Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electric utility programs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Benefits of Dual Fuel Heat Pump Grid-responsive Control: A Model-based Control Optimization Approach Using Building and Equipment Co-simulation

Conventional dual fuel heat pumps lack the intelligent control mechanisms to efficiently manage the switch between heat pump and furnace, leading to sub-optimal energy usage and, in some cases, increased operating costs. To resolve this gap, this study applies optimized control on hybrid heat pumps. With a focus on equipment control strategies, we compare the performances of five spacing heating equipment, including a conventional heat pump (HP), a conventional furnace, a dual fuel heat pump (DFHP) with conventional control, a dual fuel heat pump with smart control, and a novel seamlessly fuel flexible heat pump (SFFHP). While DFHP runs on either gas or electricity at any given moment, SFFHP concurrently consumes gas and electricity by continuously optimizing the proportion of each. In this research, a co-simulation framework is developed by integrating a building envelope model with a physics-based heat pump simulation model to analyze the benefits of grid-responsive controls of DFHP and SFFHP. The model-based optimal controls adjust the operation of the heat pump and gas furnace based on utility price signals and marginal grid emission to minimize utility cost and CO 2 emissions for multiple climate zones, different utility tariffs, and marginal grid emission scenarios. Case studies in Chicago and Los Angeles demonstrate that SFFHP and DFHP, with model-based optimal control, can deliver significant reductions in peak demand, utility cost, and CO 2 emission. In Chicago, SFFHP and smart controlled DFHP yield up to 64.7% and 61.7% utility cost reduction and up to 15.7% and 8.5% CO 2 emission reduction compared to the gas furnace. In Los Angeles, SFFHP and smart controlled DFHP achieve up to 43.6% and 40.1% utility cost reduction and up to 13.8% and 14.1% CO2 emission reduction compared to conventional heat pumps. In conclusion, by leveraging the fuel flexibility nature of dual fuel heat pumps, the model-based control optimization approach makes dual fuel heat pump an attractive option for demand response programs.

Control↗

sCO2 Primary Power Large-Scale Pilot Plant FEED Summary

Echogen Power Systems and its project partners the Electric Power Research Institute, CDM Smith, Riley Power Inc. (a Babcock Power Inc. company), and the University of Missouri completed the Front-End Engineering Design (FEED) study of a nominal 10 MWe supercritical carbon dioxide (sCO2) large-scale pilot plant based on Recompression Brayton Cycle (RCBC) architecture. The FEED study was completed under Phase II of the U.S. Department of Energy Fossil Fuel Large-Scale Pilots program. The FEED study scope included the preliminary design of the combustion and environmental control systems, the primary heater, the sCO2 power cycle and its associated turbomachinery, and the balance of plant equipment to determine accurate cost and schedule requirements for fabrication and installation of the system at the University of Missouri’s Combined Cooling, Heat, and Power Plant, located in Columbia, Missouri. The RCBC sCO2 cycle presents superior thermodynamic efficiency compared to steam-Rankine cycles and is adaptable to a broad range of heat sources. The risk aversion of the power generation industry requires a successful large-scale pilot plant demonstration to enable financing and deployment of commercial-scale plants. Therefore, successful construction and demonstration of a 10 MWe RCBC sCO2 power plant would empower a transformational step forward for the efficiency of the next generation of utility power plants. This paper provides details on the primary heater, environmental control systems, and sCO2 power cycle design and performance.

