Effects of B 2 O 3 on the Growth, Structural, and Magneto-Optical Properties of Yttrium Iron Garnet Single-Crystal Fibers

This study explores the fabrication of yttrium iron garnet (YIG) single crystal fibers using the laser heated pedestal growth (LHPG) method with the experimental addition of B 2 O 3 . The incorporation of B 2 O 3 facilitates the fiber fabrication process by lowering the required growth temperatures and likely modifying melt viscosity behavior, consistent with the established fluxing behavior of B2O3 and the comparative viscosity trend observed in the TMA−VFT analysis, thereby improving process efficiency while maintaining fiber quality. Structural characterization using EBSD and SC-XRD reveals a transition from polycrystalline to single-crystal behavior, with improved alignment along the [111] direction without altering the garnet structure. Magnetic measurements show increases in saturation magnetization in B 2 O 3 -assisted fibers. Three-dimensional anisotropy energy modeling, based on EBSD-derived Euler angles, indicates that the enhanced crystallinity and orientation contribute to reorientation of MCA energy distribution due to improved crystallographic alignment. Faraday rotation measurements show that the B 2 O 3 -assisted sample exhibits a rotation angle closer to reported values for high-quality YIG, suggesting improved phase purity and crystallographic quality. These findings demonstrate that B 2 O 3 -assisted LHPG growth is a scalable and nontoxic approach to producing high-performance YIG fibers for integrated photonic and magnetic field sensing applications.

Crystal structure↗

Data-driven electrolyte design for lithium metal anodes

Improving Coulombic efficiency (CE) is key to the adoption of high energy density lithium metal batteries. Liquid electrolyte engineering has emerged as a promising strategy for improving the CE of lithium metal batteries, but its complexity renders the performance prediction and design of electrolytes challenging. Here, we develop machine learning (ML) models that assist and accelerate the design of high-performance electrolytes. Using the elemental composition of electrolytes as the features of our models, we apply linear regression, random forest, and bagging models to identify the critical features for predicting CE. Our models reveal that a reduction in the solvent oxygen content is critical for superior CE. We use the ML models to design electrolyte formulations with fluorine-free solvents that achieve a high CE of 99.70%. This work highlights the promise of data-driven approaches that can accelerate the design of high-performance electrolytes for lithium metal batteries.

25 ENERGY STORAGE↗

Eco Look-Ahead Control of Battery Electric Vehicles and Roadway Grade Effects

Roadway grade is one of the major variables that affects a vehicle’s energy consumption. This study demonstrates the potential benefits of an eco look-ahead control for battery electric vehicles (BEVs). The proposed eco look-ahead controller was developed for the lead vehicle of a platoon of BEVs. The eco look-ahead control predicts the optimum speed and acceleration levels within a preset speed window to minimize energy consumption considering the instantaneous energy used and the regenerated energy. The developed BEV eco look-ahead control system integrates a BEV energy consumption model and a powertrain model to save fuel while maintaining vehicle speed within a user-specified window. In addition, the study demonstrates the effects of roadway grade on BEV energy consumption. The results show that the energy consumption of BEVs are significantly reduced on downhill roads compared with internal combustion engine vehicles owing to regenerative braking. Specifically, testing showed that BEVs could even produce extra energy on downhill roads. The study also tested the eco look-ahead control on an 18-km section of I-81 and found that the system produced savings of 8.51% and 26.88% in the uphill and downhill directions, respectively. This study demonstrated that regenerative energy in BEVs is a critical factor in energy efficiency and the developed eco look-ahead control significantly improved the energy efficiency for BEVs.

Engineering↗

Role of Magnetic Anisotropy on the Hyperthermia Efficiency in Spherical Fe3−xCoxO4 (x = 0–1) Nanoparticles

