Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “doppler”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Application of Positron Doppler Broadening Spectroscopy to the Measurement of the Uniformity of Composite Materials

The uniformity of rubber-carbon black composite materials has been investigated with positron Doppler Broadening Spectroscopy (DBS). The number of grams of carbon black (CB) mixed into one hundred grams of rubber, phr, is used to characterize a sample. A typical concentration for rubber in tires is 50 phr. The S parameter measured by DBS has been found to depend on the phr of the sample as well as the type of rubber and carbon black. The variation in carbon black concentration within a surface area of about 5 mm diameter can be measured by moving a standard Na-22 or Ge-68 positron source over an extended sample. The precision of the concentration measurement depends on the dwell time at a point on the sample. The time required to determine uniformity over an extended sample can be reduced by running with much higher counting rate than is typical in DBS and correcting for the systematic variation of S parameter with counting rate. Variation in CB concentration with mixing time at the level of about 0.5% has been observed.

36 MATERIALS SCIENCE↗

Doppler reflectometer system in the stellarator TJ-II

A Doppler reflectometer system has recently been installed in the stellarator TJ-II. The system is optimized for the Q-band (33-50 GHz) and the high-curvature plasmas produced in TJ-II. The launch angle of the microwave beam can be controlled by a steerable mirror to obtain angles between {+-}20 deg. enabling the measurement of perpendicular wave numbers in the range of 3-15 cm{sup -1}. The available angular range allows for comparisons between positive and negative values and additionally for calibration of the system. Localization and k{sub perpendicular}-estimation is done via the three-dimensional ray/beam-tracing code TRUBA. First measured spectra and radial profiles of the perpendicular velocity of plasma density fluctuations are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect Of Anode Surface on Doppler Profile in Townsend Discharge in Pure Hydrogen

In this work we show results of Monte Carlo modeling of electrons and heavy particles induced spatially resolved emission intensity or the Doppler profile in pure H{sub 2} discharge focusing on anode boundary. In particular we present study of fast H{sub 2} and fast H particles, scattered both at the surface and of the molecules. Since the anode boundary is characterized by a large electron flux, role of electron reflection and production of secondary electrons at the anode surface is part of the complete picture of spatial emission profile. In this work we verify our models of electron backscattering from the anode including both the reflection and the secondary electron production by making comparisons with the drift tube experiments. In order to achieve consistency with our previous results we select conditions of simulation appropriate for very high E/N(E-electric field, N-gas density) that are selected from experimental Townsend discharges in pure H{sub 2}.

74 ATOMIC AND MOLECULAR PHYSICS↗

Accuracy and precision in photonic Doppler velocimetry

While photonic Doppler velocimetry (PDV) is becoming a common diagnostic in dynamic compression research, its limiting accuracy and precision are not well understood. Velocity resolution is known to be inversely proportional to the time resolution, but resolution estimates differ by one to two orders of magnitude. Furthermore, resolution varies with the number of recorded signals and how these signals are analyzed. Numerical simulations reveal factors that affect accuracy and precision in PDV, and the results may be extended to a broad class of measurements. After systematic effects are eliminated, the limiting velocity uncertainty in a PDV measurement is governed by the sampling rate, the signal noise fraction, and the analysis time duration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Doppler coherence imaging and tomography of flows in tokamak plasmas (invited)

This article describes the results of spatial heterodyne Doppler ''coherence imaging'' of carbon ion flows in the divertor region of the DIII-D tokamak. Spatially encoded interferometric projections of doubly ionized carbon emission at 465 nm have been demodulated and tomographically inverted to obtain the spatial distribution of the carbon ion parallel flow and emissivity. The operating principles of the new instruments are described, and the link between measured properties and line integrals of the flow field are established. An iterative simultaneous arithmetic reconstruction procedure is applied to invert the interferometric phase shift projections, and the reconstructed parallel flow field amplitudes are found to be in reasonable agreement with UEDGE modeling.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of window reflections on photonic Doppler velocimetry measurements

Photonic Doppler velocimetry (PDV) has rapidly become a standard diagnostic for measuring velocities in dynamic compression research. While free surface velocity measurements are fairly straightforward, complications occur when PDV is used to measure a dynamically loaded sample through a window. Fresnel reflections can severely affect the velocity and time resolution of PDV measurements, especially for low-velocity transients. Shock experiments of quartz compressed between two sapphire plates demonstrate how optical window reflections cause ringing in the extracted PDV velocity profile. Velocity ringing is significantly reduced by using either a wedge window or an antireflective coating.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Correlation Of Ortho-Positronium Intensity With Doppler Broadening For Rubber Above And Below The Glass Transition Temperature

Previous research has demonstrated a correlation between the Doppler broadening S parameter and the intensity of the ortho-positronium lifetime component in polymers that depends on the composition of the polymer. On the other hand, rubber polymers do not show this correlation and behave more like liquids for which the S parameter is essentially independent of the ortho-positronium intensity. The bubble model has been suggested as an explanation of the lack of correlation in analogy with liquids, but the bubble model applied to rubber is controversial. There are two important differences between the rubber and the polymers samples: first, the rubber samples at room temperature were all above the glass transition temperature (T{sub G}). Second, the rubber samples all contained sulfur and were vulcanized. These differences were investigated by first measuring the S parameter for six rubber samples below T{sub G} where the bubble model would not be expected to work. Second, raw rubber samples that did not contain any sulfur and were unvulcanized were studied at room temperature. The results show that the lack of correlation between the S parameter and the ortho-positronium intensity previously observed for vulcanized rubber is due to the inhibition of positronium formation by the sulfur in the vulcanized rubber samples rather than to the rubber being above T{sub G}.

