Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “clocks”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Characterization of a gigabit transceiver for the ATLAS inner tracker pixel detector readout upgrade

We present a gigabit transceiver prototype Application Specific Integrated Circuit (ASIC), GBCR, for the ATLAS Inner Tracker (ITk) Pixel detector readout upgrade. GBCR is designed in a 65-nm CMOS technology and consists of four upstream receiver channels, a downstream transmitter channel, and an Inter-Integrated Circuit (I2C) slave. The upstream channels receive the data at 5.12 Gbps passing through 5-meter 34-American Wire Gauge (AWG) Twin-axial (Twinax) cables, equalize and retime them with a recovered clock, and then drive an optical transmitter. The downstream channel receives the data at 2.56 Gbps from an optical receiver and drives the cable as same as the upstream channels. The jitter of the upstream channel output is measured to be 35 ps (peak-peak) when the Clock-Data Recovery (CDR) module is turned on and the jitter of the downstream channel output after the cable is 138 ps (peak-peak). The power consumption of each upstream channel is 72 mW when the CDR module is turned on and the downstream channel consumes 27 mW. GBCR survives the total ionizing dose of 200 kGy.

47 OTHER INSTRUMENTATION↗

Design and performance of an in-vacuum, magnetic field mapping system for the Muon g-2 experiment

The Muon g - 2 experiment at Fermilab (E989) aims to measure the anomalous magnetic moment, a μ , of the muon with a precision of 140 parts-per-billion. This requires a precise measurement of both the anomalous spin precession frequency, ω α , of muons stored in a magnetic field of 1.45 T, and a precise measurement of that magnetic field in terms of the shielded proton Larmor frequency, ω' ρ . The measurement of ω' ρ with a total systematic uncertainty of 70 parts-perbillion involves a combination of various nuclear magnetic resonance (NMR) probes. There are 378 probes mounted in fixed locations that constantly monitor field drifts. A water-based, cylindrical calibration probe provides the calibration in terms of the shielded proton Larmor frequency. A crucial element for the multi-step measurement of ω' ρ is the regular mapping of the magnetic field over the muon storage region. The former experiment at Brookhaven National Laboratory (BNL) employed an in-vacuum field mapping system equipped with 17 NMR probes, which was developed by the University of Heidelberg. We have refurbished and upgraded this system with new probes and electronics. The upgrades include the addition of 16-bit, 1 MSPS digitization of the NMR signals, which replaced the hardware-implemented zero-crossing counting of the system at Brookhaven. The digitized signals offer new capabilities in the NMR frequency analysis and its related systematic uncertainties. To sustain the higher data rates, a new communication scheme with time-division multiplexing was implemented to separate the important NMR reference clock from the data communication in order to reach the specifications for the accuracy and stability of the reference clock. A new barcode reader provides more precise azimuthal position determination during the measurement and calibration. While the mechanical systems that move the field mapper inside the storage ring have been mostly refurbished from BNL, the motion control system was completely replaced with a custom-built electronics centered around a commercial Galil motion controller. Both the field mapping NMR system and its motion control were successfully commissioned at Fermilab and have been in reliable operation during the first three data taking periods of the experiment at Fermilab. Finally, this article will provide the details of the upgrades of the field mapper and its performance.

47 OTHER INSTRUMENTATION↗

A sub-picosecond digitally-controlled phase delay

The use of precision timing measurements will be a major tool at the HL-LHC, where it will be used to suppress pile-up and to search for long-lived particles. To control a reference clock with sub-picosecond accuracy, we have fabricated in the TSMC 65 nm process a digitally controlled phase shifter. It is composed of a chain of 66 cells, each with a digitally controlled planar wave guide with either a short or long delay. With this a reference clock’s phase can be controlled to a precision of 200 fs with dynamic range of 12 ps.

