Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electrical measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Electric field determination in transient plasmas: in situ & non-invasive methods

Abstract One of the primary basic plasma parameters within transient nonequilibrium plasmas is the reduced electric field strength, roughly understood as the ratio of the electrical energy given to the charged species between two collisions. While physical probes have historically been used for electric field measurements, recent advances in high intensity lasers and sensitive detection methods have allowed for non-invasive optical electric field determination in nearly any discharge configuration with time-resolution up to the sub-nanosecond range and sub-millimeter spatial resolution. This topical review serves to highlight several non-invasive methods for in situ electric field strength determination in transient plasmas ranging from high vacuum environments to atmospheric pressure and above. We will discuss the advantages and proper implementation of (i) laser induced fluorescence dip spectroscopy for measurements in low pressure RF discharges, (ii) optical emission spectroscopy based methods for nitrogen, helium or hydrogen containing discharges, (iii) electric field induced coherent Raman scattering, and (iv) electric field induced second harmonic generation. The physical mechanism for each method will be described as well as basic implementation and highlighting recent results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Turbulent electric fields in the nightside magnetosphere

Electric field measurements from the long-wire double-probe instrument (baseline of 179 m) on ISEE 1 have shown the magnetospheric electric field on auroral L shells to be extremely turbulent during periods of magnetic activity. During intense activity these turbulent electric fields can penetrate to very low L values. The variational component of the electric field is typically larger than the DC value. Measurements are presented at frequencies up to 14 Hz. Magnitudes of over 40 m V/m (zero to peak) have been observed with spectral power levels in the 1-10 Hz range greater than m squareV/sq m Hz. The spectral shape of the most intense events was generally flatter than that predicted by two-dimensional hydromagnetic cascading of energy, which argues that the source of this turbulence must be driving the plasma near these frequencies. This in turn suggests that the instability is in the low-energy plasma.

Maynard, N. C.↗

Electrical properties of the middle atmosphere

Probe techniques have been utilized extensively to measure middle atmospheric electrical properties such as the polar components of conductivity, ion mobility and density. The most variable of these parameters is conductivity, which is dependent on both charge mobility and concentration. Overall conductivity variations, attributable to different geophysical conditions, can exceed several orders of magnitude at some altitudes. Also, measurements of conductivity over the 20 to 90 km region indicate a general exponential increase with altitude, exceeding seven orders of magnitude during certain conditions. Gerdien condensers, on occasion, have measured very low-mobility positive ions in addition to the more commonly observed molecular species. These smaller mobility values appear to indicate the presence of very large ions at some altitudes, possibly charged particulates, having mass sizes greater than those identifiable by presently flown mass spectrometers. The presence of these large ions is of importance to middle atmospheric electrodynamics as a potential causal mechanism for measured large electric fields.

Mitchell, John D.↗

Electrical characterization of plasma-grown oxides on gallium arsenide

Plasma-grown GaAs oxides and their interfaces have been characterized by measuring the electrical properties of metal-oxide-semiconductor capacitors and of Schottky junctions. The current transport mechanism in the oxide at high electrical field was found to be Frankel-Poole emission, with an electron trap center at 0.47 eV below the conduction band of the oxide. The interface-state density, evaluated from capacitance and conductance measurements, exhibits a U-shaped interface-state continuum extending over the entire band gap. Two discrete deep states with high concentration are superimposed on this continuum at 0.40 and 0.70 eV below the conduction band. The results obtained from measurements on Schottky junctions have excluded the possibility that these two deep states originate from plasma damage. Possible origins of these states are discussed in this paper.

Hshieh, F. I.↗

Compositional and phase dependence of elastic modulus of crystalline and amorphous Hf 1- x Zr x O 2 thin films

