Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “deviated”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Conformational diversity of 1-phenylpiperidin-4-one in the gas phase

Conformational preferences of substituted, saturated cyclic ketones may deviate from those of their parent analogues. 1-Phenylpiperidin-4-one was found to exist in several forms differing by not only position (axial or equatorial) of the aryl-substituent but also by a configuration of the piperidine cycle itself: chair-Eq, chair-Ax and twist-Tw. Here, the ratios of the co-existing species contributions in gas phase predicted by various quantum chemical calculations were confirmed by synchronous gas-phase electron diffraction and mass spectrometric experiments carried out for the vapor at 337 K demonstrating a best fit with the B3LYP-D3/cc-pVTZ combination: Eq:Ax:Tw=55(13):22(9):23(10) vs. 40:35:25.

1-phenylpiperidin-4-one↗

Reproducibility of calculations on Li species with correlation-consistent basis sets

Here we have found that two different basis set series, both labeled cc-pVxZ, are widely available and widely used for calculation on Li compounds such that calculations that should be the same are different, causing a reproducibility problem. Here we study the magnitude of the disagreement of these nominally-the-same basis sets for wave function and density functional calculations of Li clusters. We find deviations among the basis sets of as large as 22 millihartrees. In most cases one obtains lower energies with the noncanonical choices. Therefore, it is important to specify which version of the basis set is used for calculations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Computational and experimental study of different brines in temperature swing solvent extraction desalination with amine solvents

Rapid global urbanization and high-salinity wastewater disposal from industrial activities have exerted significant pressure on water resources. Over the past few years, temperature swing solvent extraction (TSSE) has been identified as a promising technique to desalinate hypersaline brines. Despite its potential, the TSSE desalination literature has been mainly based on empirical insights, and the limited molecular simulation studies have primarily focused on NaCl brines. Herein, we use molecular dynamics (MD) simulations to study the TSSE desalination of four different brines, namely, KCl, KBr, NaCl, and NaBr using diisopropylamine as the solvent. Based on both bulk and interfacial brine-diisopropylamine MD results, here we investigate the qualitative and quantitative performance of the simulations by benchmarking these results against our experimental evaluations of these same systems. MD results provide satisfactory qualitative agreement with the experimental data of water solubilization in the organic phase and amine solubilization in the aqueous phase for the KBr, KCl, and NaBr brines. Also, the molecular mechanism of solvation of ionic species by water molecules over diisopropylamine suggested by the MD simulations is in agreement with our experimental data. However, larger qualitative and quantitative deviations were observed for the NaCl brines, and this is likely due to polarization and charge transfer effects, as quantified by our quantum chemical calculations.

42 ENGINEERING↗

Generating realistic building electrical load profiles through the Generative Adversarial Network (GAN)

Building electrical load profiles can improve understanding of building energy efficiency, demand flexibility, and building-grid interactions. Current approaches to generating load profiles are time-consuming and not capable of reflecting the dynamic and stochastic behaviors of real buildings; some approaches also trigger data privacy concerns. In this study, we proposed a novel approach for generating realistic electrical load profiles of buildings through the Generative Adversarial Network (GAN), a machine learning technique that is capable of revealing an unknown probability distribution purely from data. The proposed approach has three main steps: (1) normalizing the daily 24-hour load profiles, (2) clustering the daily load profiles with the k-means algorithm, and (3) using GAN to generate daily load profiles for each cluster. The approach was tested with an open-source database – the Building Data Genome Project. We validated the proposed method by comparing the mean, standard deviation, and distribution of key parameters of the generated load profiles with those of the real ones. The KL divergence of the generated and real load profiles are within 0.3 for majority of parameters and clusters. Additionally, results showed the load profiles generated by GAN can capture not only the general trend but also the random variations of the actual electrical loads in buildings. We report the proposed GAN approach can be used to generate building electrical load profiles, verify other load profile generation models, detect changes to load profiles, and more importantly, anonymize smart meter data for sharing, to support research and applications of grid-interactive efficient buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Large-scale simulation-based parametric analysis of an optimal precooling strategy for demand flexibility in a commercial office building