The use of magnetic nanoparticles in the treatment of cancer using alternating current hyperthermia therapy has shown the potential to replace or supplement conventional cancer treatments, radiotherapy and chemotherapy, which have severe side effects. Though the nearly spherical sub-10 nm iron oxide nanoparticles have their approval from the US Food and Drug Administration, their low heating efficiency and removal from the body after hyperthermia treatment raises serious concerns. The majority of magnetic hyperthermia research is working to create nanomaterials with improved heating efficiency and long blood circulation time. Here, we have demonstrated a simple strategy to enhance the heating efficiency of sub-10 nm Fe3O4 nanoparticles through the replacement of Fe+2 ions with Co+2 ions. Magnetic and hyperthermia experiments on the 7 nm Fe3−xCoxO4 (x = 0–1) nanoparticles showed that the blocking temperature, the coercivity at 10 K, and the specific absorption rate followed a similar trend with a maximum at x = 0.75, which is in corroboration with the theoretical prediction. Our study revealed that the heating efficiency of the Fe3−xCoxO4 (x = 0–1) nanoparticles varies not just with the size and saturation magnetization but also with the magnetocrystalline anisotropy of the particles.

36 MATERIALS SCIENCE↗

System and method for characterization of retrofit opportunities in building using data from communicating thermostats

Systems and methods for characterization of retrofit opportunities are described. The methods may comprise computing, using at least one computing device disposed remote from a building and based at least in part on heating, ventilation and air conditioning (HVAC) runtime data associated with the building, one or more thermal characteristics of the building. In some embodiments, a model-predicted indoor temperature may be fitted against thermal data measured by a thermostat at the building. The thermal characteristic of the building may comprise a thermal insulation, an air leakage rate and/or an HVAC efficiency. The method may be used to determine, using the at least one computing device, suitability of the building for a retrofit opportunity to improve energy efficiency of the building. Determining the suitability may comprise evaluating the one or more thermal characteristics. The HVAC runtime data may be computed based on data received from a thermostat or a meter, such as an electric or a gas meter.

Zeifman, Michael↗

System and method for characterization of retrofit opportunities in building using data from interval meters

Systems and methods for characterization of retrofit opportunities are described. The methods may comprise computing, using at least one computing device disposed remote from a building and based at least in part on heating, ventilation and air conditioning (HVAC) runtime data associated with the building, one or more thermal characteristics of the building. In some embodiments, a model-predicted indoor temperature may be fitted against thermal data measured by a thermostat at the building. The thermal characteristic of the building may comprise a thermal insulation, an air leakage rate and/or an HVAC efficiency. The method may be used to determine, using the at least one computing device, suitability of the building for a retrofit opportunity to improve energy efficiency of the building. Determining the suitability may comprise evaluating the one or more thermal characteristics. The HVAC runtime data may be computed based on data received from a thermostat or a meter, such as an electric or a gas meter.

Zeifman, Michael↗

Low Precision and Efficient Programming Languages for Sustainable AI: Final Report for the Summer Project of 2024

This document contains all relevant material generated during the authors' summer internship at NREL in 2024. This report shows how to improve energy efficiency of a few code samples by using low-precision data types combined with mixed-precision algorithms. The main applications considered here are (i) linear system solvers using mixed precision, and (ii) neural networks using mixed precision. This report also discusses how programming languages affect energy consumption of algorithms, energy metrics for a code and tools, and the available current software and hardware infrastructure.

97 MATHEMATICS AND COMPUTING↗

Iterative methods in GPU-resident linear solvers for nonlinear constrained optimization

Linear solvers are major computational bottlenecks in a wide range of decision support and optimization computations. The challenges become even more pronounced on heterogeneous hardware, where traditional sparse numerical linear algebra methods are often inefficient. For example, methods for solving ill-conditioned linear systems have relied on conditional branching, which degrades performance on hardware accelerators such as graphical processing units (GPUs). To improve the efficiency of solving ill-conditioned systems, our computational strategy separates computations that are efficient on GPUs from those that need to run on traditional central processing units (CPUs). Our strategy maximizes the reuse of expensive CPU computations. Iterative methods, which thus far have not been broadly used for ill-conditioned linear systems, play an important role in our approach. In particular, we extend ideas from Arioli et al., (2007) to implement iterative refinement using inexact LU factors and flexible generalized minimal residual (FGMRES), with the aim of efficient performance on GPUs. In conclusion, we focus on solutions that are effective within broader application contexts, and discuss how early performance tests could be improved to be more predictive of the performance in a realistic environment.

