Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “demand modelling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Quantifying and Optimizing the Energy Benefits of Mass Timber Construction

The International Mass Timber Alliance (IMTA) is a global organization of industry leaders, engineers, scientists, and associations dedicated to advancing mass timber construction. Its mission is to generate and disseminate scientific data supporting the development of standardized construction and energy efficient practices that promote the adoption of mass timber worldwide. IMTA collaborated with Oak Ridge National Laboratory (ORNL) to leverage ORNL’s expertise in building envelope modeling and testing to evaluate how mass timber construction can reduce peak heating and cooling demand, lower overall energy use, and improve resilience during power outages. A previous study of 80 mass timber buildings in Finland found measured energy use up to 50% lower than predicted by simulation. This project aimed to validate and extend those findings for U.S. buildings through analytical modeling, laboratory testing, and full-scale building evaluations. The research focused on the thermal performance of low-embodied-energy wall assemblies, such as cross-laminated timber (CLT) panels and log walls, with particular attention to the effects of thermal inertia on indoor comfort and energy performance. While mass timber’s structural and fire-resistance properties are well documented, its whole-building thermal behavior has received limited attention. Field data, simulation results, and resilience testing from this study will inform future modeling practices, design guidelines, and construction practices by quantifying the unique thermal and demand-flexibility benefits of mass timber construction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Designing ITER motional Stark effect line shift (MSE-LS) spectrometers

As a part of ITER beam aided diagnostics, the design of Motional Stark Effect (MSE) diagnostic observing the emission from the Balmer-α line is underway. The physics of Stark splitting shows that the Stark manifold is polarization dependent, and the energy splitting results in a line shift proportional to the electric field. Due to the challenges of maintaining the calibration of the plasma facing mirrors in ITER, the conventional MSE polarimetry measurement technique is replaced with a spectral approach that is deemed more favorable in the ITER environment. The MSE line shift (LS) diagnostic is designed to quantify the Lorentz electric field magnitude by measuring the Stark manifold using visible spectroscopy. In the presence of large magnetic fields and high energy heating beams of 1 MeV, the expected Stark splitting is much larger than in typical devices. The MSE-LS design has unique challenges requiring careful consideration and modeling of its viewing geometry and photon budget. The MSE-LS approach on ITER is promising but has stringent demands on the allowable errors for the statistical and systematic fitting uncertainties. In this study, a full system model and numerical simulations of data for each sightline are completed. For a range of optical transmission fractions, photon noise analysis is conducted to determine the statistical uncertainties. This provides guidance on the spectrometer throughput, dispersion at the detector, optics, and other design choices. A conceptual design of a high throughput spectrometer with a volume phase transmission grating is presented.

Instruments & Instrumentation↗

Analysis of Reactive Power Load Modeling Techniques for PV Impact Studies [Slides]

The increasing availability of advanced metering infrastructure (AMI) data has led to significant improvements in load modeling accuracy. However, since many AMI devices were installed to facilitate billing practices, few utilities record or store reactive power demand measurements from their AMI. When reactive power measurements are unavailable, simplifying assumptions are often applied for load modeling purposes, such as applying constant power factors to the loads. The objective of this work is to quantify the impact that reactive power load modeling practices can have on distribution system analysis, with a particular focus on evaluating the behaviors of distributed photovoltaic (PV) systems with advanced inverter capabilities. Quasi-static time-series simulations were conducted after applying a variety of reactive power load modeling approaches, and the results were compared to a baseline scenario in which real and reactive power measurements were available at all customer locations on the circuit. Overall, it was observed that applying constant power factors to loads can lead to significant errors when evaluating customer voltage profiles, but that performing per-phase time-series reactive power allocation can be utilized to reduce these errors by about 6x, on average, resulting in more accurate evaluations of advanced inverter functions.