The elastic moduli of amorphous and crystalline atomic layer-deposited Hf 1-x Zr x O 2 (HZO, x = 0, 0.31, 0.46, 0.79, 1) films prepared with TaN electrodes on silicon substrates were investigated using picosecond acoustic measurements. The moduli of the amorphous films were observed to increase between 211 ± 6 GPa for pure HfO 2 and 302 ± 9 GPa for pure ZrO 2 . In the crystalline films, it was found that the moduli increased upon increasing the zirconium composition from 248 ± 6 GPa for monoclinic HfO 2 to 267 ± 9 GPa for tetragonal ZrO 2 . Positive deviations from this increase were observed for the Hf 0.69 Zr 0.31 O 2 and Hf 0.54 Zr 0.46 O 2 compositions, which were measured to have moduli of 264 ± 8 GPa and 274 ± 8 GPa, respectively. These two compositions contained the largest fractions of the ferroelectric orthorhombic phase, as assessed from polarization and diffraction data. The biaxial stress states of the crystalline films were characterized through sin 2 (ψ) x-ray diffraction analysis. The in-plane stresses were all found to be tensile and observed to increase with the increasing zirconium composition, between 2.54 ± 0.6 GPa for pure HfO 2 and 5.22 ± 0.5 GPa for pure ZrO 2 . The stresses are consistent with large thermal expansion mismatches between the HZO films and silicon substrates. Furthermore, these results demonstrate a device-scale means to quantify biaxial stress for investigation on its effect on the ferroelectric properties of hafnia-based materials.

36 MATERIALS SCIENCE↗

EMP-Resilient Electric Grid Transformer Analysis

The response of a high - voltage (HV) transformer to fast rise time voltages, such as that from a electromagnetic pulse (EMP) can result in interruption of power distribution and possibly system failure. To help identify these potential occurrences, it is necessary to develop a transformer model that not only captures the input/output response of the transformer but also the internal behavior. The model constructed should cover the frequency band of interest while capturing the internal physical and electrical characteristics. This broad-band, high-fidelity model would enable the prediction of unwanted effects through simulation. A proposed modeling scheme for a HV transformer is described in Part 1 of this report. Part 2 of this report details assessments of internal voltage and electrical field holdoff testing of transformer insulation dielectric breakdown, including comparison of low frequency (DC/60 Hz) holdoff to rise times characteristic of lightning (1 s) and EMP E1 transients (10 - 30 ns). This initial project is a path toward establishing electrical grid transformer failure criteria for EMP voltage transients. We developed modeling methods and measured breakdown electrical field statistical distributions for direct current, 60 Hz, lightning and EMP characteristic voltage rise times. Methods of nanosecond-scale capacitive discharge unit high voltage source development, suggestions for derating of 60 Hz insulation maximum electrical fields for EMP nanosecond pulse voltage withstand rating, and potential methods for increasing transformer resilience to such fast rise time pulses are described.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Investigating the Electromechanical Sensitivity of Carbon-Nanotube-Coated Microfibers

The piezoresistance of carbon nanotube (CNT)-coated microfibers is examined using diametric compression. Diverse CNT forest morphologies were studied by changing the CNT length, diameter, and areal density via synthesis time and fiber surface treatment prior to CNT synthesis. Large-diameter (30–60 nm) and relatively low-density CNTs were synthesized on as-received glass fibers. Small-diameter (5–30 nm) and-high density CNTs were synthesized on glass fibers coated with 10 nm of alumina. The CNT length was controlled by adjusting synthesis time. Electromechanical compression was performed by measuring the electrical resistance in the axial direction during diametric compression. Gauge factors exceeding three were measured for small-diameter (<25 μm) coated fibers, corresponding to as much as 35% resistance change per micrometer of compression. The gauge factor for high-density, small-diameter CNT forests was generally greater than those for low-density, large-diameter forests. A finite element simulation shows that the piezoresistive response originates from both the contact resistance and intrinsic resistance of the forest itself. The change in contact and intrinsic resistance are balanced for relatively short CNT forests, while the response is dominated by CNT electrode contact resistance for taller CNT forests. These results are expected to guide the design of piezoresistive flow and tactile sensors.

36 MATERIALS SCIENCE↗

Aircraft altitude determination using multipath information in an angle-measuring navigation satellite system

In an angle-measuring navigation satellite system using a pair of crossed interferometers located on a satellite in synchronous orbit, three parameters are needed to determine a user's position unambiguously. These are the phase differences between received signals which were transmitted by the two antennas on each of the two interferometers, and the user's altitude. The two phase difference measurements yield a line of possible user locations, and the addition of the altitude measurement reduces this line to a single point. A method is proposed which makes use of the navigation signals received after reflection off the earth's surface. The iterative procedure employs the arrival time difference between direct and reflected signals. Based on previous calculations of errors in measuring the electrical parameters it is concluded that, for North Atlantic coverage and specular reflection, altitude measurements can be made with a 1-sigma error of 65 meters.