Achieving success with grid-interactive efficient buildings (GEBs) is closely tied to the utilization of flexible loads. A valuable strategy involves the implementation of precooling techniques before high-demand events, such as peak hours, by adjusting zone air temperature setpoints. This leads to a reduction in thermal loads and peak electricity demand during these times, as the building’s thermal mass stores and subsequently releases thermal energy. However, the effectiveness of the pre-cooling optimization is highly contingent on specific conditions such as building thermal properties, weather conditions, utility rate structure, HVAC equipment sizing, etc. Therefore, investigating the impacts of these condition-specific factors is crucial, especially when considering precooling strategies that utilize thermal mass in commercial buildings. In this paper, we first devised a novel heuristic control approach that incorporates parameterized optimal precooling thermostat schedules to enhance demand flexibility in a commercial office building. Subsequently, we conducted a thorough performance evaluation of this control strategy. Here, the optimal thermostat schedule was parameterized using three optimization variables: the precooling start time, the precooling end time, and the precooling temperature setpoint. Utilizing the DOE medium-sized office building as the virtual testbed, we showed that the parameterized schedule effectively approximates model predictive control and requires drastically reduced computational overhead. In addition, we investigated the impact of different influencing factors on the optimal precooling strategy. These factors include building thermal mass, outdoor air conditions, and energy price profiles. Using high-performance computing, we simulated a total of 225 scenarios, consisting of three levels of thermal mass, five typical outdoor air temperature profiles, and fifteen time-of-use price plans. The results demonstrate that optimal thermostat scheduling could save substantial energy cost in medium-sized office buildings with heavy thermal mass but with some energy penalty. Although the potential for cost savings is lower in buildings with low and medium thermal mass, the energy penalty remains consistent in all three thermal mass scenarios. The study also highlights the need to account for zone diversity and recognize that a one-size-fits-all-zone setpoint schedule may not be suitable for all zones and can lead to unnecessary energy wastage. Furthermore, the results highlight that while outdoor air conditions play a role in cost and energy performance, the cooling load exerts a more immediate and substantial influence on cost savings in precooling strategies. Although cost savings are comparable under certain conditions with the same cooling load, observed deviations in energy penalty indicate potential disparities in the efficiency of the HVAC system during the load-shifting process. In addition, the duration of peak pricing and the ratio between peak and off-peak times exhibit clear correlations with cost savings and energy consumption, aligning with intuitive expectations. These findings offer valuable insights for optimizing precooling strategies in office buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Commercial building HVAC demand flexibility with model predictive control: Field demonstration and literature insights

Model Predictive Control (MPC) for building Heating Ventilation and Air Conditioning (HVAC) systems is beginning to gain traction in the market, with a few controls companies incorporating it into their product offerings. However, it remains difficult to assess whether the energy cost savings are enough to justify the cost of MPC implementation for a particular building, given the limited number of reported demonstrations. For small commercial and residential buildings with relatively uniform systems, standardized approaches can help lower implementation costs. In contrast, for large buildings or district systems, the potential magnitude of cost savings could justify more customized solutions. Estimating the cost-effectiveness of MPC becomes more challenging for medium and large commercial buildings, where a one-size-fits-all solution may not be suitable, and the potential energy cost savings may be insufficient to justify a customized solution. To make MPC technology more appealing, incorporating additional value streams beyond energy efficiency alone can significantly increase its attractiveness. One such revenue stream is demand flexibility, in response to dynamic electricity prices, where MPC can leverage the thermal mass of the building to shift the load and support the grid. Building on an extensive literature review of MPC field studies focused on cost savings and demand flexibility, this paper presents the results of implementing MPC control in a large office building HVAC system in Berkeley, CA. Four different dynamic electricity price profiles were integrated into the MPC objective function to shift building demand while maintaining comfort, and field testing was performed with each price profile across four seasons. The results show potential for 40–65 % demand decrease percentage and up to 61 % annual cost savings compared to the existing rule-based control strategy, under the tested dynamic price scenarios. This paper also presents a sensitivity analysis on the cost savings with respect to the price profile variability, discusses the implementation effort for the price-responsive MPC, and compares the cost savings found in this study to those found in literature on the basis of dynamic price variability, or so-called Electricity Price Relative Standard Deviation.

