Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “detector development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

A High Resolution Monolithic Crystal, DOI, MR Compatible, PET Detector

The principle objective of this proposal is to develop a positron emission tomography (PET) detector with depth-of-interaction (DOI) positioning capability that will achieve state of the art spatial resolution and sensitivity performance for small animal PET imaging. When arranged in a ring or box detector geometry, the proposed detector module will support <1 mm 3 image resolution and >15% absolute detection efficiency. The detector will also be compatible with operation in a MR scanner to support simultaneous multi-modality imaging. The detector design will utilize a thick, monolithic crystal scintillator readout by a two-dimensional array of silicon photomultiplier (SiPM) devices using a novel sensor on the entrance surface (SES) design. Our hypothesis is that our single-ended readout SES design will provide an effective DOI positioning performance equivalent to more expensive dual-ended readout techniques and at a significantly lower cost. Our monolithic crystal design will also lead to a significantly lower cost system. It is our goal to design a detector with state of the art performance but at a price point that is affordable so the technology can be disseminated to many laboratories. A second hypothesis is that using SiPM arrays, the detector will be able to operate in a MR scanner without any degradation in performance to support simultaneous PET/MR imaging. Having a co-registered MR image will assist in radiotracer localization and may also be used for partial volume corrections to improve radiotracer uptake quantitation. The far reaching goal of this research is to develop technology for medical research that will lead to improvements in human health care.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a 10 picosecond time-of-flight Counter

This Advanced Detector Research proposal presented a plan to develop an extremely fast time-of-flight detector for measuring the arrival time of beam protons scattered at small angles in high energy hadron colliders, such as the Large Hadron Collider (LHC). The proposed detectors employ a gas or quartz Cerenkov radiator which produce light when a proton passes through them, coupled to a micro-channel plate photomultiplier tube (MCP-PMT) that converts the light to an electrical pulse. The very small jitter of the pulse time provided by the MCP-PMT, combined with downstream electronics that accurately measure the pulse time results in a time-of-flight measurement of unprecedented accuracy. This ADR proposal was extremely successful, culminating in the development of a 10 ps resolution time-of-flight system, about an order of magnitude better than any time-of-flight system previously deployed at a collider experiment. The primary areas of advance were the usage of new radiator geometries providing fast detector signals, using multiple measurements to obtain a superior system resolution, and development of an electronics readout system tuned to maintain the excellent timing afforded by the detector. Test beam and laser tests have improved the knowledge of MCP-PMT’s and enabled the evaluation of the new detector concepts. In addition to being a generally useful detector concept, these fast timing detectors are a major component of proposed upgrades to the LHC ATLAS and CMS detectors, and if deployed could significantly enhance the discovery potential of these detectors, including contributions to the measurement of the properties of the Higgs Boson. In addition to the potential for furthering fundamental understanding of nature, the knowledge gained on MCP-PMT’s could be useful in developing improved versions of these devices which have promise in diverse fields such as biological and medical imaging.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Phase-1 Upgrade of the ATLAS Level-1 Endcap Muon Trigger. In: Proceedings of International Conference on Technology and Instrumentation in Particle Physics 2017

The Level-1 muon trigger for the ATLAS experiment identifies muons with high transverse momentum. Under the high luminosity condition in LHC Run 3, more powerful trigger system is needed to reject the backgrounds. New trigger processor board for Run 3 has been produced to achieve the required performance, by combining information from five different detectors. The performance of the new board and the readout system has been confirmed by a beam test. The new algorithms to make use of the new detectors have been developed, and are tested by MC simulation. With the new algorithms, the trigger rate is estimated to become lower than the required rate in Run 3.