Instruments & Instrumentation↗

ETROC1: the first full chain precision timing prototype ASIC for CMS MTD endcap timing layer upgrade

We present the design and characterization of the first fullchain precision timing prototype ASIC, named ETL Readout Chipversion 1 (ETROC1) for the CMS MTD endcap timing layer (ETL)upgrade. The ETL utilizes Low Gain Avalanche Diode (LGAD) sensors todetect charged particles, with the goal to achieve a time resolutionof 40–50 ps per hit, and 30–40 ps per track with hits from twodetector layers. The ETROC1 is composed of a 5 × 5 pixelarray and peripheral circuits. The pixel array includes a4 × 4 active pixel array with an H-tree shaped networkdelivering clock and charge injection signals. Each active pixel iscomposed of various components, including a bump pad, a chargeinjection circuit, a pre-amplifier, a discriminator, adigital-to-analog converter, and a time-to-digital converter. Thesecomponents play essential roles as the front-end link in processingLGAD signals and measuring timing-related information. Theperipheral circuits provide clock signals and readoutfunctionalities. The size of the ETROC1 chip is7 mm× 9 mm. ETROC1 has been fabricated in a 65 nmCMOS process, and extensively tested under stimuli of chargeinjection, infrared laser, and proton beam. The time resolution ofbump-bonded ETROC1 + LGAD chipsets reaches 42–46 ps per hit in thebeam test.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Half-life of 67 Cu

The half-life of 67 Cu was determined through serial gamma-ray spectrometry measurements of the dominant gamma emission (E γ : 184.6 keV; branching ratio: 48.7%) produced following β- decay. Data were collected consecutively for 1000 s per measurement, with a total of 3063 measurements over the duration of 36 days. The incidence rate for the 184.6 keV gamma-ray was determined from the spectral peak area and duration of each measurement. This rate was then corrected to account for detector dead-time, radioactive decay during each acquisition and drift in the computer clock in comparison to NIST nuclear clock. Least-squares regression analysis was performed to determine the half-life of 67 Cu. The result was 61.761 ± 0.004 h, which is the highest precision measurement to date, and marks a 24-fold precision improvement over the current Nuclear Data Sheets value.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A universal and constant rate of gene content change traces pangenome flux to LUCA

Abstract Prokaryotic genomes constantly undergo gene flux via lateral gene transfer, generating a pangenome structure consisting of a conserved core genome surrounded by a more variable accessory genome shell. Over time, flux generates change in genome content. Here, we measure and compare the rate of genome flux for 5655 prokaryotic genomes as a function of amino acid sequence divergence in 36 universally distributed proteins of the informational core (IC). We find a clock of gene content change. The long-term average rate of gene content flux is remarkably constant across all higher prokaryotic taxa sampled, whereby the size of the accessory genome—the proportion of the genome harboring gene content difference for genome pairs—varies across taxa. The proportion of species-level accessory genes per genome, varies from 0% (Chlamydia) to 30%–33% (Alphaproteobacteria, Gammaproteobacteria, and Clostridia). A clock-like rate of gene content change across all prokaryotic taxa sampled suggest that pangenome structure is a general feature of prokaryotic genomes and that it has been in existence since the divergence of bacteria and archaea.

Microbiology↗

Floquet operator dynamics and orthogonal polynomials on the unit circle

Operator spreading under stroboscopic time evolution under a unitary is studied. An operator Krylov space is constructed and mapped to orthogonal polynomials on a unit circle (OPUC), as well as to the Krylov space of the edge operator of the Floquet transverse field Ising model with inhomogeneous couplings (ITFIM). The Verblunsky coefficients in the OPUC representation are related to the Krylov angles parametrizing the ITFIM. The relations between the OPUC and spectral functions are summarized and several applications are presented. These include derivation of analytic expressions for the OPUC under persistent m-periodic dynamics, and the numerical construction of the OPUC for autocorrelations of the homogeneous Floquet-Ising model as well as the Z 3 clock model. The numerically obtained Krylov angles of the Z 3 clock model with long-lived period tripled autocorrelations show a spatial periodicity of six, and this observation is used to develop an analytically solvable model for the ITFIM that mimics this behavior.

Floquet systems↗

YbH + formation in an ytterbium ion trap

The trapped 171 Yb + ion is a promising candidate for portable atomic clock applications. However, with buffer-gas cooled ytterbium ions, the ions can be pumped into a low-lying 2 F 7 / 2 state or form YbH + molecules. These dark states reduce the fluorescence signal from the ions and can degrade the clock stability. In this work, we study the dynamics of the populations of the 2 F 7 / 2 state and YbH + molecules under different operating conditions of our 171 Yb + ion system. Our study indicates that 2 F 7 / 2 -state ions can form YbH + molecules through interactions with hydrogen gas. As observed previously, dissociation of YbH + is observed at wavelengths around 369 nm. We also demonstrate YbH+ dissociation using 405 nm light. Moreover, we show that the population in the dark states can be limited by using a single repump laser at 935 nm. Our study provides insights into the molecular formation in a trapped ion system.

