Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electrode”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

The aluminum electrode in AlCl3-alkali-halide melts

Passivation phenomena were observed upon cathodic and anodic polarization of the Al electrode in AlCl3-KCl-NaCl melts between 100 and 160 C. They are caused by formation of a solid salt layer at the electrode surface resulting from concentration changes upon current flow. The anodic limiting currents increased with temperature and with decreasing AlCl3 content of the melt. Current voltage curves obtained on a rotating aluminum disk showed a linear relationship between the anodic limiting current and 1/sq root of 2 pi (rps). Upon cathodic polarization dentrite formation occurs at the Al electrode. The activation overvoltage in AlCl3-KCl-NaCl (57.5-12.5-20 mol%) was determined by galvanostatic current step methods. An apparent exchange current density of 270 mA/cm2 at 130 C and a double layer capacity of 40 plus or minus 10 microfarad/cm2 were measured.

Holleck, G. L.↗

Research on rechargeable oxygen electrodes.

A research program is described which consisted of studying the effects of electrode cycling in very pure KOH solutions, with and without controlled additions of impurities, on oxide formation, oxygen evolution kinetics, oxygen reduction kinetics (including hydrogen peroxide formation), and changes in electrode structure. Bright platinum, platinized platinum, and Teflon-bonded platinum black electrodes were studied. Three main problem areas are identified: the buildup of a refractory anodic layer on prolonged cycling, which leads to a degradation of performance; the dissolution and subsequent deposition of dendritic platinum in the separator, leading to short-circuit ing and loss of electrocatalyst; and the disruptive effect of bubbling during gas evolution on charge. Each of these problem areas is analyzed, and remedial solutions are proposed.

Giner, J.↗

The aluminum electrode in AlCl3-alkali-halide melts.

Passivation phenomena have been observed upon cathodic and anodic polarization of the Al electrode in AlCl3-KCl-NaCl melts between 100 and 160 C. They are caused by formation of a solid salt layer at the electrode surface resulting from concentration changes upon current flow. The anodic limiting currents increased with temperature and with decreasing AlCl3 content of the melt. Current voltage curves obtained on a rotating aluminum disk showed a linear relationship between the anodic limiting current and omega to the minus 1/2 power. Upon cathodic polarization, dendrite formation occurs at the Al electrode. The activation overvoltage in AlCl3-KCl-NaCl was determined by galvanostatic current step methods. An apparent exchange current density of 270 mA/sq cm at 130 C and a double layer capacity of 40 plus or minus 10 microfarad/sq cm were measured.

Holleck, G. L.↗

Insulated ECG electrodes

Insulated, capacitively coupled electrode does not require electrolyte paste for attachment. Other features of electrode include wide range of nontoxic material that may be employed for dielectric because of sputtering technique used. Also, electrode size is reduced because there is no need for external compensating networks with FET operational amplifier.

Portnoy, W. M.↗

High-efficiency, low-temperature cesium diodes with lanthanum-hexaboride electrodes

Lanthanum hexaboride electrodes in 1700 K cesium diodes may triple power outputs compared with those demonstrated for nuclear thermionic space applications. Still greater relative gains seem possible for emitters below 1700 K. Further improvements in cesium diode performance should result from the lower collector temperatures allowed for earth and low power space duties. Decreased temperatures will lessen thermal transport losses that attend thermionic conversion mechanisms. Such advantages will add to those from collector Carnot and electrode effects. If plasma ignition difficulties impede diode temperature reductions, recycling small fractions of the output power could provide ionization. So high efficiency, low temperature cesium diodes with lanthanum hexaboride electrodes appear feasible.