Kurjan, D.↗

Injun 5 observations of magnetospheric electric fields and plasma convection

Recent measurements of magnetospheric electric fields with the satellite Injun 5 have provided a comprehensive global survey of plasma convection at low altitudes in the magnetosphere. A persistent feature of these electric field observations is the occurrence of an abrupt reversal in the convection electric field at auroral zone latitudes. The plasma convection velocities associated with these reversals are generally directed east-west, away from the sun on the poleward side of the reversal, and toward the sun on the equatorward side of the reversal. Convection velocities over the polar cap region are normally less than those observed near the reversal region. The electric field reversal is observed to be coincident with the trapping boundary for electrons with energies E greater than 45 keV.

Gurnett, D. A.↗

Injun 5 observations of magnetospheric electric fields and plasma convection.

Recent measurements of magnetospheric electric fields with the satellite Injun 5 have provided a comprehensive global survey of plasma convection at low altitudes in the magnetosphere. A persistent feature of these electric-field observations is the occurrence of an abrupt reversal in the convection electric field at auroral-zone latitudes. The plasma convection velocities associated with these reversals are generally directed E-W, away from the sun on the poleward side of the reversal, and toward the sun on the equatorward side of the reversal. Convection velocities over the polar cap region are normally less than those observed near the reversal region. The electric-field reversal is observed to be coincident with the 'trapping boundary' for electrons with energies E greater than 45 keV. Near local noon the region of anti-sunward convection poleward of the electric-field reversal/trapping boundary corresponds to the low-altitude extension of the polar-cusp plasma.

Gurnett, D. A.↗

Rocket-triggered lightning strikes and forest fire ignition

Background information on the rocket-triggered lightning project at Kennedy Space Center (KSC), a summary of the forecasting problem there, the facilities and equipment available for undertaking field experiments at KSC, previous research activity performed, a description of the atmospheric science field laboratory near Mosquito Lagoon on the KSC complex, methods of data acquisition, and present results are discussed. New sources of data for the 1989 field experiment include measuring the electric field in the lower few thousand feet of the atmosphere by suspending field measuring devices below a tethered balloon. Problems encountered during the 1989 field experiment are discussed. Future prospects for both triggered lightning and lightning-kindled forest fire research at KSC are listed.

Fenner, James H.↗

Enhanced Fair-Weather Electric Fields Soon After Sunrise

The typical fair weather electric field at the ground is between -100 and -300 V/m. At the NASA Kennedy Space Center and US Air Force Cape Canaveral Air Station (KSC) the electric field at the ground sometimes reaches -400 to -1200 V/m within an hour or two after sunrise on days that otherwise seem to be fair weather. We refer to the enhanced negative electric fields as the "sunrise enhancement." To investigate the sunrise enhancement at KSC we measured the electric field (E) in the first few hundred meters above the ground before and during several sunrise enhancements. From these E soundings we can infer the presence of charge layers and determine their thickness and charge density.

Marshall, T. C.↗

Lightning Current Measurement with Fiber-Optic Sensor

A fiber-optic current sensor is successfully developed with many potential applications for electric current measurement. Originally developed for in-flight lightning measurement, the sensor utilizes Faraday Effect in an optical fiber. The Faraday Effect causes linear light polarization in a fiber to rotate when the fiber is exposed to a magnetic field. The polarization change is detected using a reflective polarimetric scheme. Forming fiber loops and applying Ampere's law, measuring the total light rotation results in the determination of the total current enclosed. The sensor is conformable to complex structure geometry. It is also non-conductive and immune to electromagnetic interference, saturation or hysteresis. Installation is non-intrusive, and the sensor can be safely routed through flammable areas. Two similar sensor systems are described in this paper. The first system operates at 1310nm laser wavelength and is capable of measuring approximately 300 A - 300 kA, a 60 dB range. Laboratory validation results of aircraft lighting direct and in-direct effect current amplitudes are reported for this sensor. The second system operates at 1550nm wavelength and can measure about 400 A - 400 kA. Triggered-lightning measurement data are presented for this system. Good results are achieved in all cases.