Zanetti, Ettore↗

Experimental test of model predictive control in a variable air volume system

Model predictive control (MPC) has been widely studied as a promising approach for improving energy efficiency and operational flexibility in buildings, yet its real-world performance for commercial variable air volume (VAV) systems remains insufficiently characterized. In particular, the impacts of model mismatch on control robustness, real-time computational burden, and device-level operation are rarely evaluated using long-term field data. Here, this study presents a comprehensive experimental evaluation of MPC applied to a full-scale VAV system in Oak Ridge National Laboratory’s Flexible Research Platform-2 building with constant cooling/heating temperature setpoints and no occupancy. The study offers three key advantages over existing work: (1) it uses a representative building in a full-scale experimental test, capturing realistic system dynamics and complexity; (2) it evaluates a relatively sophisticated MPC formulation using two different optimization solvers (Gurobi and PSO), fully accounting for computational complexity and methodological diversity; and (3) it systematically assesses potential negative impacts on various building devices, benchmark against a well-established baseline, ASHRAE Guideline 36 (G36). To isolate zone- and air-handling-unit–level supervisory control effects, the supply fan was operated with a fixed static pressure setpoint under all strategies, and the trim-and-response static pressure reset in G36 was not enabled. Results show that MPC maintained thermal comfort while improving energy efficiency. Abrupt solar radiation variations degraded performance. Computation times ranged from ∼1 s (Gurobi) to ∼ 70 s (PSO). Compared with G36, MPC achieves 33% energy savings and reduces median reheat coil output by approximately a factor of 5–10 for a representative cooling day under matched weather conditions. However, it increases the maximum discomfort deviation from 0.5 to 1°C and results in a 32% increase in staging frequency. In addition, PSO-based MPC introduced damper oscillations, also affecting actuator longevity.

ASHRAE guideline 36↗

Design and performance assessment of a dual-mode latent thermal storage integrated heat pump across multiple climate zones

The electrification of space cooling and heating systems risks overloading the existing electrical grid during peak hours. Heat pumps integrated with thermal energy storage (HP-TES) offer a promising solution by shifting peak loads to off-peak hours, reducing grid strains. This work presents the design and assessment of a dual-mode HP-TES that uses a single 22°C phase-change material (PCM) as a heat source or sink in heating and cooling modes, respectively. Performance assessment was conducted using Modelica-based transient models, and full-year simulations were conducted across eight US climate zones using typical weather data. Two HP-TES performance metrics: peak energy reduction and recharge energy increases, were defined by comparing HP-TES energy consumption with base HP peak consumptions. Annual heating demand reductions (40–65%) exceeded cooling demand reductions (15–20%) due to the elimination of peak-hour backup heating. Cooling mode recharge energy requirements (0–10%) were reduced in locations with lower summer nighttime temperatures, while heating recharge requirements were lower than the high base-peak energy demand from backup heating. Simplified rapid methods that were 10 7 times faster than annual simulations were developed to predict seasonal cooling and heating energy reductions, and recharge energy requirements, with maximum deviations of ±2.5% and ±3.5% points. These methods enabled rapid parametric studies that identified optimal location-specific PCM temperatures between 22°C and 27°C, highlighting the need to consider both discharge and recharge energy requirements to achieve sustainable, energy-efficient peak load shifting across various climate zones.

25 ENERGY STORAGE↗

Application of electron backscatter diffraction techniques to quantify effects of aging on sub-grain and spatial heterogeneity in NMC cathodes