01 COAL, LIGNITE, AND PEAT↗

All-Digital Plug and Play Passive RFID Sensors for Energy Efficient Building Control

This is the final report for the project “All-Digital Plug and Play Passive RFID Sensors for Energy Efficient Building Control”, funded by DOE, and performed by Clemson University, Phase IV Engineering and Harvard University from October 1, 2016 to December 31, 2020. The main objective of this project is to develop, demonstrate and pre-commercialize a novel, plug & play, battery-free, wireless sensor technology to enable low-cost (<$10 per node) indoor and outdoor temperature and humidity measurement for energy efficient building controls and operations. The proposed technology is based on the novel concept of all-digital sensing and its seamless integration with the passive RFID technology. This project focuses on the design, fabrication, material optimization, interrogation electronics, validation, and demonstration of the novel sensor nodes for building applications. The specific objectives of this research program include: (1) Design, fabricate and optimize a compact, robust, and high-resolution digitizer, which could convert rotation angle into digital numbers. (2) Develop the multi-physics-based modeling and simulation of the temperature/humidity transducer to derive a rational design of the architecture, dimension, structure, materials (i.e., mechanical, electrical, thermal and hygroscopic) properties and functions of the sensor node. (3) Design, fabricate and optimize the bi-material based humidity sensitive coil which could linearly transduce the environmental relative humidity variations to rotation angles. (4) Design, fabricate and optimize an UHF RFID platform which could support long-range passive wireless communications of 8-bit digital numbers. (5) Design, fabricate and optimize the miniaturized all-digital sensor using MEMS technology. (6) Validate the integrated all-digital sensing system in a real building environment to test the system’s performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Tunisia Air Conditioner Market Assessment

Air conditioners contribute significantly to peak power demand during Tunisia's hot summers. In 2021, the Tunisian Electricity and Gas Company (STEG) recorded a peak demand of 4,472 megawatts in August, estimating that 44% of that demand was due to the operation of air conditioners. The Tunisian government, through its Agence Nationale pour la Maitrise de L'Energie (ANME) and all of its partners, is called on to take advantage of the significant potential for energy efficiency and to achieve the objectives it has set for itself by accelerating the implementation of programs that expand the adoption of efficient appliances, including air conditioners. This report aims to assess the Tunisian market for air conditioners, particularly in terms of energy performance. The report provides an overview of the size and characteristics of the AC market in Tunisia, including product types, origins, and proportion of imports to locally manufactured units; an estimation of the informal market; energy performance; and price.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

South Africa: Framework for Energy Efficiency Demand Side Management

In July 2022, President Cyril Ramaphosa announced an emergency response plan to address the growing electricity crisis in South Africa, which included the necessity for customers of Eskom, South Africa’s primary electricity supplier, to implement demand-side energy efficiency measures. This report is the second of two reports that provides the foundation for a strategic Demand-Side Management (DSM) approach to reduce load shedding and maximize energy savings in South Africa, though inter-governmental collaboration and increased coordination of energy efficiency activities. The first report focuses on the experience of Eskom’s rate-funded Integrated Demand Management (IDM) programme, from its beginning in 2004 to today, highlighting the factors that led to failed support for the programme. This second report focuses on addressing the challenges identified in the first report and describes the elements of a policy framework to develop a sustained DSM program to meet the government’s energy efficiency goals in terms of greenhouse gas emissions reduction and social equity and inclusion to achieve a just transition.

24 POWER TRANSMISSION AND DISTRIBUTION↗

2020 Can Do Colorado E-Bike Mini Pilot Program Study

### The Colorado Energy Office conducted a mini pilot program study as part of the Can Do Colorado initiative, providing e-bikes to 13 low-income participants. The program aimed to encourage energy-efficient transportation during the COVID-19 pandemic as transit services were reduced and people were concerned about exposure. The insights garnered from this small-scale pilot study informed the design of a full-scale, 2-year pilot in locations across Colorado. For more information about the mini pilot program, see NLR's [Preliminary Results Report](https://www.nlr.gov/docs/fy21osti/79657.pdf). Micromobility options such as e-bikes offer a solution for improving energy efficiency for short-distance trips, especially in urban areas. Pedal-assist e-bikes use an electric motor and battery to help power the bike. The motor amplifies the power behind each pedal stroke, augmenting the energy you put into the bike. #### Data Collection Agency The Colorado Energy Office conducted the survey. #### Survey Methodology Participants in the program received a Momentum LaFree E+ e-bike (Class 1) and accessories at no cost and manually submitted travel data and feedback for 3 months using the CanBikeCo App. The smartphone app, developed in partnership with NLR, used a customized version of the [NLR OpenPATH platform](https://www.nlr.gov/transportation/openpath.html). #### Survey Records and Data Survey records include a total of 13 participants. This dataset contains 3 months of end-to-end, multimodal travel data manually submitted via smartphone app by 13 low-income essential workers in the greater Denver area. The data includes distance, mode (e.g., e-bike, car, transit), trip purpose, and demographic information.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A multi-level load shape clustering and disaggregation approach to characterize patterns of energy consumption behavior