Akatsuka, Shunichi↗

Progress Toward Fast Decay Energy Spectroscopy for Actinide Analysis

Decay energy spectroscopy (DES) is an increasingly popular technique for measuring isotopic composition of actinide samples for nuclear safeguards applications. Current approaches for actinide DES utilize milligram-scale external gold absorbers (> 0.1 nJ/K) that are integrated with actinide samples through mechanical kneading and are thermally connected to microcalorimeters using indium or gold wire bonds. This leads to relatively slow sensor rise time and, consequently, limits counting speed to a few counts per second. We are developing faster metallic magnetic calorimeter-based DES by integrating actinide samples with magnetic sensor materials. This reduces signal rise time and enables high counting speed while maintaining the ability to knead the radioactive source with the absorber. We have measured signal rise time of 0.7 μs with a 1.5 mg external gold absorber using this approach. Here, we also demonstrated online DES operation using an Ortec DSPEC 50, a commercially available data acquisition system developed for semiconductor detectors.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Fluorescence Detector of the Pierre Auger Observatory

The Pierre Auger Observatory is a hybrid detector for ultra-high energy cosmic rays. It combines a surface array to measure secondary particles at ground level together with a fluorescence detector to measure the development of air showers in the atmosphere above the array. The fluorescence detector comprises 24 large telescopes specialized for measuring the nitrogen fluorescence caused by charged particles of cosmic ray air showers. In this paper we describe the components of the fluorescence detector including its optical system, the design of the camera, the electronics, and the systems for relative and absolute calibration. We also discuss the operation and the monitoring of the detector. Finally, we evaluate the detector performance and precision of shower reconstructions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Using the automata processor for fast pattern recognition in high energy physics experiments. A proof of concept

Here, we explore the Micron Automata Processor (AP) as a suitable commodity technology that can address the growing computational needs of pattern recognition in High Energy Physics (HEP) experiments. A toy detector model is developed for which an electron track confirmation trigger based on the Micron AP serves as a test case. Although primarily meant for high speed text-based searches, we demonstrate a proof of concept for the use of the Micron AP in a HEP trigger application.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extracting low energy signals from raw LArTPC waveforms using deep learning techniques — A proof of concept

Here, we investigate the feasibility of using deep learning techniques, in the form of a one-dimensional convolutional neural network (1D-CNN), for the extraction of signals from the raw waveforms produced by the individual channels of liquid argon time projection chamber (LArTPC) detectors. A minimal generic LArTPC detector model is developed to generate realistic noise and signal waveforms used to train and test the 1D-CNN, and evaluate its performance on low-level signals. We demonstrate that our approach overcomes the inherent shortcomings of traditional cut-based methods by extending sensitivity to signals with ADC values below their imposed thresholds. This approach exhibits great promise in enhancing the capabilities of future generation neutrino experiments like DUNE to carry out their low-energy neutrino physics programs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The importance of temporal and spatial incoherence in quantitative interpretation of 4D-STEM

Recent developments in pixelated detectors, when combined with aberration correction of probe forming optics have greatly enhanced the field of scanning electron diffraction. Differential phase contrast is now routine and deep learning has been proposed as a method to extract maximum information from diffraction patterns. This study examines the effects of temporal and spatial incoherence on convergent beam electron diffraction patterns and demonstrates that simple center of mass measurements cannot be naively interpreted. The inclusion of incoherence in deep learning data sets is also discussed.

36 MATERIALS SCIENCE↗

Revealing latent pole and zone line information in atom probe detector maps using crystallographically correlated metrics

Poles and zone lines observed within atom probe field evaporation images are useful for a range of atom probe crystallography studies, including calibration of the reconstruction and crystallographic characterisation of microstructural features such as grain boundaries. However, this information is not always readily apparent. Techniques for plotting crystallographically correlated metrics contained within atom probe data to enhance pole and zone line contrast across the detector space are developed. This includes consideration of the electric field, molecular ions, lattice structure retained within the reconstruction, specific elemental species, the number of pulses between detection events, and the lateral distance between sequential detection events. These approaches are then applied to experimental atom probe tomography datasets on technically pure Al, nanocrystalline Al, highly doped Si, and additively manufactured Inconel 738, Haynes 282, and Ti–6Al–4V. The results facilitate the extension of atom probe crystallography studies to a broader range of crystalline datasets where crystallographic information is not readily apparent from existing methods, as well as a deeper understanding of field evaporation behaviour during an atom probe experiment.

