XRTS measurements require limited momentum transfer where the spectral separation of elastic and inelastic scattering is small. Such measurements require an x-ray probe source with a narrow bandwidth in order to reduce the spectral overlap between scattering contributions, allowing for the different features to be more precisely deconvolved. In this investigation, we discuss the theory behind how the bandwidth for a common XRTS probe, Zn He-α emission at 9 keV, can be reduced using a Cu K-edge filter.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Details of the neutral energy distribution and ionization source using spectrally resolved Balmer-alpha measurements on DIII-D

Spectrally resolved passive Balmer- α (D- α, H- α) measurements from the DIII-D 16 channel edge main-ion charge exchange recombination system confirm the presence of higher energy neutrals (“thermal” neutrals) in addition to the cold neutrals that recycle off the walls in the edge region of DIII-D plasmas. Charge exchange between thermal ions and edge neutrals transfers energy and momentum between the populations giving rise to thermal neutrals with energies approximating the ions in the pedestal region. Multiple charge exchange events in succession allow an electron to effectively take a random walk, transferring from ion to ion, providing a pathway of increasing energy and velocity, permitting a neutral to get deeper into the plasma before a final ionization event that contributes to the ion and electron particle fueling. Spectrally resolved measurements provide information about the density and velocity distribution of these neutrals, which has been historically valuable for validating Monte Carlo neutral models, which include the multi stage charge exchange dynamics. Here, in this study, a multi-channel set of such measurements is used to specifically isolate the details of the thermal neutrals that are responsible for fueling inside the pedestal top. Being able to separate the thermal from the cold emission overcomes several challenges associated with optical filter-based neutral density measurements. The neutral dynamics, deeper fueling by the thermal neutrals, and spectral measurement are modeled with the FIDASIM Monte Carlo collisional radiative code, which also produces synthetic spectra with a shape that is in close agreement with the measurements. By scaling the number of neutrals in the simulation to match the intensity of the thermal emission, we show it is possible to obtain local neutral densities and ionization source rates.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Non-Intrusive Measurements Using Femtosecond Laser in Atmospheric Pressure Plasma Jet

Femto-second (fs) lasers offer state-of-the art non-intrusive diagnostic capabilities in plasma flow environments. The diagnostics in plasma flows using a fs-laser that are relevant to this proposal include Two-photon Absorption Laser Induced Fluorescence (TALIF) for measuring the number density of an atomic species, and Femto-second Laser Electronic Excitation Tagging (FLEET) for performing velocity measurements in plasma flows. Various aspects of these diagnostics using fs-lasers are still an active domain of research. The TALIF technique has been used to measure the number density of atomic species in various plasma flow environments like atmospheric pressure plasma jet (APPJ) and arc-jet flows. This technique utilizes a fs-laser to excite an atomic species and the subsequent relaxation process through fluorescence is recorded to make measurements. A narrow band-pass filter is used to isolate the fluorescence signal that is in the infra-red regime. However, broad-band background emissions can potentially pass through the filter and induce noise in the TALIF signal. Particularly, arc-jet plasma flows inherently contain background emissions. In such plasma flow environments, in addition to the filter, the background-subtraction technique will play an important role in reducing the noise that is induced in the number density measurements using TALIF. The proposed research focuses on evaluating the effectiveness of a background-subtraction technique by measuring atomic oxygen using a femtosecond (fs) TALIF in APPJ with induced background emissions and comparing measurements obtained without inducing the emissions. Therefore, by quantifying the changes in the signal-to-noise ratio caused by a background-subtraction technique applied for APPJ, it will enable a better understanding of the uncertainties in the background subtracted fs-TALIF measurements for arc-jet plasma flows. In addition to this, FLEET will be used to obtain velocity in the APPJ, and the impact of background emissions will be analyzed. Under this effort, the experimenters and research personnel will gain the technical know-how in the operational and theoretical aspects of the advanced fs-laser-based diagnostic techniques. The knowledge gained in this process will then also directly be applied to a separate ONR funded project at the Aerodynamics Research Center (ARC), UT Arlington, related to arc-jet flow characterization.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thermal Infrared Imaging Spectrometer - An advanced optics technology instrument

