Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “building case study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Effective Stakeholder Communications in a Changing Budgetary Environment - 15541

Effective communications allow stakeholders to maintain trust and avoid misunderstandings by building relationships that foster better teamwork, more informed decision making, and faster problem-solving. This presentation and accompanying paper will feature a case study on the Liquid Waste program of Savannah River Remediation LLC (SRR) at the Savannah River Site (SRS) in South Carolina exemplifying its effective communication strategies with stakeholders and its partnership approaches to deliver consistent, constructive, and concise communications with stakeholders. Furthermore, this presentation proposes for consideration new models for communication with stakeholders regarding funding across DOE waste cleanup sites. This presentation also proposes a model for consideration instituting a competitive set-aside incentive program for DOE contractors to foster further efficiency, innovation, and measurable progress. The set-aside pool of funding would reward DOE site's on tangible measurable benefits such as progress in meeting milestones, furthering specific environmental risk reducing life-cycle costs. Reduced budgetary funding can lead to much consternation for stakeholders, potentially causing a breakdown of years of hard-earned trust and jeopardizing future cleanup efforts. Therefore, organizations should pro-actively work together to develop a strategy to communicate effectively with stakeholders in order to assuage stakeholder concerns, mitigate risks, and continue to carry out its mission. In the face of funding reductions, effective communication can help promote better understanding by providing more information to help stakeholders understand DOE's funding allocation for each site. Furthermore, providing a set-aside competitive program could further incentivize innovation and reward progress. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An Online Tool for Preliminary Design and Techno-Economic Analysis of District Geothermal Heating and Cooling Systems

District geothermal heating and cooling systems (DGHCS) have significant benefits for reducing energy consumption as well as building- and grid-level peak electric demand. Currently, no publicly available tools are available to effectively design and conduct techno-economic analysis of DGHCS. GeoWISE was originally developed for preliminary design and techno-economic analysis of geothermal heating and cooling systems in an individual commercial or residential building. This paper introduces recent upgrades of GeoWISE that allow users to design and conduct techno-economic analysis of DGHCS. Several new features are implemented in GeoWISE to allow selection and specification of multiple new or existing buildings. A database of information for over 125 million existing U.S. buildings was used in GeoWISE that allows users easily locate existing buildings of interest based on street addresses, and optionally edit information of the buildings (e.g., footprint, vintage, principal functions, number of floors, window-to-wall ratio). Unique energy simulation models of the selected buildings are then automatically created using the Automatic Building Energy Modeling (AutoBEM) and EnergyPlus simulations are performed to predict thermal loads of the buildings. A simplified DGHCS is then designed and simulated to predict its energy use. A central borehole heat exchanger (BHE) of the DGHCS is sized using the RowWise algorithm of GHEDesigner to meet the thermal loads within user-specified land areas for installing BHE. The upgraded GeoWISE reports the needed capacity of heating and cooling equipment in each building, design of the central BHE, energy consumption reduction, and energy cost saving resulting from using DGHCS compared with conventional HVAC systems. A case study is showcased using the upgraded GeoWISE to design and conduct techno-economic analysis of a simplified DGHCS.

Prem Anand Jayaprabha, Jyothis Anand [ORNL] (ORCID↗

Dynamic Emulation of NASA Missions for IVandV: A Case Study of JWST and SLS

Software-Only-Simulations are an emerging but quickly developing field of study throughout NASA. The NASA Independent Verification Validation (IVV) Independent Test Capability (ITC) team has been rapidly building a collection of simulators for a wide range of NASA missions. ITC specializes in full end-to-end simulations that enable developers, VV personnel, and operators to test-as-you-fly. In four years, the team has delivered a wide variety of spacecraft simulations ranging from low complexity science missions such as the Global Precipitation Management (GPM) satellite and the Deep Space Climate Observatory (DSCOVR), to the extremely complex missions such as the James Webb Space Telescope (JWST) and Space Launch System (SLS).