97 MATHEMATICS AND COMPUTING↗

Electrical Measurement and Verification of Energy in DC Buildings

Today's selection of DC buildings features a diverse set of electrical topologies and turnkey solutions, and each has specific design trade-offs and optimizations. Designers desperately need standardized metrics and procedures for measurement and verification (M&V) to analyze and compare the advantages of each DC solution to traditional AC building networks. This work develops the Measurement-Informed Modeling (MIM) method, which can be used to determine full-building efficiency and energy savings. The MIM M&V procedure develops a building model, and refines the model with metered data. This work demonstrates the MIM method by measuring the full-building efficiency of two DC buildings operated by the Institute of Building Research in Shenzhen, China. The MIM procedure can ultimately be used to compare and improve the efficiency of various DC topologies.

buildings↗

Natural Gas Combined Cycle (NGCC) Power Plants with Carbon Capture and Exhaust Gas Recycle (EGR)

The purpose of this study is to determine the cost and performance of natural gas combined cycle (NGCC) power plants using state-of-the-art gas turbines with post combustion carbon capture and recycle streams designed to increase the CO 2 concentration in the inlet to the capture system. Increasing the inlet CO 2 concentration by exhaust gas recycle (EGR) is expected to improve the efficiency of the capture system and reduce its costs. Primary results indicate that adding EGR to NGCC plants with CO 2 capture results in minimal improvement to the cost of electricity. The addition of 50 percent EGR in NGCC plants with CO 2 capture reduces the LCOE by 2 percent over the LCOE of the same design without EGR as reference. Including the EGR ductwork and cooler in a greenfield plant design could still be prudent since there is some cost advantage to EGR and it would allow more flexibility for taking advantage of future improvements in the technology.

20 FOSSIL-FUELED POWER PLANTS↗

Urban Combined Heat and Power with Integrated Renewables and Energy Storage

This project demonstrated how incorporating a diverse generation and storage portfolio allows an urban district energy system to improve its efficiency by at least 50% and increase its backup power by at least 40% with a return on investment of at least ten years. The improvement was evaluated against the baseline operations for two urban district energy systems (DESs): a synthetic DES and a George Washington University DES. The DES techno-economic framework we developed yields reliability, resilience, and vulnerability indices for urban DESs (including generation and storage) with designation of which technologies improve the security and resiliency metrics by at least 20% compared to the status quo. The indices are benchmarked against baseline scenarios, and cost projections (capital cost and return on investment) to achieve the 20% improvement are reported. The energy management system we developed to conduct these analyses was incorporated into a user-friendly interface that can be used for decision-making by a user with no technical or programming background.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Model Predictive Control of Discrete-Continuous Energy Systems via Generalized Disjunctive Programming

Generalized Disjunctive Programming (GDP) provides an alternative framework to model optimization problems with both discrete and continuous variables. The key idea behind GDP involves the use of logical disjunctions to represent discrete decisions in the continuous space, and logical propositions to denote algebraic constraints in the discrete space. Compared to traditional mixed-integer programming (MIP), the inherent logic structure in GDP yields tighter relaxations that are exploited by global branch and bound algorithms to improve solution quality. In this paper, we present a general GDP model for optimal control of hybrid systems that exhibit both discrete and continuous dynamics. Specifically, we use GDP to formulate a model predictive control (MPC) model for piecewise-affine systems with implicit switching logic. As an example, the GDP-based MPC approach is used as a supervisory control to improve energy efficiency in residential buildings with binary on/off, relay-based thermostats. A simulation study is used to demonstrate the validity of the proposed approach, and the improved solution quality compared to existing MIPbased control approaches.

Bhattacharya, Arnab↗

Sensor selection and tool wear prediction with data‐driven models for precision machining