Through the use of a special optical filter, the Thermal Infrared Imaging Spectrometer, an airborne multispectral IR imaging instrument operating in the thermal emission region (7.5-14 microns), will achieve signal-to-noise ratios greater than 600 with ambient temperature optics. This instrument will be used to do compositional surface mapping of the terrain, and will refine the ability to categorize rock families and types by providing much higher spectral resolution in the emission region than was previously available. Details of the optical system, the detector, the cooler system, and the support electronics are described.

Mahoney, Colin↗

Further development and flight test of an autonomous precision landing system using a parafoil

NASA Dryden Flight Research Center and NASA Johnson Space Center are jointly conducting a phased program to determine the feasibility of the autonomous recovery of a spacecraft using a ram-air parafoil system for the final stages of entry from space to a precision landing. The feasibility is being studied using a flight model of a spacecraft in the generic shape of a flattened biconic that weighs approximately 120 lb and is flown under a commercially available ram-air parafoil. Key components of the vehicle include the global positioning system (GPS) guidance for navigation, a flight control computer, an electronic compass, a yaw rate gyro, and an onboard data recorder. A flight test program is being used to develop and refine the vehicle. The primary flight goal is to demonstrate autonomous flight from an altitude of 3,000 m (10,000 ft) with a lateral offset of 1.6 km (1.0 mi) to a precision soft landing. This paper summarizes the progress to date. Much of the navigation system has been tested, including a heading tracker that was developed using parameter estimation techniques and a complementary filter. The autoland portion of the autopilot is still in development. The feasibility of conducting the flare maneuver without servoactuators was investigated as a means of significantly reducing the servoactuator rate and load requirements.

Murray, James E.↗

Power Electronics for a Miniaturized Arcjet

A 0.3 kW Power Processing Unit (PPU) was designed, tested on resistive loads, and then integrated with a miniaturized arcjet. The main goal of the design was to minimize size and mass while maintaining reasonable efficiency. In order to obtain the desired reductions in mass, simple topologies and control methods were considered. The PPU design incorporates a 50 kHz, current-mode-control, pulse-width-modulated (PWM), push-pull topology. An input voltage of 28 +/- 4V was chosen for compatibility with typical unregulated low voltage busses anticipated for smallsats. An efficiency of 0.90 under nominal operating conditions was obtained. The component mass of the PPU was 0.475 kg and could be improved by optimization of the output filter design. The estimated mass for a flight PPU based on this design is less than a kilogram.

Pinero, Luis R.↗

Double Shell Inertial Confinement Fusion X-Ray Spectral Analysis

At the National Ignition Facility (NIF), lasers are used to compress a double shell capsule with deuterium and tritium in order to create nuclear fusion processes. The lasers aim at the inside of a gold hohlraum which excite electrons which further release photons in the range of 0~20keV. The photons randomly disperse, ultimately either going towards the fuel capsule or back out the laser entrance holes. The photons that go towards the fuel capsule work towards the compression of the multi-shell capsule whereas the photons that leave the hohlraum have a chance at being picked up by the Lawrence Livermore National Lab’s ‘Dante’ photon detector. ‘Dante’ analyzes photon data by having 18 planar vacuum x-ray diodes (XRD) behind unique filters to differentiate data amongst various photon energies. The goal of the project was to analyze the characteristics of low and high energy photons released by the gold shell.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

UV Resonant Raman Spectrometer with Multi-Line Laser Excitation

A Raman spectrometer employs two or more UV (ultraviolet) laser wavel engths to generate UV resonant Raman (UVRR) spectra in organic sampl es. Resonant Raman scattering results when the laser excitation is n ear an electronic transition of a molecule, and the enhancement of R aman signals can be several orders of magnitude. In addition, the Ra man cross-section is inversely proportional to the fourth power of t he wavelength, so the UV Raman emission is increased by another fact or of 16, or greater, over visible Raman emissions. The Raman-scatter ed light is collected using a high-resolution broadband spectrograph . Further suppression of the Rayleigh-scattered laser light is provi ded by custom UV notch filters.