This study presents representative electrical load shapes, disaggregated to the end-use level, for over 5000 customer clusters across California’s residential, commercial, industrial and agricultural sectors. We developed a novel, multi-level load shape clustering approach for residential and commercial sectors leveraging interval meter data for over 350,000 California utility customers collected as a part of the Phase 4 California Demand Response (DR) Potential Study. The clustering approach allowed us to identify typical consumption patterns and categorize customers based on their daily load shape displayed throughout the year. For example, we were able to identify customers with particular energy technologies such as electric vehicles and rooftop solar, as well as building occupancy types such as restaurants, grocery stores and even unoccupied buildings, based solely on whole-building interval data. We then combined the load shape-based clusters with other customer information including building type, climate, geographical area, total consumption and low-income status, to create a set of customer clusters based on both demographics and usage patterns. Total cluster electricity demand was then disaggregated into a wide variety of end-uses using weather normalization and other publicly available end-use load shape datasets. The resulting disaggregated cluster load shapes will be released in anonymized form as part of the Phase 4 DR Potential Study. They will have wide-ranging applications in energy research and policy analysis, including estimation of energy efficiency (EE) and DR potential on the end-use level, time-dependent valuation of EE savings, building stock modeling, and developing customer targeting strategies for EE and DR programs.

Murthy, Samanvitha↗

Preliminary Process and Instrumentation Design of Advanced Reactor Integration with Refineries and Hydrogen Production Facilities

With the ongoing push to decarbonize energy use and especially greenhouse gas emissions across all sectors, there are incentives to investigate how nuclear reactors may be used to generate clean energy and be used in various energy economies beyond just the electrical grid. Two initial integrations, high temperature steam electrolysis (HTSE) and oil refineries, are investigated in this first DOE Integrated Energy Systems (IES) program detailed industrial integration design report. Increasingly detailed reports are anticipated both for the industries discussed in this report and for additional industries in the future of the program. This report is a robust starting point showing how integration thermodynamic analysis establishes the requirements on the reactor and methods by which those requirements can be evaluated for specific reactor designs. Two Advanced Reactor Demonstration Program awardees are selected as representative designs for their respective technologies: NuScale for light-water reactors (LWRs) and X-Energy for high temperature gas reactors (HTGRs). Other reactor technologies or specific reactor configurations would require specific analysis similar to what is done in this report, thus this report can be a reference point by which to extend this work to other nuclear plant designs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Physical and Electrical Characterization of Aluminum Polymer Capacitors