74 ATOMIC AND MOLECULAR PHYSICS↗

Classification of electronic nematicity in three-dimensional crystals and quasicrystals

Electronic nematic order has been reported in a rich landscape of materials, encompassing not only a range of intertwined correlated and topological phenomena but also different underlying lattice symmetries. Motivated by these findings, we investigate the behavior of electronic nematicity as the spherical symmetry of three-dimensional (3D) space is systematically lowered by the lattice environment. Here, we consider all 32 crystallographic point groups as well as four major classes of quasicrystalline point groups, given the recent observations of electronic phases of interest in quasicrystalline materials and artificial twisted quasicrystals. Valuable insights are gained by establishing a mapping between the five-component charge-quadrupolar nematic order parameter of the electronic fluid and the 3D tensorial order parameter of nematic liquid crystals. We find that a uniaxial nematic state is only generically realized in polyhedral point groups (icosahedral and cubic), with the nematic director pointing along different sets of rotational symmetry axes. Interestingly, icosahedral point groups are the only ones in which the five nematic order parameter components transform as the same irreducible representation, making them the closest analog of 3D isotropic nematics. In axial point groups, one of the nematic components is always condensed, whereas the other four components decompose into an in-plane and an out-of-plane nematic doublet, resulting in biaxial nematic ground states. Because these two nematic doublets behave as Z q clock order parameters, this allows us to identify the types of crystals and quasicrystals that can host interesting electronic nematic phenomena enabled by the critical properties of the q ≥ 4 clock model, such as emergent continuous nematic fluctuations in 3D, critical phases with quasi-long-range nematic order in two dimensions (2D), and Ashkin-Teller nematicity in 2D.

3-dimensional systems↗

Dipole-Dipole Frequency Shifts in Multilevel Atoms

Dipole-dipole interactions lead to frequency shifts that are expected to limit the performance of next-generation atomic clocks. In this work, we compute dipolar frequency shifts accounting for the intrinsic atomic multilevel structure in standard Ramsey spectroscopy. When interrogating the transitions featuring the smallest Clebsch-Gordan coefficients, we find that a simplified two-level treatment becomes inappropriate, even in the presence of large Zeeman shifts. Further, for these cases, we show a net suppression of dipolar frequency shifts and the emergence of dominant nonclassical effects for experimentally relevant parameters. Our findings are pertinent to current generations of optical lattice and optical tweezer clocks, opening a way to further increase their current accuracy, and thus their potential to probe fundamental and many-body physics.

74 ATOMIC AND MOLECULAR PHYSICS↗

An Open-Access Repository of Synchrophasor Data Quality Examples: Curation and Example Applications

Synchrophasor measurements are critical in providing wide-area situational awareness to power system operators. However, data artifacts may be introduced due to various issues such as loss of communication, loss of GPS signal, internal clock error, and vendor-specific implementation of phasor estimation algorithms. Tools designed to provide actionable insights from synchrophasor data, hence, must be designed to be robust to these data quality issues. In this work, two years of synchrophasor data sourced from multiple electric utilities in the United States were analyzed to identify examples of data quality problems. These examples were then labeled and published in the Grid Event Signature Library, a publicly available repository of power system measurements hosted by the Oak Ridge National Laboratory. This paper describes the data curation process, and illustrates two application use cases where the dataset can be valuable to the research community. In the first use case, a random forest classifier is trained to distinguish power system disturbance signatures from data anomalies introduced in synchrophasor measurements due to clock errors. The second use case studies the impact of data quality issues on an example synchrophasor application (specifically, event start time determination). The choice of data quality problems investigated is informed by the examples in the repository curated in this work.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Alternative Timing and Synchronization Approach for Situational Awareness and Predictive Analytics

