Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “concurrent”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Reducing Communication in Graph Neural Network Training

Graph Neural Networks (GNNs) are powerful and flexible neural networks that use the naturally sparse connectivity information of the data. GNNs represent this connectivity as sparse matrices, which have lower arithmetic intensity and thus higher communication costs compared to dense matrices, making GNNs harder to scale to high concurrencies than convolutional or fully-connected neural networks. Here, we introduce a family of parallel algorithms for training GNNs and show that they can asymptotically reduce communication compared to previous parallel GNN training methods. We implement these algorithms, which are based on 1D, 1. 5D, 2D, and 3D sparse-dense matrix multiplication, using torch.distributed on GPU-equipped clusters. Our algorithms optimize communication across the full GNN training pipeline. We train GNNs on over a hundred GPUs on multiple datasets, including a protein network with over a billion edges.

97 MATHEMATICS AND COMPUTING↗

Analysis of Threading Libraries for High Performance Computing

With the appearance of multi-/many core machines, applications and runtime systems have evolved in order to exploit the new on-node concurrency brought by new software paradigms. POSIX threads (Pthreads) was widely-adopted for that purpose and it remains as the most used threading solution in current hardware. Lightweight thread (LWT) libraries emerged as an alternative offering lighter mechanisms to tackle the massive concurrency of current hardware. In this article, we analyze in detail the most representative threading libraries including Pthread- and LWT-based solutions. In addition, to examine the suitability of LWTs for different use cases, we develop a set of microbenchmarks consisting of OpenMP patterns commonly found in current parallel codes, and we compare the results using threading libraries and OpenMP implementations. Moreover, we study the semantics offered by threading libraries in order to expose the similarities among different LWT application programming interfaces and their advantages over Pthreads. This article exposes that LWT libraries outperform solutions based on operating system threads when tasks and nested parallelism are required.

GLT↗

NSTX-U Advances in Real-Time C++11 on Linux

Programming languages like C and Ada combined with proprietary embedded operating systems have dominated the real-time application space for decades. The new C++11standard includes native, language-level support for concurrency, a required feature for any nontrivial event-oriented real-time software. Threads, Locks, and Atomics now exist to provide the necessary tools to build the structures that make up the foundation of a complex real-time system. The National Spherical Torus Experiment Upgrade (NSTX-U) at the Princeton Plasma Physics Laboratory (PPPL) is breaking new ground with the language as applied to the needs of fusion devices. A new Digital Coil Protection System (DCPS) will serve as the main protection mechanism for the magnetic coils, and it is written entirely in C++11 running on Concurrent Computer Corporation's real-time operating system, RedHawk Linux. It runs over 600 algorithms in a 5 kHz control loop that determine whether or not to shut down operations before physical damage occurs. To accomplish this, NSTX-U engineers developed software tools that do not currently exist elsewhere, including real-time atomic synchronization, real-time containers, and a real-time logging framework. Together with a recent (and carefully configured) version of the GCC compiler, these tools enable data acquisition, processing, and output using a conventional operating system to meet a hard real-time deadline (that is, missing one periodic is a failure) of 200 microseconds.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analyzing the Performance Trade-Off in Implementing User-Level Threads

User-level threads have been widely adopted as a means of achieving lightweight concurrent execution without the costs of OS-level threads. Nevertheless, the costs of managing user-level threads represent a performance barrier that dictates how fine grained the concurrency exposed by an application can be without incurring significant overheads; this in turn may translate into insufficient parallelism to exploit highly parallel systems. This article is a deep dive into the fundamental costs in implementing user-level threads. We first identify that one of the highest sources of fork-join overheads stems from deviations, events that incur context switching during the execution of a thread and disrupt a run-to-completion execution. We then conduct an in-depth investigation of a wide spectrum of methods with respect to how they handle deviations while covering both parent- and child-first scheduling policies. Our methodology involves a comprehensive instruction- and cache-level analysis of all methods on several modern CPU architectures. Finally, the primary finding of our evaluation is that dynamic promotion methods that assume the absence of deviation and dynamically provide context-switching support offer the best trade-off between performance and capability when the likelihood of deviation is low.