Conductive polymer aluminum capacitor (PA capacitor) is an evolution of traditional wet electrolyte aluminum capacitors by replacing liquid electrolyte with a solid, highly conductive polymer. On the other hand, the cathode construction in polymer aluminum capacitors with coating of carbon and silver epoxy for terminal connection is more like a combination of the technique that solid tantalum capacitor utilizes. This evolution and combination result in the development of several competing capacitor construction technologies in manufacturing polymer aluminum capacitors. The driving force of this research on characterization of polymer aluminum capacitors is the rapid progress in IC technology. With the microprocessor speeds exceeding a gigahertz and CPU current demands of 80 amps and more, the demand for capacitors with higher peak current and faster repetition rates bring conducting polymer capacitors to the center o( focus. This is because this type of capacitors has been known for its ultra-low ESR and high capacitance. Polymer aluminum capacitors from several manufacturers with various combinations of capacitance, rated voltage, and ESR values were obtained and tested. The construction analysis of the capacitors revealed three different constructions: conventional rolled foil, the multilayer stacking V-shape, and a dual-layer sandwich structure. The capacitor structure and its impact on the electrical characteristics has been revealed and evaluated. A destructive test with massive current over stress to fail the polymer aluminum capacitors reveals that all polymer aluminum capacitors failed in a benign mode without ignition, combustion, or any other catastrophic failures. The extraordinary low ESR (as low as 3 mOMEGA), superior frequency independence reported for polymer aluminum capacitors have been confirmed. For the applications of polymer aluminum capacitors in space programs, a thermal vacuum cycle test was performed. The results, as expected, show no impact on the electrical characteristics of the capacitors. The breakdown voltage of polymer capacitors has been evaluated using a steady step surge test. Initial results show the uniform distribution in the breakdown voltage for polymer aluminum capacitors. Polymer aluminum capacitors with a combination of very high capacitance, extraordinary low ESR, excellent frequency stability, and non-ignite benign failure mode make it a niche fit in space applications for both today and future. Polymer capacitors are apparently also the best substitutes of the currently used MnO2-based tantalum capacitors in the low voltage range. However, some critical aspects are still to be addressed in the next phase of the investigation for PA capacitors. These include the long term reliability test of 125 C dry life and 85 C/85%RH humidity, the failure mechanism and de-rating, the radiation tolerance, and the high temperature performance. All of the above requires the continuous NEPP funding and support.

Liu, David (Donghang)↗

Using National-Scale Data to Inform Coal Power Plant Redevelopment and Coal Community Revitalization Planning

In the United States, individual coal plants have high variation in their construction and operation. Coal plants commonly have multiple units, with different commissioning ages, operational position, and maintenance conditions – even multiple fuels. These units may be in changing states of utilization, with variation in productivity depending on economic contexts. Coal plants themselves may be temporarily offline, mothballed, retired, or decommissioned due to owner/operator portfolios or market conditions, and the current posture of the plant may be difficult to ascertain without local news sources (Tarekegne et al. 2021). Anticipated dates of plant closures are prospectively represented to regulators and to the Energy Information Administration (EIA), but may also experience uncertainty due to the engineering, environmental, economic and social complexity of closing a very large power plant. As noted in this report, closure of the first unit to the last within a single plant may span more than 20 years. Yet tracking and predicting the position of our nation’s coal fleets on a national scale is deeply important. In developing a case for federal datasets and an approach to building and curating these data, this report identified that data must have high fidelity at the plant-level to be meaningful in aggregate. Plant-scale detail is also a match for its application: national priorities in federal investment range from economic revitalization for coal plant communities to maintaining reliable electric grid operations. This document is organized into a statistical review of coal plant retirements, past and prospective, in the United States; trends in the relationship between closures and existing federal investment programs for community revitalization; and potential methods for accelerating site redevelopment through advanced geospatial analysis based on federal data.

01 COAL, LIGNITE, AND PEAT↗

Model-based predictive control of multi-stage air-source heat pumps integrated with phase change material-embedded ceilings

This paper presents a model-based predictive control strategy to optimize the operations of phase change material (PCM) ceiling panels coupled with a multi-stage air-source heat pump. A three-stage prototype heat pump unit has been built and tested in the laboratory, with the low and medium stages designed for space heating/cooling and the high compression stage dedicated to charging of the PCM energy storage. To facilitate optimal control of the integrated heat pump system, a mixed-integer linear programming formulation is derived through linearization of the heat pump model and a mixed-integer reformulation of the PCM dynamic governing equations. A predictive control strategy is synthesized based on the resultant control formulation and implemented in a receding horizon scheme that optimizes the PCM charging and the zone temperature schedules simultaneously to leverage both the passive (associated with building construction materials) and active (PCM) storage capacities of a building. The control strategy has been tested along with three benchmarking control scenarios using a co-simulation platform for a prototypical detached house in Atlanta, GA. In this study, test results showed that application of the proposed control strategy to the PCM-integrated heat pump could provide 27.1% electricity cost savings while a fine tuned rule-based control strategy could achieve cost savings of 20.4%, compared to a baseline case without PCM storage, under a time-of-use rate tariff.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Air compressor load forecasting using artificial neural network

