Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electrical resistivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

End-Use Savings Shapes Measure Documentation: Variable Refrigerant Flow With 25% Upsizing Allowance for Heating

This documentation focuses on a single end-use savings shape upgrade - a variable refrigerant flow with heat recovery (VRF HR) heating and cooling system coupled with a dedicated outdoor air system (DOAS) for ventilation and where 25% upsizing (or 125% of the original size) is allowed for heating in colder climates (i.e., heating dominant regions). This document will primarily discuss the additional changes to the sizing algorithm and modeling approach, while a comprehensive overview of the fundamental modeling methodology and background of the VRF HR DOAS upgrade, including applicability and other key assumptions can be found in the original documentation: Variable Refrigerant Flow with Heat Recovery and Dedicated Outdoor Air System. To provide more context on the 25% upsizing algorithm, if the building is a cooling dominant (e.g., design cooling load higher than design heating load ), then the outdoor unit capacity of the VRF heat pump is sized based on the design cooling load. However, if the building is heating dominant, then this building is a candidate for the 25% upsizing allowance. Once the 25% upsizing is allowed, if the 25% upsized capacity (or 125% from the original size) represented with design condition exceeds the design heating load, then the design heating load is used for calculating the rated capacity of the outdoor unit. And if the 25% upsized capacity represented with the design condition does not exceed the design heating load, then the 25% upsized capacity represented with rated condition is used for the capacity of the outdoor unit while the remaining heating load is handled with the supplemental/backup electric resistance coil.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High-Efficiency Thermoelectric Clothes Dryer (CRADA Final Report)

A typical clothes dryer in the US accounts for 7% of the average residential customer’s electric bill. Nationwide, consumers pay about $\$$9 billion annually for clothes drying. While energy efficiency for most household appliances has improved by a factor of 2 or more in recent decades, today’s clothes dryers perform similarly to units from the 1970s. Dryer efficiency is measured by the combined energy factor (CEF), with today’s units typically drying 3.73 lb of cloth per kWh consumed. An ENERGY STAR qualified unit must achieve 3.93 lb/kWh (for standard size electric units) and dry in less than 80 minutes. ORNL and CRADA partner Samsung Electronics America have developed an efficient prototype clothes dryer that uses thermoelectric heat pumps instead of electric resistance to dry the clothes. The prototype fabricated at ORNL successfully demonstrated in the laboratory a CEF of 6.89 lb/kWh at standard conditions of 75°F and 50% Relative Humidity (RH), exceeding the original project target of 6.0 lb/kWh. Additional trials on the same prototype achieved faster dry time with slightly lower CEF, meeting all requirements for ENERGY STAR product qualification. Deploying dryers with energy factor of 6 nationwide represents a technical potential of 234 TBtu/yr primary energy savings. The modeling and prototype development activities for the thermoelectric clothes dryer under this CRADA are summarized in this final report.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Blue Canyon Dome: Development of a Small-Scale Testbed for Monitoring Underground Explosions

This report documents the development of the Blue Canyon Dome (BCD) testbed, including test site selection, development, instrumentation, and logistical considerations. The BCD testbed was designed for small-scale explosive tests (~5 kg TNT equivalence maximum) for the purpose of comparing diagnostic signals from different types of explosives, the assumption being that different chemical explosives would generate different signatures on geophysical and other monitoring tools. The BCD testbed is located at the Energetic Materials Research and Testing Center near Socorro, New Mexico. Instrumentation includes an electrical resistivity tomography array, geophones, distributed acoustic sensing, gas samplers, distributed temperature sensing, pressure transducers, and high-speed cameras. This SAND report is a reference for BCD testbed development that can be cited in future publications.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