97 MATHEMATICS AND COMPUTING↗

Hybrid Parallelism for Volume Rendering on Large-, Multi-, and Many-Core Systems

With the computing industry trending towards multi- and many-core processors, we study how a standard visualization algorithm, ray-casting volume rendering, can benefit from a hybrid parallelism approach. Hybrid parallelism provides the best of both worlds: using distributed-memory parallelism across a large numbers of nodes increases available FLOPs and memory, while exploiting shared-memory parallelism among the cores within each node ensures that each node performs its portion of the larger calculation as efficiently as possible. We demonstrate results from weak and strong scaling studies, at levels of concurrency ranging up to 216,000, and with datasets as large as 12.2 trillion cells. The greatest benefit from hybrid parallelism lies in the communication portion of the algorithm, the dominant cost at higher levels of concurrency. We show that reducing the number of participants with a hybrid approach significantly improves performance.

97 MATHEMATICS AND COMPUTING↗

Phosphorus alleviation of nitrogen‐suppressed methane sink in global grasslands

Abstract Grassland ecosystems account for more than 10% of the global CH 4 sink in soils. A 4‐year field experiment found that addition of P alone did not affect CH 4 uptake and experimental addition of N alone significantly suppressed CH 4 uptake, whereas concurrent N and P additions suppressed CH 4 uptake to a lesser degree. A meta‐analysis including 382 data points in global grasslands corroborated these findings. Global extrapolation with an empirical modelling approach estimated that contemporary N addition suppresses CH 4 sink in global grassland by 11.4% and concurrent N and P deposition alleviates this suppression to 5.8%. The P alleviation of N‐suppressed CH 4 sink is primarily attributed to substrate competition, defined as the competition between ammonium and CH 4 for the methane mono‐oxygenase enzyme. The N and P impacts on CH 4 uptake indicate that projected increases in N and P depositions might substantially affect CH 4 uptake and alter the global CH 4 cycle.

Zhang, Lihua↗

Manganese sulfide formation via concomitant microbial manganese oxide and thiosulfate reduction.

The dissimilatory metal-reducing bacterium, Shewanella oneidensis MR-1 produced γ-MnS (rambergite) nanoparticles under the concurrent reduction of synthetic MnO 2 and thiosulfate coupled to H 2 oxidation. Using two MR-1 mutants defective in outer membrane c-type cytochromes (ΔmtrC/ΔomcA and ΔmtrC/ΔomcA/ΔmtrF) to eliminate the direct reduction pathway for solid electron acceptors, it was determined that respiratory reduction of MnO 2 was dominant relative to chemical reduction by biogenic sulfide generated from bacterial thiosulfate reduction. Although bicarbonate was excluded from the medium, incubations of MR-1 using lactate as the sole electron donor produced MnCO 3 (rhodochrosite) as well as MnS in nearly equivalent amounts as estimated by micro X-ray diffraction (micro-XRD) analysis. It was concluded that carbonate released from lactate metabolism promoted MnCO 3 formation and that Mn(II) mineralogy was strongly affected by carbonate ions even in the presence of abundant sulfide and weakly alkaline conditions that favor the precipitation of MnS. Formation of the biogenic MnS, as determined by a combination of micro-XRD, transmission electron microscopy, energy dispersive X-ray spectroscopy, and selected area electron diffraction analyses was consistent with equilibrium speciation modeling predictions. Although biogenic MnS likely only forms and is stable over a relatively narrow range of conditions, it may be a significant sink for Mn in anoxic marine basins and terrestrial subsurface sediments where Mn and sulfur compounds are undergoing concurrent reduction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Estimating uncertainty: A Bayesian approach to modelling photosynthesis in C3 leaves