Lambert, James L.↗

The phase-2 particle x-ray temporal diagnostic for simultaneous measurement of multiple x-ray and nuclear emission histories from OMEGA implosions (invited)

Electron-temperature (T e ) measurements in implosions provide valuable diagnostic information, as T e is negligibly affected by residual flows and other non-thermal effects unlike ion-temperature inferred from a fusion product spectrum. In OMEGA cryogenic implosions, measurement of T e (t) can be used to investigate effects related to time-resolved hot-spot energy balance. The newly implemented phase-2 Particle X-ray Temporal Diagnostic (PXTD) utilizes four fast-rise (~15 ps) scintillator-channels with distinct x-ray filtering. Titanium and stepped aluminum filtering were chosen to maximize detector sensitivity in the 10–20 keV range, as it has been shown that these x rays have similar density and temperature weighting to the emitted deuterium–tritium fusion neutrons (DTn) from OMEGA Cryo-DT implosions. High quality data have been collected from warm implosions at OMEGA. These data have been used to infer spatially integrated T e (t) with <10% uncertainty at peak emission. Nuclear and x-ray emission histories are measured with 10 ps relative timing uncertainty for x rays and DTn and 12 ps for x rays and deuterium- 3 He protons (D 3 Hep). A future upgrade to the system will enable spatially integrated T e (t) with 40 ps time-resolution from cryogenic DT implosions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Accelerating self-consistent field iterations in Kohn-Sham density functional theory using a low-rank approximation of the dielectric matrix

We present an efficient preconditioning technique for accelerating the fixed-point iteration in real-space Kohn-Sham density functional theory (DFT) calculations. The preconditioner uses a low-rank approximation of the dielectric matrix (LRDM) based on Gâteaux derivatives of the residual of fixed-point iteration along appropriately chosen direction functions. We develop a computationally efficient method to evaluate these Gâteaux derivatives in conjunction with the Chebyshev filtered subspace iteration procedure, an approach widely used in large-scale Kohn-Sham DFT calculations. Further, we propose a variant of LRDM preconditioner based on adaptive accumulation of low-rank approximations from previous self-consistent field iterations, and also extend the LRDM preconditioner to spin-polarized Kohn-Sham DFT calculations. We demonstrate the robustness and efficiency of the LRDM preconditioner against other widely used preconditioners on a range of benchmark systems with sizes ranging from ~100 to 1100 atoms (~500–20,000 electrons). The benchmark systems include various combinations of metal-insulating-semiconducting heterogeneous material systems, nanoparticles with localized d orbitals near the Fermi energy, nanofilm with metal dopants, and magnetic systems. In all benchmark systems, the LRDM preconditioner converges robustly within 20–30 iterations. In contrast, other widely used preconditioners show slow convergence in many cases, as well as divergence of the fixed-point iteration in some cases. Lastly, we demonstrate the computational efficiency afforded by the LRDM method, with up to 3.4-fold reduction in computational cost for the total ground-state calculation compared to other preconditioners.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

PSC algorithm description

An overview of the performance seeking control (PSC) algorithm and details of the important components of the algorithm are given. The onboard propulsion system models, the linear programming optimization, and engine control interface are described. The PSC algorithm receives input from various computers on the aircraft including the digital flight computer, digital engine control, and electronic inlet control. The PSC algorithm contains compact models of the propulsion system including the inlet, engine, and nozzle. The models compute propulsion system parameters, such as inlet drag and fan stall margin, which are not directly measurable in flight. The compact models also compute sensitivities of the propulsion system parameters to change in control variables. The engine model consists of a linear steady state variable model (SSVM) and a nonlinear model. The SSVM is updated with efficiency factors calculated in the engine model update logic, or Kalman filter. The efficiency factors are used to adjust the SSVM to match the actual engine. The propulsion system models are mathematically integrated to form an overall propulsion system model. The propulsion system model is then optimized using a linear programming optimization scheme. The goal of the optimization is determined from the selected PSC mode of operation. The resulting trims are used to compute a new operating point about which the optimization process is repeated. This process is continued until an overall (global) optimum is reached before applying the trims to the controllers.