Abstract Estimation of tool wear in precision machining is vital in the traditional subtractive machining industry to reduce processing cost, improve manufacturing efficiency and product quality. In this vein, fusion of time and frequency‐domain features of commonly sensed signals can provide an early indication of tool wear and improve its prediction accuracy for prognostics and health management. This paper presents a data‐driven methodology and a complete tool chain for the inference of precision machining tool wear from fused machine measurements, such as cutting force, power, audio and vibration signals, and quantify the usefulness of each measurement. Indicators of tool wear are extracted from time‐domain signal statistics, frequency‐domain analysis, and time‐frequency domain analysis. Correlation coefficients between the extracted features (indicators) and the tool wear are used to select the most informative features. Principal Component Analysis and Partial Least‐Squares are used to reduce the dimensionality of the feature space. Regression models, including linear regression, support vector regression, Decision tree regression, neural network regression and Gaussian process regression, are used to predict the tool wear using data from a Haas milling machine performing spiral boss face milling. The performance of the regression models based on subsets of sensors validates the preliminary estimates about the saliency of the sensors. The experimental results show that the proposed methods can predict the machine tool wear precisely, with readily available sensor measurements. Neural network and Gaussian process regression were able to achieve good estimates of tool wear at different machine operating conditions. The most informative signal in predicting tool wear was shown to be the vibration signal. Time‐frequency domain features were the most informative features among the combination of features of three domains. In addition, using partial least squares components extracted from the original features of signals led to higher prediction accuracy.

Han, Seulki↗

Eco-driving Profile Optimization by Dynamic Programming for Battery Electric Vehicles

Although full automation has not yet been achieved, automated vehicles are a valid research area. Not only would automated vehicles provide ultimate driver convenience, but they would maximize energy efficiency by eliminating undesired human driving behaviors and optimally controlling the powertrain. From the perspective of control related to energy saving, speed profile optimization is important for improving system efficiency and satisfying passenger demands. This study employs Dynamic Programming (DP) to solve the constrained optimal problem for travel time, distance, and speed limit by exploring all possible control options. The solutions obtained by DP demonstrate consistent control patterns combining four control modes-acceleration, cruising, coasting, and braking, with cruising or coasting being selective depending on the boundary conditions. Further, this study introduces DP-based simulation results and attempts to provide comprehensive interpretations of the optimal policy by analyzing the essential factors that affect the control problem, including boundary conditions, road load, and powertrain characteristics. Based on these interpretations, the control concepts can be explained as the optimal policy selecting the best control option based on system efficiency and boundary conditions. The results of DP are compared with a human-like driver model to show that the optimal speed profiles can effectively reduce energy consumption.

Autonomous vehicles↗

Influence of metal organic framework glasses on thermoelectric properties of AgSb 0.96 Zn 0.04 Te 2 alloy

In recent years, a significant number of chalcogenides-based thermoelectric (TE) materials have been investigated theoretically and experimentally. However, the efficiency of TE materials is often limited by physical and chemical stability issues. Therefore, it is crucial to identify additive materials that can reduce thermal conductivity and improve the efficiency of crystalline TE materials. One well-known approach to lower thermal conductivity is introducing porosity into the material structure, which helps scatter phonon energy. Metal-organic framework (MOF) crystalline materials, known for their porosity and physical and chemical stability, offer unique advantages in TE applications. In this study, we investigate the influence of 20 weight% amorphous Zeolitic Imidazolate Framework (ZIF)-62 to p-type AgSb 0.96 Zn 0.04 Te 2 (ASTZ), a well-known TE material. We synthesized composites, ASTZ, ASTZ-Zn, and ASTZ-Co, by sintering ASTZ with amorphous ZIF-62(Zn) and ZIF-62(Co) respectively. The addition of amorphous ZIF-62(Zn) leads to a significant enhancement in the Seebeck coefficient of ASTZ increasing from 151 µV/K to 229 µV/K at 586K. Moreover, the thermal conductivity of the ASTZ TE materials drops drastically from 0.491 Wm -1 K -1 to around 0.22 Wm -1 K -1 at 623K with the addition of either amorphous ZIF-62(Zn) or ZIF-62(Co). Remarkably, ASTZ containing amorphous ZIF-62(Zn) achieves a maximum thermoelectric figure of merit (zT max ) of approximately 0.078 at 573K, surpassing any MOF-based thermoelectric material reported to date. In conclusion, these findings highlight the potential of amorphous ZIF-62 as an effective additive for enhancing the properties of thermoelectric materials.