Identification and evaluation of structural heterogeneity in spent cathode materials is crucial to developing appropriate remediation strategies for novel recycling processes. Native heterogeneities may be exacerbated during the cell's operational lifetime, as sub-particle-scale variations induce anisotropic expansion and contraction upon cycling. Structural transformations resulting from repeated cycling and calendar aging predominantly occur at the secondary particle surface and at the grain boundaries (GBs) between primary particles. However, the diffusion and stress build up around and across GBs are poorly understood. In this study, electron backscatter diffraction (EBSD) is employed to track sub-grain lattice structure across a statistically relevant number of Li(Ni0.33Mn0.33Co0.33)O2 (NMC-111) particles. Specifically, differences in lattice misorientation – measured as the deviation from the grain's average orientation – are tracked as a function of position within the electrode (near current collector, middle, and near separator) and as a function of electrochemical cycling. Further, a novel method of structural analysis is developed, offering insight into sub-grain diffusion behavior by comparing lattice misorientation near the grain boundary versus in the grain bulk. The present results suggest that electrode-scale spatial heterogeneity in lattice structure is induced by initial manufacturing conditions, and that radial gradients in lattice misorientation evolve at the primary particle scale with repeated electrochemical cycling.

25 ENERGY STORAGE↗

No detectable redox exchange between sulfur and iron during rapid cooling of basalts

The valence states of iron and sulfur in mantle-derived melts influence and respond to the composition of the mantle as well as the subsequent evolution of those melts in Earth's crust. Characterizing the valence states of iron and sulfur in silicate melts that have quenched to form glasses is therefore critical to understanding the composition of the mantle and the magmatic processes that take place before and during volcanic eruptions. Glasses quenched from silicate melts offer the opportunity to precisely measure sulfur and iron valence states, but whether the transition from melt to glass affects the valence state of sulfur and iron is uncertain. Here, we use the glassy margins of two pillow basalts, one from a mid-ocean ridge and one from a back-arc basin, as a natural experiment to test the effect of quench rate on sulfur and iron valence states. We report micro-X-ray Absorption Near Edge Structure (XANES) measurements of S 6+ /ΣS (S 6+ /[S 6+ +S 2- ]) and Fe 3+ /ΣFe (Fe 3+ /[Fe 2+ +Fe 3+ ]) along transects from the rapidly quenched rims of the pillows down into the slowly cooled crystal-rich interiors. The range of average quench rates estimated for our selected analysis areas range from 1.2 x 10 5 °C/sec at the pillow margin to 1.1 °C/sec in the interior and span quench rates experienced by natural and experimental glasses. On average, S6+/ΣS = 0.09 ± 0.01 and Fe 3+ /ΣFe = 0.147 ± 0.002 in the mid-ocean ridge sample and S 6+ /ΣS = 0.21 ± 0.01and Fe 3+ /ΣFe = 0.153 ± 0.004 in the back-arc sample, where the quoted uncertainty is the 1σ standard deviation of n= 9-16 analyses. We find that the S 6+ /ΣS and Fe 3+ /ΣFe values along transects in each sample show no systematic changes with depth, and by proxy, no systematic changes with quench rate. In each pillow, all measured S 6+ /ΣS and Fe 3+ /ΣFe ratios are within the absolute uncertainty of each technique. We propose that these observations are consistent with either sluggish reaction kinetics between sulfur and iron, or an insignificant temperature effect on sulfur-iron redox exchange equilibria. These observations demonstrate that sulfur and iron valence states in glasses with varying quench rates can be directly compared, and that changes in sulfur and iron valence during quench are below the limits of detection with XANES.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Inexact convex relaxations for AC optimal power flow: Towards AC feasibility

Convex relaxations of AC optimal power flow (AC-OPF) problems have attracted significant interest as in several instances they provably yield the global optimum to the original non-convex problem. If, however, the relaxation is inexact, the obtained solution is not AC-feasible. The quality of the obtained solution is essential for several practical applications of AC-OPF, but detailed analyses are lacking in existing literature. Here, this paper aims to cover this gap. We provide an in-depth investigation of the solution characteristics when convex relaxations are inexact, we assess the most promising AC feasibility recovery methods for large-scale systems, and we propose two new metrics that lead to a better understanding of the quality of the identified solutions. We perform a comprehensive assessment on 96 different test cases, ranging from 14 to 3120 buses, and we show the following: (i) Despite an optimality gap of less than 1%, several test cases still exhibit substantial distances to both AC feasibility and local optimality and the newly proposed metrics characterize these deviations. (ii) Penalization methods fail to recover an AC-feasible solution in 15 out of 45 test cases. (iii) The computational benefits of warm-starting non-convex solvers have significant variation, but a computational speedup exists in over 75% of cases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Certification and prediction of post-disturbance states in dynamic security assessment

