Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “design validations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

ATLAS-MAP: An Automated Test Station for Gated Electronic Transport Measurements

The diversification of electronic materials in devices provides a strong incentive for methods to rapidly correlate device performance with fabrication decisions. In this work, we present a low-cost automated test station for gated electronic transport measurements of field-effect transistors. Utilizing open-source PyMeasure libraries for transparent instrument control, the “ATLAS-MAP” system serves as a customizable interface between sourcemeters and samples under test and is programmed to conduct transfer curve and van der Pauw methods with static and sweeping gate voltages. Zinc oxide transistors of variable thickness (5, 10, and 20 nm) and channel size (50 μm to 3 mm, of equal length and width) were fabricated to validate the design. Standardization of testing procedures and raw data formatting enabled automated data analysis. A detailed list of parts and code files for the system are provided.

36 MATERIALS SCIENCE↗

Robust Synthetic Biology Toolkit to Advance Carboxysome Study and Redesign

Carboxysomes are polyhedral protein organelles that microorganisms use to facilitate carbon dioxide assimilation. They are composed of a modular protein shell that envelops an enzymatic core mainly composed of physically coupled Rubisco and carbonic anhydrase. While the modular construction principles of carboxysomes make them attractive targets as customizable metabolic platforms, their size and complexity can be a hindrance. In this work, we design and validate a plasmid set, the pXpressome toolkit, in which α-carboxysomes are robustly expressed and remain intact and functional after purification. We tested this toolkit by introducing mutations that influence carboxysome structure and performance. We find that deletion of vertex-capping genes results in formation of larger carboxysomes, while deletion of facet forming genes produces smaller particles, suggesting that adjusting the ratio of these proteins can rationally affect morphology. Through a series of fluorescently labeled constructs, we observe that this toolkit leads to more uniform expression and better cell health than previously published carboxysome expression systems. Overall, the pXpressome toolkit facilitates the study and redesign of carboxysomes with robust performance and improved phenotype uniformity. The pXpressome toolkit will support efforts to remodel carboxysomes for enhanced carbon fixation or serve as a platform for other nanoencapsulation goals.

59 BASIC BIOLOGICAL SCIENCES↗

Application of a High-Throughput Analyzer in Evaluating Solid Adsorbents for Post-Combustion Carbon Capture via Multicomponent Adsorption of CO2, N-2, and H2O

Despite the large number of metal-organic frameworks that have been studied in the context of post-combustion carbon capture, adsorption equilibria of gas mixtures including CO2, N-2, and H2O, which are the three biggest components of the flue gas emanating from a coal- or natural gas-fired power plant, have never been reported. Here, we disclose the design and validation of a high-throughput multicomponent adsorption instrument that can measure equilibrium adsorption isotherms for mixtures of gases at conditions that are representative of an actual flue gas from a power plant. This instrument is used to study 15 different metal-organic frameworks, zeolites, mesoporous silicas, and activated carbons representative of the broad range of solid adsorbents that have received attention for CO2 capture. While the multicomponent results presented in this work provide many interesting fundamental insights, only adsorbents functionalized with alkylamines are shown to have any significant CO2 capacity in the presence of N-2 and H2O at equilibrium partial pressures similar to those expected in a carbon capture process. Most significantly, the amine-appended metal organic framework mmen-Mg-2(dobpdc) (mmen = N,N'-dimethylethylenediamine, dobpdc (4-) = 4,4'-dioxido-3,3'-biphenyldicarboxylate) exhibits a record CO2 capacity of 4.2 +/- 0.2 mmol/g (16 wt %) at 0.1 bar and 40 degrees C in the presence of a high partial pressure of H2O.

Mason, JA↗

CRISPR-Cas12a nucleases function with structurally engineered crRNAs: SynThetic trAcrRNA

Abstract CRISPR-Cas12a systems are becoming an attractive genome editing tool for cell engineering due to their broader editing capabilities compared to CRISPR-Cas9 counterparts. As opposed to Cas9, the Cas12a endonucleases are characterized by a lack of trans-activating crRNA (tracrRNA), which reduces the complexity of the editing system and simultaneously makes CRISPR RNA (crRNA) engineering a promising approach toward further improving and modulating editing activity of the CRISPR-Cas12a systems. Here, we design and validate sixteen types of structurally engineered Cas12a crRNAs targeting various immunologically relevant loci in-vitro and in-cellulo . We show that all our structural modifications in the loop region, ranging from engineered breaks (STAR-crRNAs) to large gaps (Gap-crRNAs), as well as nucleotide substitutions, enable gene-cutting in the presence of various Cas12a nucleases. Moreover, we observe similar insertion rates of short HDR templates using the engineered crRNAs compared to the wild-type crRNAs, further demonstrating that the introduced modifications in the loop region led to comparable genome editing efficiencies. In conclusion, we show that Cas12a nucleases can broadly utilize structurally engineered crRNAs with breaks or gaps in the otherwise highly-conserved loop region, which could further facilitate a wide range of genome editing applications.

