Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “coverage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Selectivity of Chemisorbed Oxygen in C–H Bond Activation and CO Oxidation and Kinetic Consequences for CH₄–O₂ Catalysis on Pt and Rh Clusters

Rate measurements, density functional theory (DFT) within the framework of transition state theory, and ensemble-averaging methods are used to probe oxygen selectivities, defined as the reaction probability ratios for O* reactions with CO and CH₄, during CH₄–O₂ catalysis on Pt and Rh clusters. CO₂ and H₂O are the predominant products, but small amounts of CO form as chemisorbed oxygen atoms (O*) are depleted from cluster surfaces. Oxygen selectivities, measured using ¹²CO–¹³CH₄–O₂ reactants, increase with O₂/ CO ratio and O* coverage and are much larger than unity at all conditions on Pt clusters. These results suggest that O* reacts much faster with CO than with CH₄, causing any CO that forms and desorbs from metal cluster surfaces to react along the reactor bed with other O* to produce CO₂ at any residence time required for detectable extents of CH₄ conversion. O* selectivities were also calculated by averaging DFTderived activation barriers for CO and CH₄ oxidation reactions over all distinct surface sites on cubo-octahedral Pt clusters (1.8 nm diameter, 201 Pt atoms) at low O* coverages, which are prevalent at low O₂ pressures during catalysis. CO oxidation involves non-activated molecular CO adsorption as the kinetically relevant step on exposed Pt atoms vicinal of chemisorbed O* atoms (on *–O* site pairs). CH₄ oxidation occurs via kinetically relevant C–H bond activation on *–* site pairs involving oxidative insertion of a Pt atom into one of the C–H bonds in CH₄, forming a three-centered HC₃–Pt–H transition state. C–H bond activation barriers reflect the strength of Pt–CH₃ and Pt–H interactions at the transition state, which correlates, in turn, with the Pt coordination and with CH₃ * binding energies. Ensemble-averaged O* selectivities increase linearly with O₂/CO ratios, which define the O* coverages, via a proportionality constant. The proportionality constant is given by the ratio of rate constants for O₂ dissociation and C–H bond activation elementary steps; the values for this constant are much larger than unity and are higher on larger Pt clusters (1.8–33 nm) at all temperatures (573–1273 K) relevant for CH₄–O₂ reactions. The barriers for the kinetically relevant C–H bond dissociation step increase, while those for CO oxidation remain unchanged as the Pt coordination number and cluster size increase, and lead, in turn, to higher O* selectivities on larger Pt clusters. Oxygen selectivities were much larger on Rh than Pt, because the limiting reactants for CO oxidation were completely consumed in ¹²CO–¹³CH₄–O₂ mixtures, consistent with lower CO/O₂ ratios measured by varying the residence time and O₂/CH₄ ratio independently in CH₄–O₂ reactions. These mechanistic assessments and theoretical treatments for O* selectivity provide rigorous evidence of low intrinsic limits of the maximum CO yields, thus confirming that direct catalytic partial oxidation of CH₄ to CO (and H₂) does not occur at the molecular scale on Pt and Rh clusters. CO (and H₂) are predominantly formed upon complete O₂ depletion from the sequential reforming steps.

Environmental Molecular Sciences Laboratory↗

Oxide-catalyzed self- and cross-condensation of cycloketones. Kinetically relevant steps that determine product distribution

