SEARCH · Engineering Papers
Results for “capacitance”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Test particle simulation of the role of ballistic electrons in hybrid dc/rf capacitively coupled plasmas in argon
Hybrid dc/rf plasma sources are an emerging equipment technology in plasma etching for semiconductor manufacturing. In this work, test particle simulations are used to describe the nature and role of the ballistic electrons, which originate as secondary electrons on a dc/rf (i.e., VHF, 60 MHz) biased upper electrode and are then accelerated in the sheath toward the opposite non-dc biased lower electrode. This opposite electrode, on which a wafer is placed, may have rf bias power applied to it at low frequencies. 2 MHz is typical. While a hybrid dc/rf plasma source is sustained by the VHF power source, simulations reveal ballistic electrons assist in the production of a plasma characterized by a relatively high ionization rate constant, especially in the dc sheath. The dc source helps to provide a source of high energy electrons that may reach the wafer. However, when the rf bias is applied on the lower electrode, ballistic electrons are confined in the potential well formed between electrodes and easily thermalized in the bulk. The simulated electron density dependencies on the dc bias and lower electrode rf power describe a dual mode source and are consistent with measured data. When no rf power is applied on the electrode opposite to the dc power source, the bulk electron density drops with increasing dc power at constant VHF power; when rf power is applied to the electrode opposite to the dc power source, the bulk electron density increases with dc power at constant VHF power. The fraction of electrons significantly above thermal reaching the wafer is much higher when no rf power is applied at the lower electrode but the total flux lower. Depending on its level, rf power applied to the wafer may effectively suppress the number of ballistic electrons that reach the wafer. Finally, the ionization rate constant due to ballistic electrons can be fitted as a simple function of the electric field in the dc sheath.
Test particle simulation of the role of ballistic electrons in hybrid dc/rf capacitively coupled CF{sub 4} plasmas
Hybrid dc/rf plasma sources are an emerging equipment technology in plasma etching for semiconductor manufacturing. In this type of plasma source, ballistic electrons originate as secondary electrons on a dc/rf (i.e., VHF, 60 MHz) biased electrode and are then accelerated in the sheath toward an opposite non-dc biased lower electrode. For electropositive (argon) plasmas it has been shown that the primary contribution of ballistic electrons is ionization in the dc sheath and modulation of the discharge properties. Whether applied dc power net increases or decreases the plasma electron density depends on the rf power environment of the opposing substrate electrode. When rf power is applied to a substrate electrode, the rf self-bias creates a potential well that traps the ballistic electrons, the result being that the electron density increases with dc power. In most cases the fraction of high energy electrons that reach the electrode is small. In this article, the authors describe the use of test particle Monte Carlo simulations to describe the behavior of hybrid dc/rf electronegative (CF{sub 4}) plasmas. In contrast to the behavior in argon, process experiments with electronegative gases such as CF{sub 4} indicate that the electron density is independent of dc bias power when no rf power is applied to the wafer. Test particle simulations show that CF{sub 4} provides for a 'self-confinement' effect caused by large cross sections for vibrational excitation at intermediate to low electron energies, which results in weak dependence of electron density on dc bias voltage when low frequency bias is not applied to the wafer. This emphasizes the important role of gas composition and cross-section structure in the control of dc/rf plasmas. Consistent with experiment, test particle Monte Carlo simulations also show that when rf is applied to the substrate, overall the CF{sub 4} plasma's macroscopic properties are similar manner to argon plasmas. Even so, differences between the argon and CF{sub 4} plasmas occur related to the scaling of the fraction of ballistic electrons that reach the wafer as a function of dc and rf power. A regime is identified in which CF{sub 4} and argon plasmas have the equivalent ratio of ballistic to thermal electron density adjacent to the surface. The authors explain that the differences are related to different thermalization and ionization mechanisms in these plasmas. In addition, they find the electron attachment constant is zero in the dc sheath and nearly constant value in the bulk as the transit time in the sheath is far less than the mean attachment time. The same simple function to express ionization rate constant as a function of electric field in the dc sheath, developed for argon, can be also applied to CF{sub 4}.