59 BASIC BIOLOGICAL SCIENCES↗

Operational resilience metrics for power systems with penetration of renewable resources

Abstract Modern power grid is evolving towards carbon neutrality by deploying increasing amount of renewable energy resources. However, the impact of renewable generation on power system planning and operation is not sufficiently investigated, especially the capability of renewable penetrated power systems to resist and recover from major disturbances, which is a critical concern for system operators. Novel metrics and evaluation methodologies are needed to depict systems’ ability in response to events caused by natural disasters, and quantitatively evaluate system performance in various time scales. In this paper, operational resilience metrics are proposed for power systems with penetration of renewable energy resources based on transient stability principles. A systematic methodology is proposed to quantitatively assess the evolution of system performance during various stages of the disaster process. Based on the proposed metrics, a resilience‐oriented disaster management strategy is designed and validated using the modified IEEE 39‐bus test system. The simulation results demonstrate the validity of the proposed metrics and strategy, and show that the system resilience is enhanced during the mitigation of fault conditions.

Gui, Jianzhong↗

SFCOMPO Database of Spent Nuclear Fuel Assay Data – the Next Frontier

SFCOMPO is the world’s largest database for measured spent nuclear fuel assay data. An international effort coordinated by the Nuclear Energy Agency (NEA) resulted in a significant expansion of the database and its release online in 2017 as a downloadable application. The SFCOMPO Technical Review Group (TRG) was recently formed under the direction of NEA’s Nuclear Science Committee/Working Party on Nuclear Criticality Safety and was mandated to maintain and further coordinate the development of SFCOMPO. This TRG is currently focused on (1) critical evaluation of the experimental assay data by independent experts and (2) development of benchmarks and benchmark models that can be applied to validate burnup codes. This will improve the quality and documentation of the experimental datasets and enable their use by the international community to support code validation for design and safety analysis of spent nuclear fuel transportation, storage, and repository applications. It follows the precedent and draws on the experience gained from similar NEA efforts in the International Reactor Physics Experiment Evaluation Project and the International Criticality Safety Benchmark Experiment Project. Ongoing SFCOMPO evaluations have served as a test bed to develop templates for documenting evaluations, develop review guidance, improve approaches for a global uncertainty analysis, and devise a strategy focused on providing practical information of highest value to the user community. The current effort, status, and associated challenges are discussed.

Ilas, Germina↗

Quadrupole mass spectrometry and time-of-flight analysis of ions resulting from 532 nm pulsed laser ablation of Ni, Al, and ZnO targets

This work describes the design and validation of an instrument to measure the kinetic energies of ions ejected by the pulsed laser ablation (PLA) of a solid target. Mass spectra show that the PLA of Ni, Al, and ZnO targets, in vacuum, using the second harmonic of a Nd:YAG laser (532 nm, pulse duration {approx}10 ns) generates abundant X{sup n+} ions (n{<=}3 for Ni, {<=}2 for Al, {<=}3 and {<=}2 for Zn and O respectively from ZnO). Ions are selected by their mass/charge (m/z) ratio prior to the determination of their times of flight. PLA of Ni has been studied in most detail. The mean velocities of ablated Ni{sup n+} ions are shown to follow the trend v(Ni{sup 3+})>v(Ni{sup 2+})>v(Ni{sup +}). Data from Ni{sup 2+} and Ni{sup 3+} are fitted to shifted Maxwellian functions and agree well with a model which assumes both thermal and Coulombic contributions to ion velocities. The dependence of ion velocities on laser pulse energy (and fluence) is investigated, and the high energy data are shown to be consistent with an effective accelerating voltage of {approx}90 V within the plume. The distribution of velocities associated with Ni{sup 3+} indicates a population at cooler temperature than Ni{sup 2+}.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High efficiency quasi-monochromatic infrared emitter

Incandescent radiation sources are widely used as mid-infrared emitters owing to the lack of alternative for compact and low cost sources. A drawback of miniature hot systems such as membranes is their low efficiency, e.g., for battery powered systems. For targeted narrow-band applications such as gas spectroscopy, the efficiency is even lower. In this paper, we introduce design rules valid for very generic membranes demonstrating that their energy efficiency for use as incandescent infrared sources can be increased by two orders of magnitude.

