At least 775 records · Page 43

Operation and performance of VRF systems: Mining a large-scale dataset

The energy consumption of air-conditioning systems has gained increasing attention as it contributes significantly to the global building energy use. The variable refrigerant flow (VRF) system is a common air-conditioning system applied widely in residential and office buildings in China. Understanding the actual operation and performance of VRF systems is fundamental for the energy-efficient design and operation of VRF systems. Previous research on VRF system operation used either limited field data covering certain building types and climate zones or used a questionnaire to obtain a larger dataset. However, they did not capture the wide applications of VRF systems quantitatively across all building types, climate zones, and operating conditions. To fill this gap, statistical and clustering analysis was conducted on the newly proposed key performance indicators of approximately 287,000 VRF systems for residential and commercial buildings in all five climate zones in China. In this work, the main findings are: (1) VRF systems are mainly used for cooling in all climate zones in China; (2) among all building types, the duration of use is lowest in residential buildings and highest in hotels and medical buildings; (3) the distribution of the ideal VRF cooling coefficient of performance (COP) is similar across all climate zones and building types; whereas the COPs of ideal VRF heating in the Severe Cold region and Cold regions are lower than those in other climate zones; and (4) partial load operations for VRF systems are common in residential buildings and office buildings due to the part-time-part-space operation mode. These findings can inform the actual application of VRF systems in China, supporting the design, operation, industry standard development, and performance optimization of VRF systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Desiccants enabling energy-efficient buildings: A review

Buildings account for about 39% of the total energy consumption in the United States. Developing highly energy-efficient and environmentally friendly systems that are either actively or passively integrated into buildings plays a crucial role in decarbonizing the building sector. Among various technologies, desiccant-based energy systems have received particular attention in recent years due to their unique advantages, such as being thermally driven using low-grade waste or solar energies and being reliable over a wide range of operating ranges. Extensive research efforts have been exerted on desiccant-enabled technologies at both material and system levels aiming to increase their performance and achieve high technological readiness levels. The present review paper comprehensively discusses research works made at the system level. It overviews desiccant-based air conditioning systems, desiccant-based humidity pumps, desiccant-based thermal energy storage systems, and desiccant-based appliances. The study identifies challenges and opportunities to accelerate the commercialization of desiccant-enabled technologies. It is found that desiccant materials offer great promise to improve energy efficiency and functionality of future buildings through decoupling the latent and sensible cooling loads in air conditioning systems, humidity pumps integrated into building facades, and next-generation appliances. However, commercial viability and widespread acceptance of desiccant-based systems have been hampered by several major obstacles, including liquid and air flow mal-distribution and inferior thermo-physical properties of desiccant materials resulting in low ab/adsorption and regeneration rates and bulky/costly systems.

25 ENERGY STORAGE↗

Experimental Validation of a High-Temperature Test Facility for Future Additive Manufactured Supercritical Carbon Dioxide Turbine Testing

For next-generation power plants to achieve high cycle efficiencies consistent with the Department of Energy's 65% efficiency target, turbomachinery capable of operating within high-temperature power cycles must be demonstrated. Pairing additively manufactured superalloy turbines with the supercritical carbon dioxide (sCO 2 ) power cycle could enable turbine inlet temperatures approaching 1300 °C while providing flexibility in turbine cooling strategies. Development of test facilities to characterize and validate such systems is crucial. In this study, a turbine test facility capable of achieving inlet conditions of 800 °C, 11 MPa, and 0.43 kg/s while accommodating complex auxiliary cooling flow requirements has been designed and constructed to support future testing of a Haynes 282 additively manufactured 30 kW turbine-generator system with advanced cooling channels. This facility enables characterization of aerodynamic performance, leakage, and windage losses. Details of the facility's construction and operation are presented, along with experimental validation tests using an orifice as an expansion device in place of the turbine. These tests confirm that the facility can reach the required conditions, distinguish regions of achievable steady and pseudo-steady conditions, and identify the heater power required for each point in the upcoming turbine campaign. The campaign confirmed that ISO 5167-2 can reliably predict orifice mass flow rates in extreme supercritical carbon dioxide conditions with deviations of 0.5–7.5%.