Emulation↗

Latent heat thermal energy storage performance maps enabling fast & accurate building energy simulations

Thermal energy storage (TES) using phase change materials (PCMs) has gained attention as an effective approach to manage energy demand fluctuations and shift peak building loads. PCM embedded heat exchangers (PCM-HXs) offer high energy storage density and low temperature variation during phase change, being suitable for load-shifting applications. However, this component is typically evaluated using computationally expensive methods, which present significant challenges when the ultimate goal is to assess the performance of PCM-HX integrated thermal energy storage systems in the full building context. In this paper, we present a methodology to generate highly accurate and computationally efficient PCM-HX performance maps which can be easily integrated into building energy simulation tools to analyze the feasibility of space conditioning systems with latent heat PCM-based TES. The performance maps are generated using a computationally efficient PCM-HX simulation tool based on a Generalized Resistance-Capacitance Model (GRCM) which can simulate arbitrary PCM-HXs with high accuracy and significantly less computational effort compared to full CFD simulations. The methodology was verified for a case study considering a 5-ton (~17.5 kW) air-to-water heat pump-thermal energy storage system (HP-TES), which was co-simulated in Modelica for a DOE prototype small-office building in Vienna, Austria, using Spawn of EnergyPlus™. The TES performance maps provided accurate predictions of PCM-HX behavior when used as Modelica component, with deviations within 2-4% while also achieving at least 103 computational time reduction. Leveraging this faster prediction capability, four PCMs with different melting temperatures for cooling (12°C, 16°C) and heating (31°C, 36°C) were assessed to investigate their impact on system performance. This work highlights the importance of robust PCM-HX models for efficient and high-fidelity building-level simulations, presenting new opportunities for advanced control strategy development and parametric analysis of TES configurations in a computationally efficient manner

Modelica Building Simulations↗

Solar Photovoltaic (PV) Manufacturing Expansions in the United States, 2017-2019: Motives, Challenges, Opportunities, and Policy Context

This report analyzes U.S. PV manufacturing announcements from 2017 through July-2019 and explores the potential impact of tariffs on the competitiveness of U.S. PV module manufacturing. First, the fraction of announcements that resulted in established facilities in the time frame specified is analyzed, as well as firm nationality and the existence of any other U.S. facilities for the firm. The prevalence of different PV product types among the announcements was also analyzed, as well as the type of facilities selected for development (greenfield, existing PV factories, or repurposed buildings). The cost to build these facilities was also analyzed in the context of their capacity, the value of incentives received by state and local governments, and the number of jobs created. Case studies of Auxin Solar, First Solar, Hanwha Q Cells, JinkoSolar, LG, Silfab, Solaria, and SunPower were conducted and highlight five factors influencing firms’ decisions to expand their U.S. PV production capacity. These included: 1) proximity to demand, including supply contracts and demand for domestic content 2) tariffs and other incentives. The Section 201 tariffs on PV module imports were often described helpful but tariffs on cell imports (Section 201) or materials (Section 301, Section 232) were often described as counterproductive since U.S. supply chains do not exist for many necessary goods. The corporate tax decrease and local incentives were often mentioned as helpful. 3) the ability to move quickly in order to maximize the benefit of the Section 201 tariffs. This affected decisions to select localities with faster permitting or moving into existing buildings. 4) competition with scale, where competing with Asian PV imports or avoiding imports of material from China was challenging due to the larger scale of Asian manufacturers. Additionally, smaller firms expressed concerns that larger firms may not need their U.S. facilities to profitable. 5) access to capital, which was a particular challenge for smaller firms. Several U.S. tariffs affect the economics of PV cells, modules, and balance-of-module (BOM) materials, some of which are applicable to a long list of countries and others applicable only to China or Taiwan. We analyze how the tariffs interact to affect the prices of c-Si modules sourced under various assumptions about domestic and imported components and assembly. We estimate module prices under a range of baseline scenarios featuring U.S.-assembled modules with Southeast Asian cells (not from China or Taiwan). When all BOM components are sourced from the United States, baseline module prices are $0.37/W (below the 2.5-GW Section 201 cell cap) to $0.42/W (above the 2.5-GW cell cap). If all BOM components are sourced from China, the module price in this baseline U.S.-assembly scenario can reach up to $0.60/W. Imported module prices are lower than or within the range of the U.S.-assembled baseline prices under some conditions. Importing bifacial modules from Southeast Asia is the lowest-priced alternative, at $0.35/W, because bifacial modules are excluded from the Section 201 tariffs. Importing Southeast Asia modules that contain U.S. cells results in a price of $0.38/W, also owing to a Section 201 exclusion. Importing Southeast Asian modules that have Southeast Asian cells yields a price of $0.44/W, and importing Chinese modules that have U.S. cells yields a price of $0.58/W. These results suggest that U.S. tariff policy in 2019 may encourage U.S. assembly of mono-facial c-Si modules if the 2.5-GW cell import cap is not reached and Chinese BOM imports are negligible. However, some imported module options may offer the lowest prices if the 2.5-GW cell import cap is reached and/or U.S. module manufacturers must rely on significant Chinese BOM content. The analysis shows the 2.5-GW cell cap may be exceeded in 2019 and following years. It is also likely that U.S. module manufacturers will need to use at least some Chinese BOM content, since U.S. module manufacturers have stated that U.S. supply chains do not exist (or do not exist at a sufficient scale) for most BOM components, which makes them at least partially reliant on Chinese BOM and thus subject to Section 301 tariffs.