36 MATERIALS SCIENCE↗

Community Resilience through Low-Temperature Geothermal Reservoir Thermal Energy Storage

Submitted data include simulations related to underground thermal battery (UTB) simulations described in Modeling and efficiency study of large scale underground thermal battery deployment, presented at GRC, October 2021. The UTB is comprised of a tank of water, a helical heat exchanger in the center of tank and connected to a water source heat pump, and a phase change material (PCM). Compared to a conventional VBGHE, the UTB is designed to be installed at a much shallower depth, therefore, with a cheaper cost. In addition, the GSHP efficiency is improved due to natural convection of water and additional load capacity provided by PCM. The goal of this study is to explore factors that may affect the efficiency of large-scale UTB deployment. The simulations found in this submission relate to the report on UTB deployment.

15 GEOTHERMAL ENERGY↗

Heat load measurements for the PIP-II pHB650 cryomodule

This study presents a brief overview of the 1st and 2nd phases and an in-depth analysis of the 3rd phase heat load testing performed on the pHB650 (prototype High Beta 650 MHz) cryomodule at PIP2IT (PIP-II Injector Test Facility), with a focus on both the results and the methodological advancements that have improved testing efficiency and accuracy. A key challenge identified in the testing campaign is the higher-than-expected heat loads observed in the first PIP-II (Proton Improvement Plan II) prototype cryomodules (pSSR1 and pHB650) tested at PIP2IT. Elevated heat loads are concerning given the fixed capacity of the PIP-II cryoplant that is currently being installed at Fermilab. However, understanding the sources of these elevated heat loads offers a critical opportunity to implement effective heat load mitigations on upcoming PIP-II cryomodules to stay within the available capacity of the PIP-II cryoplant. The study includes a summary of test results, descriptions of measurement procedures, and key observations on parameters directly and indirectly related to heat load measurements. Direct observations include measured heat loads and the effectiveness of JT heat exchanger under varying conditions, while indirect observation analyze factors such as the temperature distribution on the two-phase pipe and relief piping under varying conditions. Thermal acoustic oscillations (TAO) were identified during testing, which was mitigated by replacing the original G10 stem with a stainless steel stem equipped with wipers for the cryomodule cooldown valve. A major innovation during pHB650 Phase 3 testing was the development of an automated Python script to streamline data acquisition, analysis, and reporting of heat load results. This script automatically retrieved data from ACNET (Accelerator Control Network), performed heat load calculations, and generated detailed reports featuring plots and tables. This advancement significantly reduced manual labor and enhanced the thoroughness of data analysis compared to earlier campaigns. The heat load test reports were promptly uploaded to the electronic logbook shortly after each test, enabling rapid feedback and collaboration between the SRF and cryogenic teams. The heat load measurements included various components: HTTS (high-temperature thermal shield), LTTS (low-temperature thermal shield), 2K isothermal and non-isothermal heat loads. Results were recorded both within the cryomodule and between the bayonet can supply and return. Measurements were conducted under different operating conditions such as "standard", "linac", and "simulated dynamic". Additionally, HTTS and LTTS heat loads were calculated in real time, allowing for the tracking of thermal stability and identification of changes during testing, both in steady-state and transient conditions. The results of this testing campaign not only provide valuable insights into the performance of the pHB650 cryomodule but also highlight best practices and lessons learned that will inform future cryomodule testing at PIP2IT. These include adopting automated tools for data analysis, refining real-time measurement capabilities, and emphasizing detailed pre-test planning. The framework established in this campaign aims to set an improved standard for cryomodule testing and heat load reporting in future cryomodule test campaigns.

Porwisiak, D. [Fermilab; Wroclaw Tech. U.]↗

Energy and power quality measurement for electrical distribution in AC and DC microgrid buildings

Today's selection of DC microgrid buildings features a diverse set of electrical topologies and turnkey solutions, each with specific design trade-offs and optimizations. Designers desperately need standardized metrics and procedures for measurement and verification (M&V) to analyze and compare the advantages of each DC solution to traditional AC building networks. This work develops M&V procedures for quantifying and comparing the energy efficiency and power quality in buildings. To calculate full-building efficiency, this work introduces the measurement-informed modeling method, a procedure that develops and refines a building's energy model with metered data. To quantify power quality, this work defines a new voltage quality index that applies to both AC and DC buildings. This article describes the equipment, instrumentation, and operation necessary to calculate the efficiency and power quality. It then demonstrates these methods with a set of field tests. We report these M&V procedures can ultimately be used to compare and improve the efficiency and power quality of various DC topologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