14 SOLAR ENERGY↗

End-Use Savings Shapes Measure Documentation: LED Lighting

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models over the past three years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a timeseries profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each timestep. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on a single end-use savings shape measure - LED lighting. The LED lighting measure replaces interior lights with LEDs where applicable. The measure resulted in 1.25 TBtu energy savings across the building stock, with the majority of savings occurring in retail and warehouse buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Neural network model of neutral beam injection in the EAST tokamak to enable fast transport simulations

The neutral beam injection (NBI) system in EAST produces energetic neutral particles, which collide with electrons and ions in tokamak plasmas and heat the plasmas through Coulomb collisions. Moreover, it drives a non-inductive source of current, due to the charge-exchange collision between neutral particles and ions, and injects toroidal torque, which generates a toroidal rotation of the plasma. The effect caused by the NBI system, such as plasma heating, current drive, total neutron rate, momentum transfer, and shine-through, are modeled by a comprehensive module called NUBEAM. However, NUBEAM is computationally intensive since it relies on Monte Carlo methods. In this work, a neural network model has been developed as a surrogate model for NUBEAM in EAST. The database for neural-network model training, validation and testing is generated by running TRANSP for experimental discharges from recent EAST campaigns (after the latest NBI upgrade) while using the NUBEAM module. Simulation results illustrate that the trained neural network has the capability of replicating the predictions made by NUBEAM while demanding a significantly shorter execution time. Finally, these results indicate that surrogate models like the one proposed in this work could enable fast transport simulations for EAST after integrating them into a control-oriented predictive code such as COTSIM.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

gcm_eval (Global Climate Model Evaluation) [SWR-24-37]

The interplay between energy, climate, and weather is becoming more complex as our changing climate continues to affect the weather we experience which in turn drives changes in the ever increasing share of renewable energy generation and energy demand. Energy system analyses commonly rely on meteorological inputs to estimate renewable energy generation and energy demand; however, these inputs rarely represent the estimated impacts of future climate change. Climate models and publicly available climate change datasets can be used for this purpose, but the selection of inputs from the myriad of available models and datasets is a nuanced and often subjective process. There is no single perfect climate model or dataset for all applications. In this repository, we include software and the corresponding assessments of various global climate models (GCMs) from the Coupled Model Intercomparison Project (CMIP6), evaluating their skills with respect to the historical climate and comparing of their future projections of climate change. We focus on variables that directly affect the energy system including the representation of extreme values that can drive grid resilience events. The objective of this repository is not to recommend the best climate model and dataset for a given analysis, but instead to provide a reference to facilitate the selection of climate models and datasets in subsequent work.

Buster, Grant↗

Visualization of Multi-Fidelity Approximations of Stochastic Economic Dispatch

As renewable energy generation deployment increases, the operation of electrical grids becomes more complex. Economic dispatch is part of a grid operator's regular decision process where the amount of energy to generate is determined based on the number of available generators and the actual level of energy demand. Renewable generators are inherently stochastic due to the chaotic nature of weather patterns, and thus, real-time decisions of economic dispatch become increasingly complex. Modeling efforts to assist in these decisions in the highest fidelity typically take hours to days to solve on leadership-class computers; too long for the 5-minute operational time-frame demanded of operators. Alternatively, multi-fidelity approximations can be used to predict generation levels quickly and with sufficient accuracy to be used for real-time operations. We have developed a visualization tool to demonstrate the utility of multi-fidelity approximations by displaying contextual results of economic dispatch approximations, comparisons across fidelity levels of generation levels and possible failures to meet demand, and meta-data on the modeling setup.

interactive visualization↗

Review of data-driven models for quantifying load shed by non-residential buildings in the United States

Shifting and shedding power demand in buildings can be cost-effective techniques for grids to function reliably and for end users to earn compensation. Grid operators reimburse customers in proportion to the quantity of load shed. Simple data-driven methods are used to quantify this shed, which is the difference between a measured load during the event and modeled "baseline" that would have occurred in absence of the event. These methods have evolved over the years and in many cases have been integrated with building physics, to make them a hybrid between physics based and empirical models. However, there is no comprehensive analysis that provides guidance to building operators, grid operators and researchers in selecting appropriate models based on their specific needs and available data. Here, this work aims to fill this gap by critically assessing the performance of baseline models put forward from the year 2000 through 2023. The literature reviewed includes reports generated by grid operators, reports from national laboratories and academic journal articles. The work outlines modeling features like the inputs, training period, estimation method, adjustments to fine tune the predictions and metrics to evaluate the performance. A comprehensive list of 50 models has been provided. For each model, the study explores the applicability of the model to weather sensitive buildings, variability in the building profile, timing of the event, and whether the building reduces energy consumption before an event. The work identifies the situations in which a particular model works and draws lessons based on evidence of performance. Finally, recommendations to aid in model selection are given.

