Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “collimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Method of and means for testing a glancing-incidence mirror system of an X-ray telescope

An apparatus was designed for measuring the resolution and efficiency of a glancing-incidence mirror system having an even number of coaxial and confocal reflecting surfaces for use in an X-ray telescope. A collimated beam of X-rays is generated by an X-ray laser and directed along the axis of the system so that the beam is incident on the reflecting surfaces and illuminates a predetermined area. An X-ray detector, such as a photographic film, is located at the common focus of the surfaces so that the image produced by the X-rays may be compared with a test pattern interposed between the laser and the system.

Dailey, C. C.↗

Evaluation of thallium-201 scanning for detection of latent coronary artery disease

The use of thallium imaging as a noninvasive method to accurately screen shuttle passengers for latent coronary artery disease was investigated. All radionuclide procedures were performed using an Anger type camera with a high resolution collimator. A minimum of 200,000 counts were collected for each image using a 20% window centered on the 69-83 keV X-rays. For the images obtained following injection with the patient at rest, the testing was begun 10 minutes after injection. Injections of TT during exercise were made at a point near the termination of the treadmill procedure as determined by either the appearance of ST segment changes on the electrocardiogram consistant with subendocardial ischemia, the appearance of angina-like chest pain in the patient or fatigue in the patient which required cessation of the test. The severity of heart disease was based on the medical history, physical exam, exercise electrocardiograms, chest X-rays and the coronary arteriogram.

Johnson, P. C.↗

The cosmic X-ray experiment aboard HEAO-1

The HEAO-1 A-2 experiment, designed to study the large scale structure of the galaxy and the universe at X-ray energies is described. The instrument consists of six gas proportional counters of three types nominally covering the energy ranges of 0.15-3 keV, 1.2-20 keV, and 2.5-60 keV. The two low energy detectors have about 400 sq cm open area each while the four others have about 800 sq cm each. Dual field of view collimators allow the unambiguous determination of instrument internal background and diffuse X-ray brightness. Instrument characteristics and early performance are discussed.

Rothschild, R. E.↗

A hard X-ray and gamma ray observation of the 22 November 1977 solar flare

The Franco-Soviet experiment package Signe 2 MP for solar and cosmic X and gamma ray observations, launched aboard a Soviet Prognoz satellite into a highly eccentric earth orbit is described. An uncollimated NaI detector 37 mm thick by 90 mm diameter, placed on the upper surface of the satellite faced the sun. A collimated lateral NaI detector 14 mm thick by 38 mm diameter also faced the sun, and a similar lateral detector faced the anti-solar direction. Data tapes reveal an intense solar flare up to energies of up to 5 MeV, with evidence for line emission at 2.23 MeV and possibly 4.4 MeV. The event observed was associated with the Mc Math Plage Region 15031, and an H-alpha flare of importance 2B. It is not yet clear what radio emission is associated with the X-ray observation.

Chambon, G.↗

Rice University observations of the galactic center

The most sensitive of the four balloon fight observations of the galactic center made by Rice University was conducted in 1974 from Rio Cuarto, Argentina at a float altitude of 4 mbar. The count rate spectrum of the observed background and the energy spectrum of the galactic center region are discussed. The detector used consists of a 6 inch Nal(T 1ambda) central detector collimated to approximately 15 deg FWHM by a Nal(T lamdba) anticoincidence shield. The shield in at least two interaction mean free paths thick at all gamma ray energies. The instrumental resolution is approximately 11% FWHM at 662 keV. Pulses from the central detector are analyzed by two 256 channel PHA's covering the energy range approximately 20 keV to approximately 12 MeV. The detector is equatorially mounted and pointed by command from the ground. Observations are made by measuring source and background alternately for 10 minute periods. Background is measured by rotating the detector 180 deg about the azimuthal axis.

Meegan, C. A.↗

Future directions in experimental gamma ray astronomy

Better vehicles and instruments are needed if gamma ray spectroscopy in astrophysics and cosmology is to advance. A gamma ray observatory will (1) permit long-term observations of selected sources to measure their variability and to achieve high sensitivity; (2) measure periods in days or weeks; and (3) assess the entire sky to observe various predicted sources, to measure the energy spectrum, and to map the isotropy of the cosmic ray background over larger collecting areas (of the order of a square meter). Conventional and unconventional instruments must cover the energy range from 0.1 MeV to 20 MeV with improved sensitivity. Angular resolution must be improved one degree or more to study discrete X-ray sources in the galactic center. Actively collimated detectors, improved double Compton instruments, and gamma ray correlators to actively synthesize the absolute energy spectrum of the sky protons are discussed as well as the need for scientific balloons.