Nguyen, Truong X.↗

He/++/ and H/+/ flux measurements in the day side cusp - Estimates of convection electric field

Ion mass spectrometer measurements of He(++) and H(+) ion spectra on a satellite pass through the low-altitude (800 km) dayside cusp during the magnetically active (Kp = 60) period of March 7, 1972, are reported. These measurements in the energy-per-unit-charge range between 0.7 and 12 keV show a systematic velocity dependence in the latitudinal distributions. This dependence is explained by a dawn-dusk convection electric field of 30-60 mV/m operating in the cusp. The average velocity spectrum of He(++) is found to be significantly harder than the accompanying H(+) spectrum, suggesting the possibility of an electrostatic deceleration mechanism operating between the solar-wind source region and the low-altitude cusp.

Shelley, E. G.↗

Simultaneous measurements of auroral particles and electric currents by a rocket-borne instrument system - Introductory remarks

A rocket-borne experiment package has been designed to obtain simultaneous in situ measurements of the pitch angle distributions and energy spectra of primary auroral particles, the flux of neutral hydrogen at auroral energies, the electric currents flowing in the vicinity of the auroral arc as determined from vector magnetic data, and the modulation of precipitating electrons in the frequency range 0.5-10 MHz. The experiment package was launched by a Nike-Tomahawk rocket from Poker Flat, Alaska, at 0722 UT on Feb. 25, 1972, over a bright auroral band. This paper is intended to serve as an introduction to the detailed discussion of results given in the companion papers. As such it includes a brief review of the general problem, a discussion of the rocket instrumentation, a delineation of the auroral and geomagnetic conditions at the time of launch, and comments on the overall payload performance.

Anderson, H. R.↗

Wave rectification in plasma sheaths surrounding electric field antennas

Combined measurements of Langmuir or broadband whistler wave intensity and lower-frequency electric field waveforms, all at 10-microsecond time resolution, were made on several recent sounding rockets in the auroral ionosphere. It is found that Langmuir and whistler waves are partically rectified in the plasma sheaths surrounding the payload and the spheres used as antennas. This sheath rectification occurs whenever the high frequency (HF) potential across the sheath becomes of the same order as the electron temperature or higher, for wave frequencies near or above the ion plasma frequency. This rectification can introduce false low-frequency waves into measurements of electric field spectra when strong high-frequency waves are present. Second harmonic signals are also generated, although at much lower levels. The effect occurs in many different plasma conditions, primarily producing false waves at frequencies that are low enough for the antenna coupling to the plasma to be resistive.

Boehm, M. H.↗

Ambient and High Pressure CuNiSb 2 : Metal-Ordered and Metal-Disordered NiAs-Type Derivative Pnictides

The mineral Zlatogorite, CuNiSb 2 , was synthesized in the laboratory for the first time by annealing elements at ambient pressure (CuNiSb 2 -AP). Rietveld refinement of synchrotron powder X-ray diffraction data indicates that CuNiSb 2 -AP crystallizes in the NiAs-derived structure ( P 3 m 1, #164) with Cu and Ni ordering. The structure consists of alternate NiSb 6 and CuSb 6 octahedral layers via face-sharing. The formation of such structure instead of metal disordered NiAs-type structure ( P 6 3 / mm c, #194) is validated by the lower energy of the ordered phase by first-principle calculations. Interatomic crystal orbital Hamilton population, electron localization function, and charge density analysis reveal strong Ni-Sb, Cu-Sb, and Cu-Ni bonding and long weak Sb-Sb interactions in CuNiSb 2 -AP. The magnetic measurement indicates that CuNiSb 2 -AP is Pauli paramagnetic. First-principle calculations and experimental electrical resistivity measurements reveal that CuNiSb 2 -AP is a metal. The low Seebeck coefficient and large thermal conductivity suggest that CuNiSb 2 is not a potential thermoelectric material. Single crystals were grown by chemical vapor transport. The high pressure sample (CuNiSb 2 -8 GPa) was prepared by pressing CuNiSb 2 -AP at 700 °C and 8 GPa. However, the structures of single crystal and CuNiSb 2 -8 GPa are best fit with a disordered metal structure in the P 3 m 1 space group, corroborated by transmission electron microscopy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