Metal oxides with acid-base properties can be used to catalyze aldol condensation and potentially obtain valuable chemicals from biomass-derived oxygenates. Understanding the reaction mechanisms could enable the development of effective catalysts with controllable selectivity. In this work, we investigate the reaction parameters that affect the kinetics and product distribution of self- and cross-aldol condensation of cyclopentanone (CPO) and cyclohexanone (CHO) over CeO 2 and ZrO 2 catalysts by combining detailed analysis of experiments and DFT calculations. It is well-known that either the deprotonation of an α-C–H that generates an enolate or the C–C coupling that produces the dimers can be rate-limiting step. Indeed, the detailed kinetics analysis shows that the observed data can be fitted by unimolecular or bimolecular Langmuir-Hinshelwood models. Specifically, on the ZrO 2 catalyst, the unimolecular α-C–H activation is the rate limiting step for the CPO self-condensation, while the bimolecular C–C coupling limits the CHO self-condensation. By contrast, on CeO 2 , the bimolecular C–C coupling step seems to be rate-limiting for both CPO and CHO self-condensation reactions. The adsorption parameters derived from kinetics fitting indicate that when the two reactants are co-fed, the surface is preferentially covered by CHO. So, the condensation rate of [CPO]-activated products ([CPO]CPO + [CPO]CHO) decreases in the presence of CHO, due to the competitive adsorption. However, despite a higher surface coverage, CHO is not an effective electrophile because it imposes stronger steric constraints to the formation of the C–C bond than CPO. Therefore, for a given enolate, the product distribution shows that [CPO]CPO > [CPO]CHO and, similarly [CHO]CPO > [CHO]CHO. Likewise, the yields of [CPO]- and [CHO]-activated products in mixed CPO/CHO feeds are similar because the higher surface coverage and stability of the [CHO] enolate is counterbalanced by the inhibition of C–C coupling by steric constraints when CHO is involved. In summary, the overall rank of products observed experimentally can be explained in terms of a combination of the following effects: relative surface coverage of the reactants, steric constraints for the C–C coupling, stability of the enolate, and effectiveness of the electrophile to accept an electron.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Consequences of adsorbate-adsorbate interactions for apparent kinetics of surface catalytic reactions

Lateral adsorbate interactions at catalyst surfaces are known to influence adsorption energies and reaction rates. Lattice-based kinetic Monte Carlo (kMC) simulations are able to capture these influences, but such models are typically parameterized for a specific reaction network and catalyst surface. Here we report kMC simulations to probe the influence of lateral interactions on simulated rates, rate orders, apparent activation energies, and Sabatier plots. We construct a simple, two-step reaction network involving a single adsorbate and rate- limiting diatomic dissociation, employ a generic repulsive lateral interaction model consistent with known adsorbate-adsorbate interactions on metal surfaces, and a rate model consistent with known Brønsted-Evans-Polyani relationships for diatomic dissocations. Furthermore, we juxtapose reaction kinetics over a wide range of reaction conditions and catalyst binding energies, as a function of interaction strength. We find that at a given zero-coverage binding energy and external conditions, adsorbate coverage decreases monotonically with increasing interaction strength, but absolute rates can vary linearly or nonlinearly. Interactions flatten the Sabatier volcano and shift the maximum towards stronger binding. Influences on apparent rate orders and activation energies are modest and are sensitive to interaction-induced adsorbate ordering. Model predictions are sensitive to lattice size effects at high coverages. The results, modelled for a simple reaction system, highlight the generic consequences of lateral interactions and guidance for identifying their signatures in observed kinetics.

kinetic Monte Carlo↗

Neutron reflectivity study of substrate surface chemistry effects on supported phospholipid bilayer formation on (1120) sapphire.

Oxide-supported phospholipid bilayers (SPBs) used as biomimetric membranes are significant for a broad range of applications including improvement of biomedical devices and biosensors, and in understanding biomineralization processes and the possible role of mineral surfaces in the evolution of pre-biotic membranes. Continuous-coverage and/or stacjed SPBs retain properties (e.,g. fluidity) more similar to native biological membranes, which is desirable for most applications. Using neutron reflectivity, we examined face coverage and potential stacking of dipalmitoylphosphatidylcholine (DPPC) bilayers on the (1120) face of sapphire (a-Al2O3). Nearly full bilayers were formed at low to neutral pH, when the sapphire surface is positively charged, and at low ionic strength (l=15 mM NaCl). Coverage decreased at higher pH, close to the isoelectric point of sapphire, and also at high I>210mM, or with addition of 2mM Ca2+. The latter two effects are additive, suggesting that Ca2+ mitigates the effect of higher I. These trends agree with previous results for phospholipid adsorption on a-Al2O3 particles determined by adsorption isotherms and on single-crystal (1010) sapphire by atomic force microscopy, suggesting consistency of oxide surface chemistry-dependent effects across experimental techniques.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Engineering surface segregation of perovskite oxide through wet exsolution for CO catalytic oxidation