47 OTHER INSTRUMENTATION↗

The surprisingly large neutron capture cross-section of 88 Zr

The probability that a nucleus will absorb a neutron, described in units of area as the neutron-capture cross section, is important to many areas of nuclear science including stellar nucleosynthesis, reactor performance, nuclear medicine, and defense applications. Although neutron-capture cross-sections have been directly measured for most stable nuclei, fewer results exist for radioactive isotopes and predictions typically have large uncertainties. There are almost no nuclear data for neutron-induced reactions on the radioactive nucleus 88 Zr, despite its significance for nuclear-security missions. By exposing 88 Zr to the intense neutron flux of a nuclear reactor, it was determined that 88 Zr has a thermal neutron capture cross section of (861,000 ± 69,000) b, which is the second-largest ever measured, despite being predicted to be only 10 b. The only other nuclei known to have thermal neutron capture cross sections greater than 1x10 5 b are 135 Xe and 157 Gd (2.6x10 6 b and 2.5x10 5 b, respectively) and no other cross section of comparable size has been discovered in the past 70 years (Fig. 1). The measurement of the 135 Xe cross section followed the determination that a fission product was poisoning the early reactors.7 The applications for 157 Gd were not immediately appreciated, but now the isotope has been developed into a detector material, burnable reactor poison, and potential medical neutron capture therapy (NCT) agent. In the case of 88 Zr, a unique aspect of the neutron-capture reaction is that both the target and the product 89 Zr nuclei are radioactive and give intense γ-ray emissions upon decay. This result suggests that as additional measurements with radioactive isotopes become feasible in the near future via access to new facilities for sample production and measurement, other cross-section surprises may be uncovered.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Excellent Timing Cherenkov Light Detection for Dual-readout High-granularity Calorimetry

We are developing a Cherenkov detector aiming for applications in the next-generation calorimetry. It is a calorimetry that combines dual-readout and high-granularity with excellent timing capability. This work is to prove the concept of the Cherenkov detector utilizing a resistive plate chamber (RPC) with Diamond-Like Carbon as resistive electrode. The first prototype was tested with β-rays and cosmic-rays. This paper discusses the behavior of the charge spectrum and the time resolution of the first prototype.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prompt proton decay in the vicinity of {sup 56}Ni

A new decay mode, the so called prompt proton decay, was discovered in 1998. It has since proven to be an important decay mechanism for several neutron deficient nuclei in the A{approx}60 region. To measure with high accuracy the energies and angular distributions of these protons, a state-of-the-art charged particle detector--LuWuSiA--was developed. It was first utilized during a fusion-evaporation reaction experiment performed at Argonne National Laboratory, U.S.A. In this contribution, the characteristics of the prompt proton decay are discussed along with the special features of LuWuSiA as well as a revisit to the prompt proton decay in {sup 58}Cu.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Is the QCD Plasma Observable at RHIC with Purely Hadronic Signals?

A consistent picture of the Au+Au and D+Au, {radical}(s) = 200 A GeV measurements at RHIC obtained with the PHENIX, STAR, PHOBOS and BRAHMS detectors was previously developed with the simulation LUCIFER. The approach was modeled on the early production of a fluid of pre-hadrons after the completion of an initial phase of high energy interactions. A successful description of both measured ''jet'' suppression and elliptical flow is obtained with a key element being the early production of pre-mesons which are relatively strongly interacting. The synthesis of these two signals in a common description puts in doubt the likelihood of direct hadronic observation of the colored phase which, for appreciably hard partons, lasts only a short interval {approx}t{sub p}, while the time for pre-mesons to hadronise t{sub f} is in general considerably longer.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

ACTAR: the New Generation of Active Targets

ACTAR is a new active target/time-projection chamber, designed for reaction and decay studies with nuclei far from stability. This class of instruments, initially developed for high-energy physics, has found profitable applications in medium- and low-energy nuclear physics as shown by a successful series of experiments. ACTAR builds on this experience to go beyond, incorporating developments in gas detector technology and a newly-designed electronic system of unprecedented scale in our research domain, to exploit the opportunities offered by the upcoming radioactive ion beams facilities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A new soft x-ray pulse height analysis array in the HL-2A tokamak