07 ISOTOPE AND RADIATION SOURCES↗

Design, development, and acceleration trials of radio-frequency quadrupole

A deuteron radio frequency quadrupole (RFQ) accelerator has been designed, fabricated, and tested at BARC, which will be used for neutron generation. The RFQ operates at a frequency of 350 MHz and needs an inter-vane voltage of 44 kV to accelerate the deuteron beam to 400 keV within a length of 1.03 m. The error analysis shows that the offset of two opposite vanes in the same direction by 100 μm leads to a change in resonant frequency by 1.3 MHz and a significant change of fields in the quadrants (∼±40% with respect to average field). From the 3D analysis, we have observed that the unwanted dipole mode frequencies are very near to the quadrupole mode frequency which will make structure sensitive to the perturbations. In order to move the dipole modes away from the quadrupole modes, we have used the dipole stabilizer rods. The 5 wire transmission line theory was used to study the perturbative analysis of the RFQ and based on this a computer program has been written to tune the cavity to get required field distribution. Based on these studies, a 1.03 m long RFQ made of OFE copper has been fabricated and tested. Even though the RFQ was designed for deuteron (D{sup +}) beam, we tested it by accelerating both the proton (H{sup +}) and D{sup +} beams. The RFQ was operated in pulsed mode and accelerated both H{sup +} and D{sup +} beams to designed values of 200 and 400 keV, respectively. The measured parameters are in good agreement with the designed values validating our simulations and fabrication processes. In this paper, simulations, RF measurements, and beam commissioning results are presented.

43 PARTICLE ACCELERATORS↗

Design and characterization of electron beam focusing for X-ray generation in novel medical imaging architecture

A novel electron beam focusing scheme for medical X-ray sources is described in this paper. Most vacuum based medical X-ray sources today employ a tungsten filament operated in temperature limited regime, with electrostatic focusing tabs for limited range beam optics. This paper presents the electron beam optics designed for the first distributed X-ray source in the world for Computed Tomography (CT) applications. This distributed source includes 32 electron beamlets in a common vacuum chamber, with 32 circular dispenser cathodes operated in space charge limited regime, where the initial circular beam is transformed into an elliptical beam before being collected at the anode. The electron beam optics designed and validated here are at the heart of the first Inverse Geometry CT system, with potential benefits in terms of improved image quality and dramatic X-ray dose reduction for the patient.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetically tunable unidirectional waveguide based on magnetic photonic crystals

In this letter, we presented a magnetically tunable ferrite-loaded unidirectional waveguide based on magnetic photonic crystals. Two rows of ferrite rods are symmetrically arranged near the two lateral sides of the rectangular waveguide, where they are biased with static magnetic fields with the same amplitude and opposite directions along the rod axis. Since the magnetic one-way transmission is induced by the magnetic surface plasmon resonance, the operating band of the unidirectional waveguide can be tuned by changing the biased magnetic field intensity. To validate the design, a prototype was fabricated and measured. Both the simulation and experiment results verify the unidirectional transmission property.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

PM4Stell: A prototype permanent magnet stellarator structure

Permanent magnets provide a possible solution to simplify complicated stellarator coils. Here, a prototype permanent magnet stellarator structure, PM4Stell, has been funded to demonstrate the technical feasibility of using permanent magnets to create the shaping field of a stellarator. Permanent magnets in uniform cubes with three polarization directions will be carefully placed to generate the required magnetic field for a National Compact Stellarator eXperiment-like equilibrium together with planar toroidal field coils. Discrete magnets will be glued together and inserted into a “post-office-box-like” supporting structure. Electromagnetic and structural analyses have been done to validate the design. Error field correction magnets will be used to shim possible error fields. The design efforts of the prototype permanent magnet stellarator structure are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of helicon waves with phase contrast imaging on DIII-D – A theoretical feasibility study