Cation segregation occurring near the surface or interfaces of solid catalysts plays an important role in catalytic reactions. Unfortunately, the native surface of perovskite oxides is dominated by passivated A-site segregation, which severely hampers the catalytic activity and durability of the system. To address this issue, we present a wet exsolution method to reconstruct surface segregation in perovskite cobalt oxide. Here, under reduction etching treatment of glycol solution, inert surface Sr segregation was transformed into active Co 3 O 4 segregation. By varying the reaction time, we achieved differing coverage of the active Co 3 O 4 segregation on the La 0.5 Sr 0.5 CoO 3-δ (LSCO) perovskite oxide surface. This study reveals that CO oxidation activity exhibits a volcano-shaped dependence on the coverage of Co 3 O 4 segregation at the surface of a perovskite cobalt oxide. Furthermore, we find that a suitable coverage of Co 3 O 4 segregation can dramatically improve the catalytic activity of the perovskite catalyst by enhancing interface interactions. Co K-edge, Co L-edge, and O K-edge X-ray absorption spectra confirm that the synergistic effect optimizes the covalence of the metal-oxygen bond at the surface and interface. This work not only contributes to the design of perovskite-type catalysts, but also provides important insight into the relationship between surface segregation and catalytic activity.

36 MATERIALS SCIENCE↗

Effects of Intergranular Gas Bubbles on Thermal Conductivity

Model microstructures obtained from phase-field simulations are used to study the effective heat transfer across bicrys- tals with stationary grain boundary bubble populations. We find that the grain boundary coverage, irrespective of the intergranular bubble radii, is the most relevant parameter to the thermal resistance, which we use to derive effec- tive Kapitza resistances that are dependent on the grain boundary coverage and Kaptiza resistance of the intact grain boundary. We propose a model to predict thermal conductivity as a function of porosity, grain-size, Kaptiza resistance of the intact grain boundary, and grain boundary bubble coverage.

36 MATERIALS SCIENCE↗

Phase-field simulations of intergranular fission gas bubble behavior in U 3 Si 2 nuclear fuel

U 3 Si 2 is a potential accident-tolerant fuel that shows promise due to its high thermal conductivity and higher uranium density relative to UO 2 . However, its swelling and fission gas release behavior in light water reactor (LWR) conditions is relatively unknown. To provide mechanistic insight and determine parameters for engineering-scale fuel performance modeling of pellet-form U 3 Si 2 , phase-field simulations of the growth, interconnection, and venting of intergranular fission gas bubbles were performed. The fractional coverage of the grain boundary and the fraction of bubble area that is vented were calculated as a function of time. From the simulation data, the fractional grain boundary coverage at saturation, an important parameter needed in engineering-scale modeling of swelling and fission gas release, was determined. Multiple simulations were run to determine the uncertainty in the calculated value. Finally, the effect of model assumptions and input parameters that are not well known was evaluated. Simulation results are compared to related theoretical and computational work. Based on the simulation results, a value of 0.60 for the fractional grain boundary coverage at saturation is recommended for U 3 Si 2 fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Ag adsorption on Cd-terminated CdS (0 0 0 1) and S-terminated CdS (0 0 0 1-bar) surfaces: First-principles investigations

First-principles calculations are performed to study the adsorption of Ag at Cd-terminated CdS (0 0 0 1) and S-terminated CdS (0 0 0 1-bar) surfaces as a function of Ag coverage. Our results reveal that Ag adsorption at Cd-terminated (0 0 0 1) has a large binging energy than at S-terminated (0 0 0 1-bar) surface. For Ag adsorption at Cd-terminated (0 0 0 1) surface, T4 structure is more favorable and the Ag-Cd bond posses an ionic-like character. While for Ag adsorption at S-terminated (0 0 0 1-bar) surface, the H3 structure is most stable and the bonding between Ag-S is covalent. It is found that the magnitude and the sign of surface dipole moment are partly determined by the difference between the electronegativities of Ag and the host atom bonding with Ag. The adsorption energy changes as a function of Ag coverage. In addition, related properties of Ag cluster adsorption at Cd-terminated (0 0 0 1) surface are also discussed. -- Graphical abstract: We studied the adsorption of Ag at Cd-terminated CdS (0 0 0 1) and S-terminated CdS (0 0 0 1-bar) surfaces as a function of Ag coverage by means of the first-principles calculations. In addition, related properties of Ag cluster adsorption at Cd-terminated (0 0 0 1) surface are also discussed. Our ab initio calculations are useful complement to the intense experimental studies for Ag-CdS interface. Display Omitted Research highlights: {yields} Ag adsorption effects on electronic structure and associated physics properties of CdS is systemically studied. {yields} The surface dipole moment is partly determined by the difference between the electronegativities of silver and the host atom bonding with silver. {yields} The characteristic of Ag cluster (Ag{sub 2}, Ag{sub 4}, and Ag{sub 7}) adsorption on the CdS (0 0 0 1) surface is discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Split-Volume Treatment Planning of Multiple Consecutive Vertebral Body Metastases for Cyberknife Image-Guided Robotic Radiosurgery

