Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “display”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Polymer Cholesteric-Liquid-Crystal (PCLC) Flake/Fluid Host Electro-Optical Suspensions and Their Applications in Color Flexible Reflective Displays

Polymer cholesteric-liquid-crystal (PCLC) flake/fluid-host suspensions are a novel particle display technology for full-color reflective display applications on rigid or flexible substrates. These “polarizing pigments” require no polarizers or color filters, switch rapidly at very low voltages, and produce highly saturated colors with a reflection efficiency approaching 80%.

36 MATERIALS SCIENCE↗

Doped Multilayer Polymer Cholesteric-Liquid-Crystal (PCLC) Flakes: A Novel Electro-Optical Medium for Highly Reflective Color Flexible Displays

Polymer cholesteric-liquid-crystal (PCLC) flake/fluid-host suspensions are a novel particle display technology for full-color reflective display applications on rigid or flexible substrates. These “polarizing pigments” require no polarizers or color filters, switch rapidly at very low voltages, and produce highly saturated colors with a reflection efficiency approaching 80%.

36 MATERIALS SCIENCE↗

Construction and Screening of Antigen Targeted Immune Yeast Surface Display Antibody Libraries

These protocols describe a yeast surface display-based process for the rapid selection of antibodies from immunized mice, eliminating the need for creating and screening hybridoma fusions. A yeast surface display library of single-chain antibody fragments (scFvs) is created from antigen-binding B cells from the splenocytes of immunized mice. The antigen targeted library is then screened for antigen specific scFv by magneticactivated cell sorting (MACS) and fluorescence-activated cell sorting (FACS). Library construction and screening can be accomplished in as little as 2 weeks, resulting in a panel of scFvs specific for the target antigen.

60 APPLIED LIFE SCIENCES↗

Realizing Wide-Gamut Human-Centric Display Lighting with K 3 AlP 3 O 9 N:Eu 2+

Abstract Computers, televisions, and smartphones are revolutionized by the invention of InGaN blue light-emitting diode (LED) backlighting. Yet, continual exposure to the intense blue LED emission from these modern displays can cause insomnia and mood disorders. Developing “human-centric” backlighting that uses a violet-emitting LED chip and a trichromatic phosphor mixture to generate color images is one approach that addresses this problem. The challenge is finding a blue-emitting phosphor that possesses a sufficiently small Stokes’ shift to efficiently down-convert violet LED light and produce a narrow blue emission. This work reports a new oxynitride phosphor that meets this demand. K 3 AlP 3 O 9 N:Eu 2+ exhibits an unexpectedly narrow (45 nm, 2206 cm -1 ), thermally robust, and efficient blue photoluminescence upon violet excitation. Computational modeling and temperature-dependent optical property measurements reveal that the narrow emission arises from a rare combination of preferential excitation and site-selective quenching. The resulting chromaticity coordinates of K 3 AlP 3 O 9 N:Eu 2+ lie closer to the vertex of the Rec. 2020 than a blue LED chip and provides access to ≈10% more colors than a commercial tablet when combined with commercial red- and green-emitting phosphors. Alongside the wide gamut, tuning the emission from the violet LED and phosphor blend can reduce blue light emissions to produce next-generation, human-centric displays.

36 MATERIALS SCIENCE↗

Blocking peptides against HBV: PreS1 protein selected from a phage display library

Highlights: {yields} Successfully selected specific PreS1-interacting peptides by using phage displayed library. {yields} Alignment of the positive phage clones revealed a consensus PreS1 binding motif. {yields} A highly enriched peptide named P7 had a strong binding ability for PreS1. {yields} P7 could block PreS1 attachment. -- Abstract: The PreS1 protein is present on the outermost part of the hepatitis B virus (HBV) surface and has been shown to have a pivotal function in viral infectivity and assembly. The development of reagents with high affinity and specificity for PreS1 is of great significance for early diagnosis and treatment of HBV infection. A phage display library of dodecapeptide was screened for interactions with purified PreS1 protein. Alignment of the positive phage clones revealed a putative consensus PreS1 binding motif of HX{sub n}HX{sub m}HP/R. Moreover, a peptide named P7 (KHMHWHPPALNT) was highly enriched and occurred with a surprisingly high frequency of 72%. A thermodynamic study revealed that P7 has a higher binding affinity to PreS1 than the other peptides. Furthermore, P7 was able to abrogate the binding of HBV virions to the PreS1 antibody, suggesting that P7 covers key functional sites on the native PreS1 protein. This newly isolated peptide may, therefore, be a new therapeutic candidate for the treatment of HBV. The consensus motif could be modified to deliver imaging, diagnostic, and therapeutic agents to tissues affected by HBV.