Air compressor systems are responsible for approximately 10% of the electricity consumed in United States and European Union industry. As many researches have proven the effectiveness of using Artificial Neural Network inair compressor performance prediction, there is still a need to forecast the air compressor electrical load profile. The objective of this study is to predict compressed air systems’ electrical load profile, which is valuable to industry practitioners as well as software providers in developing better practice and tools for load managementand look-ahead scheduling programs. Two artificial neural networks, Two-Layer Feed-Forward Neural Networkand Long Short-Term Memory were used to predict an air compressors electrical load. Compressors with three different control mechanisms are evaluated with a total number of 11,874 observations. Here, the forecasts were validated using out-of-sample datasets with 5-fold cross-validation. Models produced average coefficient ofdetermination values from 0.24 to 0.94, average root-mean-square errors from 0.05 kW - 5.83 kW, and meanabsolute scaled errors from 0.20 to 1.33. The results indicate that both artificial neural networks yield goodresults for compressors using variable speed drive (average R 2 = 0.8 and no naïve forecasting), only the longshort-term memory model gives acceptable results for compressors using on/off control (average R 2 = 0.82 and no naïve forecasting), and no satisfactory results are obtained for load/unload type air compressors (models constituting active forecasting).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Northwest — Advanced Grid Interactive Load Efficiency (AGILE) : A Techno-economic Assessment

The Advanced Grid Interactive Load Efficiency project team, led by Energy Northwest, was awarded funding as part of the fourth round of the Clean Energy Fund program to investigate, co-create, and complete a preliminary design for grid-interactive efficient buildings (GEBs) for a number of schools served by Grays Harbor PUD. The project team has evaluated different combinations of systems at selected school buildings and the potential to respond to grid and customer needs, and develop a preliminary system technical design, including specifying desired GEB technology options, determining communication and electrical interface requirements, assessing control software sensor requirements, and interfacing with building management systems. PNNL led the techno-economic assessment efforts, leveraging its advanced modeling and analytical methods and tools developed for building-to-grid integration. This report documents the economic assessment for different GEB design options, encompassing an in-depth examination of use cases and value propositions, assumptions and inputs, models, methods, case studies, as well as key findings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

IM3 Projected U.S. Western Interconnection Grid Stress Dataset

This dataset provides projected grid stress and reliability results (including all model inputs and outputs from GO WEST and TEP) for Integrated Multisector, Multiscale Modeling (IM3) Phase 2 simulations across eight different scenarios for the U.S. Western Interconnection through 2055. The scenarios include combinations of two Shared Socioeconomic Pathways (SSP3 and SSP5) with four high-resolution climate projections specific to the United States from a set of Thermodynamic Global Warming (TGW) simulations. These climate projections include "hotter" and "cooler" variants for two Representative Concentration Pathways (RCP4.5 and RCP8.5). The resulting eight simulations are: rcp45cooler_ssp3 rcp45cooler_ssp5 rcp45hotter_ssp3 rcp45hotter_ssp5 rcp85cooler_ssp3 rcp85cooler_ssp5 rcp85hotter_ssp3 rcp85hotter_ssp5 GO WEST is an open-source power grid modeling framework for the U.S. Western Interconnection, which allows users to tailor the model depending on their research study and science questions. It covers 28 balancing authorities (BAs) and 12 states in U.S. Western Interconnection. GO WEST allows users to select different number of nodes and come up with a simplified network by utilizing 10,000 nodal topology of the U.S. Western Interconnection (ACTIVSg10k). Users can select different number of nodes, mathematical formulations (linear programming vs. mixed-integer linear programming), transmission line limit scaling factors, and hurdle rate scaling factors. GO WEST offers a unit commitment and economic dispatch (UC/ED) module to simulate grid operations on an hourly scale. In this sense, users can calibrate and validate their model versions by comparing model outputs to historical datasets. TEP is an open-source transmission capacity expansion model, built on the GO WEST framework. It utilizes linear programming to optimize transmission capacity addition investment on existing lines within the GO WEST framework. The TEP model only increases the thermal capacity of existing transmission lines and does not add new lines to the system, which leaves the topology preserved. In order to use TEP model, users need to create scenarios with the GO WEST framework. Please refer to README file for a detailed description of the dataset including individual files and references.