The Farquhar-von Caemmerer-Berry (FvCB) model is extensively used to model pho-tosynthesis from gas exchange measurements. Since its publication, many methods have been developed to measure, or more accurately estimate, parameters of this model. Here, we have created a tool that uses Bayesian statistics to fit photosyn-thetic parameters using concurrent gas exchange and chlorophyll fluorescence mea-surements whilst evaluating the reliability of the parameter estimation. We have tested this tool on synthetic data and experimental data from rice leaves. Our results indicate that reliable parameter estimation can be achieved whilst only keeping one parameter, Km, that is, Michaelis constant for CO2 by Rubisco, prefixed. Additionally, we show that including detailed low CO2 measurements at low light levels increases reliability and suggests this as a new standard measurement protocol. By providing an estimated distribution of parameter values, the tool can be used to evaluate the quality of data from gas exchange and chlorophyll fluorescence measurement proto-cols. Compared to earlier model fitting methods, the use of a Bayesian statistics-based tool minimizes human interaction during fitting, reducing the subjectivity which is essential to most existing tools. A user friendly, interactive Bayesian tool script is provided.

Bayesian statistics, leaf photosynthesis, mesophyl↗

Evaluating Optimization Strategies for Engine Simulations Using Machine Learning Emulators

This work evaluates different optimization algorithms for computational fluid dynamics (CFD) simulations of engine combustion. Due to the computational expense of CFD simulations, emulators built with machine learning algorithms were used as surrogates for the optimizers. Two types of emulators were used: a Gaussian process (GP) and a weighted variety of machine learning methods called SuperLearner (SL). The emulators were trained using a dataset of 2048 CFD simulations that were run concurrently on a supercomputer. The design of experiments (DOE) for the CFD runs was obtained by perturbing nine input parameters using a Monte-Carlo method. The CFD simulations were of a heavy duty engine running with a low octane gasoline-like fuel at a partially premixed compression ignition mode. Ten optimization algorithms were tested, including types typically used in research applications. Each optimizer was allowed 800 function evaluations and was randomly tested 100 times. The optimizers were evaluated for the median, minimum, and maximum merits obtained in the 100 attempts. Some optimizers required more sequential evaluations, thereby resulting in longer wall clock times to reach an optimum. The best performing optimization methods were particle swarm optimization (PSO), differential evolution (DE), GENOUD (an evolutionary algorithm), and micro-genetic algorithm (GA). These methods found a high median optimum as well as a reasonable minimum optimum of the 100 trials. Moreover, all of these methods were able to operate with less than 100 successive iterations, which reduced the wall clock time required in practice. Two methods were found to be effective but required a much larger number of successive iterations: the DIRECT and MALSCHAINS algorithms. A random search method that completed in a single iteration performed poorly in finding optimum designs but was included to illustrate the limitation of highly concurrent search methods. The last three methods, Nelder–Mead, bound optimization by quadratic approximation (BOBYQA), and constrained optimization by linear approximation (COBYLA), did not perform as well.

Probst, Daniel M.↗

New Mechanism for Yield Point Phenomena

Yield point phenomena (YPP) are widely attributed to discrete dislocation locking by solute atmospheres. An alternate YPP mechanism was recently suggested by simulations of Ta single crystals without any influence of solutes or discrete dislocations. The general meso-scale (GM) simulations consist of crystal plasticity (CP) plus accounting for internal stresses of geometrically necessary dislocation content. GM predicted the YPP while CP did not, suggesting a novel internal stress mechanism. The predicted YPP varied with crystal orientation and boundary conditions, contrary to expectations for a solute mechanism. The internal stress mechanism was probed by experimentally deforming oligocrystal Ta samples and comparing the results with independent GM simulations. Strain distributions of the experiments were observed with high-resolution digital image correlation. A YPP stress–strain response occurred in the 0–2% strain range in agreement with GM predictions. Shear bands appeared concurrent with the YPP stress–strain perturbation in agreement with GM predictions. At higher strains, the shear bands grew at progressively slower rates in agreement with GM predictions. It was concluded that the internal stress mechanism can account for the existence of YPP in a wide variety of materials including ones where interstitial-dislocation interactions and dislocation transient avalanches are improbable. Furthermore, the internal stress mechanism is a CP analog of various micro-scale mechanisms of discrete dislocations such as pile-up or bow-out. It may operate concurrently with strain aging, or either mechanism may operate alone. A suggestion was made for a future experiment to answer this question.