Accurate and synchronized timing information is required by power system operators for controlling the grid infrastructure (relays, Phasor Measurement Units (PMUs), etc.) and determining asset positions. Satellite-based global positioning system (GPS) is the primary source of timing information. However, GPS disruptions today (both intentional and unintentional) can significantly compromise the reliability and security of our electric grids. A robust alternate source for accurate timing is critical to serve both as a deterrent against malicious attacks and as a redundant system in enhancing the resilience against extreme events that could disrupt the GPS network. To achieve this, we rely on the highly accurate, terrestrial atomic clock-based network for alternative timing and synchronization. In this paper, we discuss an experimental setup for an alternative timing approach. The data obtained from this experimental setup is continuously monitored and analyzed using various time deviation metrics. We also use these metrics to compute deviations of our clock with respect to the National Institute of Standards and Technologys (NIST) GPS data. The results obtained from these metric computations are elaborately discussed. Finally, we discuss the integration of the procedures involved, like real-time data ingestion, metric computation, and result visualization, in a novel microservices-based architecture for situational awareness.

Chinthavali, Supriya↗

An 85 nW IoT Node-Controlling SoC for MELs Power-Mode Management and Phantom Energy Reduction

This paper presents an ultra-low power (ULP) node-controlling system-on-chip (SoC) used for power-mode management and phantom energy reduction of miscellaneous electric loads (MELs). The SoC is powered from a single 2.5 V voltage supply enabled by the integrated power management unit (PMU) and can control up to 16 MELs due to the on-chip 16-channel correlator and the 32b RISC-V microprocessor. To further reduce the system power consumption, two clock domains have been adopted for the correlator and the processor separately. Fabricated in 65-nm CMOS, the measured minimum power consumption of the proposed SoC is only 85 nW at 0.45 V voltage supply and 1 kHz clock frequency. The measured maximum operating frequency can go up to 148 kHz with a 0.55 V supply. An application experiment successfully demonstrates that the SoC controls the power modes of MELs from wake-up to cut-off to save the average power and phantom energy.

power-mode management, phantom energy, phantom pow↗

A 194nW Energy-Performance-Aware loT SoC Employing a 5.2nW 92.6% Peak Efficiency Power Management Unit for System Performance Scaling, Fast DVFS and Energy Minimization

A self-powered IoT system-on-chip (SoC) reduces power to sub-μw and employs multiple power-management techniques to trade-off ultra-low power (ULP), higher performance, smaller energy harvester footprint, and longer operating lifetime. Minimum Energy Point Tracking (MEPT) [1]–[4] keeps an SoC operating at the minimum energy point (MEP) to enhance system lifetime. Previous sample-and-hold MEPT schemes need frequent voltage comparisons and a high-frequency clock that increases power [2]. Current-ratio-based MEPT relies on specialized CMOS technology for body-bias tuning [3]. A switched-capacitor-based MEPT can achieve energy minimization at a targeted performance [4], but it uses a 30MHz clock witμW power consumption and low power efficiency. For ULP IoT applications, SoCs need to have ultra-low quiescent power, high efficiency for energy delivery, performance scaling based on available energy, and energy minimization to increase system lifetime. In this work, we propose an ULP IoT SoC with a triple-mode power management unit (PMU) that integrates energy-performance scaling, event-driven fast DVFS, and MEPT features to improve the system energy efficiency, as shown in Fig. 13.8.1. This work achieves a minimum 194nW power consumption for the SoC and 5.2nW quiescent power for the PMU with a 92.6% peak efficiency and >10 4 dynamic range. The timing waveform in Fig. 13.8.1 (bottom), demonstrates the transition of the three modes including energy aware (EA), performance aware (PA), and MEPT based on event priority and input voltage level which reflects the energy availability. As such, the system energy consumption and performance could be well-balanced based on both the input and output conditions.

self-powered IoT system-on-chip (SoC)↗

Photonics Breakthroughs 2024: Narrow-Linewidth Lasers in the Visible and Near-Infrared

Narrow-linewidth lasers enable a variety of high-precision applications, such as sensing, optical clocks, and microwave frequency generation. Advances in photonic integration in the last decade led to the development of ultra-low-noise integrated semiconductor lasers, mostly in the telecom wavelength range. In recent years, the demand for high-performance lasers at shorter wavelengths skyrocketed, driven by applications in sensing and atom trapping. Low-noise lasers are of particular importance in this spectral range, as they are essential for optical clocks. Here, we will review recent progress in narrow-linewidth lasers at shorter wavelengths, present results on a hybrid-integrated low-noise laser at 780 nm and discuss the perspectives and challenges of high-performance semiconductor lasers in the visible and near-infrared.