Capacity Expansion Model↗

Validating Connected, Automated, and Electric Vehicle Models and Simulation - Research Performance Progress Report

The objective of this project is to test connected and automated vehicles with both electrified and internal combustion engine powertrains to support updates and validation of modeling and simulation tools. This includes the development of the components and network architecture to execute and collect empirical data for multiple scenarios and traffic interactions. Specific program objectives include: • Translate Lab algorithms into vehicle and infrastructure controls • Conduct physical testing at realistic scale • Evaluate system performance • Improve models using empirical data • Improve control algorithms from lessons learned • Identify system and algorithm assumptions which need refinement It is important to note that the objective of this project was not to demonstrate the efficacy of the selected algorithms to improve energy efficiency but rather to validate and improve modeling and simulation tools using empirical data. While it is a desirable outcome to concurrently demonstrate improved energy efficiency through use of these algorithms, and in most cases that was the outcome, the success of this project was not predicated on the performance of the algorithm towards improving energy efficiency across all scenarios and test matrices.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of an Energy Services Interface for the EGoT

The Energy Services Interface (ESI) is a set of rules that ensure private, secure, and trustworthy information exchange between Grid Service Providers (GSPs) and utility customers. Large-scale adoption of Distributed Energy Resources (DERs) will be necessary for GSPs to dispatch effective grid services, and to stimulate technological innovations in DER and DERMS (DER Management Systems) technologies, as well as novel grid service programs. The ESI promotes these objectives by advancing a set of rules and interoperability requirements that define bi-directional, service-oriented, logical interfaces between GSPs and customers’ DERs, with expectations for privacy, security, and trust. The ESI rules and interoperability requirements establish boundaries between customers and GSPs that delineate the functions and responsibilities that must be implemented by the developers of Energy Grid of Things (EGoT) ecosystem products. These rules impose constraints on the implementation of a DERMS. The ESI interoperability requirements are based on the Interoperability Maturity Model (IMM), developed by the Grid Modernization Laboratory Consortium. By emphasizing private, secure, and trustworthy information exchange, and by mandating a service-oriented and interoperable architecture, the ESI promotes the development of an EGoT ecosystem that motivates customer participation and technological innovation. Interoperability will encourage innovation by reducing barriers to entry and increasing confidence of stakeholders. Customers will be willing to participate in DER service programs that establish trust and emphasize customer choice. Large-scale customer participation ensures GSPs have ample DER resources to provide grid services that have significant impact on grid reliability and reduce electricity cost for consumers. This in turn signals economic opportunities that encourage innovation, resulting in the development of a robust EGoT ecosystem.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analysis of HolosGen Sub-Scale Simulator with Plant Dynamics Code