42 ENGINEERING↗

Key Nuclear Data Impacting Reactivity in Advanced Reactors

Advanced reactor concepts currently being developed throughout the industry are significantly different from light water reactor (LWR) designs with respect to geometry, materials, and operating conditions, and consequently, with respect to their reactor physics behavior. Given the limited operating experience with non-LWRs, the accurate simulation of reactor physics and the quantification of associated uncertainties are critical for ensuring that advanced reactor concepts operate within the appropriate safety margins. Nuclear data are a major source of input uncertainties in reactor physics analysis. As part of an ongoing project at Oak Ridge National Laboratory (ORNL), the effects of nuclear data uncertainties on key figures of merit associated with advanced reactor safety are being assessed for selected advanced reactor technologies. Key nuclear data relevant for reactor safety analysis for each selected advanced reactor technology were identified, and their impact on important key figures of merit was assessed. Available advanced reactor specifications were reviewed, results from studies performed at ORNL and other research institutions were consulted, and available evaluated nuclear data libraries were analyzed. This report summarizes the key nuclear data for nuclides in the fuel, as well as other significant data, including scattering and neutron capture in various materials for the moderator, coolant, and structure of the considered advanced reactors. For the considered advanced reactors that use low-enriched uranium (LEU) fuel, results from LWR studies provided insight into relevant nuclear data given the lack of available studies specifically addressing these new systems. The major nominal missing data that were identified consist of thermal scattering data and 135m Xe cross section data for molten salt reactor (MSR) analysis. The identified major gaps with respect to nuclear data uncertainties are missing uncertainties of thermal scattering data for high temperature gas-cooled reactors and moderated MSR systems, and incomplete uncertainties on angular distributions in particular for fast spectrum systems, such as sodiumcooled fast reactors, fast molten salt reactors, and heat pipe reactors. Furthermore, it was found that special attention should be paid to cross section and uncertainty differences between different evaluated nuclear data library releases, because significant differences in nuclear data that can lead to major differences in reactivity calculations were found, even for well-known nuclides.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Inline gamma-spectrometry of fission product elements after rapid high-pressure ion chromatographic separation

Analysis of irradiated material shortly after irradiation can be non-trivial due to highly radioactive activation and fission isotopes increasing dead time in gamma-ray detection systems, often requiring a “cooling-period” between receipt of a sample and the subsequent analysis. A direct separation–detection method has been developed combining ion chromatography and inductively coupled mass spectrometry for rapid, low-level analysis of fission products; it cannot, however, detect certain short-lived species below the detection limit of the system. In this paper we report the implementation of an inline gamma-ray detector, which was added post-separation, pre-analysis, to test the quality and utility of elementally-isolated gamma-ray spectroscopy.

Inline gamma-ray detection↗

An experimental study of the behavior of a high efficiency residential heat pump in cooling mode with common installation faults imposed

Faults are believed to be common in split system air-conditioner and heat pump systems, due to operating degradation or installation problems. Common faults include improper refrigerant charge, reduced evaporator airflow, liquid line restrictions, and the presence of non-condensable gas. Laboratory tests were used to quantify fault impacts on performance of a heat pump system, and impacts on indicator variables such as refrigerant temperatures and pressures. This paper describes a large set of laboratory tests implemented on a high efficiency heat pump operating in cooling mode. This system uses R-410A refrigerant and has a rotary compressor, TXV, two accumulators, and a compensator. A small number of previous experimental studies have been done previously to study the effects of some operating faults, but none has examined a modern system with these components. The tests were conducted with a range of fault intensities and driving conditions. The results are compared to previous researchers’ experimental results. The system’s performance was found to be quite robust in the presence of faults. The TXV, accumulators, and compensator significantly reduce sensitivity to refrigerant charge and liquid line restriction faults, and other faults to a lesser extent.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Kibble–Zurek mechanism of Ising domains