14 SOLAR ENERGY↗

Case Study - Intentional Inclusion: How embedding inclusion into the fabric of Idaho National Laboratory positioned the organization for a sustainable future

Idaho National Laboratory, a Department of Energy national laboratory headquartered in Idaho Falls, Idaho, set out to embed inclusion into every aspect of its organization. The goal was to ensure the laboratory is a place where everyone feels they are valued, belong and can bring their best selves to work each day. The laboratory viewed inclusion as a journey in which a consistent, collective commitment to intentional decision-making and incremental progress ultimately achieves amazing results. INL’s intentional inclusion strategy has allowed the organization to: • Retain and build a next-generation workforce to transform the world’s energy future and secure the nation’s most critical infrastructure. • Lead inclusively through individual, team-based, and labwide actions that elevate organizational effectiveness. • Grow laboratory cultural acumen by establishing a clear connection between inclusion and mission success. This case study shares how INL brought employees along on the inclusion journey and inspired everyone to keep moving forward together.

99 GENERAL AND MISCELLANEOUS↗

Development of Building Design Optimization Methodology: Residential Building Applications

Building design optimization is a highly complex problem, requiring long computational running processes because of the many options that exist when a building is being designed. This paper introduces an integrated approach through which to perform this optimization within an acceptable time frame. The approach includes the methods of variable selection, model simplification, and a sequential optimization process. Using singular value decomposition, a large number of design variables is reduced to a smaller subset that can be solved more quickly through the optimization algorithm. To expedite the variable selection process, a modeling approach that quickly simulates annual energy consumption was developed to replace full annual energy simulations. The developed methodology was applied to two residential buildings in the US, and the results are discussed herein. To assess the accuracy of the integrated optimization methodology, the optimized life cycle costs are compaa variables demonstrating the strongest contributions in the optimization study were identified. The proposed methodology significantly shortened the time requirements for the optimization processes of the two case studies by 74% and 84%; the optimized life cycle costs were within 0.05% and 0.06%, respectively, of the optimum point.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Geostatistical mapping of Cs-137 contamination depth in building structures by integrating ISOCS measurements of different spatial supports

Reliable methods to determine the contamination depth in nuclear building structures are very much needed for minimizing the radioactive waste volume and the decontamination workload. This paper investigates the geostatistical integration of in situ gamma-ray spectroscopy measurements of different spatial supports. A case study is presented from the BR3 decommissioning project, yielding an estimated reduction of waste volume of ∼35%, and recommendations are made for future application of the proposed methodology. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Quantum mechanics capacitance molecular mechanics modeling of core-electron binding energies of methanol and methyl nitrite on Ag(111) surface

We study a newly devised quantum mechanics capacitance molecular mechanics (QMCMM) method for the calculation of core-electron binding energies in the case of molecules adsorbed on metal surfaces. This yet untested methodology is applied to systems with monolayer of methanol/methyl nitrite on an Ag(111) surface at 100 K temperature. It was found out that the studied C, N, and O 1s core-hole energies converge very slowly as a function of the radius of the metallic cluster, which was ascribed to build up of positive charge on the edge of the Ag slab. Further analysis revealed that an extrapolation process can be used to obtain binding energies that deviated less than 0.5 eV against experiments, except in the case of methanol O 1s where the difference was as large as 1.8 eV. Additional QM-cluster calculations suggest that the latter error can be connected to the lack of charge transfer over the QM–CMM boundary. Thus, the results indicate that the QMCMM and QM-cluster methods can complement each other in a holistic picture of molecule-adsorbate core-ionization studies, where all types of intermolecular interactions are considered.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A novel stochastic modeling method to simulate cooling loads in residential districts