The Subcritical Power Module Sub-scale Simulator (SPM-SS) has been designed and constructed by HolosGen LLC under the ARPA-E MEITNER program to simulate the thermal-hydraulic and heat transfer behavior of the full-scale Holos-Quad Subcritical Power Modules (SPMs). Four coupled SPMs, each rated at 5.5MW, form the Holos-Quad gas-cooled microreactor design. The SPM-SS represents a substantially scaled-down system with a power rating less than 40 kW, equipped with an electrically heated fuel cartridge heat exchanger, an electrically heated compressor heat exchanger, and a valve actuated turbine heat exchanger, in addition to a recuperator and a cooler heat exchanger. The fuel cartridge represents a portion of the full-scale SPM core, the compressor heat exchanger mimics the temperature changes resulting from the compressor’s turbomachinery inefficiencies, the turbine heat exchanger mimics the expansion process normally occurring through the turbine, while the recuperator and cooler heat exchangers complete the subscale simulator loop. The heaters equipping the fuel cartridge and the compressor heat exchangers are electronically controlled to simulate normal and off-normal SPM operating conditions. The full-scale Holos-Quad SPM design eliminates the traditional balance of plant and executes thermal-to-electric energy conversion by means of an intercooled Brayton cycle with decoupled compressor-turbine turbomachinery. The Holos-Quad full-scale design is equipped with a multi-stage axial Low- and High-Pressure compressor, and a multistage axial turbine. The SPM-SS is designed for testing and validation of selected components which are instead coupled by a traditional balance of plant. The SPMSS is not equipped with turbo-machinery (compressor and turbine) as the development of these components were excluded from the scope of work under the ARPA-E MEITNER funding program. The SPM-SS balance of plant enables modifications, replacement and testing of individual components with different working fluids and is designed to include the turbo-machinery components that will be developed in future research . The SPM-SS can be operated with different gases, variable mass-flow-rates, pressures, and temperatures to obtain test data for selected components, whose performance can be scaled to validate the computer model of the full-scale SPM at various conditions (e.g., start-up, transients conditions). The SPM-SS can operate at the maximum Holos-Quad design pressure of 7 MPa, and a maximum temperature limited to 650 °C by the electrical heaters. Several SPM-SS tests have been conducted and analyzed with the Plant Dynamics Code (PDC) developed at the Argonne National Laboratory (ANL). These tests aimed at validating the PDC modeled predictions of the full-scale Holos-Quad design with data from selected SPM-SS components. In order to address SPM-SS specific characteristics, such as components heat losses and absence of turbomachinery components, some modifications to the PDC have been implemented to factor the design differences from the full-scale Holos-Quad SPM to the SPM-SS. As the PDC offers capabilities to analyze systems with different working fluids, air, nitrogen, and helium were utilized as the SPM-SS working fluids. Air was utilized to fine-tune the SPM-SS Systems Structures and Components (SSCs), nitrogen was utilized to pressure test the SPM-SS loop at the SPMs design maximum pressure of 7MPa. Helium was utilized as the working fluid circulating through the SPM-SS SSCs for specific tests to validate the PDC predictions of the fuel cartridge heat exchanger. SPM-SS tests data were also analyzed with both the steady-state and transient analysis capabilities offered by the PDC. This report describes the PDC analysis of the SPM-SS tests data, including the necessary code modifications and comparison of the code results with the experimental data. Based on the results, a discussion is presented on how the analysis supports design and transient calculations of the full-scale Holos-Quad microreactor. Also based on the results of this work, recommendations are made for future optimizations of the SPM-SS components and PDC model development needs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Environmental and economic optima of solar home systems design: A combined LCA and LCC approach

Here, we compare the economic and environmental optimal design of Solar Home Systems (SHSs) and explore the role of economic incentives (such as tariffs and technology costs) in approximating the two optima. To achieve that, we present a methodology for the environmental and economic evaluation of grid-connected SHSs: user-scale electric systems involving a photovoltaic (PV) power system and a battery energy storage system. The proposed methodology is based on a mixed integer linear programming (MILP) optimization, life cycle assessment and life cycle costing. This methodological framework is applied to a case study involving a typical SHS installation in Italy. The results of the environmental optimal design brought to the evaluation of a 3.25 kW PV assisted by 8.66 kWh of nickel cobalt manganese batteries, whereas the costs of the SHS are minimized by a small PV system (less than 1 kW). Results underline that the environmental optimal configurations rely on battery technologies, which entails a significant cost compared to the grid connection. In contrast, the economic optimal design solutions is less impactful than the grid mix both from an environmental and economic points of view. Thanks to a reduction of batteries and PV costs, the environmental impact of the economic optimal design is expected to decrease in the future.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