Haymes, R. C.↗

Positions of galactic X-ray sources - Galactic latitudes between zero and 20 deg

Precise (to 20 or 25 arcsec) positions of six X-ray sources located in the galactic bulge are reported which were obtained as part of a survey of the galactic plane performed with the SAS-3 rotating modulation collimators. The sources include GX1+4, GX9+9, GX3+1, GX9+1, GX13+1, and GX17+2. The error radii and X-ray intensities (2 to 11 keV) determined for the sources are also presented along with finding charts and proposed optical and radio counterparts. The results are compared with those of previous satellite and sounding-rocket experiments. The status of each source with respect to optical or radio identifications is briefly discussed.

Doxsey, R. E.↗

Discovery of an X-ray QSO

The discovery of X-ray QSO MR2251-178 at a distance of 410 Mpc is reported. The observations are based on signals (2-11 keV) from NRAO's Very Large Array (VLA) radio telescope and from two independent rotating modulation collimators (RMC). Coordinates are given and positional identification with X-ray source 2A2251-179 is made. Examination of POSS plates and redshift has given rise to speculation that MR2251-178 could actually be a Seyfert galaxy; but its high luminosity would tend to support the contention that it is, indeed, a QSO.

Ricker, G. R.↗

Observation of X-ray eclipses from LMC X-4

Observations made with the Rotation Modulation Collimator system (RMC) have revealed that X-ray source X-4 in the Large Magellanic Cloud (LMC X-4) is most likely part of a binary system. An analysis of the star's coordinates is presented, with attention given to orbital period and flux intensity variations. Stellar mass and orbital inclination angle are estimated for both X-4 and its companion star.

Li, F.↗

The X-ray structure of NGC 5128

During an observation of NGC 5128 (Cen A) by the rotating modulation collimator on board the SAS-3 X-ray observatory in early June 1975, data were obtained which suggest the presence of an extended source with about 3 arcmin FWHM surrounding an extremely compact object located at the radio/IR nucleus. The point component exhibited a 25% increase in intensity over a period of 2 to 5 hours.

Delvaille, J. P.↗

The high-energy celestial X-ray instrument on board OSO-8

The 20 keV-3 MeV celestial X-ray detector on the OSO-8 is described. The primary objectives of this instrument are to measure the energy spectrum of cosmic X-ray sources above 20 keV and to search for time variations, both periodic and irregular, in the intensity of the sources detected. The detector consists of two optically isolated central crystals shielded by a large, active collimator. The sensitive area is 27.5 sq cm and the field-of-view is 5 deg FWHM. The instrument is mounted in the wheel section of OSO-8 with the axis of its field of view offset by 5 deg from the negative spin axis of the wheel. The minimum detectable intensity of a point source which is brought to within 5 deg of the negative spin axis for greater than one day is about 10 to the minus fifth power photons/sq cm-sec at 100 keV.

Dennis, B. R.↗

The HEAO-B Monitor Proportional Counter Instrument

The Monitor Proportional Counter Instrument for the HEAO-B X-ray Telescope satellite is designed to observe celestial X-ray sources in the range of 1 to 20 keV with intensities exceeding .0002 Crab. It provides both spectral and temporal data, to complement the data from the other HEAO-B instruments, to compare with observations from previous flights, as well as to allow detailed study of time variant X-ray phenomena. The basic detector is a large area proportional counter system, consisting of two counters, high voltage power supplies and preamplifiers, mounted behind a collimator with a 2/3 degree square field of view. The signal processing, power distribution and control electronics are contained in a separate unit, which includes circuitry to perform pulse height analysis, background rejection, time interval measurement, redundancy switching and control, housekeeping and telemetry interfacing.