36 MATERIALS SCIENCE↗

Note: Frequency-conversion photonic Doppler velocimetry with an inverted circulator

Photonic Doppler velocimetry (PDV) is a fiber-based interferometer used in dynamic compression research. Conventional PDV systems are simple to construct but do not perform well in all measurement conditions, while universal PDV systems that support many different configurations are complex and expensive. A simpler approach is the use of external, inverted circulators which can be added and removed in a modular fashion. This technique permits frequency-conversion measurements with a conventional PDV system. Using a correction to remove baseline effects, frequency conversion systems can resolve low velocity transients that conventional PDV cannot.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High resolution ion Doppler spectroscopy at Prairie View Rotamak

A fast ion Doppler spectroscopy (IDS) diagnostic system is installed on the Prairie View Rotamak to measure ion temperature and plasma flow. The diagnostic employs a single channel photomultiplier tube and a Jarrell-Ash 50 monochromator with a diffraction grating line density of 1180 lines/mm, which allows for first order spectra of 200-600 nm. The motorized gear of the monochromator allows spectral resolution of 0.01 nm. Equal IDS measurements are observed for various impurity emission lines of which carbon lines exhibit stronger intensities. Furthermore, the diagnostics is examined in an experiment where plasma experiences sudden disruption and quick recovery. In this case, the IDS measurements show {approx}130% increase in ion temperature. Flow measurements are shown to be consistent with plasma rotation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-resolution spectroscopy for Doppler-broadening ion temperature measurements of implosions at the National Ignition Facility

Future implosion experiments at the national ignition facility (NIF) will endeavor to simultaneously measure electron and ion temperatures with temporal and spatial resolution in order to explore non-equilibrium temperature distributions and their relaxation toward equilibrium. In anticipation of these experiments, and with understanding of the constraints of the NIF facility environment, we have explored the use of Doppler broadening of mid-Z dopant emission lines, such as krypton He-{alpha} at 13 keV, as a diagnostic of time- and potentially space-resolved ion temperature. We have investigated a number of options analytically and with numerical raytracing, and we have identified several promising candidate spectrometer designs that meet the expected requirements of spectral and temporal resolution and data signal-to-noise ratio for gas-filled exploding pusher implosions, while providing maximum flexibility for use on a variety of experiments that potentially include burning plasma.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

2D full wave modeling for a synthetic Doppler backscattering diagnostic

Doppler backscattering (DBS) is a plasma diagnostic used in tokamaks and other magnetic confinement devices to measure the fluctuation level of intermediate wavenumber (k{sub {theta}}{rho}{sub s}{approx} 1) density fluctuations and the lab frame propagation velocity of turbulence. Here, a synthetic DBS diagnostic is described, which has been used for comparisons between measurements in the DIII-D tokamak and predictions from nonlinear gyrokinetic simulations. To estimate the wavenumber range to which a Gaussian beam would be sensitive, a ray tracing code and a 2D finite difference, time domain full wave code are used. Experimental density profiles and magnetic geometry are used along with the experimental antenna and beam characteristics. An example of the effect of the synthetic diagnostic on the output of a nonlinear gyrokinetic simulation is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Precision lifetime measurements of exotic nuclei based on Doppler-shift techniques

A recent progress in precision lifetime measurements of exotic nuclei at the National Superconducting Cyclotron Laboratory (NSCL), Michigan State University is presented. The Recoil Distance Doppler-shift (RDDS) technique has been applied to nuclear reactions involving intermediate-energy rare isotope (RI) beams, to determine absolute transition strengths between nuclear states model independently from level lifetimes of interest. As such an example, recent lifetime measurements of the first 2{sup +} states in the neutron-rich {sup 62,64,66}Fe isotopes at and around N=40 are introduced. The experiment was performed at the Coupled Cyclotron Facility at NSCL using a unique combination of several experimental instruments; the Segmented Germanium Array (SeGA), the plunger device, and the S800 spectrograph. The reduced E2 transition probabilities B(E2) are determined directly from the measured lifetimes. The observed trend of B(E2) clearly demonstrates that an enhanced collectivity persists in {sup 66}Fe despite the harmonic-oscillator magic number N=40. The present results are also discussed in comparison with the large-scale shell model calculations, pointing to a possible extension of the deformation region beyond N=40.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multi-channel Doppler backscattering measurements in the C-2 field reversed configuration