Cyberknife treatment planning of multiple consecutive vertebral body metastases is challenging due to large target volumes adjacent to critical normal tissues. A split-volume treatment planning technique was developed to improve the treatment plan quality of such lesions. Treatment plans were generated for 1 to 5 consecutive thoracic vertebral bodies (CVBM) prescribing a total dose of 24 Gy in 3 fractions. The planning target volume (PTV) consisted of the entire vertebral body(ies). Treatment plans were generated considering both the de novo clinical scenario (no prior radiation), imposing a dose limit of 8 Gy to 1 cc of spinal cord, and the retreatment scenario (prior radiation) with a dose limit of 3 Gy to 1 cc of spinal cord. The split-volume planning technique was compared with the standard full-volume technique only for targets ranging from 2 to 5 CVBM in length. The primary endpoint was to obtain best PTV coverage by the 24 Gy prescription isodose line. A total of 18 treatment plans were generated (10 standard and 8 split-volume). PTV coverage by the 24-Gy isodose line worsened consistently as the number of CVBM increased for both the de novo and retreatment scenario. Split-volume planning was achieved by introducing a 0.5-cm gap, splitting the standard full-volume PTV into 2 equal length PTVs. In every case, split-volume planning resulted in improved PTV coverage by the 24-Gy isodose line ranging from 4% to 12% for the de novo scenario and, 8% to 17% for the retreatment scenario. We did not observe a significant trend for increased monitor units required, or higher doses to spinal cord or esophagus, with split-volume planning. Split-volume treatment planning significantly improves Cyberknife treatment plan quality for CVBM, as compared to the standard technique. This technique may be of particular importance in clinical situations where stringent spinal cord dose limits are required.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Technical and Dosimetric Considerations in Multi-Isocenter Intensity Modulated Radiotherapy for Nasopharyngeal carcinoma with Small Multileaf Collimator

Multileaf collimator (MLC)-assisted intensity modulated radiotherapy (IMRT) has greatly improved the target coverage and avoidance of organs at risk (OAR) for the treatment of nasopharyngeal carcinoma; however, its implementation is also constrained by the features of the MLC. Nasopharyngeal carcinoma tends to have a large gross target volume (GTV) and clinical target volume (CTV) due to its biological characteristics. More than one isocenter may be needed when small MLCs (i.e., BrainLAB M3, whose largest field is 10 x 10 cm{sup 2}) are used to treat the nasopharyngeal carcinoma. The BrainLAB IMRT system was used to evaluate the effectiveness of a multi-isocenter IMRT plan for treating nasopharyngeal cancers. Dose coverage of GTVs and CTVs were compared among IMRT plans with 1, 2 and 3 isocenters, as were dose objectives for OARs including brainstem, cord, and parotids. The dosimetric variation and the delivery time were also measured with a phantom. IMRT plans with more than 1 isocenter achieved a better dose coverage, homogeneity, and conformity on GTVs and CTVs; however, with risk of higher doses given to OARs. In most cases, one can generate satisfactory IMRT plans using the 2-isocenter IMRT planning strategy. Two-isocenter planning strategy may be a suitable compromise when more isocenters are needed.