97 MATHEMATICS AND COMPUTING↗

Thermally anisotropic building envelope for thermal management: finite element model calibration using field evaluation data

The thermally anisotropic building envelope (TABE) is an active building envelope that redistributes thermal loads in response to weather conditions and building energy demand. Conductive layers throughout the TABE distribute low-grade heat among hydronic loops, altering heat flow direction and intensity. Finite element models of TABE roof and wall panels were developed and calibrated using field evaluation data. The calibration results showed that heat flux differences between the experimental data and finite element models averaged –0.42% and 3.57%, with a maximum mean square error of 1.78 and 3.96 for roof and wall panels, respectively. A reduction in heat flux from the environment to the building living space over the entire testing period (weeks in July/August) was found to be 85% for roof panels and 335% (load reversed) for wall panels. Finally, these results indicate TABE can effectively harness low-grade thermal energy sources to achieve high energy efficiency and promote demand-side management.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Estimating Future Surface Water Availability Through an Integrated Climate‐Hydrology‐Management Modeling Framework at a Basin Scale Under CMIP6 Scenarios

Abstract Climate change and increasing water demand due to population growth pose serious threats to surface water availability. The biggest challenge in addressing these threats is the gap between climate science and water management practices. Local water planning often lacks the integration of climate change information, especially with regard to its impacts on surface water storage and evaporation as well as the associated uncertainties. Using Texas as an example, state and regional water planning relies on the use of reservoir “Firm Yield” (FY)—an important metric that quantifies surface water availability. However, this existing planning methodology does not account for the impacts of climate change on future inflows and on reservoir evaporation. To bridge this knowledge gap, an integrated climate‐hydrology‐management (CHM) modeling framework was developed, which is generally applicable to river basins with geographical, hydrological, and water right settings similar to those in Texas. The framework leverages the advantages of two modeling approaches—the Distributed Hydrology Soil Vegetation Model (DHSVM) and Water Availability Modeling (WAM). Additionally, the Double Bias Correction Constructed Analogues method is utilized to downscale and incorporate Coupled Model Intercomparison Project Phase 6 GCMs. Finally, the DHSVM simulated naturalized streamflow and reservoir evaporation rate are input to WAM to simulate reservoir FY. A new term—“Ratio of Firm Yield” (RFY)—is created to compare how much FY changes under different climate scenarios. The results indicate that climate change has a significant impact on surface water availability by increasing reservoir evaporation, altering the seasonal pattern of naturalized streamflow, and reducing FY.

54 ENVIRONMENTAL SCIENCES↗

Real-Time Implementation of Smart Wireless Charging of On-Demand Shuttle Service for Demand Charge Mitigation

This paper presents a smart charge management strategy for an on-demand electric shuttle operating at the National Renewable Energy Laboratory (NREL) campus and supported by an inductive charger at the vehicle's waiting spot. A new control algorithm has been proposed for mitigating the demand charges incurred from the wireless charger. It monitors the shuttle, wireless charger, renewable energy generation, and other loads and regulates charging behavior for demand charge mitigation. Within the control algorithm, an energy prediction is made to estimate the mobility needs of the vehicle and maintain uninterrupted service during operation while still minimizing peak demand. The proposed controller is designed and optimized using a Simulink model for the entire system. It is then implemented and tested in real time at the NREL campus using online cloud services. Two vehicle-use cases' charge-sustaining and charge-depletion operation' are tested under different campus power profiles and drive cycles to assess the controller's performance. In this work, the proposed controller showed a robust performance under different driving scenarios, with high correlation between simulation and experimental data. The results show that proper demand response can be achieved, with an average of 94% reduction of charging loads during peak demand events.