Nobbs, Steven G.↗

Black Carbon (Soot) Aerosol in the Lower Stratosphere and Upper Troposphere

We have used two approaches to measure BCA in the stratosphere. The first method consists of collecting aerosols by impaction on quartz rods, upon which are mounted strips of polystyrene filter material. Each 25 mm by 0.5 mm filter strip is alternately masked and exposed in 5 mm long sections. After sampling, the optical density of the exposed sections is measured and compared with the optical density of the masked (unexposed) sections. The filter strip is a Lambertian collector, the scattering property of which is not affected by the deposition of liquid sulfuric acid droplets which dominate the stratospheric aerosol. Hence, all attenuation greater in the exposed than in the non-exposed sections is due to absorption by BCA or rare opaque materials such as meteoritic iron. In a second approach we expose carbon-coated gold or palladium wires to air outside the aircraft boundary layer [Farlow et al., 1979; Pueschel et al., 1989]. With a field emission scanning electron microscope we are able to characterize BCA particles in addition to the dominant sulfuric acid droplets. Typically, soot is comprised of 20 nm diameter spheres linked together as branching chains or loosely packed aggregates (Figure 1a). The microscope has a lateral image resolution of 1.5 nm and can clearly resolve individual spheres making up BCA aggregates. Their morphology is uniquely different from that of the liquid sulfuric acid-water aerosol (Figure 1b). We approximate the size of each BCA particle by that of a sphere of equivalent volume and fit a lognormal size distribution to both the BCA and H2SO4/H2O aerosols. Both sampler types have been mounted on NASA's ER-2 high-altitude research aircraft (altitude ceiling of 70,000 feet), and on NASA's DC-8 (40,000 feet ceiling) aircraft to sample aerosols from a significant portion of the atmosphere.

Pueschel, R. F.↗

Effect of insulator surface conditioning on the pinch dynamics and x-ray production of a Ne-filled dense plasma focus

The dense plasma focus (DPF) can be an intense source of x rays, wherein the insulator sleeve strongly dictates the electrical breakdown, which subsequently affects the formation of a plasma sheath and a collapse phase. Experiments on a 25 kJ DPF (operated at 4.4 kJ) are carried out to demonstrate the influence of insulator surface morphology on the pinch structure, dynamics, and x-ray yield using a Ne fill. Two borosilicate insulators are directly compared, one with a smooth finish and the other machined with four circumferential grooves traversing the perimeter of the exterior insulator surface. Comparisons are made through same-shot imaging diagnostics of the evolving plasma sheath during breakdown, rundown, and at the pinch in addition to the time-resolved measurements of emitted x rays via filtered photodiodes. The presence of structures on the insulator sleeve reduces x-ray production across all fill pressures by a factor of 2.8 ± 2.4 on average and reduces the highest x ray producing shots by a factor of 5. ± 1.8. Observations of sheath asymmetry and inhomogeneity at lift-off are observed and correlated with subsequent observations of off-axis radial collapse. Taken together, this suggests that local variations in the insulator surface decrease the spatial uniformity of the sheath, leading to an azimuthally asymmetric focus, reduced electron densities, and, ultimately, degraded x-ray production.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Mass-selected ion–molecule cluster beam apparatus for ultrafast photofragmentation studies

We describe an apparatus for investigating the excited-state dissociation dynamics of mass-selected ion–molecule clusters by mass-resolving and detecting photofragment-ions and neutrals, in coincidence, using an ultrafast laser operating at high repetition rates. The apparatus comprises a source that generates ion–molecule clusters, a time-of-flight spectrometer, and a mass filter that selects the desired anions, and a linear-plus-quadratic reflectron mass spectrometer that discriminates the fragment anions after the femtosecond laser excites the clusters. The fragment neutrals and anions are then captured by two channeltron detectors. The apparatus performance is tested by measuring the photofragments: I – , CF 3 I – , and neutrals from photoexcitation of the ion–molecule cluster CF 3 I·I – using femtosecond UV laser pulses with a wavelength of 266 nm. Here, the experimental results are compared with our ground state and excited state electronic structure calculations as well as the existing results and calculations, with particular attention to the generation mechanism of the anion fragments and dissociation channels of the ion–molecule cluster CF 3 I·I – in the charge-transfer excited state.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Two-dimensional photometry of planetary nebulae