Morris, J. F.↗

High-efficiency, low-temperature cesium diodes with lanthanum-hexaboride electrodes

Lanthanum-hexaboride electrodes in 1700 K cesium diodes may triple power outputs compared with those demonstrated for nuclear thermionic space applications. Still greater relative gains seem possible for emitters below 1700 K. Further improvements in cesium-diode performance should result from the lower collector temperatures allowed for earth and low-power-space duties. Decreased temperatures will lessen thermal-transport losses that attend thermionic-conversion mechanisms. Such advantages will add to those from collector-Carnot and electrode effects. If plasma ignition difficulties impede diode temperature reductions, recycling small fractions of the output power could provide ionization. So high-efficiency, low-temperature cesium diodes with lanthanum-hexaboride electrodes appear feasible.

Morris, J. F.↗

A three-electrode streamer chamber

A three electrode streamer chamber has been designed with basic components consisting of two glass boxes with overall dimensions 1.00 x 500 x 200 cu m filled with neon at 1 atm. Serving as a high voltage pulse source is a nanosecond voltage pulse generator with cutoff discharges at 16 atm nitrogen pressure. The discharges are designed for obtaining an adjustable pulse with an amplitude of 600 kV and a nanosecond pump. To match the chamber electrodes with the oscillator, the electrodes are manufactured in the shape of a three-wire strip line. The cutoff discharger plug-in and the operating instructions are also described here.

Nurgozhin, N. N.↗

Insulated electrocardiographic electrodes

An integrated system is disclosed including an insulated electrode and an impedance transformer which can be assembled in a small plastic housing and used for the acquisition of electrocardiographic data. The electrode may be employed without a paste electrolyte and may be attached to the body for extended usage without producing skin reaction. The electrode comprises a thin layer of suitable nontoxic dielectric material preferably deposited by radio frequency sputtering onto a conductive substrate. The impedance transformer preferably comprises an operational amplifier having an FET input stage connected in the unity gain configuration which provides a very low lower cut-off frequency, a high input impedance with a very small input bias current, a low output impedance, and a high signal-to-noise ratio.

David, R. M.↗

Clearance of short circuited ion optics electrodes by capacitive discharge

The ion optics electrodes of low specific impulse (3000 sec) mercury electron bombardment ion thrusters are vulnerable to short circuits by virtue of their relatively small interelectrode spacing (0.5 mm). Metallic flakes from backsputtered deposits are the most probable cause of such 'shorts' and 'typical' flakes have been simulated here using refractory wire that has a representative, but controllable, cross section. Shorting wires can be removed by capacitive discharge without significant damage to the electrodes. This paper describes an evaluation of 'short' removal versus electrode damage for several combinations of capacitor voltage, stored energy, and short circuit conditions.

Poeschel, R. L.↗

An electrode system for tetrapolar electrical impedance plethysmography of the finger

A rigid band electrode system is described which facilitates location of the recording electrodes of a tetrapolar impedance plethysmograph used for measuring pulsations of blood in a finger segment. The electrodes can be relocated accurately, and the volume of the finger segment under study can be precisely defined. The new system ensures good electrical contact and minimizes movement artifacts in the plethysmograph trace by holding the finger segment in a firm position.

Montgomery, L. D.↗

Testing EKG electrodes on-line

Simple test instrument allows electrocardiograph operator to check individual electrodes while they are attached to subject. Simply by rotating switch and observing meter, operator verifies that each electrode is not short-circuited or open-circuited and does not present excessive contact resistance at its interface with skin. Instrument also makes it convenient to check electrode cables that are subject to frequent bending and wear, such as cables used on patients who are exercising.

Crosier, W. G.↗

Investigation of effects of temperature, salinity, and electrode design on the performance of an electrochemical coliform detector

The results of two research programs to determine the optimum detector design for measuring fecal coliforms in saline waters for operational systems are presented. One program was concerned with the effects of temperature and salinity on endpoint response time, and the other, the interaction between electrode configurations and the test organisms. Test results show that the endpoint response time is related to salinity and seawater temperature; however, these results can be minimized by the correct choice of growth media. Electrode configurations were developed from stainless steel, Parlodion-coated stainless steel, and platinum that circumvented problems associated with the commercial redox electrodes.