Missile Captive Carry Monitoring using a Capacitive MEMS Accelerometer
Military missiles are exposed to many sources of mechanical vibration that can affect system reliability, safety, and mission effectiveness. One of the most significant exposures to vibration occurs when the missile is being carried by an aviation platform, which is a condition known as captive carry. If the duration of captive carry exposure could be recorded during the missile’s service life, several advantages could be realized. Missiles that have been exposed to durations outside the design envelop could be flagged or screened for maintenance or inspection; lightly exposed missiles could be selected for critical mission applications; and missile allocation to missions could be based on prior use to avoid overuse. The U. S. Army Aviation and Missile Research Development and Engineering Center (AMRDEC) has been developing health monitoring systems to assess and improve reliability of missiles during storage and field exposures. Under the direction of AMRDEC staff, engineers at the Pacific Northwest National Laboratory have developed a Captive Carry Health Monitor (CCHM) for the HELLFIRE II missile. The CCHM is an embedded usage monitoring device installed on the outer skin of the HELLFIRE II missile to record the cumulative hours the host missile has been in captive carry mode and thereby assess the overall health of the missile. This paper provides an overview of the CCHM electrical and package design, describes field testing and data analysis techniques used to identify captive carry, and discusses the potential application of missile health and usage data for real-time reliability analysis and fleet management.
Nitrogen-doped mesoporous carbon of extraordinary capacitance for electrochemical energy storage
Store more energy with a touch of nitrogen In contrast to batteries, capacitors typically can store less power, but they can capture and release that power much more quickly. Lin et al. fabricated a porous carbon material that was then doped with nitrogen. This raised the energy density of the carbon more than threefold—an increase that was retained in full capacitors, without losing their ability to deliver power quickly. Science , this issue p. 1508
Ultrahigh capacitive energy density in ion-bombarded relaxor ferroelectric films
Dielectric capacitors can store and release electric energy at ultrafast rates and are extensively studied for applications in electronics and electric power systems. Among various candidates, thin films based on relaxor ferroelectrics, a special kind of ferroelectric with nanometer-sized domains, have attracted special attention because of their high energy densities and efficiencies. We show that high-energy ion bombardment improves the energy storage performance of relaxor ferroelectric thin films. Intrinsic point defects created by ion bombardment reduce leakage, delay low-field polarization saturation, enhance high-field polarizability, and improve breakdown strength. We demonstrate energy storage densities as high as ~133 joules per cubic centimeter with efficiencies exceeding 75%. Deterministic control of defects by means of postsynthesis processing methods such as ion bombardment can be used to overcome the trade-off between high polarizability and breakdown strength.
Simulating Electric Double Layer Capacitance of Mesoporous Electrodes with Cylindrical Pores
Explore the source record for details and available documents.
A Combined Modeling and Experimental Study Assessing the Impact of Fluid Pulsation on Charge and Energy Efficiency in Capacitive Deionization
Explore the source record for details and available documents.
Influence of Analysis Method on the Experimentally Observed Capacitance at the Gold-Ionic Liquid Interface.
Abstract not provided.
Hierarchical Porosity in Electrospun Capacitive Deionization Electrodes
Explore the source record for details and available documents.
Missile Captive Carry Monitoring and Helicopter Identification Using a Capacitive Microelectromechanical Systems Accelerometer
Military missiles are exposed to many sources of mechanical vibration that can affect system reliability, safety, and mission effectiveness. The U. S. Army Aviation and Missile Research Development and Engineering Center (AMRDEC) has been developing missile health monitoring systems to assess and improve reliability, reduce life cycle costs, and increase system readiness. One of the most significant exposures to vibration occurs when the missile is being carried by a helicopter or other aviation platform, which is a condition known as captive carry. Recording the duration of captive carry exposure during the missile’s service life can enable the implementation of predictive maintenance and resource management programs. Since the vibration imparted by each class of helicopter varies in frequency and amplitude, tracking the vibration exposure from each helicopter separately can help quantify the severity and harmonic content of the exposure. Under the direction of AMRDEC staff, engineers at the Pacific Northwest National Laboratory have developed a Captive Carry Health Monitor (CCHM) for the Hellfire II missile. The CCHM is an embedded usage monitoring device installed on the outer skin of the Hellfire II missile to record the cumulative hours the host missile has been in captive carry mode. To classify the vibration by class of helicopter, the CCHM analyzes the amplitude and frequency content of the vibration with the Goertzel algorithm to detect the presence of distinctive rotor harmonics. Cumulative usage data are accessible in theater from an external display; monthly usage histograms are accessible through an internal download connector. This paper provides an overview of the CCHM electrical and package design, describes field testing and data analysis techniques used to monitor captive carry identify and the class of helicopter, and discusses the potential application of missile health and usage data for real-time reliability analysis and fleet management.