District cooling systems are widely used in urban residential communities in China. Most of such systems are oversized, which leads to wasted investment, low operational efficiency and, thus, waste of energy. The accurate prediction of district cooling loads that can support the rightsizing of cooling plant equipment remains a challenge. This study develops a novel stochastic modeling method that consists of (1) six prototype house models representing most apartments in a district, (2) occupant behavior models of residential buildings reflecting their spatial and temporal diversity as well as their complexity based on a large-scale residential survey in China, and (3) a stochastic sampling process to represent all apartments and occupants in the district. The stochastic method was applied to a case study using the Designer's Simulation Toolkit (DeST) to simulate the cooling loads of a residential district in Wuhan, China. The simulation results agreed well with the measured data based on five performance metrics representing the aggregated cooling consumption, the peak cooling loads, the spatial load distribution, the temporal load distribution and the load profiles. Two prevalent simulation methods were also employed to simulate the district cooling loads. Here, the results showed that oversimplified assumptions about occupant behavior could lead to significant overestimation of the peak cooling load and the total cooling loads in the district. Future work will aim to simplify the workflow and data requirements of the stochastic method for its application, and to explore its use in predicting district heating loads and in commercial or mixed-use districts.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Feasibility Studies as Catalysts for Capacity Building: The DEVELOP Experience from Local to National Scale

The NASA DEVELOP National Program occupies a unique niche in the capacity development ecosystem. It is not a traditional training or educational program primarily focused on individual capacity, nor is it a full-scale co-development program focused on institutional capacity. NASA DEVELOP conducts 10-week feasibility studies that bring together teams of participants and decision making partners. The participants are competitively selected students and emerging or transitioning professionals, who build their STEM and professional skillsets. The partners are groups that have decision making requirements that may benefit from insights that Earth observations can provide. The interaction of the participants and partners over the intense 10-week time period is especially well adapted to building capacity at smaller scales. DEVELOP projects have shown good results when working at municipal and smaller administrative levels like U.S. counties. Even when working with higher administrative levels like provinces, U.S states, or even national or federal levels, DEVELOP has shown most success when working with more localized institutions like state forests or national parks. This presentation will recount case studies of how DEVELOP projects worked with more local or “localized” partners and compare with outcomes with partners at other scales: state/provincial and federal/national levels.

Capacity Building↗

Dynamic metrics of natural ventilation cooling effectiveness for interactive modeling

The evaluation of natural ventilation potential for cooling indoor spaces during the early design phases is of great interest to researchers and practitioners. Among various definitions and usages for natural ventilation potential (NVP) in early design evaluation, this paper reviews and identifies the key performance indicators, and proposes two new dynamic metrics—natural ventilation cooling effectiveness (NVCE) and climate potential utilization ratio (CPUR). The metrics are dynamically responsive to various design options, in both steady and transient states, allowing consideration of thermal mass. Assisting in design development processes, the metrics quantify how well indoor spaces make use of natural ventilation’s cooling capacity. Case studies are presented to demonstrate how NVCE and CPUR enable designers to evaluate the predicted performance and how to apply the information to improve building design. Finally, the results of the design iterations showed that the relationship among various design parameters should be dynamically understood in order to evaluate the performance of natural ventilation, confirming that “the more the airflow, the greater the potential,” and “the heavier the thermal mass, the greater the energy saving” were not always true.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Elucidating the impact of fiber source on polypropylene/hemp composite performance for the automotive industry

Given their high strength-to-weight ratio, there is an ever-increasing volume of plastics being used in the automotive industry as plastics aid in the charge to lightweight vehicles for improved fuel efficiency. However, these plastics are often landfilled at their end-of-life, which has given rise to the demand for sustainable materials and waste management alternatives compared to purely synthetic systems. Natural fiber composites have been explored as a viable material option to reduce the environmental impact of plastic use in automobiles while simultaneously ensuring the part performance is not sacrificed. Herein, we explored the use of hemp/polypropylene (PP) composites in which US-sourced hemp is compared to internationally sourced and industrially available hemp. There appears to be a minimal impact on the composite properties regardless of fiber sourcing, and the addition of a natural filler to the PP matrix results in up to a 367% increase in Young's modulus, 126% increase in heat deflection temperature, and comparable water uptake performance. It should be noted that the natural filler addition does increase density by up to 13% due to the higher density of natural fibers compared to the low-density PP matrix. A modified rule of mixtures calculation revealed that the composite materials produced in this study demonstrated good agreement with analytical modeling. Finally, a screening analysis was performed exploring the transportation of hemp fibers, and the results build a strong case for regionalized manufacturing of automotive parts.