61 RADIATION PROTECTION AND DOSIMETRY↗

IMRT vs. 3D Noncoplanar Treatment Plans for Maxillary Sinus Tumors: A New Tool for Quantitative Evaluation

We compared 9-field, equispaced intensity modulated radiation therapy (IMRT), 4- to 5-field, directionally optimized IMRT, and 3-dimensional (3D) noncoplanar planning approaches for tumors of the maxillary sinus. Ten patients were planned retrospectively to compare the different treatment techniques. Prescription doses were 60 to 70 Gy. Critical structures contoured included optic nerves and chiasm, lacrimal glands, lenses, and retinas. As an aid for plan assessment, we introduced a new tool: Critical Organ Scoring Index (COSI), which allows quantitative evaluation of the tradeoffs between target coverage and critical organ sparing. This index was compared with other, commonly used conformity indices. For a reliable assessment of both tumor coverage and dose to critical organs in the different planning techniques, we introduced a 2D, graphical representation of COSI vs. conformity index (CI). Dose-volume histograms and mean, maximum, and minimum organ doses were also compared. IMRT plans delivered lower doses to ipsilateral structures, but were unable to spare them. 3D plans delivered less dose to contralateral structures, and were more homogeneous, as well. Both IMRT approaches gave similar results. In cases where choice of optimal plan was difficult, the novel 2D COSI-CI representation gave an accurate picture of the tradeoffs between target coverage and organ sparing, even in cases where other conformity indices failed. Due to their unique anatomy, maxillary sinus tumors may benefit more from a noncoplanar approach than from IMRT. The new graphical representation proposed is a quick, visual, reliable tool, which may facilitate the physician's choice of best treatment plan for a given patient.

61 RADIATION PROTECTION AND DOSIMETRY↗

Characteristics of Movement-Induced Dose Reduction in Target Volume: A Comparison Between Photon and Proton Beam Treatment

We compared the main characteristics of movement-induced dose reduction during photon and proton beam treatment, based on an analysis of dose-volume histograms. To simulate target movement, a target contour was delineated in a scanned phantom and displaced by 3 to 20 mm. Although the dose reductions to the target in the 2 treatment systems were similar for transverse (perpendicular to beam direction) target motion, they were completely different for longitudinal (parallel to beam direction) target motion. While both modalities showed a relationship between the degree of target shift and the reduction in dose coverage, dose reduction showed a strong directional dependence in proton beam treatment. Clinical simulation of target movement for a prostate cancer patient showed that, although coverage and conformity indices for a 6-mm lateral movement of the prostate were reduced by 9% and 16%, respectively, for proton beam treatment, they were reduced by only 1% and 7%, respectively, for photon treatment. This difference was greater for a 15-mm target movement in the lateral direction, which lowered the coverage and conformity indices by 34% and 54%, respectively, for proton beam treatment, but changed little during photon treatment. In addition, we found that the equivalent uniform dose (EUD) and homogeneity index show similar characteristics during target movement. These results suggest that movement-induced dose reduction differs significantly between photon and proton beam treatment. Attention should be paid to the target margin in proton beam treatment due to the distinct characteristics of heavy ion beams.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric Comparison of Split Field and Fixed Jaw Techniques for Large IMRT Target Volumes in the Head and Neck

Some treatment planning systems (TPSs), when used for large-field (>14 cm) intensity-modulated radiation therapy (IMRT), create split fields that produce excessive multiple-leaf collimator segments, match-line dose inhomogeneity, and higher treatment times than nonsplit fields. A new method using a fixed-jaw technique (FJT) forces the jaw to stay at a fixed position during optimization and is proposed to reduce problems associated with split fields. Dosimetric comparisons between split-field technique (SFT) and FJT used for IMRT treatment is presented. Five patients with head and neck malignancies and regional target volumes were studied and compared with both techniques. Treatment planning was performed on an Eclipse TPS using beam data generated for Varian 2100C linear accelerator. A standard beam arrangement consisting of nine coplanar fields, equally spaced, was used in both techniques. Institutional dose-volume constraints used in head and neck cancer were kept the same for both techniques. The dosimetric coverage for the target volumes between SFT and FJT for head and neck IMRT plan is identical within {+-}1% up to 90% dose. Similarly, the organs at risk (OARs) have dose-volume coverage nearly identical for all patients. When the total monitor unit (MU) and segments were analyzed, SFT produces statistically significant higher segments (17.3 {+-} 6.3%) and higher MU (13.7 {+-} 4.4%) than the FJT. There is no match line in FJT and hence dose uniformity in the target volume is superior to the SFT. Dosimetrically, SFT and FJT are similar for dose-volume coverage; however, the FJT method provides better logistics, lower MU, shorter treatment time, and better dose uniformity. The number of segments and MU also has been correlated with the whole body radiation dose with long-term complications. Thus, FJT should be the preferred option over SFT for large target volumes.