The formation of topological defects after a symmetry-breaking phase transition is an overarching phenomenon that encodes the underlying dynamics. The Kibble-Zurek mechanism (KZM) describes these non-equilibrium dynamics of second-order phase transitions and predicts a power-law relationship between the cooling rates and the density of topological defects. It has been verified as a successful model in a wide variety of physical systems, including structure formation in the early Universe and condensed-matter materials. However, it is uncertain if the KZM mechanism is also valid for topologically trivial Ising domains, one of the most common and fundamental types of domain in condensed-matter systems. Here we show that the cooling rate dependence of Ising domain density follows the KZM power law in two different three-dimensional structural Ising domains: ferro-rotation domains in NiTiO 3 and polar domains in BiTeI. However, although the KZM slope of NiTiO 3 agrees with the prediction of the 3D Ising model, the KZM slope of BiTeI exceeds the theoretical limit, providing an example of steepening KZM slope with long-range dipolar interactions. Finally, our results demonstrate the validity of KZM for Ising domains and reveal an enhancement of the power-law exponent for transitions of non-topological quantities with long-range interactions. The Kibble-Zurek mechanism is shown to apply to structural Ising domains in three-dimensional materials. Long-range interactions modify the critical exponents away from theoretical predictions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Performance evaluation of an air conditioning system based on quasi isothermal dehumidifcation

This work presents a first study of novel air conditioning system based on quasi isothermal dehumidification combined with dew-point evaporative cooling through the Maisotsenko cycle (M-Cycle). The dehumidification process is realized in desiccant coated heat exchanger with heat rejection system. The key idea behind the solution is to maximize the cooling effectiveness by creating favourable conditions for dehumidification and evaporative cooling process. This is achieved by rejecting the heat of sorption in the desiccant system and providing cold and dry air for M-Cycle air cooler, which allows the system to be powered by using low-grade heat energy at 50 °C. The analysis is performed on the basis of experimentally validated numerical models of each component combined in a unified model of the system. The goal of the study is to determine the performance of the solution under different operational conditions. In addition two types of M-Cycle air coolers (i.e. cross-flow and regenerative unit) are compared to establish which unit is more suitable as the source of cooling energy for the system. It was established that proposed system is able to provide comfortable room parameters (supply air temperature equal 17 °C and humidity ratio equal 0.010 kg/kg-da) for outdoor air temperatures ranging from 28 to 36 °C and outdoor air humidity ranging from 0.010 to 0.018 kg/kg-da. This means that the proposed solution is able to provide comfortable conditions in temperate and humid climates. Results also indicate that the system consisting of the regenerative M-Cycle HMX allows better cooling load management, offers higher thermal Coefficient of Performance (COP th ) and uses less water compared to the system with the cross-flow HMX. However, the system with cross-flow heat and mass exchanger (HMX) has a relatively greater electrical Coefficient of Performance (COP el ) in most cases.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Timed to save: the added value of accounting for hourly incidence of electricity savings from residential space-conditioning measures

Abstract Previous research has recognized that the value of measures that reduce electricity usage depends upon the timing of the savings generated, but the lack of hourly savings shapes has limited the demonstration of this concept. We develop empirical hourly savings shapes for residential space-conditioning measures from nearly 18,000 efficiency projects in California and show how they combine with the diurnal and seasonal variation in electricity system costs. We find that these measures (cooling replacements; windows, doors, and skylights; and other envelope measures) tend to save electricity when system costs are highest and that the hourly savings account for 1.4–1.5 times as much value as non-time-sensitive estimates of efficiency would predict. We present these impact multipliers for each measure to quantify the additional value revealed by the time-sensitive approach. We show that this additional value is similar in an evolving electricity grid with storage, rather than natural gas generation, as the marginal resource.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Generic Behavior of Ultrastability and Anisotropic Molecular Packing in Codeposited Organic Semiconductor Glass Mixtures