42 ENGINEERING↗

Telerobotic system concept for real-time soft-tissue imaging during radiotherapy beam delivery

Purpose: The curative potential of external beam radiation therapy is critically dependent on having the ability to accurately aim radiation beams at intended targets while avoiding surrounding healthy tissues. However, existing technologies are incapable of real-time, volumetric, soft-tissue imaging during radiation beam delivery, when accurate target tracking is most critical. The authors address this challenge in the development and evaluation of a novel, minimally interfering, telerobotic ultrasound (U.S.) imaging system that can be integrated with existing medical linear accelerators (LINACs) for therapy guidance. Methods: A customized human-safe robotic manipulator was designed and built to control the pressure and pitch of an abdominal U.S. transducer while avoiding LINAC gantry collisions. A haptic device was integrated to remotely control the robotic manipulator motion and U.S. image acquisition outside the LINAC room. The ability of the system to continuously maintain high quality prostate images was evaluated in volunteers over extended time periods. Treatment feasibility was assessed by comparing a clinically deployed prostate treatment plan to an alternative plan in which beam directions were restricted to sectors that did not interfere with the transabdominal U.S. transducer. To demonstrate imaging capability concurrent with delivery, robot performance and U.S. target tracking in a phantom were tested with a 15 MV radiation beam active. Results: Remote image acquisition and maintenance of image quality with the haptic interface was successfully demonstrated over 10 min periods in representative treatment setups of volunteers. Furthermore, the robot's ability to maintain a constant probe force and desired pitch angle was unaffected by the LINAC beam. For a representative prostate patient, the dose-volume histogram (DVH) for a plan with restricted sectors remained virtually identical to the DVH of a clinically deployed plan. With reduced margins, as would be enabled by real-time imaging, gross tumor volume coverage was identical while notable reductions of bladder and rectal volumes exposed to large doses were possible. The quality of U.S. images obtained during beam operation was not appreciably degraded by radiofrequency interference and 2D tracking of a phantom object in U.S. images obtained with the beam on/off yielded no significant differences. Conclusions: Remotely controlled robotic U.S. imaging is feasible in the radiotherapy environment and for the first time may offer real-time volumetric soft-tissue guidance concurrent with radiotherapy delivery.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric and thermal properties of a newly developed thermobrachytherapy seed with ferromagnetic core for treatment of solid tumors

Purpose: Studies of the curative effects of hyperthermia and radiation therapy on treatment of cancer show a strong evidence of a synergistic enhancement when both radiation and hyperthermia modalities are applied simultaneously. Varieties of tissue heating approaches developed up to date still fail to overcome such essential limitations as an inadequate temperature control, temperature nonuniformity, and prolonged time delay between hyperthermia and radiation treatments. The authors propose a new self-regulating thermobrachytherapy seed, which serves as a source of both radiation and heat for concurrent administration of brachytherapy and hyperthermia. Methods: The proposed seed is based on the BEST Medical, Inc., Seed Model 2301-I{sup 125}, where tungsten marker core and the air gap are replaced with a ferromagnetic material. The ferromagnetic core produces heat when subjected to alternating electromagnetic (EM) field and effectively shuts off after reaching the Curie temperature (T{sub C}) of the ferromagnetic material thus realizing the temperature self-regulation. The authors present a Monte Carlo study of the dose rate constant and other TG-43 factors for the proposed seed. For the thermal characteristics, the authors studied a model consisting of 16 seeds placed in the central region of a cylindrical water phantom using a finite-element partial differential equation solver package ''COMSOL Multiphysics.''Results: The modification of the internal structure of the seed slightly changes dose rate and other TG-43 factors characterizing radiation distribution. The thermal modeling results show that the temperature of the thermoseed surface rises rapidly and stays constant around T{sub C} of the ferromagnetic material. The amount of heat produced by the ferromagnetic core is sufficient to raise the temperature of the surrounding phantom to the therapeutic range. The phantom volume reaching the therapeutic temperature range increases with increase in frequency or magnetic field strength. Conclusions: An isothermal distribution matching with the radiation isodose distribution can be achieved within a target volume by tuning frequency and intensity of the alternating magnetic field. The proposed combination seed model has a potential for implementation of concurrent brachytherapy and hyperthermia.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Monte Carlo study for designing a dedicated “D”-shaped collimator used in the external beam radiotherapy of retinoblastoma patients