61 RADIATION PROTECTION AND DOSIMETRY↗

Bowel sparing in pediatric cranio-spinal radiotherapy: a comparison of combined electron and photon and helical TomoTherapy techniques to a standard photon method

The aim of this study was to compare the dose to organs at risk (OARs) from different craniospinal radiotherapy treatment approaches available at the Northern Centre for Cancer Care (NCCC), with a particular emphasis on sparing the bowel. Method: Treatment plans were produced for a pediatric medulloblastoma patient with inflammatory bowel disease using 3D conformal 6-MV photons (3DCP), combined 3D 6-MV photons and 18-MeV electrons (3DPE), and helical photon TomoTherapy (HT). The 3DPE plan was a modification of the standard 3DCP technique, using electrons to treat the spine inferior to the level of the diaphragm. The plans were compared in terms of the dose-volume data to OARs and the nontumor integral dose. Results: The 3DPE plan was found to give the lowest dose to the bowel and the lowest nontumor integral dose of the 3 techniques. However, the coverage of the spine planning target volume (PTV) was least homogeneous using this technique, with only 74.6% of the PTV covered by 95% of the prescribed dose. HT was able to achieve the best coverage of the PTVs (99.0% of the whole-brain PTV and 93.1% of the spine PTV received 95% of the prescribed dose), but delivered a significantly higher integral dose. HT was able to spare the heart, thyroid, and eyes better than the linac-based techniques, but other OARs received a higher dose. Conclusions: Use of electrons was the best method for reducing the dose to the bowel and the integral dose, at the expense of compromised spine PTV coverage. For some patients, HT may be a viable method of improving dose homogeneity and reducing selected OAR doses.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric implications of residual seminal vesicle motion in fiducial-guided intensity-modulated radiotherapy for prostate cancer

To determine whether residual interfraction seminal vesicle (SV) displacement necessitates specific planning target volume (PTV) margins during fiducial-guided intensity modulated radiation therapy (IMRT) of the prostate. A planning computed tomography (CT) scan and 2 subsequent CT scans were prospectively obtained for 20 prostate cancer patients with intraprostatic fiducial markers. After CT registration, SV displacement relative to the prostate was quantified as a function of margin size for both the proximal (1 cm) SV (PSV) and the full SV (FSV). Two IMRT plans were simulated for each patient (prostate + PSV and prostate + FSV) both with a uniform 5-mm PTV margin. Minimum clinical target volume (CTV) dose (D{sub min}) and the volume of SV receiving 95% of the prescription dose (V{sub 95%}) were assessed during treatment and compared with the initial plan. In all cases, SV displacement with respect to the prostate was greater for the FSV compared with the PSV. To ensure at least 95% geometrical coverage of the CTV for 90% of patients, margins of 5 and 8 mm were required for the PSV and FSV, respectively. Dosimetrically, residual SV displacement had minimal impact on PSV coverage compared with FSV coverage. For the PSV D{sub min} was {>=}95% of the prescribed dose in 90% of patients with an overall mean V{sub 95%} of 99.6 {+-} 0.8%; for the FSV D{sub min} was {>=}95% of the prescribed dose in only 45% of patients with a mean V{sub 95%} of 97.9 {+-} 2.4%. The SVs move differentially from the prostate and exhibit greater variation with increasing distance from the prostate. For plans targeting just the prostate and PSVs, 5-mm PTV expansions are adequate. However, despite daily localization of the prostate, larger PTV margins are required for cases where the intent is to completely cover the FSV.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric comparison of metastatic spinal photon treatment techniques