60 APPLIED LIFE SCIENCES↗

Identification of a novel aFGF-binding peptide with anti-tumor effect on breast cancer from phage display library

Highlights: • A specific aFGF-binding peptide AP8 was identified from a phage display library. • AP8 could inhibit aFGF-stimulated cell proliferation in a dose-dependent manner. • AP8 arrested the cell cycle at the G0/G1 phase by suppressing Cyclin D1. • AP8 could block the activation of Erk1/2 and Akt kinase. • AP8 counteracted proliferation and cell cycle via influencing PA2G4 and PCNA. - Abstract: It has been reported that acidic fibroblast growth factor (aFGF) is expressed in breast cancer and via interactions with fibroblast growth factor receptors (FGFRs) to promote the stage and grade of the disease. Thus, aFGF/FGFRs have been considered essential targets in breast cancer therapy. We identified a specific aFGF-binding peptide (AGNWTPI, named AP8) from a phage display heptapeptide library with aFGF after four rounds of biopanning. The peptide AP8 contained two (TP) amino acids identical and showed high homology to the peptides of the 182–188 (GTPNPTL) site of high-affinity aFGF receptor FGFR1. Functional analyses indicated that AP8 specifically competed with the corresponding phage clone A8 for binding to aFGF. In addition, AP8 could inhibit aFGF-stimulated cell proliferation, arrested the cell cycle at the G0/G1 phase by increasing PA2G4 and suppressing Cyclin D1 and PCNA, and blocked the aFGF-induced activation of Erk1/2 and Akt kinase in both breast cancer cells and vascular endothelial cells. Therefore, these results indicate that peptide AP8, acting as an aFGF antagonist, is a promising therapeutic agent for the treatment of breast cancer.

60 APPLIED LIFE SCIENCES↗

Mucosal vaccination by adenoviruses displaying reovirus sigma 1

We developed adenovirus serotype 5 (Ad5) vectors displaying the sigma 1 protein from reovirus as mucosal vaccines. Ad5-sigma retargets to JAM-1 and sialic acid, but has 40-fold reduced gene delivery when compared to Ad5. While weaker at transduction, Ad5-sigma generates stronger T cell responses than Ad5 when used for mucosal immunization. In this work, new Ad5-fiber-sigma vectors were generated by varying the number of fiber β-spiral shaft repeats (R) between the fiber tail and sigma. Increasing chimera length led to decreasing insertion of these proteinsAd5 virions. Ad-R3 and R14 vectors effectively targeted JAM-1 in vitro while R20 did not. When wereused to immunize mice by the intranasal route, Ad5-R3-sigma produced higher serum and vaginal antibody responses than Ad5. These data suggest optimized Ad-sigma vectors may be useful vectors for mucosal vaccination. - Highlights: • Constructed adenoviruses (Ads) displaying different reovirus sigma 1 fusion proteins. • Progressively longer chimeras were more poorly encapsidated onto Ad virions. • Ad5-R3-sigma mediated better systemic and mucosal immune responses than Ad5.

60 APPLIED LIFE SCIENCES↗

Screening a phage display library for a novel FGF8b-binding peptide with anti-tumor effect on prostate cancer