Grana, D. C.↗

Aerospace electrode line

A facility which produces electrodes for spacecraft power supplies is described. The electrode assembly procedures are discussed. A number of design features in the production process are reported including a batch operation mode and an independent equipment module design approach for transfering the electrode materials from process tank to process tank.

Miller, L.↗

Pocket ECG electrode

A low noise electrode suited for sensing electrocardiograms when chronically and subcutaneously implanted in a free ranging subject is described. The electrode comprises a pocket shaped electrically conductive member with a single entrance adapted to receive body fluids. The exterior of the member and the entrance region is coated with electrical insulation so that the only electrolyte/electrode interface is within the member, remote from artifact-generating tissue. Cloth straps are bonded to the member to permit the electrode to be sutured to tissue and to provide electrical lead flexure relief.

Lund, G. F.↗

Optimal thermionic energy conversion with established electrodes for high-temperature topping and process heating

Applied research-and-technology (ART) work reveals that optimal thermionic energy conversion (TEC) with approximately 1000 K to approximately 1100 K collectors is possible using well established tungsten electrodes. Such TEC with 1800 K emitters could approach 26.6% efficiency at 27.4 W/sq cm with approximately 1000 K collectors and 21.7% at 22.6 W/sq cm with approximately 1100 K collectors. These performances require 1.5 and 1.7 eV collector work functions (not the 1 eV ultimate) with nearly negligible interelectrode losses. Such collectors correspond to tungsten electrode systems in approximately 0.9 to approximately 6 torr cesium pressures with 1600 K to 1900 K emitters. Because higher heat-rejection temperatures for TEC allow greater collector work functions, interelectrode loss reduction becomes an increasingly important target for applications aimed at elevated temperatures. Studies of intragap modifications and new electrodes that will allow better electron emission and collection with lower cesium pressures are among the TEC-ART approaches to reduced interelectrode losses. These solutions will provide very effective TEC to serve directly in coal-combustion products for high-temperature topping and process heating. In turn this will help to use coal and to use it well.

Morris, J. F.↗

The structures of the sintered plaque in the nickel hydroxide electrode

The various failure mechanisms were identified for the nickel electrode. The nickel sinter is involved in all these failure modes. The first one, chemical attack by carbonate, nitrate or other electrolyte components, involves corrosion of the nickel sinters. The second is the physical mode, which involves swelling of the electrode and physical shifting of the sinter in the electrodes. The third is the mechanical failure mode, and is due to fatigue or to the oxygen pressure that causes deformation or fracture of the sinter.

Vyas, B.↗

Lightweight composite cadmium electrodes

The design and fabrication of the electrodes are discussed. The electrode efficiency of different impregnations of plaques is reported. The chemical impregnation for commercial use has the lowest efficiency, and for aerospace application it has higher efficiency. The electrochemically impregnated electrode is the most efficient.

Sutula, R. A.↗

Chemical and morphological characteristics of lithium electrode surfaces

Lithium electrode surfaces were analyzed for chemical and morphological characteristics, using electron spectroscopy chemical analysis (ESCA) and scanning electron microscopy (SEM). Samples included lithium metal and lithium electrodes which were cycled in a 1.5 M lithium arsenic hexafluoride/two-methyl tetrahydrofuran electrolyte. Results show that the surface of the as-received lithium metal was already covered by a film composed of LiO2 and an Li2O/CO2 adduct with a thickness of approximately 100-200 A. No evidence of Ni3 was found. Upon exposure of the lithium electrode to a 1.5 M LiAsF6/2-Me-THF electrochemical environment, a second film was observed to form on the surface, consisting primarily of As, Si, and F, possibly in the form of lithium arsenic oxyfluorides or lithium fluorosilicates. It is suggested that the film formation may be attributed to salt degradation.

Yen, S. P. S.↗