Purpose: Retinoblastoma is the most common intraocular malignancy in the early childhood. Patients treated with external beam radiotherapy respond very well to the treatment. However, owing to the genotype of children suffering hereditary retinoblastoma, the risk of secondary radio-induced malignancies is high. The University Hospital of Essen has successfully treated these patients on a daily basis during nearly 30 years using a dedicated “D”-shaped collimator. The use of this collimator that delivers a highly conformed small radiation field, gives very good results in the control of the primary tumor as well as in preserving visual function, while it avoids the devastating side effects of deformation of midface bones. The purpose of the present paper is to propose a modified version of the “D”-shaped collimator that reduces even further the irradiation field with the scope to reduce as well the risk of radio-induced secondary malignancies. Concurrently, the new dedicated “D”-shaped collimator must be easier to build and at the same time produces dose distributions that only differ on the field size with respect to the dose distributions obtained by the current collimator in use. The scope of the former requirement is to facilitate the employment of the authors' irradiation technique both at the authors' and at other hospitals. The fulfillment of the latter allows the authors to continue using the clinical experience gained in more than 30 years. Methods: The Monte Carlo codePENELOPE was used to study the effect that the different structural elements of the dedicated “D”-shaped collimator have on the absorbed dose distribution. To perform this study, the radiation transport through a Varian Clinac 2100 C/D operating at 6 MV was simulated in order to tally phase-space files which were then used as radiation sources to simulate the considered collimators and the subsequent dose distributions. With the knowledge gained in that study, a new, simpler, “D”-shaped collimator is proposed. Results: The proposed collimator delivers a dose distribution which is 2.4 cm wide along the inferior-superior direction of the eyeball. This width is 0.3 cm narrower than that of the dose distribution obtained with the collimator currently in clinical use. The other relevant characteristics of the dose distribution obtained with the new collimator, namely, depth doses at clinically relevant positions, penumbrae width, and shape of the lateral profiles, are statistically compatible with the results obtained for the collimator currently in use. Conclusions: The smaller field size delivered by the proposed collimator still fully covers the planning target volume with at least 95% of the maximum dose at a depth of 2 cm and provides a safety margin of 0.2 cm, so ensuring an adequate treatment while reducing the irradiated volume.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-10: A Moving-Blocker-Based Strategy for Simultaneous Megavoltage and Kilovoltage Scatter Correction in Cone-Beam Computed Tomography Image Acquired During Volumetric Modulated Arc Therapy

Purpose: To evaluate a moving-blocker-based approach in estimating and correcting megavoltage (MV) and kilovoltage (kV) scatter contamination in kV cone-beam computed tomography (CBCT) acquired during volumetric modulated arc therapy (VMAT). Methods: XML code was generated to enable concurrent CBCT acquisition and VMAT delivery in Varian TrueBeam developer mode. A physical attenuator (i.e., “blocker”) consisting of equal spaced lead strips (3.2mm strip width and 3.2mm gap in between) was mounted between the x-ray source and patient at a source to blocker distance of 232mm. The blocker was simulated to be moving back and forth along the gantry rotation axis during the CBCT acquisition. Both MV and kV scatter signal were estimated simultaneously from the blocked regions of the imaging panel, and interpolated into the un-blocked regions. Scatter corrected CBCT was then reconstructed from un-blocked projections after scatter subtraction using an iterative image reconstruction algorithm based on constraint optimization. Experimental studies were performed on a Catphan 600 phantom and an anthropomorphic pelvis phantom to demonstrate the feasibility of using moving blocker for MV-kV scatter correction. Results: MV scatter greatly degrades the CBCT image quality by increasing the CT number inaccuracy and decreasing the image contrast, in addition to the shading artifacts caused by kV scatter. The artifacts were substantially reduced in the moving blocker corrected CBCT images in both Catphan and pelvis phantoms. Quantitatively, CT number error in selected regions of interest reduced from 377 in the kV-MV contaminated CBCT image to 38 for the Catphan phantom. Conclusions: The moving-blockerbased strategy can successfully correct MV and kV scatter simultaneously in CBCT projection data acquired with concurrent VMAT delivery. This work was supported in part by a grant from the Cancer Prevention and Research Institute of Texas (RP130109) and a grant from the American Cancer Society (RSG-13-326-01-CCE)