Fibroblast growth factor 8b (FGF8b) is the major isoform of FGF8 expressed in prostate cancer and it correlates with the stage and grade of the disease. FGF8b has been considered as a potential target for prostate cancer therapy. Here we isolated 12 specific FGF8b-binding phage clones by screening a phage display heptapeptide library with FGF8b. The peptide (HSQAAVP, named as P12) corresponding to one of these clones showed high homology to the immunoglobulin-like (Ig-like) domain II(D2) of high-affinity FGF8b receptor (FGFR3c), contained 3 identical amino acids (AVP) to the authentic FGFR3 D2 sequence aa 163–169 (LLAVPAA) directly participating in ligand binding, carried the same charges as its corresponding motif (aa163–169) in FGFR3c, suggesting that P12 may have a greater potential to interrupt FGF8b binding to its receptors than other identified heptapeptides do. Functional analysis indicated that synthetic P12 peptides mediate significant inhibition of FGF8b-induced cell proliferation, arrest cell cycle at the G0/G1 phase via suppression of Cyclin D1 and PCNA, and blockade of the activations of Erk1/2 and Akt cascades in both prostate cancer cells and vascular endothelial cells. The results demonstrated that the P12 peptide acting as an FGF8b antagonist may have therapeutic potential in prostate cancer. - Highlights: ► A novel FGF8b-binding peptide P12 was isolated from a phage display library. ► The mechanisms for P12 peptide inhibiting cell proliferation were proposed. ► P12 caused cell cycle arrest at G0/G1 phase via suppression of Cyclin D1 and PCNA. ► P12 suppressed FGF8b-induced activations of Akt and MAP kinases. ► P12 acting as an FGF8b antagonist may have therapeutic potential in prostate cancer.

60 APPLIED LIFE SCIENCES↗

ENVIRONMENTAL REVIEWS AND CASE STUDIES: Addressing the Public Outreach Responsibilities of the National Historic Preservation Act: Argonne National Laboratory’s Box Digital Display Platform

Federal agencies are made responsible for managing the historic properties under their jurisdiction by the National Historic Preservation Act of 1966, as amended. A component of this responsibility is to mitigate the effect of a federal undertaking on historic properties through mitigation often through documentation. Providing public access to this documentation has always been a challenge. To address the issue of public access to mitigation information, personnel from Argonne National Laboratory created the Box Digital Display Platform, a system for communicating information about historic properties to the public. The platform, developed for the US Army Dugway Proving Ground, uses short introductory videos to present a topic but can also incorporate photos, drawings, GIS information, and documents. The system operates from a small, self-contained computer that can be attached to any digital monitor via an HDMI cable. The system relies on web-based software that allows the information to be republished as a touch-screen device application or as a website. The system does not connect to the Internet, and this increases security and eliminates the software maintenance fees associated with websites. The platform is designed to incorporate the products of past documentation to make this information more accessible to the public; specifically those documentations developed using the Historic American Building Survey/ Historic American Engineering Record (HABS/HAER) standards. Argonne National Laboratory’s Box Digital Display Platform can assist federal agencies in complying with the requirements of the National Historic Preservation Act. Environmental Practice 18: 209–213 (2016)

54 ENVIRONMENTAL SCIENCES↗

Using phage display for rational engineering of a higher-affinity humanized 3’ phosphohistidine-specific antibody

Abstract Histidine phosphorylation is a non-canonical post-translational modification (PTM), with 1-phosphohistidine (1-pHis) and 3-phosphohistidine (3-pHis) isoforms, that is understudied due to a lack of robust reagents, including high-affinity pHis-specific antibodies. Engineering pHis antibodies is challenging due to the labile nature of its phosphoramidate (P-N) bond. We developed a strategy for in vitro engineering of antibodies for the detection of native 3-pHis targets, in which the rabbit SC44-8 anti-3-pTza mAb is humanized into a scaffold (hSC44) that is suitable for phage display. Six unique Fab phage-displayed hSC44 scaffold libraries were screened for antibodies that bound 3-pHis with higher affinity and had specificity for 3-pHis versus 3-pTza. hSC44.20N32F L , the best engineered antibody, has ~10-fold higher affinity for 3-pHis than parental hSC44. Eleven new Fab structures, including the first antibody-pHis peptide structures, together with structural and quantum mechanical calculations, provided molecular insights into 3-pHis and 3-pTza discrimination by hSC44.20N32F L and the increased affinity obtained through engineering. We demonstrated the utility of these high-affinity 3-pHis-specific antibodies for the recognition of pHis proteins in mammalian cells by immunoblotting and immunofluorescence staining. Our work describes a general method for engineering labile PTM-specific antibodies and provides novel antibodies for investigating the role of 3-pHis in cell biology.