A DIII-D high-beta H-mode discharge, with I p = 850 kA, B t = 2.1 T n e = 4 10 19 m –3 , has been designed to validate full wave modeling of helicon waves by optimizing the expected response of the Phase Contrast Imaging diagnostic. Helicon waves have been predicted to have high current drive efficiency off-axis without facing the accessibility issues of lower-hybrid waves. To test these predictions experimentally, DIII-D has recently commissioned a high-power helicon antenna. To confidently predict the behavior of helicon waves in future devices, measurements of their fundamental properties and validation against models will be essential. Phase contrast imaging (PCI) is an absolutely calibrated internal reference interferometer able to measure density fluctuations with radial wavenumbers k R between 1.5 cm –1 and 20 cm –1 . For helicon waves 2 cm –1 < k R < 10 cm –1 is expected, allowing PCI to measure their envelope and wavenumber spectrum. This makes PCI a powerful tool for the validation of state-of-the-art models, like the AORSA full wave code. AORSA is used to compute the density perturbations measured by the PCI with 2D calculations corresponding to 11 different toroidal mode numbers combined to resolve the trajectory of the helicon wave in 3D. This is necessary because the waves travel 120 degrees toroidally from the antenna to the PCI. Here, a cold plasma finite element model (CPFEM) [4] is used to predict propagation through the scrape-off layer. The result of the CPFEM model is connected to AORSA by creating an artificial Gaussian antenna on the last closed flux surface. PCI shows best results for waves with small vertical wavenumbers k z . Modeling the helicon waves for several past DIII-D experiments shows that k z is minimized if the intersection of the helicon and the PCI laser beams occurs in the midplane. For such an optimized scenario the predicted signal level is two orders of magnitude larger than the background density fluctuations arising from broadband turbulence.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optically multiplexed neutron time-of-flight technique for inertial confinement fusion

Neutron time-of-flight (nTOF) detectors are crucial in diagnosing the performance of inertial confinement fusion (ICF) experiments, which implode targets of deuterium–tritium fuel to achieve thermonuclear conditions. These detectors utilize the fusion neutron energy spectrum to extract key measurements, including the hotspot ion temperature and fuel areal density. Previous work [Danly et al., Rev. Sci. Instrum. 94, 043502 (2023)] has demonstrated adding 1D spatial resolution to an nTOF-like detector using a neutron aperture and streak camera to measure the ion temperature profile of an ICF implosion. By contrast, the study presented herein explores modifying the 1D detector to use a fast photomultiplier tube (PMT) to validate the design of a 2D spatially resolved instrument based on reconstruction from 1D profiles. The modification would collect time-of-flight traces from separate scintillators in an imaging array with one PMT using optical fibers of varying lengths to time-multiplex the signals. This technique has been demonstrated in ride-along experiments on the OMEGA laser with 20 fiber-coupled scintillator channels connected to a Photek PMT210. Results provide constraints on the fiber lengths and PMT gating requirements to promote pulse fidelity throughout all channels. Calibration of the detector to fixed nTOFs can provide a preliminary estimate of the instrument response function (IRF), although measurement of the IRF is currently under way. These results suggest that nTOF signals can potentially be time-multiplexed with fibers so long as the design is strategic to mitigate signal-to-noise reduction, modal dispersion, and charge build-up in the PMT, which has implications beyond ion temperature imaging.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Iterative optimization yields Mcl-1–targeting stapled peptides with selective cytotoxicity to Mcl-1–dependent cancer cells

Bcl-2 family proteins regulate apoptosis, and aberrant interactions of overexpressed antiapoptotic family members such as Mcl-1 promote cell transformation, cancer survival, and resistance to chemotherapy. Discovering potent and selective Mcl-1 inhibitors that can relieve apoptotic blockades is thus a high priority for cancer research. An attractive strategy for disabling Mcl-1 involves using designer peptides to competitively engage its binding groove, mimicking the structural mechanism of action of native sensitizer BH3-only proteins. We transformed Mcl-1–binding peptides into α-helical, cell-penetrating constructs that are selectively cytotoxic to Mcl-1–dependent cancer cells. Critical to the design of effective inhibitors was our introduction of an all-hydrocarbon cross-link or “staple” that stabilizes α-helical structure, increases target binding affinity, and independently confers binding specificity for Mcl-1 over related Bcl-2 family paralogs. Two crystal structures of complexes at 1.4 Å and 1.9 Å resolution demonstrate how the hydrophobic staple induces an unanticipated structural rearrangement in Mcl-1 upon binding. Systematic sampling of staple location and iterative optimization of peptide sequence in accordance with established design principles provided peptides that target intracellular Mcl-1. Here, this work provides proof of concept for the development of potent, selective, and cell-permeable stapled peptides for therapeutic targeting of Mcl-1 in cancer, applying a design and validation workflow applicable to a host of challenging biomedical targets.