Monochromatic images of three planetary nebulae, NGC 6720, NGC 7662 and NGC 2392, were taken using narrow band interference filters centered on the forbidden emission lines of Oxygen I, II, III, Nitrogen II, Sulfur II and the permitted emission lines of Hydrogen I, Helium I and Helium II. The data was taken with a silicon intensified vidicon using the Palomar 1.5 meter telescope and was recorded digitally to an encoding level of 12 bits. The data was processed at the Image Processing Laboratory of the Jet Propulsion Laboratory. The calibrated images were used to investigate the three dimensional structure of the nebulae and to generate two-dimensional electron and temperature maps.

Kupferman, P. N.↗

Thermodynamics of the Solar Corona and Evolution of the Solar Magnetic Field as Inferred from the Total Solar Eclipse Observations of 11 July 2010

We report on multi-wavelength observations of the corona taken simultaneously in broadband white light, and in seven spectral lines, H-alpha 656.3 nm, Fe IX 435.9 nm, Fe X 637.4 nm, Fe XI 789.2 nm, Fe XIII 1074.7 nm, Fe XIV 530.3 nm and Ni XV 670.2 nm. The observations were made during the total solar eclipse of 11 July 2010 from the atoll of Tatakoto in French Polynesia. Simultaneous imaging with narrow bandpass filters in each of these spectral lines and in their corresponding underlying continua maximized the observing time during less than ideal observing conditions and yielded outstanding quality data. The application of two complementary image processing techniques revealed the finest details of coronal structures at 1" resolution in white light, and 6.5" in each of the spectral lines. This comprehensive wavelength coverage confirmed earlier eclipse findings that the solar corona has a clear two-temperature structure: The open field lines, expanding outwards from the solar surface, are characterized by electron temperatures near 1 X 10(exp 6) K, while the hottest plasma around 2X 10(exp 6) K resides in loop-like structures forming the bulges of streamers. The first images of the corona in the forbidden lines of Fe IX and Ni XV, showed that there was very little coronal plasma at temperatures below 5 X 10(exp 5) K and above 2.5X 10(exp 6) K. The data also enabled temperature differentiations as low as 0:2 X 10(exp 6) K in different density structures. These observations showed how the passage of CMEs through the corona, prior to totality, produced large scale ripples and very sharp streaks, which could be identified with distinct temperatures for the first time. The ripples were most prominent in emission from spectral lines associated with temperatures around 10(exp 6) K. The most prominent streak was associated with a conical-shaped void in the emission from the coolest line of Fe IX and from the hottest line of Ni XV. A prominence, which erupted prior to totality, appeared in the shape of a hook in the cooler lines of Fe X and Fe XI, spanning 0.5 R(solar) in extent starting at a heliocentric distance of 1.3 R(solar), with a complex trail of hot and cool twisted structures connecting it to the solar surface. Simultaneous Fe X 17.4 nm observations from space by Proba2/SWAP provided an ideal opportunity for comparing emission from a coronal forbidden line, namely Fe X 637.4 nm, with a space-based EUV allowed line. Comparison of the Fe X 17.4 nm and 637.4 nm emission provided the first textbook example of the role of radiative excitation in extending the detectability of coronal emission to much larger heliocentric distances than its collisionally excited component. These eclipse observations demonstrate the unique capabilities of coronal forbidden lines for exploring the evolution of the coronal magnetic field in the heliocentric distance range of 1 - 3 R(solar), which is currently inaccessible to any space-borne or ground-based observatory.

Habbal, Shadia Rifai↗