Martyn, Gregory D.↗

The effect of a Si-doped protective layer on the discharge characteristics of an alternating current plasma display panel

In order to improve the discharge characteristics such as discharge voltage, luminance, luminous efficacy, high-temperature misfiring, and lifetime, a small amount of Si was added to the MgO protective layer of a plasma display panel. The MgO protective layers were deposited by using an electron-beam evaporation method. The addition of Si onto a MgO protective layer can effectively increase the secondary electron emission coefficient so as to improve the discharge characteristics compared with using a pure MgO film. Both the surface characteristics of the protective layer and the electro-optical properties of 4 in. test panels were investigated, such as the discharge voltage, luminance, luminous efficacy, high-temperature misfiring, and lifetime. The results show that Si doping of 0.03%-0.04% in MgO has the best performance on plasma display panels.

36 MATERIALS SCIENCE↗

Mechanism of high luminous efficacy in plasma display panel with high secondary electron emission coefficient cathode material analyzed through three-dimensional fluid model simulation

The mechanism to realize high luminous efficacy in a plasma display panel fabricated with a cathode material possessing a high secondary electron emission coefficient ({gamma}) for Ne and Xe ions was studied via three-dimensional numerical simulation. When a high {gamma} cathode material is used, the increased electron heating efficacy is responsible for increasing vacuum ultraviolet (VUV) efficacy with 10% Xe content gas. However, the continued availability of sufficient secondary electrons during the dynamic moving phase of the cathode sheath in which the electric field remains weakened causes increasing VUV efficacy with 30% Xe content gas. It was found that the improvement of the luminous efficacy of the plasma display panel with a high {gamma} cathode material is maximized under the condition of high Xe content gas because of the simultaneous increase of the electron heating efficacy and Xe excitation efficacy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Lowering of the firing voltage and reducing of the discharge delay time in alternating current plasma display panels by a discontinuous spin-coated LaB{sub 6} film on the MgO protective layer

A spin coated LaB{sub 6} discontinuous film is covered on MgO protective layer to improve the discharge performance of alternating current plasma display panels. Under the premise of high transmittance of more than 90%, a very small amount of polycrystal LaB{sub 6} powders added in an organic solvent are chosen as the coating solution. The discharge characteristics results show that with 250 torr 5% Xe-Ne pressure, the firing voltage and discharge delay time of the test panel with LaB{sub 6}/MgO double protective layer are decreased by 13.4% and 36.5%, respectively, compared with that of conventional MgO protective layer, likely owing to the low work function of LaB{sub 6.} Furthermore, the aging time of the proposed structure is comparable to that of pure MgO protective layer. Therefore, it will not increase the production costs and is highly suitable to be applied for alternating current plasma display panels with low electrical power consumption.

36 MATERIALS SCIENCE↗

A seamless acquisition digital storage oscilloscope with three-dimensional waveform display

In traditional digital storage oscilloscope (DSO), sampled data need to be processed after each acquisition. During data processing, the acquisition is stopped and oscilloscope is blind to the input signal. Thus, this duration is called dead time. With the rapid development of modern electronic systems, the effect of infrequent events becomes significant. To capture these occasional events in shorter time, dead time in traditional DSO that causes the loss of measured signal needs to be reduced or even eliminated. In this paper, a seamless acquisition oscilloscope without dead time is proposed. In this oscilloscope, three-dimensional waveform mapping (TWM) technique, which converts sampled data to displayed waveform, is proposed. With this technique, not only the process speed is improved, but also the probability information of waveform is displayed with different brightness. Thus, a three-dimensional waveform is shown to the user. To reduce processing time further, parallel TWM which processes several sampled points simultaneously, and dual-port random access memory based pipelining technique which can process one sampling point in one clock period are proposed. Furthermore, two DDR3 (Double-Data-Rate Three Synchronous Dynamic Random Access Memory) are used for storing sampled data alternately, thus the acquisition can continue during data processing. Therefore, the dead time of DSO is eliminated. In addition, a double-pulse test method is adopted to test the waveform capturing rate (WCR) of the oscilloscope and a combined pulse test method is employed to evaluate the oscilloscope's capture ability comprehensively. The experiment results show that the WCR of the designed oscilloscope is 6 250 000 wfms/s (waveforms per second), the highest value in all existing oscilloscopes. The testing results also prove that there is no dead time in our oscilloscope, thus realizing the seamless acquisition.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Transmission integral analysis of Mössbauer spectra displaying hyperfine parameter distributions with arbitrary profile