Vapor-deposited glass mixtures of organic semiconductors commonly serve as active layers in organic electronic devices, whose lifetime and performance are strongly influenced by the stability and structure of these mixed glasses. Here, we study the stability and anisotropic molecular packing of six co-deposited organic semiconductor glass mixtures with 50:50 weight ratio, by differential scanning calorimetry and spectroscopic ellipsometry. We also find that all six binary systems exhibit high kinetic stability and significantly reduced enthalpy relative to the corresponding liquid-cooled glassy mixtures (ultrastable behavior), even for systems where the glass transition temperatures of the components differ by more than 90 K. Furthermore, we demonstrate that the birefringence of a co-deposited glass mixture, a measure of its anisotropic packing, can be predicted from the birefringence of glasses of the two pure components. These results for stability and structure are expected to be applicable to other co-deposited organic semiconductor glass mixtures, so long as the two components mix well in the glass and individually can form ultrastable glasses. Therefore, our findings are significant for designing novel electronic devices with enhanced device lifetime and increased operational efficiency.

36 MATERIALS SCIENCE↗

Comparative study of decay heat calculations with FLUKA and MCNP/CINDER2008

In designing a high-power tungsten target, decay heat driven temperature rise in the spallation volume is a safety concern during maintenance and in loss of coolant accidents. As tungsten hydrates and becomes volatile in steam at above 800 ◦C, it is important to keep the target temperature below this threshold when active cooling is unavailable. Decay heat in a target is calculated with particle transport simulation codes combined with transmutation codes. The calculated decay heat usually differs depending on the nuclear cross sections and the decay particle transport models built in the code architecture. In this paper, we calculated decay heat of a water-cooled tungsten target using popular particle transport codes, FLUKA and MCNP6® paired with CINDER2008 and compared the results. The target-moderator-reflector (TMR) system is modeled with a water-cooled solid tungsten target, water premoderators, liquid hydrogen cold moderators and beryllium reflectors. Water-cooled stainless-steel shielding is modeled around the TMR system. The tungsten volume is clad with a thin layer of erosion/corrosion resistant material. This study provides information about the uncertainty range in decay heat prediction of high-power spallation targets for hazard analysis.

Lee, Yong Joong↗

SCALE Analyses of Scenarios in the High-Temperature Gas-Cooled Reactor Fuel Cycle

This report demonstrates the SCALE code system’s capabilities in modeling and simulating scenarios in the High-Temperature Gas-cooled Reactor (HTGR) nuclear fuel cycle as part of a United States Nuclear Regulatory Commission (NRC) project that aims to demonstrate the capabilities of the SCALE and MELCOR codes for non-light water reactor (non-LWR) modeling and simulation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Machine learning based simultaneous control of air handling unit discharge air and condenser water temperatures set-point for minimized cooling energy in an office building

In this study, an artificial intelligence based real-time prediction and control model to optimize condenser water temperature and discharge air temperature (DAT) set-points in water-cooled air handling unit (AHU) system has been developed. EnergyPlus-MATLAB co-simulation has been conducted to analyze the developed model's effectiveness. Here, to develop artificial neural networks (ANN) model, embedded neural network objects in MATLAB was utilized. The developed model could decide an optimal temperature set-points based on outdoor air wet-bulb temperature to reflect the Korean climate context. As a result, the developed ANN prediction model showed the predictive performance of Cv(RMSE) of approximately 21%. Compared to the conventional fixed temperature algorithm, which fixes AHU DAT at 14°C and condenser water temperature at 32°C, the ANN based optimized control showed a 22% total cooling energy reduction. These results show that significant energy savings can be achieved by simultaneously controlling condenser water temperature and AHU DAT set-points considering Korean climatic characteristics using AI technologies such as ANN models.