33 ADVANCED PROPULSION SYSTEMS↗

Projecting Large Fires in the Western US With an Interpretable and Accurate Hybrid Machine Learning Method

More frequent and widespread large fires are occurring in the western United States (US), yet reliable methods for predicting these fires, particularly with extended lead times and a high spatial resolution, remain challenging. In this study, we proposed an interpretable and accurate hybrid machine learning (ML) model, that explicitly represented the controls of fuel flammability, fuel availability, and human suppression effects on fires. The model demonstrated notable accuracy with a F 1 -score of 0.846 ± 0.012, surpassing process-driven fire danger indices and four commonly used ML models by up to 40% and 9%, respectively. More importantly, the ML model showed remarkably higher interpretability relative to other ML models. Specifically, by demystifying the “black box” of each ML model using the explainable AI techniques, we identified substantial structural differences across ML fire models, even among those with similar accuracy. The relationships between fires and their drivers, identified by our model, were aligned closer with established fire physical principles. The ML structural discrepancy led to diverse fire predictions and our model predictions exhibited greater consistency with actual fire occurrence. With the highly interpretable and accurate model, we revealed the strong compound effects from multiple climate variables related to evaporative demand, energy release component, temperature, and wind speed, on the dynamics of large fires and megafires in the western US. Our findings highlight the importance of assessing the structural integrity of models in addition to their accuracy. They also underscore the critical need to address the rise in compound climate extremes linked to large wildfires.

54 ENVIRONMENTAL SCIENCES↗

Charge Management for an Inductively Charged On-Demand Battery-Electric Shuttle Service with High Penetration of Renewable Energy

This paper presents a charge management control strategy for an on-demand battery-electric shuttle van operating at the National Renewable Energy Laboratory (NREL) campus and supported by day-time inductive charging at the vehicle's waiting spot. A new control algorithm has been proposed for reducing the demand charge costs incurred from wireless charging of the on-demand shuttle. A custom controller has been developed to monitor the shuttle, wireless charger, renewable energy generation, and various loads at NREL's campus, and regulate charging behavior for demand response. The intermittent renewable generation and sporadic operation of the on-demand shuttle service contribute to a high level of uncertainty in expected campus load profile, which must be carefully managed. The control algorithm predicts energy profile to estimate the mobility needs of the vehicle and maintain uninterrupted service during operation while still minimizing peak demand. The proposed controller has been designed and optimized using a Simulink model for the entire system. Next, it has been implemented and tested in real-time on the NREL campus. Two primary vehicle-use cases, charge sustaining and charge depletion operation, are tested under different load profiles and drive cycles to assess the controller's effectiveness at reducing peak demand and therefore demand charges. The proposed controller showed robust performance under different driving scenarios with high correlation between simulated and experimental data. The results showed that proper demand response can be achieved with an average of 94% reduction of charging loads during peak demand events.

ADVANCED PROPULSION SYSTEMS,ENERGY STORAGE↗

End-Use Savings Shapes Upgrade Package Documentation: Wall and Roof Insulation and New Windows

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) upgrade measures, or upgrades. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility upgrade applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on an upgrade package of three end-use savings shapes upgrades - Window Replacement, Exterior Wall Insulation, and Roof Insulation, which we will refer to collectively as the "High Efficiency Envelope" package. More details on the individual upgrades can be found on the ComStock Measures Documentation page. An upgrade package applies two or more EUSS upgrades to a single building model simulation. Since ComStock is a bottom-up physics-based model, an upgrade package will go beyond aggregating or summing the individual upgrade results and produce novel results by simulating interactions between the upgrades. For example, pairing an envelope upgrade with an electrification upgrade would likely result in higher savings results than the sum of these upgrades individually, and the size of the heating, ventilating, and air conditioning (HVAC) equipment may be reduced if the envelope upgrade reduces the loads significantly.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

End-Use Savings Shapes Upgrade Package Documentation: LED Lighting, HP-RTU and ASHP-Boiler