Dynamic security assessment usually involves the simulation of system dynamics under large disturbances. The instant large disturbance occurs, the post-disturbance state of the system could deviate significantly from the pre-disturbance one. It is desirable and necessary to develop an efficient method to certify the existence of state and predict the approximate post-disturbance state because: (1) faster warning can be made in online assessment; and (2) the dynamic simulator can be given better initial values to calculate precise solutions, which prevents convergence failure brought on by poor initial values. We propose a novel approach for efficiently certifying and predicting the post-disturbance states in dynamic security assessment. Based on the fixed-point power flow mapping approach applied to salient pole generator models, the criterion for determining the existence and uniqueness of the post-disturbance solution is derived, and the bounds of post-disturbance solution can be rigorously characterized.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A reforecasting-based dynamic reserve estimation for variable renewable generation and demand uncertainty

The installed capacity of renewables-based energy sources has been increasing in traditional power systems. In order to accommodate the increased variability and uncertainty associated with the deeper penetration of renewable sources like solar and wind, adjusted amounts of dynamic reserve are needed. Although probabilistic dynamic reserve estimation methods have been previously developed, most of them consider the uncertainty to be represented by parametric density functions that tend to perform poorly under extreme events and, moreover, neglect uncertainty introduced by the forecasting model itself. Toward addressing these limitations, this work presents, for the first time, a dynamic reserve estimation method for flexibility that incorporates nonparametric density estimation and a machine learning based reforecasting to provide a day-ahead prediction of the mean and spread of uncertainty around the base forecast. The prediction is, in turn, used to estimate the up and down reserve relative to the base forecast. Here, the present method takes various endogenous and exogenous features, including the calendar variables, as input to estimate the day-ahead reserve. Using a combination of reforecasting and dynamic reserve estimation techniques, the method is shown to adjust better to the dynamic nature of reserve requirements providing only what is needed to accommodate the expected deviations. Considering California Independent System Operator (CAISO) solar, wind and load data over an 18 month period, up to 67% reduction in the amount of reserve capacity needed for a one day reserve and reserve penalty for solar uncertainty is demonstrated. Additionally, the risk of reserve insufficiency in meeting the net demand is reduced by 20% with the proposed method.

14 SOLAR ENERGY↗

Optimizing Phase Change Composite Thermal Energy Storage Using the Thermal Ragone Framework

The thermal Ragone framework can be applied to the design of thermal energy storage heat exchangers to identifying relationships between their power requirements and energy capabilities. This presentation focuses on the design of planar thermal energy storage heat exchangers with phase change materials and thermal conductivity additives. Finite-difference models were used to optimize thermal storage heat exchanger designs focusing on key design parameters of conductivity additive volume fraction, spacing between tubes, and the phase transition temperatures. Design trends were developed for optimal designs based on varying thermal power requirements. To aid in future device design, models of reduced complexity were developed with the ability to predict optimal designs with computational speeds up to 5,000 times faster than finite-difference models.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION,↗

An approach for fast and accurate simulation of phase change material based thermal energy storage in buildings

Latent heat thermal energy storage (LHTES) has significant potential for mitigating peak electricity demand and enabling load shifting in buildings. Phase Change Material embedded heat exchangers (PCM-HX) can significantly improve energy demand management due to high storage capacity. However, PCM-HX evaluation typically depends on computationally expensive fully transient simulations, posing significant challenges for scalable system- and building-level energy assessments across different climates and system architectures. This paper presents a generalized, accurate, and computationally efficient methodology for simulating building energy systems integrated with LHTES. The PCM-HX transient performance is represented by performance maps generated using a Generalized Resistance-Capacitance Model (GRCM) that enables accurate predictions of arbitrary PCM-HXs at low computational cost. The feasibility of the proposed approach was verified using a case study considering a dual-mode heat pump-thermal energy storage (HP-TES) system simulated in Modelica with Spawn of EnergyPlus™ for a DOE prototype small office building in two locations: Tampa, FL, and International Falls, MN. The PCM-HX performance maps provided accurate predictions of PCM-HX transient behavior, with mean absolute percentage deviations within 2–4% compared to GRCM while also achieving at least 1800× reduction in computational time. Moreover, the HP-TES system achieved energy savings of up to 17.4% in Tampa, FL, and 62.2% in International Falls, MN, demonstrating the broader applicability of the proposed methodology across different climate zones. This work highlights the importance of robust PCM-HX models in enabling accurate and computationally efficient building-level simulations and enabling future research opportunities for investigating optimized HP-TES designs and advanced control strategies for grid-interactive buildings.