24 POWER TRANSMISSION AND DISTRIBUTION↗

RELAP5-3D Capabilities for High-Temperature Gas-Cooled Reactor Analysis

RELAP5-3D is the premier systems thermal-hydraulic code in the world. The code has been used significantly for high-temperature gas-cooled reactor (HTGR) analyses over the last 10 years, but there has not been a comprehensive summary of RELAP5-3D capabilities and methods for HTGR modeling. In this paper, we provide a guide for how novice users can build models for prismatic HTGRs. This guide includes best practices for developing heat structures and setting up radiation and conduction heat transfer. We also provide a summary of relevant validation studies. These studies are divided into three categories: separate effects tests, integral effects tests, and nuclear reactor studies. We present a comprehensive review of RELAP5-3D HTGR applications for reactor modeling over the last 10 years. These applications include work for the Modular High-Temperature Gas-Cooled Reactor benchmark, design activities for a prismatic HTGR as part of the U.S. Department of Energy’s Advanced Demonstration and Test Reactor Options Study, and studies performed to design gas-cooled microreactors. Following the comprehensive literature review, we present a gap analysis highlighting capabilities of RELAP5-3D that are available and missing for a complete analysis of HTGR thermal hydraulics. We also discuss the limitations of existing code capabilities and potential improvements that could improve analyses. Current research efforts have yet to fully validate RELAP5-3D for a prismatic HTGR analysis; however, some of this is attributable to confounding factors in the available experimental data as opposed to code capabilities. In conclusion, this paper presents the most comprehensive review to date on RELAP5-3D capabilities, limitations, and applications for HTGR analysis.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Giant Outer Transiting Exoplanet Mass (GOT ‘EM) Survey. II. Discovery of a Failed Hot Jupiter on a 2.7 Yr, Highly Eccentric Orbit

Radial velocity (RV) surveys have discovered giant exoplanets on au-scale orbits with a broad distribution of eccentricities. Those with the most eccentric orbits are valuable laboratories for testing theories of high-eccentricity migration. However, few such exoplanets transit their host stars, thus removing the ability to apply constraints on formation from their bulk internal compositions. We report the discovery of Kepler-1704 b, a transiting 4.15 M {sub J} giant planet on a 988.88 day orbit with an extreme eccentricity of 0.921{sub -0.015}{sup +0.010}. Our decade-long RV baseline from the Keck I telescope allows us to measure the orbit and bulk heavy-element composition of Kepler-1704 b and place limits on the existence of undiscovered companions. A failed hot Jupiter, Kepler-1704 b was likely excited to high eccentricity by scattering events that possibly began during its gas accretion phase. Its final periastron distance was too large to allow for tidal circularization, so now it orbits its host from distances spanning 0.16–3.9 au. The maximum difference in planetary equilibrium temperature resulting from this elongated orbit is over 700 K. A simulation of the thermal phase curve of Kepler-1704 b during periastron passage demonstrates that it is a remarkable target for atmospheric characterization from the James Webb Space Telescope, which could potentially also measure the planet’s rotational period as the hot spot from periastron rotates in and out of view. Continued characterization of the Kepler-1704 system promises to refine theories explaining the formation of hot Jupiters and cool giant planets like those in the solar system.

47 OTHER INSTRUMENTATION↗

Thermal Insulation for a High Temperature Molten Salt Storage Tank in a CSP Plant

A ternary molten chloride has been suggested as a high temperature (550-720 °C) sensible heat storage medium for a two-tank system. An effective thermal insulation is proposed to provide an opportunity for the fabrication of both the hot and cold storage tanks from lower cost metals, e.g. A240-347H, by maintaining the tank wall below 500 °C. To achieve this, the hot storage tank mainly comprises of inner shell (11.4 cm of a refractory brick as liner (KX-99®), 30 cm of insulation brick) and outer metal shell, where 5 cm of frozen layer of PCM800 (NaCl), and 5 cm of ceramic wool fill the annular space between the shells. Another layer of ceramic wool was introduced at the outer side of the metal shell to keep the temperature lower than 60 °C. ANSYS Fluent was used for the numerical study of the cool down behavior of the system during idle period when tank is quarter-filled. The heat transfer modes were considered as radiation and natural convection heat transfer from the hot molten salt at 720 °C, conduction through the solid layers and convection heat transfer from the outer shell to the environment at 15 °C. The results showed that the proposed insulation system including a frozen layer of PCM800 maintains the temperature at the metal wall lower than 500 °C, and lower than 60°C at the outer side of the tank. Apart from the insulation property of the frozen layer of PCM800, it absorbs any leak of hot molten salt, acting as a barrier between salt and the metal shell. The thermal performance analysis provide an insight into the benefits of the multilayer insulation.

41 EE - Solar Energy Technologies Office (EE-4S)↗