Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electricity demand”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

South Africa: Framework for Energy Efficiency Demand Side Management

In July 2022, President Cyril Ramaphosa announced an emergency response plan to address the growing electricity crisis in South Africa, which included the necessity for customers of Eskom, South Africa’s primary electricity supplier, to implement demand-side energy efficiency measures. This report is the second of two reports that provides the foundation for a strategic Demand-Side Management (DSM) approach to reduce load shedding and maximize energy savings in South Africa, though inter-governmental collaboration and increased coordination of energy efficiency activities. The first report focuses on the experience of Eskom’s rate-funded Integrated Demand Management (IDM) programme, from its beginning in 2004 to today, highlighting the factors that led to failed support for the programme. This second report focuses on addressing the challenges identified in the first report and describes the elements of a policy framework to develop a sustained DSM program to meet the government’s energy efficiency goals in terms of greenhouse gas emissions reduction and social equity and inclusion to achieve a just transition.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impact of Geothermal District Heating System on Flexibility of Microgrid in Tuttle, Oklahoma: Preprint

Flexibility is the capability of the power grid to maintain a balance between electricity generation and variable demand. This study presents preliminary results evaluating the impact of geothermal district heating systems on the flexibility of a conceptual microgrid in Tuttle, Oklahoma. Heating demand profiles were modeled using EnergyPlus for the district that includes two schools and 250 single-family houses. Then, geothermal energy production was modeled using GEOPHIRES to estimate how much heating demand in the district can be supplied by five different geothermal system scenarios. The results indicated that geothermal energy production varied depending on the resource temperature at different depths, system configurations, and flow rates. For the grid flexibility analysis, electricity consumptions in the five geothermal systems were estimated for pump operations to circulate water from the wells to radiators, while electricity consumption by air-source heat pump in the base case was estimated to supply the same heating load. Electricity consumption in the geothermal systems was significantly lower than those in base cases. The electricity saved by the geothermal system was then incorporated into the microgrid electrical load profiles where variable renewable electricity generation is significantly high. The results visually showed that geothermal district heating system can improve grid flexibility as a baseload during the winter season. The results also highlighted potential opportunities to save energy costs that will be further analyzed in future study.

Cambium↗

Impact of Geothermal District Heating System on Flexibility of Microgrid in Tuttle, Oklahoma

Flexibility is the capability of the power grid to maintain a balance between electricity generation and variable demand. This study presents preliminary results evaluating the impact of geothermal district heating systems on the flexibility of microgrid in Tuttle, Oklahoma. Heating demand profiles were modeled using EnergyPlus for the district that includes two schools and 250 single-family houses. Then, geothermal energy production was modeled using GEOPHIRES to estimate how much heating demand in the district can be supplied by five different geothermal system scenarios. The results indicated that geothermal energy production varied depending on the resource temperature at different depths, system configurations, and flow rates. For the grid flexibility analysis, electricity consumptions in the five geothermal systems were estimated for pump operations to circulate water from the wells to radiators, while electricity consumption by air-source heat pump in the base case was estimated to supply the same heating load. Electricity consumption in the geothermal systems was significantly lower than those in base cases. The electricity saved by the geothermal system was then incorporated into the microgrid electrical load profiles where variable renewable electricity generation is significantly high. The results visually showed that geothermal district heating system can improve grid flexibility as a baseload during the winter season. The results also highlighted potential opportunities to save energy costs that will be further analyzed in future study.

Cambium↗

Hierarchical thermal-conductive polymer nanocomposites for thermal management

Managing heat in electrical conductors is a major challenge to meet the demands for sustainable energy use and electrical reliability, most notably power electronics and energy-critical electrical machines. Achieving such disparate functionalities, such as high temperature thermal and electrical reliability, require rational design and manufacturing of thermal conductor material and its hierarchical structures. Here we present hierarchical thermal-conductive nanocomposites, consisting of nanostructured ceramic conformal coating and aligned ultrahigh molecular weight polyethylene fiber, to tailor heat dissipation in electric conductors. The hybrid aligned thermal interface exhibits a highly desirable temperature dependent anisotropic high thermal conductivity with 0.98W m –1 K –1 and dielectric strength with 3.4. In addition, electrically insulating thermal interfaces demonstrate high-performing and reliable electrical systems under the dynamic load conditions. The surface temperature of heterogeneous ceramic-polymer encapsulated conductor is 17.8 °C lower than that of polymer-encapsulated conductor at the same electrical load. Consequently, the findings shown here hold great promises for directing heat extraction in electrical machine systems, advancing thermal management for emerging electronic applications.