Modelica↗

Multi-stage heat release of multi-component fuels: Insights and implications for advanced engine operation

Multi-stage heat release (MSHR) is a unique phenomenon typically seen in lean/diluted and low- to intermediate-temperature combustion. Despite its relevance to advanced engine operation, the MSHR of multi-component fuels has barely been quantified. This study aims to characterize the MSHR of multi-component fuels in a rapid compression machine (RCM) at conditions representative of advanced combustion engines. New experimental data are first reported in the RCM at an equivalence ratio of 0.4, pressure of 60 bar and temperatures from 702 to 795 K for a research grade, multi-component gasoline surrogate, termed PACE-20. Here, experiments confirm the existence of MSHR for PACE-20 at all temperatures, and reveal the strong inhibiting effect of temperature on MSHR, where increasing temperature inhibits MSHR by suppressing first stage heat release and promoting second and third stage heat release. A detailed chemical kinetic model is also adopted to model the experiments, with good agreement observed. The response of MSHR characteristics to changes in different engine operating parameters (i.e., temperature, pressure, equivalence ratio and CO 2 dilution level) and fuel compositions (i.e., mole fraction of n-pentane, n-heptane, isooctane, cyclopentane, 1-hexene, ethanol and aromatics in PACE-20) is further evaluated via statistical analysis coupling quasi-random sampling, extensive computer experiments and high-dimensional model representation. The change in MSHR is characterized through 8 quantities of interest (QOIs), i.e., duration and extent of each heat release stage, and their standard deviations. The analysis highlights the dependence of the QOIs on the individual parameters as well as their interplays, with temperature exhibiting the strongest impact among all parameters. Furthermore, it is demonstrated that if MSHR is to be facilitated and combustion phasing is to be extended to enable engine operation at higher compression ratios, it is recommended to operate the engine at low intake temperatures, boosted intake pressures and high CO 2 dilutions (i.e., high EGR levels) with gasoline fuels containing more n-pentane and less aromatics.

42 ENGINEERING↗

Laminar flame speed measurements of a gasoline surrogate and its mixtures with ethanol at elevated pressure and temperature

Laminar Flame speed measurements of a gasoline surrogate and mixtures of it with ethanol were conducted using a heated, constant-volume vessel. A spherical propagating flame was observed using a high-speed camera, and laminar flame speed was determined therefrom. Here, the gasoline surrogate, which serves as the baseline for the current study, consisted of four components, namely, iso-octane, n-heptane, toluene, and 1-hexene. Different mixtures of the gasoline surrogate and ethanol were studied, governed by the ethanol percentage in the mixture. That is, E0, E30, E50, and E85 mixtures represent 0%, 30%, 50%, and 85% ethanol in the gasoline surrogate mixture by liquid volume, respectively. Initial temperatures of 335, 359, and 408 K and initial pressures of 1 and 3 bar were investigated. The findings of this study are compared to results in the literature, which show good agreement for E0 but some deviation for the E30 blend. In general, the study showed an increase in laminar flame speed as the ethanol percentage increases in the mixture. Similarly, increasing the initial temperature with fixed ethanol percentage resulted in an increase in laminar flame speed, as expected. In contrast, increasing the initial pressure with fixed Ethanol percentage showed a decrease in laminar flame speed. Finally, the results are compared to an existing chemical kinetics model designed for ethanol and gasoline. Although agreement between the model and data is reasonable and mostly within about 10%, some improvement to the kinetics model is needed to uniformly lower the calculated flame speeds.

09 BIOMASS FUELS↗