Evolutionary Capacitance and Control of Protein Stability in Protein-Protein Interaction Networks
N/A
Capacitive fundamental power coupler and pickup for the 56 MHz SRF cavity
The beam excited 56 MHz SRF cavity will have a power coupler for a fast frequency tuner. The calculation shows the coupling of the power coupler, β opt , is around 50. Size and location of the power coupler are determined by measurements. Measurements are in good agreement with the simulation results. The axial location of the power coupler for the Nb cavity is limited by corrugations made on the cavity outer conductor for purpose of removing any multipacting. The preferred axial location is 14.5 cm away from the cavity gap start where a slow tuner plate will be. MWS simulations are done to determine the length of the power coupler inner conductor and pickup probe for the Nb cavity at the fixed axial location. Size and location of both the fundamental power coupler and the pickup probe can be decided from the simulation results.
A Multi-Contact, Low Capacitance HPGe Detector for High Rate Gamma Spectroscopy
The detection, identification and non-destructive assay of special nuclear materials and nuclear fission by-products are critically important activities in support of nuclear non-proliferation programs. Both national and international nuclear safeguard agencies recognize that current accounting methods for spent nuclear fuel are inadequate from a safeguards perspective. Radiation detection and analysis by gamma-ray spectroscopy is a key tool in this field, but no instrument exists that can deliver the required performance (energy resolution and detection sensitivity) in the presence of very high background count rates encountered in the nuclear safeguards arena. The work of this project addresses this critical need by developing a unique gamma-ray detector based on high purity germanium that has the previously unachievable property of operating in the 1 million counts-per-second range while achieving state-of-the-art energy resolution necessary to identify and analyze the isotopes of interest. The technical approach was to design and fabricate a germanium detector with multiple segmented electrodes coupled to multi-channel high rate spectroscopy electronics. Dividing the germanium detector’s signal electrode into smaller sections offers two advantages; firstly, the energy resolution of the detector is potentially improved, and secondly, the detector is able to operate at higher count rates. The design challenges included the following; determining the optimum electrode configuration to meet the stringent energy resolution and count rate requirements; determining the electronic noise (and therefore energy resolution) of the completed system after multiple signals are recombined; designing the germanium crystal housing and vacuum cryostat; and customizing electronics to perform the signal recombination function in real time. In this phase I work, commercial off-the-shelf electrostatic modeling software was used to develop the segmented germanium crystal geometry, which underwent several iterations before an optimal electrode configuration was found. The model was tested and validated against real-world measurements with existing germanium detectors. Extensive modeling of electronic noise was conducted using established formulae, and real-world measurements were performed on candidate front-end electronic components. This initial work proved the feasibility of the design with respect to expected high count rate and energy resolution performance. Phase I also delivered the mechanical design of the detector housing and vacuum cryostat to be built in Phase II. Finally, a Monte Carlo simulation was created to show the response of the complete design to a Cs-137 source. This development presents a significant advance for nuclear safeguards instrumentation with increased speed and accuracy of detection and identification of special nuclear materials. Other significant applications are foreseen for a gamma-ray detector that delivers high energy resolution (1keV FWHM noise) at high count rate (1 Mcps), especially in the areas of physics research and materials analysis.
Treatment of Produced Water From Coal-Bed Methane Production Using Capacitive Deionization Final Report CRADA No. TSV-1380-97
The production af Coal-Bed Methane (CBM) is always accompanied by the production of large amounts of water. The produced water is typically too high in dissolved solids and salinity to be suitable for surface disposal.
Capacitance of a Ge/SiGe heterostructure field-effect transistor
In this project we studied undoped Ge/SiGe heterostructure field-effect transistors, which had a very wide hole density range from 1x10 10 cm -2 to 3.5x10 11 cm -2 tunable by (negative) gate voltage. At low temperatures reasonably high carriers mobility of about 3.4x10 5 cm 2 /Vs was achieved.
K-Modules: Capacitive Energy Modules for Pulsed Power Applications [Slides]
K-Modules are modules containing an assembly of capacitors. The modules are meant to be daisy-chained to form a Marx bank (bank of capacitors). Discharging the bank produces a high voltage, high current pulse, that when coupled to an X-ray or electron beam tube, generates X-rays or an intense electron beam. Number of modules in the stack can be varied to meet different pulsed power applications. The technology addresses the need for an alternate provider with a new, robust design. The technology has the potential to extend the life of the X-ray radiography program in the country.