36 MATERIALS SCIENCE↗

OCHRE: The Object-oriented, Controllable, High-resolution Residential Energy Model for Dynamic Integration Studies

Electrification and the growth of distributed energy resources (DERs), including flexible loads, are changing the energy landscape of electric distribution systems and creating new challenges and opportunities for electric utilities. Changes in demand profiles require improvements in distribution system load models, which have not historically accounted for device controllability or impacts on customer comfort. Although building modeling research has focused on these features, there is a need to incorporate them into distribution load models that include DERs and can be used to study grid-interactive buildings. In this paper, we present the Object-oriented, Controllable, High-resolution Residential Energy (OCHRE) model. OCHRE is a controllable thermal-electric residential energy model that captures building thermal dynamics, integrates grid-dependent electrical behavior, contains models for common DERs and end-use loads, and simulates at a time resolution down to 1 minute. It includes models for space heaters, air conditioners, water heaters, electric vehicles, photovoltaics, and batteries that are externally controllable and integrated in a co-simulation framework. Using a proposed zero energy ready community in Colorado, we co-simulate a distribution grid and 498 all-electric homes with a diverse set of efficiency levels and equipment properties. We show that controllable devices can reduce peak demand within a neighborhood by up to 73% during a critical peak period without sacrificing occupant comfort. We also demonstrate the importance of modeling load diversity at a high time resolution when quantifying power and voltage fluctuations across a distribution system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electrification Analysis: Container Ports' Cargo Handling Equipment

This one-page highlight details the key takeaways from a project that utilized NREL's Fleet Research, Energy Data, and Insights (FleetREDI) data analysis pipeline, the Electrification Analysis of Container Ports' Cargo Handling Equipment project. This project created a scalable solution to model energy demand per shipping container moved (kWh/TEU) for an all-electric cargo handling equipment fleet located at a maritime port. The model allows stakeholders to understand energy demand at each electric vehicle (EV) equipment level and is easily scalable to container demand and EV adoption rate projections.

ADVANCED PROPULSION SYSTEMS↗

Fifty years of lithium-ion batteries and what is next?

Here, the first rechargeable lithium batteries were built 50 years ago, at the same time as the Materials Research Society was formed. Great strides have been made since then taking a dream to domination of portable energy storage. During the past two decades, the demand for the storage of electrical energy has mushroomed both for portable applications such as for the iPhone and electric vehicles and for more than 1 GWh grid applications. As storage and power demands have increased, the batteries have evolved with their chemistries being pushed to the limits. This has resulted in the energy densities almost doubling and the cost dropping by more than an order of magnitude. However, the present electrochemical systems are still too costly to penetrate major new markets, still higher performance is required, and environmentally acceptable and sustainable materials are required.

25 ENERGY STORAGE↗

Optimization of an Air Core Dual Halbach Array Axial Flux Rim Drive for Electric Aircraft

The anticipated development of the on-demand-mobility (ODM) market has accelerated the development of electric aircraft. Most proposed electric aircraft have propulsion systems that consist of fans directly driven by electric motors. The lower complexity of these propulsion systems opens the door to more custom propulsion system designs that are tailored to a given aircraft and its mission. This paper represents initial steps in the development of an electric propulsion system design code. A proof of concept version of the code is presented. The proof of concept version of the code is for the design of an axial flux rim driven propulsion system. NASA's all electric aircraft X-57, is used as a case study for this design code. The results of this case study are used to discuss the feasibility and potential benefits of using an axial flux rim driven propulsor on X-57. The final result of the case study shows a potential 4km increase in range over the current design.

Tallerico,Thomas F.↗

Levelized Cost of Charging Electric Vehicles

This data set includes the levelized cost of charging (LCOC) and lifetime fuel cost savings (LFCS) values as reported in "Levelized Cost of Charging of Electric Vehicles in the United States." Values are reported at the state and national levels for battery electric vehicles (BEVs) and plug-in hybrid electric vehicles (PHEVs). The data set also includes the four annual direct current fast charging (DCFC) station load profiles used to approximate the levelized cost of DCFC charging. Each profile provides 15-min resolved power requirements for one full year. Borlaug, B., Salisbury, S., Gerdes, M., and Muratori, M., Levelized Cost of Charging Electric Vehicles in the United States, Joule (2020), https://doi.org/10.1016/j.joule.2020.05.013.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Future material demand for automotive lithium-based batteries