End-Use Savings Shapes Measure Documentation: Heat Pump Rooftop Units

The heat pump rooftop units (RTUs) measure replaces gas furnace and electric resistance RTUs with high-efficiency heat pump rooftop units (HP-RTUs). The HP-RTUs are intended to be top-of-the line, including high-efficiency fans and heat pump systems. The fans are variable speed, allowing the HP-RTUs to operate as single-zone variable air volume systems. The heat pumps are also variable speed, allowing for high part load performance. All schedules in the existing RTUs are transferred to the new HP-RTUs for consistency. Furthermore, any energy efficiency features in the existing baseline RTUs such as energy recovery or economizers are also transferred to the new HP-RTUs for consistency. This measure is applicable to approximately 45% of the ComStock floor area. The HP-RTU measure demonstrates 10.3% total site energy savings (449 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization of Nitrate, Nitrite, Ammonia, and Tritium in D0220 Cores

This report describes characterization of nitrogen species (nitrate, nitrite, ammonia) in aqueous and solid phases in cores taken in borehole D0220 (well 299-E25-245) under crib 216-A-37-1 at the Hanford Site in 2022 to evaluate (a) the types of nitrogen species currently in the vadose zone and (b) the migration of nitrogen species in the vadose zone. Ammonia and tritium from PUREX decladding condensate were sporadically discharged to the crib from 1977 to 1989. During discharge operations, the estimated travel time through the vadose zone to groundwater was 2.5 to 9 months. By 2003, a characterization borehole (C4106) showed residual pore water with elevated tritium and nitrate in the first 100 ft of the vadose zone, which is likely from the crib. However, there was significantly more nitrate present at the shallowest depth (15 to 22 ft), which may indicate a different source for nitrate, such as adsorbed ammonia slowly being oxidized or nitrogen species precipitates slowly dissolving. In this study, more extensive nitrogen species characterization was done on D0220 cores (drilled in 2022) at 40- and 262-ft depths, which included (a) aqueous nitrate, nitrite, and tritium; (b) adsorbed ammonia; (c) nitrogen in carbonates (or other minerals dissolved in acidic acid); (d) nitrogen in iron oxides (or other minerals dissolved in oxalic acid); and (e) nitrogen in hard-to-extract minerals (minerals dissolved in nitric acid). High pore water nitrate (226 to 331 mg/L) at 40-ft depth measured in D0220 (2022) compared to 60 mg/L at 40-ft depth in C4106 (2003) may indicate nitrate is migrating deeper. Tritium concentrations (pore water 132,000 to 148,000 pCi/L) measured in D0220 at 40-ft depth in 2022 were considerably higher than in C4106 at 40-ft depth (160 pCi/L). Additional nitrogen species mass was present in adsorbed and precipitated phases in D0220 cores. Low adsorbed ammonia was measured at 40.1- and 261.7-ft depths. Low concentrations of carbonate associated nitrogen and iron oxide-associated nitrogen were present at 40.1 and 40.6 ft depths. Nitrogen species in solid phase extractions indicate nitrogen precipitates or aqueous nitrate or ammonia trapped in sediment microfractures that are coated by precipitates. Overall, the nitrogen species and tritium characterization at two depths in D0220 showed that additional nitrogen species were present in the vadose zone. In addition, elevated pore water nitrate in D0220 at 40 ft depth from 2022 may indicate vertical migration compared to C4106 nitrate profile from 2003. Analysis of additional depths in D0220 and spatial variability of the nitrate plume along the length of the crib (from surface electrical resistivity) would be extremely useful for this comparison.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Theory of Novel Superconductors (Final Technical Report)

This Final Technical Report gives the results of a series of problems related to the origin of superconductivity, the quantum mechanical state of matter where electrical resistance vanishes, in several classes of new materials where the conventional mechanism that binds electrons into pairs based on the electron-phonon interaction apparently fails. In several families of quantum materials including cuprates, iron-based superconductors, and heavy fermion materials, it is believed that the repulsive Coulomb interaction between electrons can create effective attractive interactions, generally in higher pair momentum channels. These "unconventional" superconductors include materials with the highest critical temperatures at ambient pressure known, so it is imperative to understand how superconductivity arises to guide the search for materials that superconduct at or near room temperature, which would have enormous technological impact. A second objective has been to construct a theory that can quantitatively explain the properties of existing materials, based on information from first-principles electronic structure calculations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Topological Surface and Bulk States in Dirac Semimetal Alpha-Sn Thin Films