A new soft x-ray pulse height analysis (PHA) array including nine independent subsystems, on basis of a nonconventional software multichannel analysis system and a silicon drift detector (SDD) linear array consisting of nine high performance SDD detectors, has been developed in the HL-2A tokamak. The use of SDD has greatly improved the measurement accuracy and the spatiotemporal resolutions of the soft x-ray PHA system. Since the ratio of peak to background counts obtained from the SDD PHA system is very high, p/b{>=}3000, the soft x-ray spectra measured by the SDD PHA system can approximatively be regarded as electron velocity distribution. The electron velocity distribution can be well derived in the pure ohmic and auxiliary heating discharges. The performance of the new soft x-ray PHA array and the first experimental results with some discussions are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A hardened gated x-ray imaging diagnostic for inertial confinement fusion experiments at the National Ignition Facility

A gated x-ray detector is under development for use at the National Ignition Facility that is intended to provide plasma emission images in the presence of neutron yields up to 10{sup 15} expected during inertial confinement fusion experiments with layered cryogenic targets. These images are expected to provide valuable time-resolved measurements of core and fuel symmetries. Additional capabilities of this instrument will include the ability to make spatially resolved electron temperature measurements. A description of this instrument and its operation is given with emphasis on features that differentiate it from previous designs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Large electric-induced pyroelectric properties in (Pb{sub 0.87}La{sub 0.02}Ba{sub 0.1}) (Zr{sub 0.7}Sn{sub 0.24}Ti{sub 0.06})O{sub 3} antiferroelectric ceramics with excess PbO

(Pb{sub 0.87}La{sub 0.02}Ba{sub 0.1}) (Zr{sub 0.7}Sn{sub 0.24}Ti{sub 0.06})O{sub 3} (PLBZST) antiferroelectric ceramics with the addition of 0-9 wt. % excess PbO were fabricated by the conventional solid-state reaction process, and their microstructure, dielectric, and pyroelectric properties were systemically investigated. When excess PbO content was less than 9 wt. %, two pyrochlore phases were formed along with the perovskite phase. Compared with common specimens, PLBZST antiferroelectric ceramics with excess PbO exhibited a higher pyroelectric coefficient and a lower dielectric loss, which are beneficial for the development of pyroelectric devices. Around the Curie temperature, as the excess PbO increased from 0 wt. % to 9 wt. %, PLBZST ceramics' pyroelectric coefficient increased from 1600 {mu}C/m{sup 2}K to 4000 {mu}C/m{sup 2}K, and the figure of merit increased from 40 x 10{sup -5} Pa{sup -0.5} to 140 x 10{sup -5} Pa{sup -0.5} under a 400 V/mm dc field. The largest figure of merit of 200 x 10{sup -5} Pa{sup -0.5}, which is about 8 times higher than that of conventional phase transition materials barium strontium titanate (BST), was obtained in PLBZST ceramics with 6 wt. % excess PbO when a 600 V/mm dc bias field was applied. Therefore, improvement of pyroelectric property is beneficial for the development of infrared detectors.

36 MATERIALS SCIENCE↗

Note: Continuing improvements on the novel flat-response x-ray detector

This note describes multi-updates of the novel flat-response x-ray detector in fabrication technology, experimental application, and data uncertainty evaluation. Unlike the previous design, the compound filter is combined into one piece through an improved fabrication process that greatly enhanced its self-supporting capability. A method of pinhole-array imaging is introduced into the experimental application process to stop any debris from the hohlraum and to uniformly reduce the radiation flux. The experimental results show that this method works well. Furthermore, a method of uncertainty evaluation of the radiation flux measurement by the novel flat-response x-ray detector has been developed. The influence of the radiation spectrum to the flux measurement is analyzed. The evaluation shows that the relative uncertainty of the radiation flux is about 10% in higher radiation temperature condition (Tr > 150 eV) and 16% in lower radiation temperature condition (Tr < 100 eV).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