The world is shifting to electric vehicles to mitigate climate change. Here, we quantify the future demand for key battery materials, considering potential electric vehicle fleet and battery chemistry developments as well as second-use and recycling of electric vehicle batteries. We find that in a lithium nickel cobalt manganese oxide dominated battery scenario, demand is estimated to increase by factors of 18–20 for lithium, 17–19 for cobalt, 28–31 for nickel, and 15–20 for most other materials from 2020 to 2050, requiring a drastic expansion of lithium, cobalt, and nickel supply chains and likely additional resource discovery. However, uncertainties are large. Key factors are the development of the electric vehicles fleet and battery capacity requirements per vehicle. If other battery chemistries were used at large scale, e.g. lithium iron phosphate or novel lithium-sulphur or lithium-air batteries, the demand for cobalt and nickel would be substantially smaller. Closed-loop recycling plays a minor, but increasingly important role for reducing primary material demand until 2050, however, advances in recycling are necessary to economically recover battery-grade materials from end-of-life batteries. Second-use of electric vehicles batteries further delays recycling potentials.

25 ENERGY STORAGE↗

South Africa: Energy Efficiency Demand Side Management Experience (2004-2022)

In July 2022, President Cyril Ramaphosa announced an emergency response plan to address the growing electricity crisis in South Africa, which included the necessity for customers of Eskom, South Africa’s primary electricity supplier, to implement demand-side energy efficiency measures. This report is the first of two reports that provides the foundation for a strategic Demand-Side Management (DSM) approach to reduce load shedding and maximize energy savings in South Africa, through inter-governmental collaboration and increased coordination of energy efficiency activities. This first report focuses on the experience of Eskom’s rate-funded Integrated Demand Management (IDM) programme, from its beginning in 2004 to today, highlighting the factors that led to failed support for the programme, and emphasizing the measures that will need to be addressed to meet the government’s energy efficiency (EE) goals, as well as other socio-economic and environmental priorities, such as job creation, affordability and greenhouse gas (GHG) emission reduction goals.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Aggregate residential demand flexibility behavior: A novel assessment framework

Residential demand flexibility (DF) could save the U.S. electric grid up to 10 GW of peak demand while supporting increased amounts of renewable generation. However, less than 40% of the estimated DF peak reduction capacity is currently realized, and less than 8% of American households are enrolled. These low participation rates are combined with high rates of "overriding" a DF event and eventual opt-outs among enrolled customers. There is still not a comprehensive understanding of the drivers of DF participation and occupant interaction with DF program signals. We, therefore, present a novel survey processing framework to assess occupant DF-relevant behavior from the American Time Use Survey (ATUS). Using the framework, we summarize both the extensive and intensive behavior of more than 200,000 ATUS respondents (2003-2018 data) and provide insights on the DF-relevant behavior of residential occupants, which is generally overlooked in the literature. Here we use the framework to identify the activity priorities of residential occupants in the United States during different DF-relevant periods (critical peak, peak, and off-peak). These preferred activities capture overlooked routine behaviors that could be barriers to DF participation, if ignored, and might explain the high levels of overrides often exhibited by participants of demand response.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