Supported by this DOE grant, we made significant advancements in the study and application of topological surface states (TSS) in topological Dirac semimetal (TDS) α-Sn thin films. Our key findings include: (1) the successful growth of TDS α-Sn thin films via sputtering, an industry-friendly technique, on Si and InSb substrates, marking a breakthrough over previous molecular beam epitaxy methods, (2) the demonstration of enhanced damping in adjacent NiFe thin films due to the TSS of α-Sn, (3) the first observation of a strong bilinear magneto-electric resistance (BMER) effect in TDS materials at room temperature, with responses surpassing previous results, (4) the identification of quantum oscillations in α-Sn thin films associated with the TSS, revealing critical quantum transport characteristics such as Berry phase and quantum mobility, (5) the first experimental observation of negative magnetoresistance in α-Sn, and (6) the demonstration of spinorbit torque-driven, field-free magnetization switching in an α-Sn/Ag/CoFeB trilayer, achieving efficiency levels higher than conventional heavy-metal-based structures, highlighting the essential role of TSS in enabling the switching process.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Electro-Thermo-Mechanical (ETM) Study on Submarine Dynamic Power Cables (SDPC) for Offshore Wind Transmission

Understanding the failure mechanisms of submarine dynamic power cables (SDPC) is critical for innovative design to meet the 2035 cost reduction target of U.S. DOE Floating Offshore Wind Shot. This is important because the current design suffers a significant failure rate in the field. This project conducted a systematic electro-thermo-mechanical (ETM) experimental study on the power cores extracted from a 15kV power cable with three cores of copper conductor, ethylene propylene rubber (EPR) insulation, and continuously corrugated welded aluminum armor (CCWA). An ETM testing system was developed by integrating a high voltage (HV) amplifier, two ceramic heaters, and a rod-plate transverse compression setup into a mechanical testing machine. Increasing temperature from room temperature (RT, 22 degree C) to 90 degree C resulted in the 67% decrease in the failure mechanical load as defined by the dielectric breakdown. Under creep mechanical loading, the dielectric breakdown time was decreased by 70% for a given mechanical load when the specimen temperature increased from RT to 90oC. The failure strain in both monotonic and creep mechanical loading modes was related to the maximum mechanical load applied. Although the dielectric breakdown occurred in the ETM test, the post-test measurement revealed an impressive recovery of electric resistance. The failure analysis on cross section of tested specimens indicated a sizable gap across insulation layer near the area between copper conductor and loading rod, which apparently resulted from online dielectric failure and offline elastic recovery of components including conductor and insulation layer.

17 WIND ENERGY↗

ComStock Measure Documentation: Heat Pump Rooftop Units with Standard Performance

This documentation focuses on a single end-use savings shape measure - heat pump rooftop units (HP-RTUs) with standard efficiencies that are prevalent in the current market. Today, these products are claimed as standard efficiency by the manufacturers and are most commonly installed. This document will primarily discuss the additional changes of performance and configuration of the standard efficiency HP-RTUs while a comprehensive overview of the fundamental modeling methodology and background of the HP-RTU measure, including applicability, sizing scheme, and other key assumptions can be found in the original documentation: Heat Pump RTU. The definition of "standard efficiency" can be a bit vague when considering detailed specifics other than efficiency metrics of a heat pump. Thus, we have focused on reflecting products where manufacturers claim as standard efficiency and products that are not top-of-the-line in their model lineup. Based on gathering information from eight products from four major manufacturers, there are some common (or relatively prevalent) characteristics and we have defined standard efficiency product as follows: direct drive outdoor unit fan, two stages of heat pump cooling, single stage heat pump heating (i.e., all compressors running at the same time), heat pump minimum lockout temperature of 0°F (-17.8°C), backup electric resistance heating, backup heating runs at the same time as heat pump heating , heat pump heating locking out below minimum operating temperature, IEER in between 11-13, and HSPF in between 8-8.9. There are cases where some of these products have other variations: a variable frequency drive fan, dual fuel (i.e., gas backup heating) option, three or more cooling stages, two stages of heat pump heating, no backup heating as default , etc. However, this work tried to reflect the most common and prevalent options for a standard efficiency product.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermoelectric heat pump water heater priced for mass market deployment with 30% energy savings