A versatile heterodyne Doppler Backscattering (DBS) system is used to measure density fluctuation levels (in the wavenumber range kρ{sub s} ≤ 50), and the toroidal E × B flow velocity in the C-2 Field-Reversed Configuration (FRC). Six tunable frequencies in three waveguide bands (26 GHz ≤ f ≤ 90 GHz) are launched using monostatic beam optics, via a quasi-optical beam combiner/polarizer and an adjustable parabolic focusing mirror (inside the vacuum enclosure) achieving Gaussian beam spot sizes of 3–5.5 cm at the X/O-mode cutoff. The DBS system covers plasma densities of 0.8 × 10{sup 13} ≤ n{sub e} ≤ 1 × 10{sup 14} cm{sup −3}, and provides access to the FRC core (up to the field null) and across the FRC separatrix into the scrape-off layer plasma.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Doppler shift measurement of Balmer-alpha line spectrum emission from a plasma in a negative hydrogen ion source

Balmer-α light emission from the extraction region of the LHD one-third ion source has shown a characteristic Doppler broadening in the wavelength spectrum detected by a high resolution spectrometer. The spectrum resembles Gaussian distribution near the wavelength of the intensity peak, while it has an additional component of a broader foot. The measured broadening near the wavelength of the intensity peak corresponds to 0.6 eV hydrogen atom temperature. The spectrum exhibits a larger expansion in the blue wing which becomes smaller when the line of sight is tilted toward the driver region from the original observation axis parallel to the plasma grid. A surface collision simulation model predicts the possibility of hydrogen reflection at the plasma grid surface to form a broad Balmer-α light emission spectrum.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Velocity space evolution of a minority energetic electron population undergoing the anomalous Doppler instability

The kinetic evolution in velocity space of a minority suprathermal electron population that is undergoing the anomalous Doppler instability (ADI) is investigated using the results from fully nonlinear numerical simulations that self-consistently evolve particles and fields in a plasma. Electron trajectories in phase space during different stages of the ADI are captured, and are analysed in relation to the characteristics of the excited electric fields and of the overall distribution of particles. For some electrons, trapping and mirroring effects are observed during the saturation phase. A relationship between the second order moments of the perpendicular electron distribution function and time is established, and is used to investigate the range of applicability of analytical approximations drawn from classical theory, that involve a quasilinear wave-driven diffusion operator.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of Doppler-shifted photons on subnanosecond breakdown in high-voltage pulse discharge

The experiments in high-voltage open discharge in helium [1, 2] showed a controlled current growth rate of 500 A/(cm{sup 2}ns) for an applied voltage of 20 kV and gas pressure of 6 Torr. A kinetic model of the subnanosecond breakdown is developed to analyze the mechanism of current growth, which takes into account the kinetics of electrons, ions, fast atoms and photons with a Doppler shift (DS). DS photons appear in discharge due to collisions of heavy particles. Using particle in cell simulations, we show a critical role of DS photons in the electron emission from the cathode during the breakdown. Our experimental and calculation results show a decrease of the breakdown time with increasing gas pressure from 3 Torr to 16 Torr.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Preliminary measurements of the edge magnetic field pitch from 2-D Doppler backscattering in MAST and NSTX-U (invited)

The Synthetic Aperture Microwave Imaging (SAMI) system is a novel diagnostic consisting of an array of 8 independently phased antennas. At any one time, SAMI operates at one of the 16 frequencies in the range 10-34.5 GHz. The imaging beam is steered in software post-shot to create a picture of the entire emission surface. In SAMI’s active probing mode of operation, the plasma edge is illuminated with a monochromatic source and SAMI reconstructs an image of the Doppler back-scattered (DBS) signal. By assuming that density fluctuations are extended along magnetic field lines, and knowing that the strongest back-scattered signals are directed perpendicular to the density fluctuations, SAMI’s 2-D DBS imaging capability can be used to measure the pitch of the edge magnetic field. In this paper, we present preliminary pitch angle measurements obtained by SAMI on the Mega Amp Spherical Tokamak (MAST) at Culham Centre for Fusion Energy and on the National Spherical Torus Experiment Upgrade at Princeton Plasma Physics Laboratory. Lastly, the results demonstrate encouraging agreement between SAMI and other independent measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simple new methods for deducing lifetimes in recoil distance Doppler-shift measurements

In this work, new approaches for lifetime determination using data from recoil distance Doppler-shift experiments are presented based on the fundamental properties of the functions describing the time evolution of the population of excited nuclear states. To some extent, one of them represents a contraction of the well-known Differential decay-curve method (DDCM) by using the most reliable data point [the maximum of the $n_i(t)$ function describing the population of level $\textit{i}$ in time] and a purely numerical procedure avoiding any fitting of decay curves. The combination with the standard DDCM analysis is promising for improving the reliability and the precision of the results for the lifetimes obtained. The novel part of the approach consists of using a chain of equations at the consecutive maxima of the ni(t) functions, which allow us to precisely determine the ratio of the lifetimes of two consecutive levels and, in the case where one of these lifetimes is known, to determine the unknown one. In addition, a simple integral derivation of the lifetime is presented involving the peak areas measured at different distances, and an application of the first moments (expectation values and centroids in time) of the $n_i(t)$ functions for determining lifetimes is also demonstrated to be useful.

47 OTHER INSTRUMENTATION↗