Gaillardetz, R.↗

Imaging of X-ray aurorae from Spacelab

The Atmospheric X-ray Emission Telescope (AXET) is designed to image and measure the spatial, temporal, and spectral distributions of X-ray aurorae produced in the upper atmosphere by precipitating energetic electrons. The bremsstrahlung-produced X radiation penetrates to stratospheric depths where it can modify ozone, conductivity, and other critical atmospheric parameters. Remote sensing of this radiation from topside will provide vital data on solar-terrestrial relationships and mechanisms that could help trigger tropospheric response to solar activity. The X rays also provide direct information concerning the dynamics of radiation-belt processes within the magnetosphere. AXET is designed to detect sources up to 50 keV and to image them below 25 keV by means of directionally sensitive proportional counters with passive collimators. It will be mounted in the Space Shuttle on a single fixed platform designed to optimize viewing conditions for the anticipated orbits and aspects of early Spacelab missions.

Goldberg, R. A.↗

Compact and diffuse X-ray sources in the core of the Perseus cluster /Abell 426/

Data on the X-ray structure of the Perseus cluster of galaxies in the energy range from 2 to 10 keV are analyzed which were obtained during a 12-day observation with the rotating modulation collimator aboard SAS 3. In particular, the nature of the compact X-ray source coincident with NGC 1275 is examined. The data are shown to confirm the presence of a diffuse region of X-ray emission surrounding the nucleus of NGC 1275; it is found that a model which also includes a point source at the nucleus is consistent with the data if the point contribution is no larger than 20% of the X-ray flux detected within 3 to 5 arcmin of the galaxy. The results suggest that NGC 1275 may have accreted a large amount of gas from the intracluster medium and that the flux from the possible point source is consistent with a synchro/Compton model.

Helmken, H.↗

Nova Ophiuchi 1977 - An X-ray nova

This letter reports the observation by the HEAO 1 satellite experiments of the X-ray nova in Ophiuchus discovered by Kaluzienski and Holt (1977), which is designated H1705-25. The SAO/MIT scanning modulation collimator has been used in conjunction with the NRL large-area sky survey to give two possible positions for the X-ray nova, each having errors of 0.3 by 1.8 arcmin. The discovery of a 16.5-magnitude optical nova (Nova Ophiuchi 1977) in one of the error boxes is reported, and the X-ray source is identified with the optical nova. The object is classified as being of the A0620-00 and A1524-61 type; i.e., a low-mass binary system.

Griffiths, R. E.↗

Positions of galactic X-ray sources with l/II/ between -20 deg and +6 deg

The precise positions of nine X-ray sources in the vicinity of the galactic center are reported. The data were obtained as part of the comprehensive survey of the galactic plane performed with the rotating modulation collimator detectors on the SAS-3 X-ray observatory. The sources include the binary X-ray source 4U 1700-37 which has a well established optical counterpart that lies 7 sec from the reported position. The other sources GX 349+2, 4U 1702-42, 4U 1705-44, MX 1716-31, A 1742-294, 4U 1755-33, GX 5-1, and 2S 1803-245 lack established counterparts in other wavelengths. The obtained position for GX 5-1 adds confidence to the radio counterpart proposed by Braes et al. (1972). The reported position for 4U 1755-33 excludes the optical counterpart proposed by Jones et al. (1974).

Jernigan, J. G.↗

Thirty-centimeter-diameter ion milling source

A 30-cm beam diameter ion source has been designed and fabricated for micromachining and sputtering applications. An argon ion current density of 1 mA/cu cm at 500 eV ion energy was selected as a design operating condition. The completed ion source met the design criteria at this operating condition with a uniform and well-collimated beam having an average variation in current density of + or - 5% over the center of 20 cm of the beam. This ion source has a multipole magnetic field that employs permanent magnets between permeable pole pieces. Langmuir probe surveys of the source plasma support the design concepts of a multipole field and a circumferential cathode to enhance plasma uniformity.

Robinson, R. S.↗

Discovery of 3.6-s X-ray pulsations from 4U0115+63

SAS 3 observations reveal a pulsation period of 3.61 sec for the transient X-ray source 4U0115+63. Positional measurement is accurate to approximately 30 arc s, and has led to the likely identification of an optical counterpart. The intensity of the pulses, as reported on 5.9 January 1978, is given as approximately 1.7 times that of the Crab Nebula (1-27 keV). Spectral information was also obtained from the ratios of counting rates in the first three energy channels of the center slat collimator detector (1-27 keV). Two classes of models are proposed to explain the transient nature of the X-ray sources: (1) episodic mass transfer in a binary system, and (2) eccentric binary orbits.

Cominsky, L.↗