60 APPLIED LIFE SCIENCES↗

SU-E-T-23: A Novel Two-Step Optimization Scheme for Tandem and Ovoid (T and O) HDR Brachytherapy Treatment for Locally Advanced Cervical Cancer

Purpose: To present a novel method allowing fast, true volumetric optimization of T and O HDR treatments and to quantify its benefits. Materials and Methods: 27 CT planning datasets and treatment plans from six consecutive cervical cancer patients treated with 4–5 intracavitary T and O insertions were used. Initial treatment plans were created with a goal of covering high risk (HR)-CTV with D90 > 90% and minimizing D2cc to rectum, bladder and sigmoid with manual optimization, approved and delivered. For the second step, each case was re-planned adding a new structure, created from the 100% prescription isodose line of the manually optimized plan to the existent physician delineated HR-CTV, rectum, bladder and sigmoid. New, more rigorous DVH constraints for the critical OARs were used for the optimization. D90 for the HR-CTV and D2cc for OARs were evaluated in both plans. Results: Two-step optimized plans had consistently smaller D2cc's for all three OARs while preserving good D90s for HR-CTV. On plans with “excellent” CTV coverage, average D90 of 96% (range 91–102), sigmoid D2cc was reduced on average by 37% (range 16–73), bladder by 28% (range 20–47) and rectum by 27% (range 15–45). Similar reductions were obtained on plans with “good” coverage, with an average D90 of 93% (range 90–99). For plans with inferior coverage, average D90 of 81%, an increase in coverage to 87% was achieved concurrently with D2cc reductions of 31%, 18% and 11% for sigmoid, bladder and rectum. Conclusions: A two-step DVH-based optimization can be added with minimal planning time increase, but with the potential of dramatic and systematic reductions of D2cc for OARs and in some cases with concurrent increases in target dose coverage. These single-fraction modifications would be magnified over the course of 4–5 intracavitary insertions and may have real clinical implications in terms of decreasing both acute and late toxicity.

60 APPLIED LIFE SCIENCES↗

SU-E-T-166: Evaluation of Integral Dose in Intensity-Modulated Radiotherapy and Volumetric Modulated Arc Therapy for Head and Neck Cancer Patient

Purpose: Volumetric Modulated Arc Therapy (VMAT) usually achieves higher conformity of radiation doses to targets and less delivery time than Intensity Modulated Radiation Therapy (IMRT). We hypothesized that VMAT will increase integral dose (ID) to patients which will decrease the count of white blood count (WBC) lymphocytes, and consequently has a subsequent impact on the immune system. The purpose of this study is to evaluate the ID to patients undergoing IMRT and VMAT for Head and Neck cancers and its impact on the immune system. Methods: As a pilot study, 30 head and neck patients who received 9-fields IMRT or 3-arcs Radip-Arcbased VMAT were included in this study. Ten of these patients who received the VMAT plans were re-planned using IMRT with the same objectives. ID was calculated for all cases. All patients also had a baseline WBC obtained prior to treatment, and 3 sets of labs drawn during the course of radiation treatment. Results: For the 10 re-planned patients, the mean ID was 13.3 Gy/voxel (range 10.2–17.5 Gy/voxel) for the 9-fields IMRT plans, and was 15.9 Gy/voxel (range 12.4-20.9 Gy/voxel) for the 3-Arc VMAT plan (p=0.01). The integral dose was significant correlated with reducing WBC count during RT even when controlling for concurrent chemotherapy (R square =0.56, p=0.008). Conclusion: Although VMAT can deliver higher radiation dose conformality to targets, this benefit is achieved generally at the cost of greater integral doses to normal tissue outside the planning target volume (PTV). Lower WBC counts during RT were associated with higher Integral doses even when controlling for concurrent chemotherapy. This study is ongoing in our Institution to exam the impact of integral doses and WBC on overall survival.