IM3 Data Center Driven Grid Stress Dataset for the U.S. Western Interconnection

This dataset provides projected grid stress and reliability results (including all model inputs and outputs from an open-source grid operations modeling framework - GO), for the Integrated Multisector, Multiscale Modeling (IM3) project, under varying levels of data center demand growth between 2025 and 2035 in the U.S. Western Interconnection. The scenarios and sensitivity experiments are combinations of different data center demand growth rates and energy, weather, population and economic pathways. Data center demand growth projections were sourced from the Electric Power Research Institute (EPRI). The data center demand growth projection names are: Low (3.71% annual data center demand growth) Moderate (5% annual data center demand growth) High (10% annual data center demand growth) Higher (15% annual data center demand growth) Energy, weather, population and economic pathways are informed by two Shared Socioeconomic Pathways (SSP3 and SSP5) and two Representative Concentration Pathways (RCP4.5 and RCP8.5) following the hotter general circulation model (GCM) forcing group from a set of perturbed thermodynamics simulations. The resulting pathway names are: rcp45hotter_ssp3 rcp45hotter_ssp5 rcp85hotter_ssp3 rcp85hotter_ssp5 The main scenarios and sensitivity experiments are detailed below. Reference scenario: The projected grid stress and reliability results for the U.S. Western Interconnection from a previous study. This scenario does not consider data center demand growth explicitly. Data center scenario: Building on the reference scenario, this scenario considers various data center growth rates and how they impact the U.S. Western Interconnection. Data center loads are modeled as flat 8760-hr profiles. This scenario does not consider new generation and transmission capacities specifically designed to meet the new data center demands. The related folder is named "flat". Delayed generator retirements sensitivity experiment: Building on the data center scenario, this experiment explores the impact of different levels of natural gas and nuclear generator retirement delays. The resulting scenario names are: (1) postponing 100% nuclear retirements; (2) postponing 100% nuclear and 25% natural gas retirements; (3) postponing only 50% natural gas retirements; (4) postponing 100% nuclear and 50% natural gas retirements; (5) postponing 100% nuclear and 75% natural gas retirements; and (6) postponing 100% nuclear and 100% natural gas retirements. The related folder names are: no_gen_retire_0_gas, no_gen_retire_25_gas, no_gen_retire_50_gas, no_gen_retire_50_gas_only, no_gen_retire_75_gas, and no_gen_retire_100_gas. Demand response through curtailment sensitivity experiment: Building on the data center scenario, this experiment explores the impact of different participation and compensation levels of data center demand response. The resulting scenario names are: (1) 5% demand available for curtailment with 750 $/MWh compensation; (2) 5% demand available for curtailment with 500 $/MWh compensation; (3) 5% demand available for curtailment with 250 $/MWh compensation; (4) 15% demand available for curtailment with 750 $/MWh compensation; (5) 15% demand available for curtailment with 500 $/MWh compensation; and (6) 15% demand available for curtailment with 250 $/MWh compensation. The related folder names are: dr_cost_250_drup_0_drdown_5, dr_cost_250_drup_0_drdown_15, dr_cost_500_drup_0_drdown_5, dr_cost_500_drup_0_drdown_15, dr_cost_750_drup_0_drdown_5, and dr_cost_750_drup_0_drdown_15. Combination of delayed generator retirements and demand response through curtailment sensitivity experiment: The impact of combining postponing 100% nuclear and 25% natural gas retirements with 5% demand available for curtailment with 750 $/MWh compensation is simulated. The related folder is named "dr_cost_750_drup_0_drdown_5_nuc_100_gas_25". Please refer to the README file for a detailed description of the dataset including individual files and references.

Artificial Intelligence↗

Memory Metals

Under contract to NASA during preparations for the space station, Memry Technologies Inc. investigated shape memory effect (SME). SME is a characteristic of certain metal alloys that can change shape in response to temperature variations. In the late 1980s and early 1990s, Memry used its NASA-acquired expertise to produce a line of home and industrial safety products, and refined the technology in the mid-1990s. Among the new products they developed are three MemrySafe units which prevent scalding from faucets. Each system contains a small valve that reacts to temperature, not pressure. When the water reaches dangerous temperatures, the unit reduces the flow to a trickle; when the scalding temperature subsides, the unit restores normal flow. Other products are the FIRECHEK 2 and 4, heat-activated shutoff valves for industrial process lines, which sense excessive heat and cut off pneumatic pressure. The newest of these products is Memry's Demand Management Water Heater which shifts the electricity requirement from peak to off-peak demands, conserving energy and money.

Source record↗

Development and Testing of an Advanced Cascaded Thermoelectric Residential Heat Pump

Electricity-driven heat pumps using vapor compression cycle are an energy-efficient solution to replace fossil fuel burning and reduce greenhouse gas emissions for space heating in residential buildings. However, heating capacity and Coefficient of Performance (COP) of heat pumps degrade significantly with increasing temperature difference between ambient and indoor environments. Residents and building owners are hence reluctant to fully embrace electric heat pumps. The use of conventional all-electric heat pumps also causes concern for electric utilities due to an increased winter peak demand arising from the use of supplemental electric resistance heaters. Our research is an attempt to alleviate these concerns by designing and laboratory testing a thermoelectric (TE) heat pump cascaded with a vapor compression cycle to enhance heating capacity and COP. TE modules increase the subcooling in the refrigerant liquid of the vapor compression cycle to enlarge the evaporating capacity and works at an efficiency greater than a conventional electric resistance strip. This results in a simple, affordable, efficient and highly controllable solution to adequately meet space heating needs in dwellings. The laboratory testing of the 3-stage cascaded TE heat pump performed in this research has exhibited a higher heating capacity by above 15%, while maintaining a heating COP of 2.0-3.6 in the ambient temperature range of -18˚C to 8˚C (0˚F to 47 ˚F), which represents more than 60% of winter temperatures observed in US. If successfully commercialized, this technology can advance space-heating electrification by overcoming consumer cost barrier of heat pumps.

Shen, Bo↗