Accurate quantitative analysis of Mössbauer spectra displaying thickness effects requires the consideration of the so-called transmission integral when modeling the spectral shape. Whereas this is straightforward when the correct model for the decomposition of the absorber's nuclear resonance absorption cross-section into individual components is a priori known, in the absence of such knowledge and notably in the presence of hyperfine parameter distributions with an unknown profile, the so-called model-independent evaluation methods could be used to fit the spectra. However, the methods available for this purpose were developed for the analysis of spectra for which the thin absorber approximation is valid, and thus they do not take the sample thickness and related effects into account. Consequently, in order to use them for spectra displaying thickness effects, their usage needs to be generalized by combining them with transmission integral fitting. A new algorithm realizing such a generalized version of the Hesse-Rübartsch model-independent evaluation method was developed recently as an integral part of the MossWinn program. In the present work, the working principle of the newly developed algorithm is described in details along with examples illustrating the capabilities of the method for the case of {sup 57}Fe Mössbauer spectroscopy.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Study of virtual displays based on raster optical elements

The paper is devoted to the study of the ultimate resolution of virtual displays with raster systems. Raster systems in such displays are used for an essential reduction of their longitudinal overall dimensions. Three schemes are considered: in the first one each element of the raster system forms an image of one pixel only, in the second one each element of the raster system forms a small part of a virtual image, the third scheme is analogous to the first one, but is implemented in the form of a contact lens. For each scheme, we analyse the overall dimensions of the optical system and the characteristics of the virtual image, i.e., the ultimate resolution and the nonuniformity of its illumination. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

iSpy: A powerful and lightweight event display

iSpy is a general-purpose event data and detector visualization program that was developed as an event display for the CMS experiment at the LHC and has seen use by the general public and teachers and students in the context of education and outreach. Central to the iSpy design philosophy is ease of installation, use, and extensibility. The application itself uses the open-access packages Qt4 and Open Inventor and is distributed either as a fully-bound executable or a standard installer package: one can simply download and double-click to begin. Mac OSX, Linux, and Windows are supported. iSpy renders the standard 2D, 3D, and tabular views, and the architecture allows for a generic approach to production of new views and projections. iSpy reads and displays data in the ig format: event information is written in compressed JSON format files designed for distribution over a network. This format is easily extensible and makes the iSpy client indifferent to the original input data source. The ig format is the one used for release of approved CMS data to the public.

Alverson, G.↗

SU-E-J-262: Segmentation in Therapy: Impact of Display

Purpose: To determine the calibration of monitors used for structure delineation in radiotherapy and to investigate the impact of window/level on the delineations. Method and Materials: hotometers were used to measure ambient light and luminance for 12 monitors used for delineating structures in radiotherapy. Luminance was determined using AAPM TG-18 patterns TG18-LN12-01 to TG18-LN12-18. The DICOM grayscale display function (GSDF) was calculated for each monitor. To investigate the impact of window and level eight observers each outlined two sets of structures (four structures per set) on CT simulation images. In the first set window and level were initialized at random values and the observers adjusted as needed. In the second set window and level were locked at preselected values for all observers. Results: Ambient light variability at different displays was 24% and was higher than radiology reading rooms. Monitor luminance curves were substantially different than the corresponding GSDF. Monitors demonstrated higher contrast than the GSDF in the lower third of driving levels and lower contrast in the upper third of driving levels. Increased contrast at low driving levels may be to compensate for high ambient light which would otherwise reduce contrast. Abrupt changes in luminance and loss of all contrast at both upper and lower driving levels was observed. Interobserver variability was 379HU for window and 217HU for level. Outline variability was lower when the window and level settings were similar and when they were preselected. Structures without sharp boundaries (e.g., partial volume and a wide window value) resulted in substantial interobserver variability even when window/level were preselected. Conclusion: Substantial variation in monitor calibration and ambient light exists in radiotherapy. Further, the substantially different window/level contributes to outline variability. Future work will quantify the contributions of monitor calibration and window/level on outline variability and accuracy.

60 APPLIED LIFE SCIENCES↗