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) upgrade measures, or upgrades. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility upgrade applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on an upgrade package of three end-use savings shapes upgrades - Light Emitting Diode (LED) Lighting, Heat Pump Rooftop Unit (RTU) (HP-RTU), and Air-Source Heat Pump (ASHP) Boiler, which we will refer to collectively as the "Interior Lighting and Heat Pump" package. More details on the individual upgrades can be found on the ComStock Measures Documentation page. An upgrade package applies two or more EUSS upgrades to a single building model simulation. Since ComStock is a bottom-up physics-based model, an upgrade package will go beyond aggregating or summing the individual upgrade results and produce novel results by simulating interactions between the upgrades. For example, pairing an envelope upgrade with an electrification upgrade would likely result in higher savings results than the sum of these upgrades individually, and the size of the heating, ventilating, and air conditioning (HVAC) equipment may be reduced if the envelope upgrade reduces the loads significantly.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Modeling Tool to Analyze the Performance of Industrial Cooling Towers

Energy efficiency and energy savings have become an important factor as industries look for ways to save energy and minimize their energy consumption while reducing their carbon footprint. Cooling towers are utilized significantly in industries for either serving chillers or process cooling. Depending on the size of the cooling tower, it can use a surprising amount of energy and water, which is why it is crucial to make sure that the facility has optimized their cooling tower.A modeling tool has been developed to perform a thorough analysis of a cooling tower and its various operations to ensure that the facility has optimized its cooling tower. This model analyzes an annual base case in comparison with the revised case of a cooling tower operation. This modeling tool simulates 8,760 hourly calculations for fan power for various fan controls, water consumption, and pumping energy consumption and demand based on the user’s location and its corresponding Typical Meteorological Year 3 (TMY3) weather data. This model is capable to simulate up to five cooling tower cells as one large tower utilizing one pump or parallel pumping. The successful validated cooling tower model should assist industry to save energy at their facility through their cooling tower, whether they use it for process cooling or heating, ventilation and air conditioning (HVAC) applications. The entering/leaving water temperatures based on a monthly operating schedule or a wet-bulb temperature schedule will be used as inputs, and the model can calculate savings in energy for various conditions including variable-frequency drive (VFD) on the fan/pump, drift eliminators, number of cycles of concentration, reduced water flow rate, etc.

Hooper, Josh↗

Geophysical Constraints on Decarbonized Systems—Building Spatio-Temporal Uncertainties into Future Electricity Grid Planning

Future electricity grids will be characterized by the high penetration of renewables to support the decarbonization process. Yet, this transition will further expose grids to a broad spectrum of geophysical forces, such as weather and climate, land and space, minerals and materials. Understanding their role is thus important to support the grid decarbonization process. Here, we synthesize the current body of knowledge on the relationship between geophysical constraints and electricity grid planning. Additionally, we show that there have been promising advances in the data, methods, and modelling tools needed to incorporate the effect of geophysical constraints on demand, resource availability, and grid operations. There are, however, multiple research avenues that deserve further attention. More system-specific and finer-scale analyses are necessary to better understand how spatio-temporal variability---and associated uncertainty---in geophysical forces affect grid planning. Moreover, we need a broader focus on the multi-sectoral implications of grid decarbonization efforts, so as to limit the risk of unintended consequences. Importantly, all these efforts are challenged by the computational requirements of existing power system models, which often limit our ability to characterize uncertainty, scale analyses across larger domains, or study the multi-sector implications of grid expansion decisions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Projecting Electric Vehicle Electricity Demands and Charging Loads

After over a century of petroleum dominance, electric vehicles are rapidly disrupting the transportation energy landscape. At the same time, the electric power systems are undergoing profound changes as variable renewables replace dispatchable fossil generators. It is critically important to understand how transportation electrification will impact electricity demand, including changes in the load shapes that characterize the system, and the value of flexible electric vehicle charging to better balance electricity demand and supply. This talk focuses on methods to project electricity demand for EV charging with high spatiotemporal fidelity to enable electricity system modeling and analysis and summarizes results from recent NREL studies in this area.

ADVANCED PROPULSION SYSTEMS,ENERGY PLANNING, POLIC↗