Traditional palliative treatment of metastatic cancer to the vertebral bodies often results in doses to the spinal cord that are higher than the dose prescribed to the target, or gross tumor volume (GTV). This study compares traditional techniques of spine palliation with intensity-modulated radiation therapy (IMRT). The purpose of the study is 2-fold: first, the study demonstrates the benefits of using IMRT to lower the dose to the organs at risk (OAR), particularly for the spinal cord and other nonspecified normal tissues; second, the article provides information regarding the advantages and disadvantages of commonly used conventional techniques for treating the vertebral bodies based on patient anatomy. Because the use of IMRT or other advanced techniques may be prohibitive because of insurance issues, treatment plans were created that compared optimal coverage vs. optimal sparing for single-field, wedged-pair, and opposed-beam arrangements. Fifty-five patients were selected and divided by location of target (cervical, thoracic, and lumbar spine) and also by the measured separation between the anterior and posterior surface of the patient at the level of mid-GTV. Within each anatomic category the patients again were divided into the categories of small, medium, and large based on separation. The patient dataset that most closely represented the average separation within each category was selected, resulting in a total of 9 patients, and the appropriate treatment plan techniques were calculated for each of the 9 patients. The results of the study do show that the use of IMRT is far superior when compared with other techniques, both for coverage and for sparing of the surrounding tissue, regardless of patient size and the section of spine being treated. Based on a combination of both target coverage and sparing of normal tissues, the conventional plan of choice may vary by both the section of spine to be treated and by the size of the patient.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric comparison between model 9011 and 6711 sources in prostate implants

The purpose of this work is to evaluate the model 9011 iodine-125 ({sup 125}I) in prostate implants by comparing dosimetric coverage provided by the 6711 vs 9011 source implants. Postimplant dosimetry was performed in 18 consecutively implanted patients with prostate cancer. Two were implanted with the 9011 source and 16 with the 6711 source. For purposes of comparison, each implant was then recalculated assuming use of the other source. The same commercially available planning system was used and the specific source data for both 6711 and 9011 products were entered. The results of these calculations are compared side by side in the terms of the isodose values covering 100% (D100) and 90% (D90) of prostate volume, and the percentages of volumes of prostate, bladder, rectum, and urethra covered by 200% (V200), 150% (V150), 100% (V100), 50% (V50), and 20% (V20) of the prescribed dose as well. The 6711 source data overestimate coverage by 6.4% (ranging from 4.9% to 6.9%; median 6.6%) at D100 and by 6.6% (ranging from 6.2% to 6.8%; median 6.6%) at D90 compared with actual 9011 data. Greater discrepancies of up to 67% are seen at higher dose levels: average reduction for V100 is 2.7% (ranging from 0.6% to 7.7%; median 2.3%), for V150 is 14.6% (ranging from 6.1% to 20.5%; median 15.3%), for V200 is 14.9% (ranging from 4.8% to 19.1%; median 16%); similarly seen in bladder, rectal, and urethral coverage. This work demonstrates a clear difference in dosimetric behavior between the 9011 and 6711 sources. Using the 6711 source data for 9011 source implants would create a pronounced error in dose calculation. This study provides evidence that the 9011 source can provide the same dosimetric quality as the 6711 source, if properly used; however, the 6711 source data should not be considered as a surrogate for the 9011 source implants.

61 RADIATION PROTECTION AND DOSIMETRY↗

An optimized posterior axillary boost technique in radiation therapy to supraclavicular and axillary lymph nodes: A comparative study

To assess the advantages of an optimized posterior axillary (AX) boost technique for the irradiation of supraclavicular (SC) and AX lymph nodes. Five techniques for the treatment of SC and levels I, II, and III AX lymph nodes were evaluated for 10 patients selected at random: a direct anterior field (AP); an anterior to posterior parallel pair (AP-PA); an anterior field with a posterior axillary boost (PAB); an anterior field with an anterior axillary boost (AAB); and an optimized PAB technique (OptPAB). The target coverage, hot spots, irradiated volume, and dose to organs at risk were evaluated and a statistical analysis comparison was performed. The AP technique delivered insufficient dose to the deeper AX nodes. The AP-PA technique produced larger irradiated volumes and higher mean lung doses than the other techniques. The PAB and AAB techniques originated excessive hot spots in most of the cases. The OptPAB technique produced moderate hot spots while maintaining a similar planning target volume (PTV) coverage, irradiated volume, and dose to organs at risk. This optimized technique combines the advantages of the PAB and AP-PA techniques, with moderate hot spots, sufficient target coverage, and adequate sparing of normal tissues. The presented technique is simple, fast, and easy to implement in routine clinical practice and is superior to the techniques historically used for the treatment of SC and AX lymph nodes.

61 RADIATION PROTECTION AND DOSIMETRY↗