60 APPLIED LIFE SCIENCES↗

SU-E-T-258: Parallel Optimization of Beam Configurations for CyberKnife Treatments

Purpose: The CyberKnife delivers a large number of beams originating at different non-planar positions and with different orientation. We study how much the quality of treatment plans depends on the beams considered during plan optimization. Particularly, we evaluate a new approach to search for optimal treatment plans in parallel by running optimization steps concurrently. Methods: So far, no deterministic, complete and efficient method to select the optimal beam configuration for robotic SRS/SBRT is known. Considering a large candidate beam set increases the likelihood to achieve a good plan, but the optimization problem becomes large and impractical to solve. We have implemented an approach that parallelizes the search by solving multiple linear programming problems concurrently while iteratively resampling zero weighted beams. Each optimization problem contains the same set of constraints but different variables representing candidate beams. The search is synchronized by sharing the resulting basis variables among the parallel optimizations. We demonstrate the utility of the approach based on an actual spinal case with the objective to improve the coverage. Results: The objective function is falling and reaches a value of 5000 after 49, 31, 25 and 15 iterations for 1, 2, 4, and 8 parallel processes. This corresponds to approximately 97% coverage in 77%, 59%, and 36% of the mean number of iterations with one process for 2, 4, and 8 parallel processes, respectively. Overall, coverage increases from approximately 91.5% to approximately 98.5%. Conclusion: While on our current computer with uniform memory access the reduced number of iterations does not translate into a similar speedup, the approach illustrates how to effectively parallelize the search for the optimal beam configuration. The experimental results also indicate that for complex geometries the beam selection is critical for further plan optimization.

07 ISOTOPE AND RADIATION SOURCES↗

TU-C-17A-12: Towards a Passively Optimized Phase-Space Monte Carlo (POPMC) Treatment Planning Method: A Proof of Principle

Purpose: The advent of on-line/off-line adaptive, and biologically-conformal radiation therapy has led to a need for treatment planning solutions that utilize voxel-specific penalties, requiring optimization over a large solution space that is performed quickly, and the dose in each voxel calculated accurately. This work proposes a “passive” optimization framework, which is executed concurrently during Monte Carlo dose calculation, evaluating the cost/benefit of each history during transport, and creates a passively optimized fluence map. Methods: The Monte Carlo code Geant4 v9.6 was used for this study. The standard voxel geometry implementation was modified to support the passive optimization framework, with voxel-specific optimization parameters. Dose-benefit functions, which will increase a particle history’s weight upon dose deposition, were defined in a central collection of voxels to effectively create target structures. Histories that deposit energy to voxels are reweighted based on a voxel’s dose multiplied by its cost/benefit value. Upon full termination of each history, the dose contributions of that history are reweighted to reflect a contribution proportional to the history’s final weight. A parallel-planar 1.25 MeV photon fluence is transported through the geometry, and re-weighted at each dose deposition step. The resulting weight is tallied with the incident spatial and directional coordinates in a phase-space distribution. Results: A uniform incident fluence was reweighted during MC dose calculations to create an optimized fluence map which would generate dose profiles in target volumes that exhibit the same dose characteristics as the prescribed optimization parameters. An optimized dose profile, calculated concurrently with the phase-space, reflects the resulting dose distribution. Conclusion: This study demonstrated the feasibility of passively optimizing an incident fluence map during Monte Carlo dose calculations. The flexibility of the voxel-specific optimization framework allows a variety and combination of optimization parameters to be calculated for each voxel at every transportation step. This work is partially supported by Varian. This work is partially supported by the NIH.

07 ISOTOPE AND RADIATION SOURCES↗