Hubbard, Amber M. [Oak Ridge National Laboratory (↗

Structuring Formal Control Systems Specifications for Reuse: Surviving Hardware Changes

Formal capture and analysis of the required behavior of control systems have many advantages. For instance, it encourages rigorous requirements analysis, the required behavior is unambiguously defined, and we can assure that various safety properties are satisfied. Formal modeling is, however, a costly and time consuming process and if one could reuse the formal models over a family of products, significant cost savings would be realized. In an ongoing project we are investigating how to structure state-based models to achieve a high level of reusability within product families. In this paper we discuss a high-level structure of requirements models that achieves reusability of the desired control behavior across varying hardware platforms in a product family. The structuring approach is demonstrated through a case study in the mobile robotics domain where the desired robot behavior is reused on two diverse platforms-one commercial mobile platform and one build in-house. We use our language RSML (-e) to capture the control behavior for reuse and our tool NIMBUS to demonstrate how the formal specification can be validated and used as a prototype on the two platforms.

Thompson, Jeffrey M.↗

Air Quality Forecasting at Sub-City Scale by Combining Models, Satellites, and Surface Measures

While there are a variety of sources for air quality information, no one source simultaneously allows for high accuracy, low bias, fine spatial resolution, wide spatial coverage, high temporal frequency, and the capability for near-term forecasting of air quality. Global models, like the NASA’s Goddard Earth Observing System -Composition Forecasting (GEOS-CF) model, provide global coverage and forecasting capabilities, but operate at relatively coarse spatial resolution and require ground-truthing with in-situ data. Polar-orbiting satellite data products, like those of the ESA TROPOspheric Monitoring Instrument (TROPOMI), provide higher-spatial-resolution remote sensing of atmospheric composition, but are limited by cloud cover and overpass times and report column-integrated quantities. Surface measurements, both from regulatory-grade monitors and low-cost networks, measure “nose-level” air quality, but may not represent concentration variability across large spatial domains, and (in the case of low-cost sensors) are subject to interference and biases. There exists a great potential to combine these diverse data sources together, using the strengths of some to offset the weaknesses of others to build a more comprehensive picture of air quality. This presentation will summarize results from ongoing efforts to produce such a combined forecast, with application case studies for surface-level Nitrogen Dioxide forecasting in several major US cities. Furthermore, we will examine the relative impacts and benefits of different data sources on the forecasting accuracy at different spatial and temporal scales. Finally, we will examine the potential for integrating low-cost sensors into such a system, both in terms of using these integrated air quality estimates as a baseline from which to calibrate networks of low-cost sensors in the field, and in terms of using dense networks of low-cost sensors to refine the spatial resolution of integrated air quality forecasts.

Air Quality↗

Technology Solutions Case Study: Durable Interior Foundation Insulation Retrofits for Cold Climates, Cloquet, Minnesota

Thermal and moisture problems in existing basements create a unique challenge as the exterior face of the wall is not easily or inexpensively accessible. This approach by the NorthernSTAR Building America Partnership team addresses thermal and moisture management from the interior face of the wall without disturbing the exterior soil and landscaping. It is effective at reducing energy loss through the wall principally during the heating season. The team conducted experiments at the Cloquet Residential Research Facility to test the heat and moisture performance of four hollow masonry block wall systems and two rim-joist systems. These systems were retrofitted with interior insulation in compliance with the 2012 IECC. The research showed for the first time that, for masonry block walls in a cold climate, a solid bond beam or equivalent provides adequate resistance to moisture transport from a hollow core to the rim-joist cavity. Thus, a solid top course is a minimum requirement for an interior retrofit insulation system.

BASEMENT↗