Prokoshin, Artem [King Abdullah University of Scie↗

Superconducting Shuttle-Flux Shift Register for Race Logic and Its Applications

Here this paper presents a superconducting, magnetically-coupled, shuttle-flux shift register (SF-SR) that stores single flux quantum (SFQ) pulses. This shift register has a DC bias operating margin of ±34% at 10 GHz, with a power dissipation of 3.6 μW and 38% fewer Josephson junctions (JJs) when scaled up to multiple stages compared to a data flip-flop (DFF) based shift register. The clock input is inductively coupled and is independent from the data input. We then present three applications for our SF-SR. In the first application, we add two non-destructive readout (NDRO) cells to construct a buffer that temporarily stores the temporal information of a series of race logic (RL) pulses. The second application is a pseudo-random number generator based on a linear function shift register (LFSR). The third application is N parallel SF-SRs that can act similar to a deserializer or instead can emulate a single SF-SR of N times higher clock frequency. These three applications motivate deep shift registers with many shifting intervals, which our SF-SR can implement with fewer JJs and lower power consumption compared to DFF-based shift registers.

42 ENGINEERING↗

White Rabbit Time Synchronization for Radiation Detector Readout Electronics

As radiation detector arrays in nuclear physics applications become larger and physically more separated, the time synchronization and trigger distribution between many channels of detector readout electronics become more challenging. Clocks and triggers are traditionally distributed through dedicated cabling, but newer methods such as the IEEE 1588 Precision Time Protocol and White Rabbit allow clock synchronization through the exchange of timing messages over Ethernet. Consequently, we report here the use of White Rabbit in a new detector readout module, the Pixie-Net XL. Herein, the White Rabbit core, data capture from multiple digitizing channels, and subsequent pulse processing for pulse height and constant fraction timing are implemented in a Kintex 7 FPGA. The detector data records include White Rabbit time stamps and are transmitted to storage through the White Rabbit core's gigabit Ethernet data path or a slower diagnostic/control link using an embedded Zynq processor. The performance is characterized by time-of-flight style measurements and by time correlation of high energy background events from cosmic showers in detectors separated by longer distances. Software for the Zynq processor can implement "software triggering", for example to limit recording of data to events where a minimum number of channels from multiple modules detect radiation at the same time.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Tonoplast Sucrose Transporter SUT4-Dependent Sugar Partitioning Modulates Phenological Transitions and Reproductive Success in Poplar

Climate uncertainty is intensifying the need for greater plasticity in carbohydrate reserve utilization to support winter survival and spring growth in woody perennials. In poplar, the single-copy SUT4, which encodes a tonoplast-localized sucrose transporter, and the SUT5/SUT6 genome duplicates, which encode plasma membrane-localized transporters, are expressed year-round, with SUT4 showing the highest expression during cool seasons. Given its role in vacuolar sucrose efflux and winter-predominant expression, SUT4 may play a key role in modulating seasonal carbohydrate dynamics. While SUT4-knockdown and knockout effects have been studied under greenhouse conditions, their impact under field conditions remains unexplored. Here, we report a field-based study comparing CRISPR knockout mutants of winter-expressed SUT4 and SUT5/SUT6 in Populus tremula x alba. We show that sut4, but not sut5/6, mutants exhibited earlier autumn leaf senescence, delayed spring bud flush, reduced stem growth, and altered sugar partitioning in winter xylem and bark relative to controls. After 2 years in the field, all genotypes flowered before leaf flush in early spring; however, sut4 mutants produced sterile ovules despite developing normal-looking catkins. Metabolic profiling revealed disrupted sucrose and raffinose dynamics in elongating sut4 catkins. This was accompanied by transcriptomic signatures of elevated stress and downregulation of proanthocyanidin biosynthesis and circadian clock genes. These findings highlight the critical role of SUT4 in coordinating sugar allocation, stress responses, and seasonal development in poplar.

09 BIOMASS FUELS↗