This project, a Cooperative Research and Development Agreement (CRADA) partnership between A. O. Smith and Oak Ridge National Laboratory (ORNL), was initiated to develop a heat pump water heater (HPWH) based on thermoelectric (TE) heat pump technology capable of seeing widespread market adoption by having a one-year payback versus electric resistance options.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Laboratory Testing and Performance Characterization of the High Efficiency Dehumidification System (HEDS) Technology

The high efficiency dehumidification system (HEDS) is a unique air handling unit (AHU) design with two water coils. Connected in series, these water coils can sensibly reheat the airstream after it is cooled and dehumidified, thereby mitigating (or sometimes eliminating) the need for conventional sensible reheat with additional energy from hot water, electric resistance or steam coils. Another unique design feature is the size of the HEDS primary cooling coil. While typical AHU cooling coils have a 6-row geometry, the HED's cooling coil has a deeper 10-row geometry enabling discharge air dew point temperatures at or below 55 degrees F despite warmer chilled water supply temperatures approaching (sometimes exceeding) 50 degrees F. The ability to meet acceptable discharge air dew points with warmer chilled water supply temperatures improves both operational efficiency and system resilience against chilled water plant operational or control issues. This report summarizes the 59 steady-state test results that form a comprehensive performance map of the HEDS technology including its reheat capability. The breadth of outdoor air conditions and flow rates over which the HEDS technology was tested and characterized encompasses the unit 1) operating as a dedicated outdoor air system or mixed air system and 2) controlled with constant air volume or variable air volume fan control.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

ComStock Measure Scenario Documentation: Laboratory-Informed Modeling of Standard Performance Heat Pump Rooftop Units

This measure scenario replaces gas and electric resistance RTUs in the U.S. commercial building stock with standard efficiency commercial off the shelf heat pump rooftop units. This study uses performance data informed by NREL laboratory testing of a standard efficiency 7.5-ton heat pump RTU. This is the key distinction between this measure scenario and a similar ComStock measure scenario - Standard Performance Heat Pump Rooftop Units - that uses published manufacturer data tables to inform performance. These two scenarios are compared in this report.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Estimating Vadose Zone Flow Properties at the 100 K-East Soil Flushing Site Using ERT Monitoring Data: 2023 Interim Report - 100 KE Soil Property Estimation

In situ soil flushing is being using at the Hanford 100 K-East (100 KE) area to transport mobile chromium contamination in the vadose zone to the water table, where it can be collected and treat through pump and treat operations. The efficacy of soil flushing is directly related to the volume of clean water that infiltrates through contaminated soils. In practice, it is infeasible to comprehensively monitor which regions of the vadose zone are being infiltrated through direct sampling of pore water. Consequently, there can be significant uncertainty about which regions of the subsurface have been treated, especially if hydrogeologic conditions are favorable for the development of unstable flows and preferred flow pathways through the vadose zone (Jarvis, Koestel, and Larsbo 2016). Current approaches for quantitative monitoring of soil flushing performance rely on contaminant concentration measurements collected from extractions wells. There is no quantitative information on the volume of flush water delivered to targeted regions of the vadose zone at the Hanford Site, leading to significant uncertainty regarding source term removal and long-term impacts to groundwater. If the subsurface hydrogeologic properties at the 100 KE Area were adequately known, qualitative metrics of soil flushing performance could be simulated, thereby negating expenses required to obtain quantitative performance information through borehole drilling/sampling. However, estimating in situ hydrogeologic properties has long proven elusive, due primarily to a lack of sufficient information to constrain heterogeneous property estimates to a useful degree of certainty. Estimating vadose zone hydrogeologic properties is particularly challenging due the dependence of hydraulic conductivity on saturation. This report describes progress toward a first-of-its-kind demonstration using surface time-lapse 3D electrical resistivity tomography (ERT) monitoring data to estimate the hydrogeologic properties that control flush water transport at the 100 KE soil flushing site. The ultimate objective is (1) to verify sufficient information exists in the ERT monitoring data to adequately resolve vadose zone hydraulic properties, and (2) generate a “digital twin” (i.e., a numerical simulator) that can be used to simulate the amount of flush water that has been delivered to each targeted region of the vadose zone, and thereby assess the efficacy of flush water delivery. Resulting performance estimates can be used in leu of comprehensive borehole drilling and direct sampling (or wellbore logging) that would otherwise be required to obtain the same information.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Quench Propagation On Rare-Earth Barium Copper Oxide (REBCO) Tape