59 BASIC BIOLOGICAL SCIENCES↗

Parametric Study of the Vacuum Permeator for the Tritium Extraction eXperiment

Tritium breeding is a critical component of any self-sustaining future fusion reactor. The liquid metal eutectic, PbLi, is of particular interest as a tritium breeder material due to its favorable thermophysical and neutronic properties. One of the several remaining challenges facing PbLi breeder blankets is the need to design and validate a highly efficient tritium extraction system. The vacuum permeator is a promising extraction concept that utilizes tritium permeation through a highly permeable metal membrane. The Tritium Extraction eXperiment (TEX) is a forced-convection PbLi loop constructed to investigate tritium extraction from PbLi with vacuum permeators. Accurate thermal-hydraulic and tritium transport models are required to establish appropriate test matrices, predict experiment outcomes, and analyze data. However, the hydrogen transport properties of PbLi and permeator materials have large uncertainties. A database is collected, and a parametric analysis is conducted on the effect of hydrogen transport material properties: diffusivity of H in PbLi and permeator, solubility of H in PbLi and permeator, and permeator surface recombination constant on the expected tritium extraction efficiency for a vacuum permeator installed in TEX. As a result, we observe solubility of H in PbLi and the permeator and the recombination constant of the permeator have the largest effect on the extraction efficiency.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

THE ATHENA ASTROPHYSICAL MAGNETOHYDRODYNAMICS CODE IN CYLINDRICAL GEOMETRY

A method for implementing cylindrical coordinates in the Athena magnetohydrodynamics (MHD) code is described. The extension follows the approach of Athena's original developers and has been designed to alter the existing Cartesian-coordinates code as minimally and transparently as possible. The numerical equations in cylindrical coordinates are formulated to maintain consistency with constrained transport (CT), a central feature of the Athena algorithm, while making use of previously implemented code modules such as the Riemann solvers. Angular momentum transport, which is critical in astrophysical disk systems dominated by rotation, is treated carefully. We describe modifications for cylindrical coordinates of the higher-order spatial reconstruction and characteristic evolution steps as well as the finite-volume and CT updates. Finally, we present a test suite of standard and novel problems in one, two, and three dimensions designed to validate our algorithms and implementation and to be of use to other code developers. The code is suitable for use in a wide variety of astrophysical applications and is freely available for download on the Web.

79 ASTRONOMY AND ASTROPHYSICS↗

Meta-uncertainty for particle image velocimetry

Uncertainty quantification for Particle Image Velocimetry (PIV) is critical for comparing experimentally measured flow fields with Computational Fluid Dynamics (CFD) results, and model design and validation. However, PIV features a complex measurement chain with coupled, non-linear error sources, and quantifying the uncertainty is challenging. Multiple assessments show that none of the current methods can reliably measure the actual uncertainty across a wide range of experiments, and estimates can vary. Because the current methods differ in assumptions regarding the measurement process and calculation procedures, it is not clear which method is best to use for an experiment where the error distribution is unknown. To address this issue, we propose a method to estimate an uncertainty method's sensitivity and reliability, termed the Meta-Uncertainty. The novel approach is automated, local, and instantaneous, and based on perturbation of the recorded particle images. We developed an image perturbation scheme based on adding random unmatched particles to the interrogation window pair considering the signal-to-noise (SNR) of the correlation plane. Each uncertainty scheme's response to several trials of random particle addition is used to estimate a reliability metric, defined as the rate of change of the inter-quartile range (IQR) of the uncertainties with increasing levels of particle addition. We also propose applying the meta-uncertainty as a weighting metric to combine uncertainty estimates from individual schemes, based on ideas from the consensus forecasting literature. We use planar and stereo PIV measurements across a range of canonical flows to assess the performance of the uncertainty schemes. Further, a novel method is introduced to assess an uncertainty scheme's performance based on a quantile comparison of the error and uncertainty distributions, generalizing the current method of comparing the RMS of the two distributions. Here, the results show that the combined uncertainty method outperforms the individual methods, and this work establishes the meta-uncertainty as a useful reliability assessment tool for PIV uncertainty quantification.

47 OTHER INSTRUMENTATION↗