Rare Earth Barium Copper Oxide (REBCO) is a high‑temperature superconducting material that has zero electrical resistance. A quench occurs when a section of the superconductor suddenly transitions to a resistive state after exceeding its critical current. This localized loss of superconductivity generates a voltage rise, serving as an essential signal for quench detection and protection. While capable of carrying extremely high currents, REBCO is mechanically brittle and have slow quench propagation which makes voltage change difficult to detect.

Ju, Han [Northwestern U.]↗

Modeling the PV System Level Economic Impact of PV Connector Failure Modes

Photovoltaic (PV) connectors must maintain mechanical integrity for over 25 years while operating under UV exposure, elevated temperature, and mechanical loading. Connector degradation increases with electrical resistance, leading to energy losses, unplanned downtime, and higher operation and maintenance (O&M) costs and in severe cases, safety risks from overhearing or arcing. Connector related failures remain among the most frequent causes of disruption in utility-scale PV (UPV) systems, yet their lifetime economic impacts are poorly quantified. This work presents a techno-economic analysis (TEA) framework that links identified connector failure modes to system level energy losses and lifetime cost impacts using identified resistance measurements and failure rates from 6,2761 PV connectors inspected. Connector failures increase system level O&M costs, raising LCOE by roughly 5%. Downtime driven availability losses dominate economic impact. Resistance-driven I2R and IV-curve losses are secondary, but remain non-negligible. Thermal damage, bend-radius violations, and loose connections drive the majority of LCOE uplift Improving connector reliability through better installation quality, inspection, and design can meaningfully reduce lost energy, O&M costs, and LCOE.

14 SOLAR ENERGY↗

Quench Propagation On Rare-Earth Barium Copper Oxide (REBCO) Tape

Rare-earth barium copper oxide (REBCO) high-temperature superconductors can carry high currents with zero electrical resistance, enabling applications in high-field magnets, energy systems, and fusion devices. However, localized losses of superconductivity, known as quenches, pose a severe risk due to REBCO’s mechanical brittleness and slow quench propagation, complicating early detection. This work investigates quench propagation and thermal response through controlled experiments. A segmented REBCO tape soldered onto a printed circuit board (PCB) with multiple voltage taps and temperature sensors was submerged in liquid nitrogen at 77 K. In the first test, current ramping produced a quench near 360 A, consistent with theoretical current limits, but resulted in local burnout. In the second test, a heater-induced quench at 300 A propagated bidirectionally with velocities ranging from 164–226 mm/s. These results provide critical parameters for improving REBCO quench detection and protection system design while accounting for REBCO’s limited bendability.

Ju, Han [Northern Illinois U.]↗

Quench Propagation on Rare-Earth Barium Copper Oxide (REBCO) Tape

Rare-earth barium copper oxide (REBCO) high-temperature superconductors can carry high currents with zero electrical resistance, enabling applications in high-field magnets, energy systems, and fusion devices. However, the localized losses of superconductivity called a quench pose a severe risk due to REBCO’s mechanical brittleness and slow quench propagation, hence complicating early detection. This work investigates quench propagation and thermal response through controlled experiments. A segmented REBCO tape soldered on a PCB with multiple voltage taps and temperature sensors was submerged in liquid nitrogen at 77 K. In the first test, current ramping produced a quench near 360 A, consistent with theoretical current limits but resulted in a local burn. In the second test, a heater-induced quench at 300 A propagated bidirectionally with measured velocities ranging from 164–226 mm/s. These measurements provide critical parameters for improving REBCO quench detection and protection system design with accounts for REBCO's limited bendability.

Ju, Han [NIU, DeKalb]↗